• Title/Summary/Keyword: range of motion

Search Result 3,076, Processing Time 0.028 seconds

Functional analysis of isolated posterior cruciate ligament deficient subjects (후방 십자 인대 단독 손상 환자의 기능적 분석)

  • Kim Jin Goo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.1
    • /
    • pp.66-72
    • /
    • 2004
  • Purpose: To evaluate the compensatory mechanism in vivo and develop the treatment guide by performing the comprehensive functional tests of the posterior cruciate ligament (PCL) deficient subjects. Material and Methods: 10 PCL deficient subjects and 10 healthy control group were evaluated. Performed functional tests were range of motion, posterior drawer test, Telos, 30$^{\circ}$ flexion wt-bearing view, KT-1000 arthrometer, gait analysis, EMG test and isokinetic tests. Results: Physical, KT-1000, Telos posterior tests showed significant differences, but 300 full weight bearing lateral view, muscle strength test revealed no difference between two groups. Less knee flexion at initial contact and reduced maximum valgus moment were observed in PCL deficient group. In vertical drop landing, PCL group had increased plantar flexion angle at initial contact. Conclusion: Compensatory mechanisms such as reduced unstable components and absorbing the maximal load of the joint were occurred after PCL insufficiency, which result in good clinical and functional outcomes. Further investigations would be needed to understand the functional adaptations of PCL deficient subjects.

  • PDF

The Effect of Additional Mobilization with Conservative Physical Therapy in Patients with Frozen Shoulder on ROM and Subjective Pain Scale (동결 견 환자에 대한 보존적 물리치료와 관절 가동술의 병행이 주관적 통증지수와 관절가동범위에 미치는 효과)

  • Hyong, In-Hyouk;Ha, Mi-Sook
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.271-279
    • /
    • 2009
  • Frozen shoulder is clinically characterized by pain and reduced ROM. The therapeutic goal of frozen shoulder can be reducing pain and increasing ROM in shoulder joint, resulting in improvement of joint movement. Therefore, this study was conducted to know the effect of mobilization in parallel with conservative physical therapy(H/P, TENS, U/S) in patients with frozen shoulder on subjective pain scale and ROM. 26 patients diagnosed with frozen shoulder were included for study. Among them, 13 patients(experiment group) were managed by mobilization as well as conservative physical therapy, another 13 patients(control group) were only treated by conservative physical therapy alone. All the patients were treated three times a week for 4 weeks, and after each treatment subjective pain scale and ROM were measured. In experimental group, pain has decreased and ROM has increased in abduction, external rotation and internal rotation. In control group, pain has also decreased but ROM has not changed in abduction, external rotation and internal rotation. There were no significant difference in subjective pain scale between two groups but some difference in ROM (external rotation, internal rotation). According to the results, we concluded that both conservative physical therapy and joint mobilization technique are more effective for increasing ROM especially external rotation, internal rotation than conservative physical therapy alone.

New Decision Rules for UWB Synchronization (UWB 동기화를 위한 새로운 결정 법칙들)

  • Chong, Da-Hae;Lee, Young-Yoon;Ahn, Sang-Ho;Lee, Eui-Hyoung;Yoo, Seung-Hwan;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2C
    • /
    • pp.192-199
    • /
    • 2008
  • In ultra-wideband (UWB) systems, conventionally, the synchronization is to align time phases of a locally generated template and any of multipath components to within an allowable range. However, the synchronization with a low-power multipath component could incur significant performance degradation in receiver operation (e.g., detection) after the synchronization. On the other hand, the synchronization with a high-power multipath component can improve the performance in receiver operation after the synchronization. Generally, the first one among multipath components has the largest power. Thus, the synchronization with the first path component can make better performance than that with low-power component in receiver operation after the synchronization, Based on which, we first propose an optimal decision rule based on a maximum likelihood (ML) approach, and then, develope a simpler suboptimal decision rule for selecting the first path component. Simulation results show that the system has good demodulation performance, which uses new synchronization definition and the proposed decision rules have better performance than that of the conventional decision rule in UWB multipath channels. Between macroblocks in the previous and the current frame. On video samples with high motion and scene change cases, experimental results show that (1) the proposed algorithm adapts the encoded bitstream to limited channel capacity, while existing algorithms abruptly excess the limit bit rate; (2) the proposed algorithm improves picture quality with $0.4{\sim}0.9$dB in average.

Prophylactic Radiotherapy to Prevent the Recurrence of Heterotopic Ossification after Surgical Intervention of the Elbow (주관절에서 이소성 골형성의 재발방지를 위한 예방적 방사선 치료)

  • Kim, Hak-Jae;Kim, Jin-Ho;Kim, Kyu-Bo;Choi, Ja-Young;Chung, Moon-Sang;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.206-212
    • /
    • 2007
  • Purpose: Heterotopic ossification is a well-known postoperative and post-traumatic complication of the elbow. We reviewed the treatment outcome for the use of low-dose radiation after surgical intervention of the elbow to prevent recurrence of heterotopic ossification (HO). Materials and Methods: Forty-five patients with HO underwent surgical intervention and postoperative radiotherapy of the elbow. The median age of the patients was 29 years ($16{\sim}75$ years), and 27 of the patients were men and 18 were women. The occurrence of HO was mainly due to surgery after fracture (24/45) and traumatic injury (21/45). Limitation of the range of motion (ROM) was the most common symptom of the patients. Thirty-four patients received postoperative radiotherapy with a dose of 8 Gy in 2 fractions; 5 patients received a dose of 10 Gy in 5 fractions and 6 patients received a dose of 7 Gy in 1 fraction. Postoperative radiotherapy was given on the first two postoperative days for most of the patients. Sixteen patients were not given anti-inflammatory medication and 29 patients were given NSAIDs for $1{\sim}8$ months. Results: After a median follow-up period of 18 months (range $6{\sim}72$ months), 41 patients showed clinical improvement and two patients did not show improvement. Assessment of the ROM showed a mean improvement from $0{\sim}135^{\circ}$ to $60{\sim}145^{\circ}$ (p=0.028), and assessment of the functional outcome according to MEPI was from ($15{\sim}95$) to ($80{\sim}100$) (p<0.0001). Two of the 34 patients that were followed-up with radiography had mild radiological recurrence of heterotopic ossification. No complications were observed after the radiotherapy. Conclusion: These results suggested that low-dose radiation administered after surgical intervention is safe and effective to prevent the recurrence of HO in the elbow.

Ultrasound-Guided Local Steroid Injection Therapy for Acute Calcific Tendinitis of Shoulder (초음파를 이용한 급성 극상근 석회화 건염의 스테로이드 국소 주사 요법)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Kang, Min-Ku
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.85-89
    • /
    • 2009
  • Purpose: To analyze the clinical outcome after ultrasound guided multiple dry needlings and local steroid injection for acute calcific tendinitis of shoulder. Materials and Methods: Twenty patients with acute episode of pain by calcific tendinitis of shoulder with average age 58.2 (50~70 years) and follow-up of 18 months in average (range, 12~24) were included in study. There were 18 patients with right and 2 with left sided involvement. All patients had calcific deposits in the supraspinatus tendon. All patients underwent standardized nonoperative treatment protocol, consisting of 5~12 MHz high resolution ultrasound guided multiple dry needlings with 18 guage needle, followed by 2% lidocaine 1cc and 40 mg/ml depomedrol 1cc injection at site of calcific tendinitis. The outcome was assessed by UCLA shoulder score, range of motion and VAS score. A statistical analysis with ANOVA and Tukey's post-hoc test with the significance level at 5% was performed using SAS 9.1 software (SAS Institute, Cary, NC). Results: All patients got continuous relief of pain right after the procedures until final follow-up. Before the procedures, the UCLA scores were fair in 15 patients and poor in 5. After the procedures, the UCLA scores were excellent in 16 patients and good in 4. All cases revealed no limitation of shoulder function. The average VAS score decreased from 8.9 before the procedures to 0.5 at final follow-up (p<0.0001). No complication was encountered. Conclusion: An ultrasound guided local steroid injections following multiple dry needlings would be one of the useful treatment modality for the acute calcific tendinitis of shoulder.

  • PDF

Development of 3D Impulse Calculation Technique for Falling Down of Trees (수목 도복의 3D 충격량 산출 기법 개발)

  • Kim, Chae-Won;Kim, Choong-Sik
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.2
    • /
    • pp.1-11
    • /
    • 2023
  • This study intended to develop a technique for quantitatively and 3-dimensionally predicting the potential failure zone and impulse that may occur when trees are fall down. The main outcomes of this study are as follows. First, this study established the potential failure zone and impulse calculation formula in order to quantitatively calculate the risks generated when trees are fallen down. When estimating the potential failure zone, the calculation was performed by magnifying the height of trees by 1.5 times, reflecting the likelihood of trees falling down and slipping. With regard to the slope of a tree, the range of 360° centered on the root collar was set in the case of trees that grow upright and the range of 180° from the inclined direction was set in the case of trees that grow inclined. The angular momentum was calculated by reflecting the rotational motion from the root collar when the trees fell down, and the impulse was calculated by converting it into the linear momentum. Second, the program to calculate a potential failure zone and impulse was developed using Rhino3D and Grasshopper. This study created the 3-dimensional models of the shapes for topography, buildings, and trees using the Rhino3D, thereby connecting them to Grasshopper to construct the spatial information. The algorithm was programmed using the calculation formula in the stage of risk calculation. This calculation considered the information on the trees' growth such as the height, inclination, and weight of trees and the surrounding environment including adjacent trees, damage targets, and analysis ranges. In the stage of risk inquiry, the calculation results were visualized into a three-dimensional model by summarizing them. For instance, the risk degrees were classified into various colors to efficiently determine the dangerous trees and dangerous areas.

The Optimum of Respiratory Phase Using the Motion Range of the Diaphragm: Focus on Respiratory Gated Radiotherapy of Lung Cancer (횡격막의 움직임을 이용한 최적화된 호흡 위상의 선택: 폐암의 호흡 동기 방사선치료 중심)

  • Kim, Myoungju;Im, Inchul;Lee, Jaeseung;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.157-163
    • /
    • 2013
  • This study was to analyze quantitatively movement of planning target volume (PTV) and change of PTV volume through movement of diaphragm according to breathing phase. The purpose of present study was to investigate optimized respiration phase for radiation therapy of lung cancer. Simulated breathing training was performed in order to minimize systematic errors which is caused non-specific or irregular breathing. We performed 4-dimensional computed tomography (4DCTi) in accordance with each respiratory phase in the normalized respiratory gated radiation therapy procedures, then not only defined PTVi in 0 ~ 90%, 30 ~ 70% and 40 ~ 60% in the reconstructed 4DCTi images but analyzed quantitatively movement and changes of volume in PTVi. As a results, average respiratory cycle was $3.4{\pm}0.5$ seconds by simulated breathing training. R2-value which is expressed as concordance between clinically induced expected value and actual measured value, was almost 1. There was a statistically significant. And also movement of PTVi according to each respiration phase 0 ~ 90%, 30 ~ 70% and 40 ~ 60% were $13.4{\pm}6.4mm$, $6.1{\pm}2.9mm$ and $4.0{\pm}2.1mm$ respectively. Change of volume in PTVi of respiration phase 30 ~ 70% was decreased by $32.6{\pm}8.7%$ and 40 ~ 60% was decreased by $41.6{\pm}6.2%$. In conclusion, PTVi movement and volume change was reduced, when we apply a short breathing phase (40 ~ 60%: 30% duty cycle) range. Furthermore, PTVi margin considered respiration was not only within 4mm but able to get uniformity of dose.

Outcomes of Diffuse-Type Pigmented Villonodular Synovitis (PVNS) after Open Total Synovectomy (미만형 색소 융모 결절성 활액막염의 관혈적 활막 전 절제술 후 경과)

  • Lee, Mo-Ses;Lee, Soo-Hyun;Suh, Jin-Suck;Yang, Woo-Ik;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.27-36
    • /
    • 2010
  • Purpose: Pigmented villonodular synovitis (PVNS) is a rare soft tissue tumor, which usually arises in larger joints, such as the knee. It has a high recurrence rate after surgical treatment. The purpose of this study is to evaluate and analyze the clinical results of diffuse-type pigmented villonodular synovitis cases that were treated with open total synovectomy. Materials and Methods: Between 1994 and 2006, 21 patients who had diffuse-type pigmented villonodular synovitis were selectively reviewed. Among the 21 cases studied, 14 patients presented at the knee, 5 at the ankle, and 2 at the shoulder and elbow. The mean follow up period was 5.5 years (range, 36-157 months). The average age of the patients was 34 years consist of 7 men and 14 women. Clinical outcomes were analyzed retrospectively, including range of motion and complications. Results: Open total synovectomy and adjuvant electrocautrization were done in all cases except one. During the regular follow-up period after the surgery, two patients showed symptoms of recurrence. After re-operation, only one case was pathologically confirmed as a recurrence. The patient who had partial synovectomy and the other patient who had second operation due to recur rence received additional radiation therapy. Clinical outcome scores were improved in every aspect (p<0.0001). 2 out of 14 Patients who had pigmented villonodular synovitis at the knee developed stiff knee after the surgery. Conclusion: After the open total synovectomy with electrocautrization, a low recurrence rate and satisfactory clinical outcome was achieved, observed in a minimum of 3 years of follow-up.

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.

Influence of taper on the screw-in effect of nickel-titanium rotary files in simulated resin root canal (모형 레진근관에서 니켈-티타늄 전동 파일의 경사도가 screw-in effect에 미치는 영향)

  • Sung, Hye-Jin;Ha, Jung-Hong;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.380-386
    • /
    • 2010
  • Objectives: The introduction of nickel-titanium alloy endodontic instruments has greatly simplified shaping the root canal systems. However, these new instruments have several unexpected disadvantages. One of these is tendency to screw into the canal. In this study, the influence of taper on the screw-in effect of the Ni-Ti rotary instrument were evaluated. Materials and Methods: A total of 20 simulated root canals with an S-shaped curvature in clear resin blocks were divided into two groups. ProFile .02, .04, .06 (Dentsply-Maillefer) and GT rotary files .08, .10, .12 (Dentsply) were used in Profile group, and K3 .04, .06, .08, .10, and .12 (SybronEndo, Glendora) were used in K3 group. Files were used with a single pecking motion at a constant speed of 300 rpm. A special device was made to measure the force of screw-in effect. A dynamometer of the device recorded the screwin force during simulated canal preparation and the recorded data was stored in computer with designed software. The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. p value of less than 0.05 was regarded significant. Results: The more tapered instruments generated more screw-in forces in Profile group (p < 0.05). In K3 group, 0.08, 0.10. and 0.12 tapered instruments showed more screw-in force than 0.04 tapered one, and 0.08 and 0.12 tapered instruments showed more screw-in force than 0.06 tapered one (p < 0.05). Conclusions: The more tapered instruments seems to produce more screw-in force. To avoid this screw-in force during instrumentation, more attention may be needed when using more tapered instruments.