• Title/Summary/Keyword: raman

Search Result 2,112, Processing Time 0.029 seconds

Generating Synthetic Raman Spectra of DMMP and 2-CEES by Mathematical Transforms and Deep Generative Models (수학적 변환과 심층 생성 모델을 활용한 DMMP와 2-CEES의 모의 라만 분광 생성)

  • Sungwon Park;Boseong Jeong;Hongjoong Kim
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.422-430
    • /
    • 2023
  • To build an automated system detecting toxic chemicals from Raman spectra, we have to obtain sufficient data of toxic chemicals. However, it usually costs high to gather Raman spectra of toxic chemicals in diverse situations. Tackling this problem, we develop methods to generate synthetic Raman spectra of DMMP and 2-CEES without actual experiments. First, we propose certain mathematical transforms to augment few original Raman spectra. Then, we train deep generative models to generate more realistic and diverse data. Analyzing synthetic Raman spectra of toxic chemicals generated by our methods through visualization, we qualitatively verify that the data are sufficiently similar to original data and diverse. For conclusion, we obtain a synthetic dataset of DMMP and 2-CEES with the proposed algorithm.

Raman-tensor analysis of phonon modes in (Pb, Bi)2Sr2CaCu2O8+δ

  • Ji Yoon Hwang;Sae Gyeol Jung;Dong Joon Song;Changyoung Kim;Seung Ryong Park
    • Progress in Superconductivity and Cryogenics
    • /
    • v.26 no.1
    • /
    • pp.10-13
    • /
    • 2024
  • We performed angle-resolved Raman spectroscopy experiments on lead-doped and undoped Bi2Sr2CaCu2O8+δ(Bi2212) samples using a 660 nm laser and analyzed the Raman tensor of the phonon modes. The phonon mode was clearly observed at the 60, 103, and 630 cm-1 Raman shifts. The 60, 630 cm-1 peaks were only clearly observed when the incident and scattered light polarizations were configured to be parallel. The polarization angle dependence of the amplitude of the 60, 630 cm-1 peak on the parallel configuration shows a twofold symmetry; therefore, both peaks originate from Ag phonons and the crystal structure of Bi2212 should be considered orthorhombic. On the other hand, the 103 cm-1 peak is clearly observed in both parallel and perpendicular configurations. Remarkably, the off-diagonal component of the Raman tensor of the 103 cm-1 peak showed an anti-symmetry that could not be realized within the known crystal structure of Bi2212. The implications of our findings are discussed.

Asymmetry of the 1.54${\mu}m$ forward and backward raman gain in methane (라만매질 $CH_4$의 전후방 1.54${\mu}m$ 유도라만 산란광의 비대칭적 발생)

  • 최영수;고해석;강응철
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.89-94
    • /
    • 1999
  • The 1.54 ${\mu}{\textrm}{m}$ forward and backward stimulated Raman scattering (SRS) have been studied in CH$_4$pumped by 1.06 ${\mu}{\textrm}{m}$ Nd:YAG laser. The forward and backward SRS output energy in a single pass were measured at dufferent CH$_4$pressures. Under steady state conditions, the pump input threshold energies and Raman gains in forward and backward directions were for Raman conversion at various CH$_4$pressures for a tight focusing geometry. The forward and backward slope efficiency for Raman conversion were 18% and 34% respectively. The pump input threshold energy of the backward SRS was lower than that of the forward. In backward SRS, the experimental input laser threshold and Raman gain values were in good agreement with the calculated values at different pressures of CH$_4$. The retio of the backward to the forward SRS gain was appoximately 1.4 times above 1200 psi. We obtained that the backward Raman gain coefficient was 0.32 cm/GW, and the forward Raman gain coefficient 0.23cm/GW at 1400 psi. Asymmetry of the forward and backward Raman gain is caused by the interaction between different pump intensities of each direction duting the amplification of the Stokers. The backward Raman gain is proportional to the average pump intensity. However, the forward SRS output grows by depleting the local pump intensity.

  • PDF

Application Study of Raman Micro-Spectroscopy for Analysis on Corrosion Compound of Iron Artifacts (철제유물 부식화합물 분석의 표준데이터 확보를 위한 라만 분광법 적용성 연구)

  • Park, Hyung Ho;Lee, Jae Sung;Yu, Jae Eun
    • 보존과학연구
    • /
    • s.32
    • /
    • pp.89-98
    • /
    • 2011
  • It is quite difficult to identify its corrosion compound because they have a wide variety of crystal structures and they are mixed with two component. This study was conducted with the standard iron corrosion compounds through the analysis by Raman Micro-Spectroscopy, which aims to obtain standard Raman Data. To assess the reliability of standard iron corrosion compounds, SEM-EDS analysis and XRD analysis were conducted. Through SEM-EDS analysis, the elements of corrosion compound matched with those of standards iron corrosion compounds except Goethite. XRD analysis showed that the structures of corrosion compounds were identical to those of standard iron corrosion compounds, however, it was identified that Iron sulfate ($FeSO_4{\cdot}6H_2O$) is the Rozenite ($FeSO_4{\cdot}4H_2O$). Through Raman Micro-Spectroscopy analysis, the new peak was detected from the wavenumbers of hydroxide and iron oxide. It is considered that it is due to changes in the wavelength of the laser. As the wavenumbers of iron chloride and iron sulfate have been identified, eight kinds of Raman Data were obtained. It can be considered to contribute to cultral heritage for iron objects that Raman Micro-Spectroscopy analysis which is relatively easy to compare material properties and structures can be highly applicable to the research on cultural heritage with the limited amount of samples.

  • PDF

Measurement of CO Q-branch Raman Spectrum by using High Resolution Inverse Raman Spectrometer (고분해능 Inverse 라만 분광기를 이용한 CO Q-branch 라만 분광 측정)

  • 한재원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.59-64
    • /
    • 1989
  • Raman vibrational Q0branch spectra of pure CO are measured by using the technique of quasicw inverse Raman spectroscopy utilizing a pulsed single-frequency laser source. This approach gives enhanced sensitivity compared to earlier work which employed CW lasers, allowing extension of that work to higher accuracy, higher J states, and higher pressure. Fitting laws with pertubation theory and modified energy gap(MEG) theory are described, and the line broadening and shifting coefficients of J=0 to 24 are determined with both fitting laws.

  • PDF

Compositional Analysis of Naphtha by FT-Raman Spectroscopy

  • 구민식;정호일
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.2
    • /
    • pp.159-162
    • /
    • 1999
  • Three different chemical compositions of total paraffin, total naphthene, total aromatic content in naphtha have been successfully analyzed using FT-Raman spectroscopy. Partial least squares (PLS) regression has been utilized to develop calibration models for each composition from Raman spectral bands. The PLS calibration results showed Blood correlation with those of gas chromatography (GC). Using PLS regression, the spectral information related to each composition has been successfully extracted from highly overlapped Raman spectra of naphtha.

Raman Spectroscopy of the Solid Solution Limit in $Li_{1-X}Al_{2X}Ta_{1-X}O_3$ System (Raman 분광법을 이용한 $Li_{1-X}Al_{2X}Ta_{1-X}O_3$ 고용한계 분석)

  • Kim, Chong-Don;Hong, Kug-Sun;Joo, Gi-Tae
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.115-120
    • /
    • 1992
  • The upper limit of solid solution of $Al_2O_3$ in $LiTaO_3$ was investigated using X-ray diffraction and Raman spectroscopy. By substituting cations in $LiTaO_3$ with $Al^{3+}$, the melting temperature was lowed and the ferroelectric properties can be improved. It is easier at lower temperature to fabricate the single crystal used for SAW filters and IR sensors. From the measured lattice constants and Raman band broadening, the solubility limit was X=0.25mol in $Li_{1-X}Al_{2X}Ta{1-X}O_3$, above which $Al_2O_3$ was obsered as a second phase. The Raman band of sintered $LiTaO_3$ was compared with that of the single crystal to see the effect of grain size on the band broadening.

  • PDF

Effect of Residual Stress on Raman Spectra in Tetrahedral Amorphous Carbon(ta-C) Film

  • Shin, Jin-Koog;Lee, Churl-Seung;Moon, Myoung-Woon;Oh, Kyu-Hwan;Lee, Kwang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.135-135
    • /
    • 1999
  • It is well known that Raman spectroscopy is powerful tool in analysis of sp3/sp3 bonding fraction in diamond-like carbon(DLC) films. Raman spectra of DLC film is composed of D-peak centered at 1350cm-1 and G-peak centered at 1530cm-1. The sp3/sp3 fraction is qualitatively acquired by deconvolution method. However, in case of DLC film, it is generally observed that G-peak position shifts toward low wavenumber as th sp3 fraction increases. However, opposite results were frequently observed in ta-C films. ta-C film has much higher residual compressive stress due to its high sp3 fraction compared to the DLC films deposited by CVD method. Effect of residual stress on G-peak position is most recommendable parameter in Raman analysis of ta-C, due to its smallest fitting error among many parameters acquired by peak deconvolution of symmetric spectra. In current study, the effect of residual stress on Raman spectra was quantitatively evaluated by free-hang method. ta-C films of different residual stress were deposited on Si-wafer by modifying DC-bias voltage during deposition. The variation of the G-peak position along the etching depth were observed in the free-hangs of 20~30${\mu}{\textrm}{m}$ etching depth. Mathematical result based on Airy stress function, was compared with experimental results. The more reliable analysis excluding stress-induced shift was possible by elimination of the Raman shift due to residual compressiove stress.

  • PDF

Germination Prediction of Cucumber (cucumis sativus) Seed using Raman Spectroscopy (라만분광을 이용한 오이 종자의 발아예측)

  • Mo, Changyeun;Kang, Sukwon;Lee, Kangjin;Kim, Giyoung;Cho, Byoung-Kwan;Lim, Jong-Guk;Lee, Ho-Sun;Park, Jongryul
    • Journal of Biosystems Engineering
    • /
    • v.37 no.6
    • /
    • pp.404-410
    • /
    • 2012
  • Purpose: The objective of this research was to select high quality cucumber (cucumis sativus) seed by classifying into viable or non-viable one using Raman spectroscopy. Method: Both transmission and back-scattering Raman spectra of viable and non-viable seeds in the range from $150cm^{-1}$ to $1890cm^{-1}$ were collected with a laser illumination. Results: The Raman spectra of cucumber seed showed Raman peaks with features of polyunsaturated fatty acids. The partial least squares-discriminant analysis (PLS-DA) to predict viable seeds was developed with measured transmission and backscattering spectra with Raman spectroscopy and germination test results. Various types of spectra pretreatment were investigated to develop the classification models. The results of developed PLS-DA models using the transmission spectra with mean normalization or range normalization, and back-scattering spectra with mean normalization treatment or baseline correction showed 100% discrimination accuracy. Conclusions: These results showed that Raman spectroscopy technologies can be used to select the high quality cucumber seeds.

Rapid bacterial identification using Raman spectroscopy (라만 분광법을 활용한 세균 검측 기술)

  • No, Jee Hyun;Lee, Tae Kwon
    • Korean Journal of Microbiology
    • /
    • v.53 no.2
    • /
    • pp.71-78
    • /
    • 2017
  • Raman microspectroscopy is a promising tool for microbial analysis at single cell level since it can rapidly measure the cell materials including lipids, nucleic acids, and proteins by measuring the inelastic scattering of a molecule irradiated by monochromatic lights. Using Raman spectra provides high specificity and sensitivity in classification of bacteria at the strain level. In addition, a Raman approach coupled with stabled isotope such as $^{13}C$ and $^2H$ is able to detect and quantify general metabolic activity at single cell level. After bacterial detection process by Raman microspectroscopy, interested unculturable cell sorting and single cell genomics can be accomplished by combination with optical tweezer and microfluidic devices. In this review, the characteristics and applications of Raman microspectroscopy were reviewed and summarized in order to provide a better understanding of microbial analysis using Raman spectroscopy.