• Title/Summary/Keyword: rate of temperature rise

Search Result 359, Processing Time 0.024 seconds

A Study on Geotop Classification and Geodiversity in Mt. Jeombong Experimental Forest (점봉산 시험림 지역의 지오톱 분류와 지형다양성 연구)

  • Kim, Nam-Shin;Han, DongUk;Cha, Jin-Yeol;Kwon, Hye-Jin;Cho, Yong-Chan;Oh, Seung-Hwan;Yoo, Seung-Hwa;Yu, Dong-Su;Park, Yong-Su
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.6
    • /
    • pp.179-190
    • /
    • 2015
  • This study was carried out to suggest fundamental concepts and data ideas for biodiversity and confrontation strategy on global environmental changes by analyzing geomorphic milieu and geotop in Mt. Jeombong experimental forest. Elements of landform were classified as landform sets by scale. Scale for classification could be decide on four categories. We could classify landforms which scale zero is seven elements, scale one is twelve elements, scale two is fifteen elements, scale three is twenty nine elements. Especially mountain wetlands were classed as valley and channel types in Mt. Jeombong. Geotop by clustering methods could be four spatial units as 2, 3, 5, and 7 classes, and analyzed geodiversity as landform sets for explanation of vegetation distribution. Rate of rise of temperature was $0.031^{\circ}C$ per year, change ratio was increased $1.25^{\circ}C$, and also precipitation was increased 320mm during forty year(from year 1973 to year 2012). The result of this research can be affordable to provide information for forest management of mountainous areas.

Study on the Improvement of Milling Recovery and Performance(I) -Operational Factors Affecting Rice Milling Performance- (도정수율과 성능향상을 위한 연구(I) -벼의 도정성능에 영향을 주는 작동요인-)

  • 정창주;류관희;박예린;이성범
    • Journal of Biosystems Engineering
    • /
    • v.5 no.2
    • /
    • pp.1-14
    • /
    • 1980
  • This study was carried out to investigate the effects of the counter-pressure setting and the roller speed of a rice whitening machine on the head rice recovery. milling capacity and milling efficiency, and also to find out the optimum operational conditions of the machine. The radial pressure inside the whitening chamber and the outlet axial pressure were measured to study their relationships with the head rice recovery, milling capacity and milling efficiency. The results of the study are summarized as follows. (1) The most important factor in rice whitening was the counter-pressure setting. It significantly affected the head rice recovery. (2) The roller speed significant affected the milling capacity and milling efficiency , but it did not affected the head rice recovery. (3) Both the radial pressure and the outlet axial pressure were affected by the counter-pressure setting but not by the roller speed. Both of them increased almost linearly with the counter-pressure setting. There was a significant correlation between the radial pressure and the outlet axial pressure. (4) The flow rate through the whitening chamber when the feed gate was fully opened increased with the roller speed, but it was not affected by the counter-pressure setting. (5) The head rice recovery decreased as the counter-pressure setting increased , but it was not affected by the roller speed. The reason could be explained by the fact that the radical pressure increased only with the counter-pressure setting. (6) The milling capacity increased with the counter-pressure setting and linearly with the roller speed. The milling efficiency generally increased with both the counter-pressure setting and the roller speed. However, the effect of roller speed was negligible at the higher counter-pressure setting. The temperature rise inside the whitening chamber was moderate with the mean of 11.3℃ (range 5.6-18.3℃) even though it increased slightly with the roller speed. Considering the head rice recovery and milling efficiency, the optimum operational conditions of the machine appeared to be the counter-pressure setting of 67g/㎠ and the roller speed of 1,050rpm. Neglecting the small difference in the head rice recovery , the greater milling capacity could be obtained at the counter-pressure setting of 85g/㎠ with the roller speed of 850-1050rpm.

  • PDF

Consideration on the Application of Low-Heat Concrete with Ferronickel Slag Aggregate to LNG Storage Tank (페로니켈슬래그 골재를 활용한 저발열 콘크리트의 LNG 저장탱크 적용성 검토)

  • Sang Hyeon Cheong;Sukhoon Pyo;Hyeong-Ki Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.1
    • /
    • pp.17-24
    • /
    • 2024
  • The characteristics of low-heat concrete, mixed with ground blast furnace slag and ferronickel slag aggregate, were analyzed. Moreover, the applicability of this concrete for mass concrete in LNG storage tanks was examined. Initially, the study investigated the characteristics of fresh and hardened concrete. Subsequently, the temperature rising curve was obtained. Utilizing the obtained parameters from the curves, a series of thermal stress analyses for the LNG storage tank were conducted to assess the risk of cracking. The results confirmed that concrete mixtures incorporating ground blast furnace slag and ferronickel slag aggregate not only exhibited sufficient workability but also achieved a compressive strength of approximately 40 MPa within 28 days. Furthermore, the concrete demonstrated a lower terminal heat rise and a faster heat generation rate compared to low-heat Portland cement concrete. An analysis of thermal stress in various sections of the LNG tank validated a low risk of cracking.

Performance Enhancement of Solar-Driven Steam Generator by Local Wettability Control (태양열 활용 증발기의 성능 향상을 위한 국소적 젖음성 제어에 관한 실험적 연구)

  • Choi, Jinwook;Seo, Yongwon;Mo, Hyeong-Uk;Kim, Seolha
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.255-259
    • /
    • 2022
  • Solar membrane steam generation is a very promising technology that can harvest purified water from seawater or wastewater during the current danger of running out of pure water. However, solar Membrane steam generation had direct contact with water, making it difficult to increase the efficient amount of evaporation. Here, we propose solar membrane steam generator composed of polydimethylsiloxane (PDMS) and graphene oxide (GO) and improved evaporation through wettability control in part throughout the water-absorbing membrane. Wettability control has shown significant improvements in thermal localization and temperature rise in the area of heat exchange with sunlight. The evaporator has an evaporation rate of 1.54 kg m-2 h-1 under 1 sun irradiation. The results showed that Solar membrane steam evaporation can effectively harvest pure water through an increase in evaporation.

Thermal-Hydraulic Analysis of Pipeline Transport System for Marine Geological Storage of Carbon Dioxide (이산화탄소 해양지중저장 처리를 위한 파이프라인 수송시스템의 열-유동 해석)

  • Huh, Cheol;Kang, Seong-Gil;Hong, Sup;Choi, Jong-Su;Baek, Jong-Hwa
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.88-94
    • /
    • 2008
  • The concentration of atmospheric carbon dioxide (CO2), which is one of the major greenhouse gases, continues to rise with the increase in fossil fuel consumption. In order to mitigate global warming the amount of CO2 discharge to the atmosphere must be reduced. Carbon dioxide capture and storage (CCS) technology is now regarded as one of the most promising options. To complete the carbon cycle in a CCS system, a huge amount of captured CO2 from major point sources such as power plantsshould be transported for storage into the marine or ground geological structures. Since 2005, we have developed technologies for marine geological storage of CO2,including possible storage site surveys and basic design of CO2 transport and storage process. In this paper, the design parameters which will be useful to construct on-shore and off-shore CO2 transport systems are deduced and analyzed. To carry out this parametric study, we suggested variations in thedesign parameters such as flow rate, diameter, temperature and pressure, based on a hypothetical scenario. We also studied the fluid flow behavior and thermal characteristics in a pipeline transport system.

A Study on the Transition of Hydrogen-Air and LPG-Air Explosion to Fire (수소와 액화석유 가스의 공기혼합기의 폭발 후 화재로 전이 연구)

  • Oh Kyu-Hyung;Lee Sung-Eun;Rhie Kwang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.150-154
    • /
    • 2004
  • Gas explosion characteristics of hydrogen and liquefied petroleum gas(LPG) were measured in 6L cylindrical vessel, and experiment for explosion to fire transition phenomena of the gases were carried out using the 270L vessel. Explosion characteristics were measured using the stain type pressure transducer and explosion to fire transition phenomena was analyzed with the hish-speed camera. Base on the experiment, it was found that explosion pressure was most high slightly above the stoichiometric concentration, and explosion pressure rise rate and flame propagation velocity were proportional to the combustion velocity. And we find that those kind of explosion characteristics affect the explosion-to-fire transition, in addition, explosion flame temperature, flame residence time, are important parameters in explosion-to-fire transition.

Fabrication of $CaSO_4:Eu$ TLD and Its Physical Characteristics ($CaSO_4:Eu$ TLD의 제작과 물리적 특성)

  • Kim, Do-Sung;Park, Myeong-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.388-393
    • /
    • 1999
  • In this study, the $CaSO_4:Eu$ TLDs are fabricated and their trap parameters are determined. The optimum concentration of Eu for fabrication of the $CaSO_4:Eu$ TLD is 0.5 mol% and optimum temperature is $600^{\circ}C$ for 2 hours sintering in air. The glow curve of $CaSO_4:Eu$ consists of two glow peaks and these peaks are isolated by thermal bleaching method. Trap parameters of two glow peaks are measured using the initial rise, the peak shape, the heating rate and the least square curve fitting methods. The activation energies of the glow peak I and II are 1.00 eV and 1.09 eV, and the frequency factors are $7.04{\times}10^{11}\;s^{-1}$ and $5.12{\times}10^{11}\;s^{-1}$ and the kinetic orders are 1.11 and 1.33, respectively.

  • PDF

A Comparative Study on Domestic and Foreign Standards for Air Supply for the Improvement of a Smoke Control System for High-Rise Buildings (국내 고층건축물의 제연설비 성능 개선을 위한 국내·외 급기량 관련 기준 비교연구)

  • Kim, Hye-Won;Lee, Byeong-Heun;Jin, Seung-Hyeon;Lee, Su-Gak;Kim, Jung-Yup;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.105-111
    • /
    • 2019
  • In South Korea, smoke control systems are designed according to the fire safety standards NFSC501 and NFSC 501A. However, there is a problem in that the design values are incompatible when measuring the performance of the system after the design construction for calculating the leakage crack area described in the standards. Therefore, we compared the standards for smoke control systems from South Korea, Japan, and the United Kingdom. In South Korea, designs are conducted uniformly according to the NFSC 501A Manual, but in Japan and the United Kingdom, designs consider smoke temperature, duct loss, and fire floor air supply. Furthermore, they use larger values than in South Korea.

NAPL Removal from Contaminated Soil Using Steam Injection (스팀주입에 의한 토양내 NAPL 제거 실험)

  • Lee, Sang-Il;Jang, Yeon-Su;Kim, Seon-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.5
    • /
    • pp.459-465
    • /
    • 1997
  • The possibility of NAPL removal from contaminated soil was studied using the steam injection technique. Both single (octane, toluene and xylene) and composite NAPL (gasoline) were used as contaminant. Soils used in this study were Chumunjin fine sand and weathered granitic soil, both of which are commonly found in Korea. Experimental results showed that with 1 pore volume steam injection, the NAPL removal rate was in the range of 66∼78% for sand and 45∼73% for weathered granitic soil. The steam injection technique seems to have high potential for soil remediation with advantages of relatively short operating time and no side-effect. Rise in the background temperature led to the delay of steam condensation and the increase of NAPL mobility, which resulted in the improvement of removal efficiency. In addition, water flooding after steam injection turned out to be a very efficient way of removing NAPL residual in the soil pores.

  • PDF

Electrodeposition of Nickel from Nickel Sulphamate Baths (설파민산 니켈 도금욕에서의 니켈 전착)

  • Lee, Hong-Ro;Lee, Dong-Nyung
    • Journal of the Korean institute of surface engineering
    • /
    • v.18 no.3
    • /
    • pp.125-133
    • /
    • 1985
  • About 1 mm thick nickel electrodeposits were obtained from nickel sulphamate baths at 40 to 60$^{\circ}C$ over the range of current densities form 5 to 25 A/$dm^2$. Deposits from above about 1.2V of cathode overpotential had randomly distributed fine grains due to a higher nucleation rate and hence had a high hardness. A deposit obtained at 0.63 V had the [110] orientation with a field oriented fine structure which yield a relatively high hardness. Deposite obtained at the intermediate overpotentials showed the [100] orientation with coarse field oriented structure whose column width tended to decrease with increasing cathode overpotential, which, in turn, gave rise to an increase in hardness. Residual stresses of the deposits measured by X-ray technique were mostly tensile but did not exceed 80 MPa, and were occasionally very small compressive. The cathode current efficiency was above 90% in all the electrolysis conditions, whereas the anode current efficiency varied from 50 to 90% with current density, bath temperature and nickel chloride concentration, among which the chloride was the most influential.

  • PDF