• 제목/요약/키워드: rate of release

검색결과 2,203건 처리시간 0.022초

서방성 Terbutaline sulfate bead의 방출특성 (Release Characteristics of Terbutaline Sulfate Sustained-Release Beads In Vitro)

  • 김기만;김영일;홍순억
    • 한국임상약학회지
    • /
    • 제1권1호
    • /
    • pp.23-30
    • /
    • 1991
  • The sustained-release beads containing terbutaline sulfate (TBS) were prepared by rotogranulation method. The drug was dusted on the non-pareil seeds in a CF-granulator. The sustained-release beads were obtained by coating the active beads with ethylcellulose or $Eudragits^{(R)}$, using in any case the same granulator employed for active beads preparation. The release characteristics of sustained-release beads were examined in vitro by rotating basket method applied to $Bricanyl^{(R)}$ durules which is a sustained-release TBS matrix tablet. The release of terbutaline from the beads in vitro was first-order, and the release rate was dependent on both the coat weight ratio and membrane hydrophilicity. Both surfaces of the beads before and after dissolution were smooth. The drug release pattern from the beads could be thought the diffusion through the polymer membrane. The release rate and the surface of the beads stored for 3 years at room temperature were the same with those of the initial beads.

  • PDF

룸코너 시험기의 발열량 측정에 대한 불확도 산정 (Calculation of Uncertainty in Measuring Heat Release Rate in Room Corner Test)

  • 노광철;김치훈;이승철;이덕희
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.16-22
    • /
    • 2012
  • 화재시험에 있어서 정확한 발열량의 측정은 시험체의 화재 안정성을 결정하기 위한 중요한 정보이다. 발열량 측정값은 측정 인자들의 오차에 기인하여 영향을 받는다. 본 연구에서는 한국철도기술연구원에 설치된 룸코너 시험기에 대한 불확도의 인자를 분석하였고 이를 이용하여 KTX 내장재 화재시험의 발열량 측정 불확도를 계산하였다. 화재 발열량 불확도 계산 결과, 화재시작단계에서 불확도가 매우 높은 값으로 나타났고 화재가 성장하면서 불확도는 점차적으로 감소하였다. 불확도 인자들 중 산소 농도가 발열량 측정 불확도에 가장 크게 기여하는 것으로 나타냈다.

Determination of escape rate coefficients of fission products from the defective fuel rod with large defects in PWR

  • Pengtao Fu
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2977-2983
    • /
    • 2023
  • During normal operation, some parts of the fission product in the defective fuel rods can release into the primary loops in PWR and the escape rate coefficients are widely used to assess quantitatively the release behaviors of fission products in the industry. The escape rate coefficients have been standardized and have been validated by some drilling experiments before the 1970s. In the paper, the model to determine the escape rate coefficients of fission products has been established and the typical escape rate coefficients of noble gas and iodine have been deduced based on the measured radiochemical data in one operating PWR. The result shows that the apparent escape rate coefficients vary with the release-to-birth and decay constants for different fission products of the same element. In addition, it is found that the escape rate coefficients from the defective rod with large defects are much higher than the standard escape rate coefficients, i.e., averagely 4.4 times and 1.8 times for noble gas and iodine respectively. The enhanced release of fission products from the severe secondary hydriding of several defective fuel rods in one cycle may lead to the potential risk of the temporary shutdown of the operating reactors.

피부 부착성 메칠메타크릴레이트-부틸메타크릴레이트 공중합체-포비돈 필름으로부터의 질산에코나졸의 제어 방출 (Controlled Release of Econazole Nitrate from Skin Adhesive Methyl Methacrylate-Butyl Methacrylate Copolymer-Povidone Films)

  • 전인구;이지은
    • Journal of Pharmaceutical Investigation
    • /
    • 제19권3호
    • /
    • pp.145-154
    • /
    • 1989
  • Methyl methacrylate-butyl methacrylate copolymer (MMBM)-povidone (PVP) films were investigated as a potential topical drug delivery system for the controlled release of econazole nitrate as a model drug. The effect of changes in film composition, drug concentration, film thickness, pH and temperature of release medium on the in vitro release of econazole nitrate were studied. The release rate constant was found to be increased with increasing povidone content in dry films. Drug release followed zero-order kinetics in the initial stage and then release rate increased gradually with time, espicially in the films having larger proportions of PVP. The release rate was found to be dependent on drug content, film thickness, the pH and temperature of release medium. Antimicrobial test showed that microbial growth was inhibited markedly with increasing proportions of PVP in films. Also drug content and film thickness affected the antimicrobial activity.

  • PDF

폴리에틸렌옥사이드를 이용한 세파트리진프로필렌글리콜 서방성매트릭스 정제의 제조 및 평가 (Pharmaceutical Formulation and Evaluation of Sustained - Release Hydrophilic Matrix Tablet of Cefatrizine Propyleneglycol Using Polyethylene Oxide)

  • 이언형;박선영;지웅길;김동출
    • Journal of Pharmaceutical Investigation
    • /
    • 제31권1호
    • /
    • pp.37-41
    • /
    • 2001
  • Various characteristics of polyethylene oxide (PEO) are useful for drug delivery systems. In this study, PEO was used as a sustained release matrix system containing cefatrizine propyleneglycol (Cefa-PG) which is a new semi-synthetic broad-spectrum and orally active cephalosporin. Five kinds of sustained release matrix tablets were formulated with various content of PEO and other ingredients. And three types of matrix tablets were formulated of which compositions were the same but the hardness was different. It was found that PEO content influenced drug release rate. Increasing PEO content, the drug release rate from matrix tablets was decreased. In addition, Avicel, one of the ingredients of matrix components, changed the drug release from the sustained release PEO matrix tablets. With increasing Avicel content, the rate of drug release was increased. For the effect of hardness of matrix tablets, the rate of drug release is decreased with increasing hardness. In comparison of bioavailability parameters after oral administration of Cefa-PG PEO matrix tablets and general Cefa-PG capsule in beagle dog, the sustained release PEO matrix tablets is more useful than a general dosage form. $AUC^{0-12}$ of the sustained release PEO matrix tablet and the general dosage form was 1.16 and 0.644 respectively.

  • PDF

핵정(核鐘)에 코팅된 필름층 중에 함유되어 있는 말레인산클로르페니라민의 방출특성 (Dissolution of Chlorpheniramine Mallate (CMP) from Sustained-Release Tablets Containing CPM in the Coated Film Layer)

  • 유제만;심창구;이민화;김신근
    • Journal of Pharmaceutical Investigation
    • /
    • 제20권2호
    • /
    • pp.89-95
    • /
    • 1990
  • Ethylcellulose-PEG 4000 film coated on core tablets was investigated as a potential drug delivery system for the controlled release of chlorpheniramine maleate (CPM). The kinetic analysis of the release data indicated that CPM release followed a diffusion-controlled model, where the quantity released per unit area is proportional to the square root of time. The effect of the film composition, CPM concentration, plasticizer concentration and CPM solubility on the release characteristics were examined. The release rate constant increased as CPM concentration increased. It also increased as the PEG 4000 content in the film increased above 10%(w/w), however, it decreased as the PEG 4000 content increased in the concentration range below 10%(w/w). The release rate constant was not affected by the coated weight on the core tablet. The film-coated tablets which contain CPM only in the coated film layer seemed to be a potential oral drug delivery system for the controlled release of CPM.

  • PDF

The Prediction Methods of Iodine-129 release rate : Model Development

  • Park, Jin-Beak;Lee, Kun-Jai;Kang, Duck-Won;Shin, Sang-Woon;Park, Kyung-Rok
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.879-884
    • /
    • 1995
  • The results of performance assessment analyses have shown that the long-lived radionuclides such as I-129 control the potential individual dose impact to the public. I-129 is difficult-to-measure(DTM) in low-level waste because it is non-gamma emitting radionuclides and exists at extremely low concentrations in radioactive waste generated by nuclear reactors. In this study, computer modeling technique to predict release rate of I-129 is developed to provide another tools far performance assessment of land disposal facilities and characteristics of radwaste. Model suggested in this study will give conservative values of I-129 release rate far determination of radwaste characteristics. More detailed approach is implemented to account for release conditions of fuel source-nuclides. 1-131 concentration measured from reactor coolant and released fraction from tramp fuel have dominant roles in calculating release rate of I-129 with fuel defect conditions.

  • PDF

모래 캡핑 두께가 퇴적물 인 용출에 미치는 영향 (Impact of Thickness of Sand Capping on Phosphorus Release Rate from Sediment)

  • 정우혁;김건하
    • 생태와환경
    • /
    • 제39권3호통권117호
    • /
    • pp.331-339
    • /
    • 2006
  • 본 연구는 퇴적물의 인 용출을 제어하기 위한 방법으로 모래를 이용한 캡핑을 포설할 경우 두께에 따른 인 용출율 저감 효과를 파악하기 위하여 수행되었다. 캡핑은 퇴적물의 인이 수체로 용출되는 속도를 저감시키며, 미생물의 기질소모 이하로 그 속도를 낮추면 수체내의 인의 농도를 일정하게 유지할 수 있음을 알 수 있었다. 모래캡핑의 두께와 용출저감은 선형의 상관관계를 보이며 캡핑 두께가 40 mm에서 80 mm로 두꺼울수록 탈산소계수가 0.311 $day^{-1}$에서 0.262 $day^{-1}$으로 작아지고 있으며, 두께가 증가함에 따라 재폭기 계수는 0.013 $day^{-1}$에서 0.0240 $day^{-1}$으로 커지는 것으로 나타났다. 회귀분석한 결과에 의하면 최소한 20${\sim}$40 mm의 모래캡핑을 실시하더라도 인 용출량을 효율적으로 저감 시킬 수 있는 것으로 나타났다.

Multilayered frame structure subjected to non-linear creep: A delamination analysis

  • Rizov, Victor I.;Altenbach, Holm
    • Coupled systems mechanics
    • /
    • 제11권3호
    • /
    • pp.217-231
    • /
    • 2022
  • The present paper is concerned with a delamination analysis of a multilayered frame structure that exhibits non-linear creep behavior. A solution to the strain energy release rate is obtained by considering the time-dependent complementary strain energy in the frame. The mechanical behavior of the frame is treated by using a non-linear stress-strain-time relationship. The time-dependent solution to the strain energy release rate obtained in the present paper holds for a multilayered frame made of arbitrary number of adhesively bonded layers of different thicknesses and material properties. Besides, the dealamination is located arbitrary along the thickness. The solution to the strain energy release rate is verifiedby applying the J-integral approach. A parametric study of the strain energy release rate is carried-out. Two three-layered frame configurations are analyzed in order to evaluate the influence of the delamination crack location along the thickness on the strain energy release rate. The strain energy release is analyzed also for the case when a notch is cut-out in the inner delamination crack arm. The results obtained are compared with these for a frame without a notch.

The Effect of Solution Pressure to the Release in a Supercooled Aqueous Solution

  • Kang, Chae-Dong;Kim, Byung-Seon;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권1호
    • /
    • pp.25-31
    • /
    • 2009
  • Supercooled type ice storage system with aqueous solution (or water) may have trouble with non-uniform release of supercooling even though it contributes to the simplicity of system and ecological improvement. The non-uniform release increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to suppress the release of the supercooling, a cooling experiment was tried to an ethylene glycol(EG) 3 mass% solution corresponding with pressurization. Also, the frequency ratio of the release of the supercooling was measured to the pressurization from 101 to 505 kPa. At results, the frequency ratio of supercooling release tends to decrease as the pressure of the aqueous solution increased in each cooling rate. Moreover, it tends to decrease as the cooling rate of the solution decreased in each pressure.