• Title/Summary/Keyword: rapid design

Search Result 2,605, Processing Time 0.027 seconds

Luminescent Lanthanide Complexes for Advanced Photonics Applications

  • Eom, Yu Kyung;Ryu, Jung Ho;Kim, Hwan Kyu
    • Rapid Communication in Photoscience
    • /
    • v.1 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Luminescent lanthanide complexes have been overviewed for advanced photonics applications. Lanthanide(III) ions ($Ln^{3+}$) were encapsulated by the luminescent ligands such as metalloporphyrins, naphthalenes, anthracene, push-pull diketone derivatives and boron dipyrromethene(bodipy). The energy levels of the luminescent ligands were tailored to maintain the effective energy transfer process from luminescent ligands to $Ln^{3+}$ ions for getting a higher optical amplification gain. Also, key parameters for emission enhancement and efficient energy transfer pathways for the sensitization of $Ln^{3+}$ ions by luminescent ligands were investigated. Furthermore, to enhance the optophysical properties of novel luminescent $Ln^{3+}$ complexes, aryl ether-functionalized dendrons as photon antennas have been incorporated into luminescent $Ln^{3+}$ complexes, yielding novel $Ln^{3+}$-cored dendrimer complex such as metalloporphyrins, naphthalenes, and anthracenes bearing the Fr$\acute{e}$chet aryl-ether dendrons, namely, ($Er^{3+}-[Gn-Pt-Por]_3$ (terpy), $Er^{3+}-[Gn-Naph]_3$(terpy) and $Er^{3+}-[Gn-An]_3$(terpy)). These complexs showed much stronger near-IR emission bands at 1530 nm, originated from the 4f-4f electronic transition of the first excited state ($^4I_{13/2}$) to the ground state ($^4I_{15/2}$) of the partially filled 4f shell. A significant decrease in the fluorescence of metalloporphyrins, naphthalenes and anthracene ligand were accompanied by a strong increase in the near IR emission of the $Ln^{3+}$ ions. The near IR emission intensities of $Ln^{3+}$ ions in the lanthanide(III)-encapsulated dendrimer complexes were dramatically enhanced with increasing the generation number (n) of dendrons, due to the site-isolation and the light-harvesting(LH) effects. Furthermore, it was first attempted to distinguish between the site-isolation and the light-harvesting effects in the present complexes. In this review, synthesis and photophysical studies of inert and stable luminescent $Ln^{3+}$ complexes will be dealt for the advanced photonics applications. Also, the review will include the exploratory investigation of the key parameters for emission enhancement and the effective energy transfer pathways from luminescent ligands to $Ln^{3+}$ ions with $Ln^{3+}$-chelated prototype complexes.

Evaluation of Correlations in Copier's Button and Usability (복사기 조작버튼에 따른 사용성 상관관계 연구)

  • Ha, Kwang Soo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.595-603
    • /
    • 2013
  • Touchscreen is now installed in the majority of information devices thanks to the developed digital technology. In case of copiers, although touchscreen was installed earlier than any other information device, current user interface indicates that conventional methods have been maintained without any special re-validation. But, since common office devices such as copiers have brief usage time and clear, straightforward purposes, user experience between an user and device is perhaps an important element. Nevertheless, conservativeness of the market and the fact that users and buyers are not always the same are a stumbling block to actively changing UI. Recently, however, as hardware element, buttons, have moved to touchscreen mostly for smartphone, and common and public devices have seen rapid changes in UX, mostly with touchscreen, it has led to high demand for changes in UX of copiers. To remedy the issues with copiers, a literature review was conducted through existing studies and user evaluation based on user survey and prototype was done to examine the copier's UI elements and relevant changes in usage. In particular, a new direction for UX of copiers was suggested by analyzing the impact of differences between software button-oriented UI and hardware button-oriented UI on users and usability. This study findings could be used as basic data for improving the usability of future common devices including copier and UX design.

Use of 16S-23S rRNA Intergenic Spacer Region for Rapid Detection of Vibrio fluvialis (16S-23S rRNA Intergenic Spacer Region을 이용한 Vibrio fluvialis의 검출)

  • 강현실;허문수;이제희
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.1
    • /
    • pp.77-85
    • /
    • 2003
  • We have examined the 16S-23S rRNA intergenic spacer regions (ISR) of Vibrio fluvialis. ISRs were PCR amplified, cloned into a plasmid vector and then sequenced. As results of ISR nucleotide sequence analysis, total of 6 clones were isolated depending on the size. The clones were different in both the number and the composition of the tRNA genes, and were designated ISR-A, ISR-E, ISR-El, ISR-lA, ISR-EKV, ISR-EKAV. ISR-A contains $tRNA^{Ala}$; ISR-lA, $tRNA^{Ile}$-$tRNA^{Ala}$; ISR-EKV, $tRNA^{GIu}$-$tRNA^{Lys}$-$tRNA^{Val}$;ISE-EKAV, $tRNA^{GIu}$-$tRNA^{Lys}$-$tRNA^{Ala}$-$tRNA^{Val}$; ISR -E and E1, $tRNA^{GIu}$ clusters. ISR-EKV was shown to be a minor type out of the six ISR types and showed a very limited homology between ISR-EKV from V, fluvialis and ISRa from other Vibrio species. Therefore ISR-EKV sequence was used to design species-specific primers to detect V, fiuvialis from other Vibrio species by PCR reaction. The specificity of the primers was examined using genomic DNA of other Vibrios as templates for PCR reaction. The result showed that PCR can be a useful method to detect V. fluvialis among Vibrio species in a single PCR reaction.

Prediction of Water Level at Downstream Site by Using Water Level Data at Upstream Gaging Station (상류 수위관측소 자료를 활용한 하류 지점 수위 예측)

  • Hong, Won Pyo;Song, Chang Geun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.28-33
    • /
    • 2020
  • Recently, the overseas construction market has been actively promoted for about 10 years, and overseas dam construction has been continuously performed. For the economic and safe construction of the dam, it is important to prepare the main dam construction plan considering the design frequency of the diversion tunnel and the cofferdam. In this respect, the prediction of river level during the rainy season is significant. Since most of the overseas dam construction sites are located in areas with poor infrastructure, the most efficient and economic method to predict the water level in dam construction is to use the upstream water level. In this study, a linear regression model, which is one of the simplest statistical methods, was proposed and examined to predict the downstream level from the upstream level. The Pyeongchang River basin, which has the characteristics of the upper stream (mountain stream), was selected as the target site and the observed water level in Pyeongchang and Panwoon gaging station were used. A regression equation was developed using the water level data set from August 22th to 27th, 2017, and its applicability was tested using the water level data set from August 28th to September 1st, 2018. The dependent variable was selected as the "level difference between two stations," and the independent variable was selected as "the level of water level in Pyeongchang station two hours ago" and the "water level change rate in Pyeongchang station (m/hr)". In addition, the accuracy of the developed equation was checked by using the regression statistics of Root Mean Square Error (RMSE), Adjusted Coefficient of Determination (ACD), and Nach Sutcliffe efficiency Coefficient (NSEC). As a result, the statistical value of the linear regression model was very high, so the downstream water level prediction using the upstream water level was examined in a highly reliable way. In addition, the results of the application of the water level change rate (m/hr) to the regression equation show that although the increase of the statistical value is not large, it is effective to reduce the water level error in the rapid level rise section. Accordingly, this is a significant advantage in estimating the evacuation water level during main dam construction to secure safety in construction site.

Validation of an HPLC Method for the Pharmacokinetic Study of Glipizide in Human (글리피짓 체내동태 연구를 위한 혈청 중 글리피짓의 HPLC 정량법 검증)

  • Cho, Hea-Young;Lee, Hwa-Jeong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.3
    • /
    • pp.137-142
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of glipizide in human serum was validated and applied to the pharmacokinetic study of glipizide. Glipizide and internal standard, tolbutamide, were extracted from human serum by liquid-liquid extraction with benzene and analyzed on a Nova Pak $C_{18}\;60{\AA}$ column with the mobile phase of acetonitrile-potassium dihydrogen phosphate (10 mM, pH 3.5) (4:6, v/v). Detection wavelength of 275 nm and flow rate of 0.7 ml/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed glipizide concentration (500 ng/ ml) with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 10-1000 ng/ml with correlation coefficient greater than 0.999. The lower limit of quantitation using 0.5 ml of serum was 10.0 ng/ml, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 82.6 to 105.0% for glipizide with overall precision (% C.V.) being 1.13-13.20%. The percent recovery for human serum was in the range of 85.2 93.5%. Stability studies showed that glipizide was stable during storage, or during the assay procedure in human serum. The peak area and retention time of glipizide were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of glipizide in human serum samples for the pharmacokinetic studies at three different laboratories, demonstrating the suitability of the method.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Fexofenadine in Human (테르페나딘 체내동태 연구를 위한 혈청 중 펙소페나딘의 HPLC 정량법 개발 및 검증)

  • Cho, Hye-Young;Kang, Hyun-Ah;Kim, Yoon-Gyoon;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.6
    • /
    • pp.437-443
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of a major metabolite of terfenadine, fexofenadine, in human serum was developed, validated, and applied to the pharmacokinetic study of terfenadine. Fexofenadine and internal standard, haloperidol were extracted from human serum by liquid-liquid extraction with acetonitrile and analyzed on a $Symmetry^{TM}$ C8 column with the mobile phase of 1% triethylamine phosphate (pH 3.7)-acetonitrile (67:33, v/v, adjusted to pH 5.6 with triethylamine). Detection wavelength of 230 nm for excitation, 280 nm for emission and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed fexofenadine concentration (50 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 10-500 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 10 ng/mL, which was sensitive enough for the pharmacokinetic studies of terfenadine. The overall accuracy of the quality control samples ranged from 95.70 to 114.58% for fexofenadine with overall precision (% C.V.) being 3.53-14.39%. The relative mean recovery of fexofenadine for human serum was 90.17%. Stability studies (freeze-thaw, short-term, extracted serum sample and stock solution) showed that fexofenadine was stable during storage, or during the assay procedure in human serum. However, the storage at $-70^{\circ}C$ for 4 weeks showed that fexofenadine was not stable. The peak area and retention time of fexofenadine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of fexofenadine in human serum samples for the pharmacokinetic studies of orally administered Tafedine tablet (60 mg as terfenadine) at three different laboratories, demonstrating the suitability of the method.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Etodolac in Human (에토돌락 체내동태 연구를 위한 혈청 중 에토돌락의 HPLC 정량법 개발 및 검증)

  • Cho, Hea-Young;Kang, Hyun-Ah;Moon, Jai-Dong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.4
    • /
    • pp.265-271
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of etodolac in human serum was developed, validated, and applied to the pharmacokinetic study of etodolac. Etodolac and internal standard, ibuprofen were extracted from human serum by liquid-liquid extraction with hexane/isopropanol (95:5, v/v) and analyzed on a Luna C18(2) column with the mobile phase of 1% aqueous acetic acid-acetonitrile (4:6, v/v). Detection wavelength of 227 nm and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed etodolac concentration $(1\;{\mu}g/mL)$ with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of $0.05-40\;{\mu}g/mL$ with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 0.05 ${\mu}g/mL$, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 92.00 to 110.00% for etodolac with overall precision (% C.V.) being 1.08-10.11%. The percent recovery for human serum was in the range of 76.73-115.30%. Stability studies showed that etodolac was stable during storage, or during the assay procedure in human serum. The peak area and retention time of etodolac were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of etodolac in human serum samples for the pharmacokinetic studies of orally administered Lodin XL tablet (400 mg as etodolac) at three different laboratories, demonstrating the suitability of the method.

Investigation on sample throughput of large scale splitter-less gravitational SPLITT fractionation (GSF) (Large scale Gravitational SPLITT Fractionation (GSF)에서의 시료 throughput에 관한 연구)

  • Choi, Hyo Jae;Kim, Woon Jung;Eum, Chul Hun;Lee, Seungho
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.34-41
    • /
    • 2013
  • Split-flow thin cell (SPLITT) fractionation (SF) is a rapid separation technique capable of separating colloidal particles or macromolecules into two or more fractions. SF allows fractionations in a preparative scale as sample is fed continuously. Generally SF uses a thin ribbon-like channel equipped with two flow stream splitters at the inlet and outlet of the channel. Thus there exist two flow inlets and two flow outlets at the top and bottom of the inlet and outlet of the channel, respectively. There are two operating modes in SF, conventional mode and full-feed mode (FFD). Although the resolution in the FFD mode is lower than that in the conventional mode, FFD mode has some merits. The design of the channel and operation are simpler in the FFD mode, as it does not require the feeding of the solvent. Thus there is no flow stream splitter at the channel inlet, and only one pump is needed, unlike the conventional mode, where two pumps are required for the feedings of the sample and the solvent separately. Also the sample is not diluted in the FFD mode as there is no solvent feeding, which is important for fractionation samples with low colloidal concentrations such as environmental samples. For some of environmental samples, pre-concentration is often required. In this study, a new large-scale splitter-less FFD-SF channel was implemented, where there is no splitter at the outlet as well as at the inlet of the channel. It was possible to build the channel in a much larger dimension than conventional ones, allowing much higher sample throughput (TP). The new channel was tested and optimized with polyurethane (PU) latex beads, and then applied to large-scale separation of Polyacrylate (PA).

Design and Implementation of Web-based Problem Management System for CT Radiological Technologist Education (CT 전문방사선사 교육을 위한 웹기반 문항관리 시스템의 설계 및 구현)

  • Shin Yong-Won;Koo Bong-Oh;Shim Choon-Bo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.1
    • /
    • pp.27-35
    • /
    • 2005
  • Recently, despite of the rapid progress of information technology in the medical and health fields, the development and management of problem sets about medical and education contents related with radiological technologist has been still achieved by manual and offline method using document editor. In this study, the unique web-based problem management system is designed and implemented. That system can efficiently manage and present various kind of problem set about integrated education and personal license without time and space limitations in order to improve the efficiency of supplementary training and to obtain the professional license for CT radiological technologist. The proposed system is composed of administration module and user module. The former supports several functions such as problem creation, problem categorization, user management, and adjustment of leveled assessment. On the other hand, the latter functions examination applying , problem retrieval, personal score retrieval, and interpretation viewing, and so on. In addition, our system is expected as a useful and practical system which provides problem interpretation and analysis of score results after applying for the examination. It can elevate ability of learning and information interchange among them preparing for CT professional radiological technologist licensing examination

  • PDF

A Study on Switching Intention of Broadcasting Service to MCN Service by Migration Theory (새로운 방송 서비스로의 이전 : 이주 이론을 통한 MCN으로 전환의도 연구)

  • Kim, Yonghee
    • The Journal of Industrial Distribution & Business
    • /
    • v.10 no.1
    • /
    • pp.59-67
    • /
    • 2019
  • Purpose - The Millennial Generation, which grew in the wake of the spread of the Internet and rapid changes in the media environment, is rapidly moving from the traditional broadcasting environment to the Internet-broadcasting environment in terms of content acceptance. With the emergence of UGC (User-generated content), the change in the status of single-person content creators enables the growth of multi-channel networks (MCN), a new content-distribution platform and an agency concept for single creators. Youtube-based MCN produces multiple single star producers and casts and provides its own video series through Youtube. It is also emerging as a major M&A target for global media providers in terms of providing content to a wide range of consumers with the same interests and consumption characteristics. In addition, for the Millennials generation, which are part of their lives, MCN is becoming the most suitable media for TGIF (Twitter, Google, i-phone, Facebook). Accordingly, this study defines newly emerging MCNs and analyzes the factors for accepting MCN-produced content based on the push-pull-mooring (PPM) model. Research design, data, and methodology - An empirical analysis is performed through a questionnaire survey. For this purpose, 204 people who have experience of watching MCN were studied. Collected data is processed through analysis of a structural equation model using R to test the hypothesis. Results - For the MCN service to become an alternative to existing media, it is necessary to continuously promote cultural diversity and diversity of attempts that conventional media cannot provide. It is the attractiveness of the alternative that has the greatest influence on the intention to switch to a MCN service. When we look at MCN content so far, certain patterns such as game progress, introduction, food, and chat rooms have already appeared. We need to overcome this and develop a completely new conceptual content that we have never seen before. This requires a more generous viewer perception of the topics covered. For diversity, linguistic and verbal violence should be tolerant in common sense to provide a foundation for securing cultural diversity. Conclusions - In this study, we tried to develop a comprehensive approach to the substitution effect of MCN. In terms of academic achievement, the PPM model is used to enhance the utilization of media and broadcasting. Practical implications are to provide an analytical framework for verifying alternative or complementary effects when viewers switch to MCN.