• Title/Summary/Keyword: range scaling

Search Result 211, Processing Time 0.034 seconds

Performance Simulation of a Turboprop Engine for Basic Trainer

  • Kong, Changduk;Ki, Jayoung;Chung, Sukchoo
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.839-850
    • /
    • 2002
  • A performance simulation program for the turboprop engine (PT6A-62), which is the power plant of the first Korean indigenous basic trainer KT-1, was developed for performance prediction, development of an EHMS (Engine Health Monitoring System) and the flight simulator. Characteristics of components including compressors, turbines, power turbines and the constant speed propeller were required for the steady state and transient performance analysis with on and off design point analysis. In most cases, these were substituted for what scaled from similar engine components'characteristics with the scaling law. The developed program was evaluated with the performance data provided by the engine manufacturer and with analysis results of GASTURB program, which is well known for the performance simulation of gas turbines. Performance parameters such as mass flow rate, compressor pressure ratio, fuel flow rate, specific fuel consumption and turbine inlet temperature were discussed to evaluate validity of the developed program at various cases. The first case was the sea level static standard condition and other cases were considered with various altitudes, flight velocities and part loads with the range between idle and 105% rotational speed of the gas generator. In the transient analysis, the Continuity of Mass Flow Method was utilized under the condition that mass stored between components is ignored and the flow compatibility is satisfied, and the Modified Euler Method was used for integration of the surplus torque. The transient performance analysis for various fuel schedules was performed. When the fuel step increase was considered, the overshoot of the turbine inlet temperature occurred. However, in case of ramp increase of the fuel longer than step increase of the fuel, the overshoot of the turbine inlet temperature was effectively reduced.

Characteristics of Noise Radiated at Dental Clinic (치과병원에서 치료시 발생하는 소음특성)

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.12
    • /
    • pp.1123-1128
    • /
    • 2009
  • Noise radiated from medical treatment at dental clinic will affect the patients. On such point of view, We investigated the noise characteristics in case of medical treatment (scaling, tooth eliminating) and non-medical examination (idling) and also evaluated the degree of indoor noise using the evaluation index such as PSIL, NRN and made up a questionnaire about the reactions to noise. As a result of noise evaluation, it shows that the range of noise level is 67.7~78.3 dB(A) and frequency is very high (above 4 k Hz) and respondents are affected by noise (unpleasantness, hesitation to visit dental clinic, shivering with noise, being astonishment). Analysis by PSIL showed that it was no problem to conversation between worker and patient. But it exceeded the noise permit level in working space by NR-curve. To relieve a fear of noise in patients, they are considered to offer the ear protection, choose the low noisevibration equipment and use the masking effect. They are of great advantage to dental clinics to i prove dental service and competitiveness.

A Development of Intelligent Decision System by Safely Distance of GAS Storage Tank (가스 저장탱크 안전거리의 지적 결정 시스템 개발)

  • Leem Sa-Hwan;Huh Yong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.721-726
    • /
    • 2006
  • This paper is on intelligent decision system by safety distance of gas storage tank(IDSG). The safety distance fixed up by law is used to prevent from the injury by explosion of storage tank on the spot. However, it is not easy for a layman to decide a proper safety distance considering the size, shape and place of the storage tank. Therefore, this thesis shows the user-friendly intelligent decision system which a layman can decide the Bas related law, the size, shape and place of the storage tank by the intelligent decision, and it is to make assurance doubly sure for safety supervision on the spot. Also, the paper can make the data for the damage influence distance of overpressure by the explosion of the storage tank calculated by the scaling law of Hopkinson with the fixed distance by law, and safety range can be grasped with the graphic which is printed by the PHAST(Process Hazard Analysis Software Tool) model using this data.

  • PDF

Relationships among Knowledge, Attitude, and Use of Negative Control Maintenance Techniques Toward Older Adults among Nurses Working in Geriatric Hospitals (노인병원 간호사의 노인에 대한 지식과 태도 및 부정적 행동통제기술의 사용정도 간의 관계)

  • Park, Hyang Sook;Suh, Soon Rim;Kim, Su Hyun
    • Korean Journal of Adult Nursing
    • /
    • v.19 no.4
    • /
    • pp.614-623
    • /
    • 2007
  • Purpose: The purpose of this study was to examine the relationships among knowledge, attitudes, and the use of negative control maintenance techniques toward older adults among nurses working in geriatric hospitals (n=86). Methods: Data were collected from April 4th to May 30th in 2006 by using questionnaires of Fact on Aging Quiz Part I, Aging Semantic Differential Scaling, and Control Maintenance Techniques. Results: The findings showed that the nurses displayed lack of knowledge concerning older adults and their average rate of correct answer was 45.6%. They also hold some negative bias and attitudes, especially in psychological and social aspects. The level of using negative control maintenance techniques in managing older patients' problematic behaviors was reported as the mean of 5.65 with a possible range of 0-40. Nurse's knowledge of older adults was positively associated with their attitudes toward older adults, but their knowledge and attitudes were not associated with the use of negative control maintenance techniques. Conclusion: It is necessary to provide educational programs for nurses that focus on a comprehensive understanding of aging with lifetime developmental perspectives. Further studies are needed to understand the factors associated with using negative control maintenance techniques and to evaluate the intervention programs in reducing the use of negative control maintenance techniques.

  • PDF

Surgical Treatment of Pancreatic Trauma in Children (소아의 외상성 췌장 손상의 수술적 치료)

  • Cho, Jae-Hyung;Kim, Hyun-Young;Jung, Sung-Eun;Park, Kwi-Won
    • Advances in pediatric surgery
    • /
    • v.19 no.2
    • /
    • pp.98-107
    • /
    • 2013
  • Debates exist about the appropriate treatment for pancreatic trauma in children. We intended to examine the safety of the operation of pancreatic trauma in children. This is a retrospective study of 13 patients, younger than 15, who underwent surgery for pancreatic trauma, between 1993 and 2011 in Seoul National University Children's Hospital. Medical records were reviewed for mechanism of trauma, clinical characteristics, radiological findings, operation and outcomes. Organ injury scaling from the AAST (American Association for Surgery of Trauma) was used. All injuries were caused by blunt trauma. Patients with grade III, IV, and those who were difficult to distinguish grade II from IV, underwent surgery due to severe peritonitis. Three patients with grade II were operated for reasons of mesenteric bleeding, tumor rupture of the pancreas, and progression of peritonitis. Distal pancreatectomy was performed in 10 patients and subtotal pancreatectomy and pylorus preserving pancreaticoduodenectomy in 1 patient each. The remaining one underwent surgical debridement because of severe adhesions. The location of injury, before and after operation, coincided in 83.3%. The degree of injury, before and after the operation, was identical in all the patients except for those who were difficult to tell apart grade II from grade IV, and those cannot be graded due to severe adhesion. Postoperative complications occurred in 23.1%, which improved with conservative treatment. Patients were discharged at mean postoperative 12(range 8~42) days. Even though patients with complications took longer in time from diagnosis to operation, time of trauma to operation and hospital stay, this difference was not significant. In conclusion, When pancreatic duct injury is present, or patient shows deterioration of clinical manifestation without evidence of definite duct injury, or trauma is accompanied by other organ injury or tumor rupture, operative management is advisable, and we believe it is a safe and feasible method of treatment.

Mock-up Test for Field Application of a Polylon Fiber Method (폴리론 화이버 공법의 현장적용을 위한 Mock-up Test)

  • Kwon, Hae-Won;Son, Ho-Jung;Jee, Suk-Won;Lee, Byeong-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.405-408
    • /
    • 2008
  • This study, as mock-up test for applying Polylon Fiber engineering method to the field, analyzed the fundamental characteristics and the fireproof characteristics of high strength concrete mixed with Polylon Fiber 0.05% and the results are summarized as followings. From the characteristic of the fresh concrete, both slump flow and air content were appeared to satisfy target range. And from the characteristic of hardened concrete, all compressive strengths according to the curing conditions were appeared to satisfy design standard strength of 60 MPa. From the fireproof characteristic, small scaling and spalling phenomenon were partially appeared on the surface part of specimens, but generally the excellent fireproof capacities were appeared. From the characteristic of temperature hysteresis, the highest temperature and the average temperature of reinforcing part after fire-resistant test for 3 hours were $531^{\circ}C$ and $405{\circ}C$, respectively and then satisfied fireproof standard of the Ministry of Land Transportation and Maritime Affairs.

  • PDF

Design of the 5th-order Elliptic Low Pass Filter for Audio Frequency using CMOS Switched Capacitor (CMOS 스위치드 캐패시터 방식의 가청주파수대 5차 타원 저역 통과 여파기의 설계 및 구현)

  • Song, Han-Jung;Kwack, Kae-Dal
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.1
    • /
    • pp.49-58
    • /
    • 1999
  • This paper describes an integrated low pass filter fabricated by using $0.8{\mu}m$ single poly CMOS ASIC technology. The filter has been designed for a 5th-order elliptic switched capacitor filter with cutoff frequency of 5khz, 0.1dB passband ripple. The filter consists of MOS swiches poly capacitors and five CMOS op-amps. For the realization of the SC filter, continuous time transfer function H(s) is obtained from LC passive type, and transfered as discrete time transfer H(z) through bilinear-z transform. Another filter has been designed by capacitor scaling for reduced chip area, considering dynamic range of the op-amp. The test results of two fabricated filters are cutoff frequency of 4.96~4.98khz, 35~38dB gain attenuation and 0.72~0.81dB passband ripple with the ${\pm}2.5V$power supply clock of 50KHz.

  • PDF

Type I von Willebrand Disease in a Maltese (한국내 말티즈에서 발생한 제 1형 폰 빌레브란트병 증례)

  • Kim, Seung-Gon;Kang, Min-Hee;Lee, Kyo-Im;Kim, Ha-Jung;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.359-362
    • /
    • 2013
  • A 6-year-old castrated male Maltese weighing 4.16 kg presented with a history of bleeding from the mouth after scaling and dental extraction 2 days prior. The von Willebrand factor antigen (vWf:Ag) level was 54% (reference range, 70-180%), indicating that the dog was homozygous for an inherited von Willebrand disease (vWD). The dog received whole-blood transfusion as initial treatment, consequently showing markedly improved clinical signs, and is currently in good condition. To our knowledge, this is the first reported case of type 1 vWD in a Maltese in Korea.

A Study of Globular Cluster Systems in the Coma, Fornax, and Virgo Clusters of Galaxies from HST ACS and WFC3/IR Imaging

  • Cho, Hyejeon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.29.1-29.1
    • /
    • 2017
  • I present new near-infrared (NIR) photometry of globular cluster (GC) systems associated to a cD galaxy NGC 4874 in the core of the Coma cluster and 16 early-type galaxies in the Fornax and Virgo clusters of galaxies using the Infrared Channel of the Wide Field Camera 3 (WFC3/IR) on board the Hubble Space Telescope (HST). Combining these high-resolution NIR data with new HST Advanced Camera for Surveys (ACS) optical photometry for NGC 4874 and existing ACS GC catalogs from the ACS Fornax and Virgo Cluster Surveys, I have examined for the first time the GC systems in a statistically significant optical/NIR sample of galaxies spanning a wide range of luminosities and colors. A primary goal of this study is to explore empirically whether the distributions of purely optical and hybrid optical - NIR color indices for extragalactic GCs have different forms and whether the relations between these color indices are nonlinear, indicating that they behave differently with underlying metallicity. I find that some GC systems of large galaxies in our sample show color bimodalities that differ between the optical and optical - NIR colors, in the sense that they have disparate ratios of "blue" and "red" peak GCs, as well as differing ratios in their color dispersions. Consistent with these results, I find empirically that the dependence of hybrid optical-NIR color on purely optical color is nonlinear, with an inflection at intermediate metallicities. These findings underscore the importance of understanding the nature of galaxy-to-galaxy variations in the GC color distributions and color-color relations, as well as the exact forms of the color-metallicity transformations, in interpreting the observational data on GC color bimodality. Our ACS data for NGC 4874 shows that its GC system exhibits a very strong blue tilt, implying a very steep mass-metallicity scaling, and the centroid of this GC system is offset by $4{\pm}1kpc$ from the luminosity center of NGC 4874, in the direction of NGC 4872. Finally, I discuss the asymmetrical GC distribution around a dwarf elliptical galaxy in Coma that has a very high relative velocity with respect to the cluster mean at small clustercentric radius.

  • PDF

Distribution Patterns of Sandy Bottom Macrobenthic Community on the Hupo Coastal Area, in the East Sea of Korea (동해 후포주변 사질조하대에 서식하는 대형저서동물군집의 분포특성)

  • Paik, Sang-Gyu;Kang, Rae-Seon;Jeon, Jae-Ok;Lee, Jae-Hac;Yun, Sung-Gyu
    • Ocean and Polar Research
    • /
    • v.29 no.2
    • /
    • pp.123-134
    • /
    • 2007
  • Distribution patterns of sandy bottom macrobenthic communities were studied around the Hupo coastal area. The seasonal surveys were conducted at 15 chosen sites within a depth range of 10 to 50 m along 10 km of the coastline using a Smith-McIntyre grab $(0.05\;m^2)$ in 2005. Overall depth distribution following the direction of the offshore become deeper parallel to the coastline. A total of 319 macrobenthic species were sampled with a mean density of $1,972\;ind./m^2$, and mean biomass was 82.5 wet-weight $g/m^2$. The major individual-dominant species were three polychaetes Spiophanes bombyx ($436\;ind./m^2$), Scoletoma longifolia ($250\;ind./m^2$) and Magelona japonica ($170\;ind./m^2$), and bivalve Adontorhina subquadrata ($73\;ind./m^2$). Cluster analysis and non-metric multidimensional scaling (nMDS) analysis based on Bray-Curtis similarity identified 2 major station groups which corresponded to macrobenthic faunal assemblages and their characteristic species. In addition, environmental conditions were significantly different between station groups. Group I contained mostly 20 and 50 m deep sites and was associated with sandy mud. Group I was characterized by high abundance of S. bombyx, S. longifolia, A. subquadrata. It was divided into two sub-groups (I-I and I-II) in relation to depth. Sub-group I-I was associated with deeper sites than sub-group I-II. Group II included mostly inshore area shallower than 15 m and was associated with coarse and medium sand. Group II was characterized by Lumbrinerides hayashii and Urothoe grimaldii japonica.