• Title/Summary/Keyword: range measurement

Search Result 4,371, Processing Time 0.031 seconds

Evaluation of Physical Properties of Liposome Essences as Customized Cosmetic Bases and Evaluation of Satisfaction According to Skin Type (맞춤형화장품 베이스로서 리포좀 에센스의 물성 평가 및 피부타입에 따른 만족도 평가)

  • An, Hyung Guen;Hyeon, Tong-Il;Yoon, Kyung-Sup
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • Customized cosmetics are continuously mentioned as a trend in the cosmetics industry to respond to the recent rapid changes in the social environment and pursue individuality and diversity. Accordingly, four types of liposome essence corresponding to skin types were prepared by varying the ratio of liposome formulation and essence formulation as a customized cosmetic base that can be easily mixed and applied at the workplace. The volatilization residues of four types of liposome essence were measured and the nanoparticle size, polydispersity index, zeta potential and viscosity according to time for 90 d were measured, and Turbiscan was measured as a method for evaluating the stability of a colloidal dispersion system. In addition, a simple usability evaluation was performed for four types of liposome essence corresponding to the skin type. As a result, the amount of volatile residue in the four types of liposome essence was increased in dry products rather than oily ones, and the particle size showed a tendency to increase with time in the range of 165 to 175 nm, increasing up to 31.5%, and the polydispersity index was 0.23 to 0.26. There was little change with time, and the zeta potential was -74 to -72 mV, showing a slight decrease with time, but there was little change to the extent of a maximum decrease of 14.0%. Viscosity showed a decreasing trend with time in the range of 2,580 ~ 3,290 cps, showing a maximum decrease of 17.5%. In the turbiscan measurement, all of the turbiscan stability index, a measure of stability, were less than 1.0, indicating dispersion stability. In the overall simple usability satisfaction evaluation for skin types (6 points), products for oily skin (5.33 ± 0.75 points) > products for medium dry skin (5.13 ± 0.95 points) > products for dry skin (5.03 ± 0.96 points) > products for oily skin (4.80 ± 1.04 points) points) were evaluated in order. The four types of liposome essence corresponding to skin types with different ratios of liposome formulation and essence formulation were physically stable, and the possibility of application as a customized cosmetic base according to skin type was confirmed.

Estimation of Monthly Dissolved Inorganic Carbon Inventory in the Southeastern Yellow Sea (황해 남동부 해역의 월별 용존무기탄소 재고 추정)

  • KIM, SO-YUN;LEE, TONGSUP
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.27 no.4
    • /
    • pp.194-210
    • /
    • 2022
  • The monthly inventory of dissolved inorganic carbon (CT) and its fluxes were simulated using a box-model for the southeastern Yellow Sea, bordering the northern East China Sea. The monthly CT data was constructed by combining the observed data representing four seasons with the data adopted from the recent publications. A 2-box-model of the surface and deep layers was used, assuming that the annual CT inventory was at the steady state and its fluctuations due to the advection in the surface box were negligible. Results of the simulation point out that the monthly CT inventory variation between the surface and deep box was driven primarily by the mixing flux due to the variation of the mixed layer depth, on the scale of -40~35 mol C m-2 month-1. The air to sea CO2 flux was about 2 mol C m-2 yr-1 and was lower than 1/100 of the mixing flux. The biological pump flux estimated magnitude, in the range of 4-5 mol C m-2 yr-1, is about half the in situ measurement value reported. The CT inventory of the water column was maximum in April, when mixing by cooling ceases, and decreases slightly throughout the stratified period. Therefore, the total CT inventory is larger in the stratified period than that of the mixing period. In order to maintain a steady state, 18 mol C m-2 yr-1 (= 216 g C m-2 yr-1), the difference between the maximum and minimum monthly CT inventory, should be transported out to the East China Sea. Extrapolating this flux over the entire southern Yellow Sea boundary yields 4 × 109 g C yr-1. Conceptually this flux is equivalent to the proposed continental shelf pump. Since this flux must go through the vast shelf area of the East China Sea before it joins the open Pacific waters the actual contribution as a continental shelf pump would be significantly lower than reported value. Although errors accompanied the simple box model simulation imposed by the paucity of data and assumptions are considerably large, nevertheless it was possible to constrain the relative contribution among the major fluxes and their range that caused the CT inventory variations, and was able to suggest recommendations for the future studies.

The color stability and antibacterial of provisional polyethyl methacrylate (PEMA) resin with zirconia nanoparticles (지르코니아 나노입자 첨가된 PEMA (Polyethyl Methacrylate)레진 표면의 색안정성 및 항균평가)

  • Kim, Hee-Seon;Lee, Seon-Ki;Jang, Woohyung;Park, Chan;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.18-25
    • /
    • 2022
  • Purpose: This study aimed to evaluate the color stability and antibacterial properties of the surface of polyethyl methacrylate (PEMA) resin with zirconia nanoparticles added. Materials and Methods: The control group was pure PEMA resin, and the experiment group was PEMA resin 15 mm in diameter and 2.5 mm in thickness disk-shaped specimens with 2, 4 and 8 w/v% of zirconia nanoparticles added, which were respectively divided into Group Z2, Group Z4, and Group Z8. After analyzing the surface roughness and color stability of the specimens, their antibacterial properties were evaluated using Porphyromonas gingivalis (P. gingivalis). The Statistical analysis was performed using when normality was met in the Shapiro-Wilk test, one-way ANOVA was used to test parameters, and Tukey's test was used as a post hoc test. When normality was not met, the Kruskal-Wallis test, a non-parametric test was used (P < 0.05). Results: The surface roughness measurement found that there was no significant difference between the experimental and control groups. The color stability evaluation showed that the Z2, Z4, and Z8 groups were within the color range of natural teeth. The adhesion of P. gingivalis was evaluated to be significantly reduced in Group Z2 compared to the control group (P < 0.05). In the Z2 group, Z4 group, and Z8 group, dead cells bacteria than the control group were observed. Conclusion: In conclusion, PEMA resin with zirconia nanoparticles added was within the range of natural teeth in color and reduced the adhesion of P. gingivalis.

The Study on the investigation of oriental medical theraphy(oriental medical theraphy by symptoms and signs and Sasang constitutional medicine)and the each effect of oriental medicine, occidental medicine and both joint control (뇌졸중(腦卒中)에 대(大)한 한방치료법(韓方治療法) 연구(硏究)(증치의학(證治醫學)과 사상의학(四象醫學)) 및 한방(韓方), 양방(洋方), 양(洋)·한방(韓方) 협진치료(協診治療) 효과(效果)에 관(關)한 연구(硏究))

  • Kim, Jong-won;Kim, Young-kyun;Kim, Beob-young;Lee, In-seon;Lee, In-seon;Jang, Kyung-jeon;Gwon, Jeong-Nam;Lee, Won-oe;Song, Chang-won;Park, Dong-il
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.2
    • /
    • pp.351-429
    • /
    • 1998
  • The Purpose of Study 1. Inspection of clinical application on TCD to CVA 2. Objective Comparement and analysis about treatment effect of Western-Medicine, Korean Medicine, Cooperative consultation of Korean and Western medicice for CVA The Subject of Study We intended for the eighty six patient of CVA who had been treated in the Oriental Medical Hospital at Dong Eui Medical Center from 1997. 8. I to 1998. 7. 31 1. View of CT, MRI : the patient of Cb infarction 2. Attack Time : The patient who coming hospital falling ill within the early one week The method of study 1. Treat four group of Korean medicine, Constitution medicine, Western medicine, cooperative consultation of Korean medicine and Western medicine. 2. Application of TCD Check the result for three times, immediatly after the attack, two months later, four months later 3. Comparative analysis of each treatment effect by clinical symptoms and pathologic examination 4. The Judgement of the patient The Result From 8/1/1997 to 7/31/1998, We have the following result by clinical analysis intended for CVA 86 patients who had been treated in the Oriental Medical Hospital at Dong Eui Medical Center from 1997. 8. 1 to 1998. 7. 31 in 1. Analysis according to Age The first stage of thirties, forties, seventies is heavier than forties, fifties in improvement and Index of improvement of symptom 2. Analysis according to sex We have no special relation in an average of symptom and improvement, Index improvement 3. Analysis according to Family History We have the better result in first stage and improvement, index improvement when no family history. 4. Analysis according to Past History We have no special relation in past history like hypertension, DM, heart problem 5. Analysis devided two group, above group and under group on the basis of the average in first stage of all patient. We have the better result when the first stage is light, that the first score of barthel index and CNS is high. 6. Analysis of the effect of treatment about Korean medical treatment, Western medical treatment, cooperative treatment. In this study, the highest group of rate of treatment at four contrast groups (Korean medicine, Constitution medicine, Western medicine, cooperative treatment according to dyagnosis and range of treatment was the patient group of doing dyagnosis and method of treatment based on constitution medicine theory. This is that of doing demostation, A-Tx, po-herb-medication according to dyagnosis and treat method of constitution of Lee Je-ma In case of left, the case of dyagnosis any disease according to doctor view but, normal in TCDwas 22-beginning of attack, 20- two weeks later, 11 case-four weeks later in case of right, 15-beginning of attack, 12-two weeks later, 9 case four weeks later. So left vessel compares to right vessel is more interference, in fact more than a 1/2 of the patients of MCA disease can't do dyagnosis. In rate of imparement, the state of pacient improved but there isn't the improved case of result in TCD. 7. In TCD dyagnosis, between the case of inconsus the doctor view specially MCA in brain blood vessel is in large numbers and in total 86's patient, impossible case of dyagnosis according to interferiance of temporal is 21 case. 7. Result study about application of Kreaan medical treatment 1) The impossible patient of observation MCA blood vescular for interference temporal bone happened in large numbers. 2) There is the case having difference result to CT,MRI, MRA result. 3) Because individual difference is large, excluding to ananalogy of symptom. This is normal numerical value that has possibility of being checked as abnormal numerical value 4) there are a lot of cases that the speed of normal part is as similarly measured as that of abnormal part. It means that we cannot judge the disease by this measure 5) It is rare that this measure represent degree of improvement in patient's condition of disease. When we observe patient's condition become better, but we have no case that the result of TCD test better. 6) The result could be appear differently by the technique of the tester or by the experience of the tester 7) In the TCD test, abnormal symptoms is checked at 0 week, but at 2th week, normal symptoms is checked, again at 4th week abnormal is checked. According to the above result, CVA diagnosis is difficult only with TCD, as it appear in diagnosis error check which is suggested in the problem connected to project, for the aged persons who have the worst hardening of part of the cranium (1998. 5. 26 77 of 83 patients is 50s) there is a lot of cases that the measurement is impossible by TCD and the correction of measurement numerical value is decreased, as the age of cerebral infarction is high, TCD is inappropriate to diagnosis equipment through this study.

  • PDF

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF

Effects of an Aspirated Radiation Shield on Temperature Measurement in a Greenhouse (강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향)

  • Jeong, Young Kyun;Lee, Jong Goo;Yun, Sung Wook;Kim, Hyeon Tae;Ahn, Enu Ki;Seo, Jae Seok;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.78-85
    • /
    • 2019
  • This study was designed to examine the performance of an aspirated radiation shield(ARS), which was made at the investigator's lab and characterized by relatively easier making and lower costs based on survey data and reports on errors in its measurements of temperature and relative humidity. The findings were summarized as follows: the ARS and the Jinju weather station made measurements and recorded the range of maximum, average, and minimum temperature at $2.0{\sim}34.1^{\circ}C$, $-6.1{\sim}22.2^{\circ}C$, $-14.0{\sim}15.1^{\circ}C$ and $0.4{\sim}31.5^{\circ}C$, $-5.8{\sim}22.0^{\circ}C$, $-14.1{\sim}16.3^{\circ}C$, respectively. There were no big differences in temperature measurements between the two institutions except that the lowest and highest point of maximum temperature was higher on the campus by $1.6^{\circ}C$ and $2.6^{\circ}C$, respectively. The measurements of ARS were tested against those of a standard thermometer. The results show that the temperature measured by ARS was lower by $-2.0^{\circ}C$ or higher by $1.8^{\circ}C$ than the temperature measured by a standard thermometer. The analysis results of its correlations with a standard thermometer reveal that the coefficient of determination was 0.99. Temperature was compared between fans and no fans, and the results show that maximum, average, and minimum temperature was higher overall with no fans by $0.5{\sim}7.6^{\circ}C$, $0.3{\sim}4.6^{\circ}C$ and $0.5{\sim}3.9^{\circ}C$, respectively. The daily average relative humidity measurements were compared between ARS and the weather station of Jinju, and the results show that the measurements of ARS were a little bit higher than those of the Jinju weather station. The measurements on June 27, July 26 and 29, and August 20 were relatively higher by 5.7%, 5.2%, 9.1%, and 5.8%, respectively, but differences in the monthly average between the two institutions were trivial at 2.0~3.0%. Relative humidity was in the range of -3.98~+7.78% overall based on measurements with ARS and Assman's psychometer. The study analyzed correlations in relative humidity between the measurements of the Jinju weather station and those of Assman's psychometer and found high correlations between them with the coefficient of determination at 0.94 and 0.97, respectively.

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Normative blood pressure references for Korean children and adolescents (한국 소아 청소년 정상 혈압 참고치)

  • Lee, Chong Guk;Moon, Jin Soo;Choi, Joong-Myung;Nam, Chung Mo;Lee, Soon Young;Oh, Kyungwon;Kim, Young Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.1
    • /
    • pp.33-41
    • /
    • 2008
  • Purpose : It is now understood that blood pressure (BP) measurement in the routine pediatric examination is very important because of the relevance of childhood BP to pediatric health care and the development of adult essential hypertension. There hasn't been a reference table of BP for Korean children and adolescents up to now. This study was to make normative BP references and to provide criteria of hypertension for Korean children and adolescents. Methods : BP measurements were done on 57,433 Koean children and adolescents (male: 29,443, female: 27,990), aged 7 to 20 years, in 2005. Heights and weights were measured simultaneously. Oscillometric devices, Dinamap Procare 200 (GE Inc., Milwaukee, Wi, USA), were used for the measurements. BPs were measured 2 times and mean levels were gathered for the analysis. Outliers of 2,373 subjects with overweight per height, over +3SD, were excluded for the analysis. For the BP centiles adjusted by sex, age and height, fixed modified LMS method which was adopted from the mixed effect model of 2004 Task Force in NHLBI (USA) was used. Results : Normative BP tables for Korean children and adolescents adjusted for height percentiles (5th, 10th, 25th, 50th, 75th, 90th, 95th), gender (male, female) and age(7 to 18 years) were completed. Height centiles of Korean children and adolescents are available from Korean Center for Disease Control and Prevention homepage, http://www.cdc.go.kr/webcdc/. Criteria of hypertension (95th, 99th percentile) and normal range of BP (50th, 90th) adjusted for height percentiles, age and gender were made. Conclusion : This is the first study to make normative BP tables and define hypertension for the Korean children and adolescents. Reliability and accuracy of Dinamap Procare 200 oscillometer for BP measurements remains debatable.

Relationship between exhaled nitric oxide and pulmonary function test in children with asthma (소아 천식에서 호기산화질소와 폐기능 검사의 관계)

  • Ko, Han-Seok;Chung, Sung-Hoon;Choi, Yong-Sung;Choi, Sun-Hee;Rha, Yeong-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.2
    • /
    • pp.181-187
    • /
    • 2008
  • Purpose : Asthma is characterized by reversible airway obstruction and bronchial hyperresponsiveness result from airway inflammation. Fraction of nitric oxide in expired air (FeNO) has recently been investigated as a noninvasive measure of airway inflammation. FeNO has been reported to correlate with induced sputum eosinophilia and methacholine challenge test that it is represent severity of asthma. The purpose of this study was to analyze the relationship of FeNO with pulmonary function tests in patients with intermittent asthma. Methods : Eighty children included in this study were diagnosed as asthma from April through August, 2005 in Department of Pediatrics, College of Medicine, Kyunghee University. They aged from 4 to 15 years who were able to conduct spirometry and FeNO monitoring. They did not have upper respiratory tract infection and did not use an asthma controller which contain corticosteroids within 4 weeks. Pulmonary function test was done and FeNO was measured with online tidal breathing method using a chemiluminescence NO analyzer (CLD 88 sp, Eco Medics, Duernten, Switzerland). The correlations between pulmonary function test and FeNO were analyzed using Spearman correlation coefficient method. Results : The mean of FeNO of subject was 16.88 parts per billion (ppb). The mean of forced expiratory volume in 1 second ($FEV_1$) was $0.890{\pm}0.455L$ and forced vital capacity (FVC) was $1.071{\pm}0.630L$. The mean of predicted $FEV_1%$ ($FEV_1%pred$) was $98.39{\pm}34.27%$ and $FEV_1/FVC$ was $88.53{\pm}19.49$. FeNO was significantly correlate with $FEV_1$ (r=0.345, P<0.01) and FVC (r=0.244, P<0.05). FeNO did not correlate with $FEV_1%pred$ or $FEV_1/FVC$. Conclusion : The measurement of FeNO could be a useful marker in the management of childhood asthma and it is evolving to provide a complementary role alongside existing pulmonary function test. We propose that measuring technique and establishment of normal reference range are important area for future research.

Characteristics of Radon Variability in Soils at Busan Area (부산광역시 일대의 토양 내 라돈 농도 변화 특성)

  • Kim, Jin-Seop;Kim, Sun-Woong;Lee, Hyo-Min;Choi, Jeong-Yun;Moon, Ki-Hoon
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.277-294
    • /
    • 2012
  • The characteristics of temporal spacial radon variation in soil according to parent rock type and affecting factors were studied in Busan, Korea. The concentration of $^{222}Rn$ in soils and their parent elements ($^{226}Ra$,$^{228}Ra$, U and Th) in rocks and soils were measured at 24 sites in Busan area. The distribution and transportation behavior of these parent elements were analyzed and their correlations to radon concentration in soil were determined. Topographic effects were also evaluated. Two in-situ radon measurement (soil probe and buried tube) methods were applied to measure radon concentration in soil and their accuracies were evaluated. The spatial variation of radon in soil generally reflected U concentration in the parent rock. Average radon concentrations were higher in plutonic rocks than in volcanic rocks and were decreased in the order of felsic>intermediate>mafic rock. However, the radon concentrations were significantly varied in soils developed from same parent rocks due to the disequilibrium of U and $^{226}Ra$ between rock and soil. As results, the correlation of these element concentrations between rocks and soils was very low and radon concentrations in soils had highly co-related to the concentrations of these elements in soils. Th and $^{228}Ra$ show complex enrichment characteristics, differing significantly with U, in soils developed from same parent rock because the geochemical behavior of these elements during weathering and soil developing process was different with U. The radon concentrations in the same depth of soil in slope area were also different according to positions. The radon concentrations in soils developed from same parent rocks (19 sites at Pusan National University) varied 6.8~29.8Bq/L range because of small scale topographic variation. The opposite seasonal variation pattern of radon were observed according to soil properties. It was determined that buried tube method is more accurate method than soil probe method and was very advantageous application for the analysis for the characteristics of temporal spacial radon variation in soil.