• Title/Summary/Keyword: radon-222

Search Result 80, Processing Time 0.027 seconds

Characterizing Groundwater Discharge and Radon Concentration in Coastal Waters, Busan City (부산 해안지역의 물의 라돈 농도와 지하수 유출 특성)

  • Ok, Soon-Il;Hamm, Se-Yeong;Lee, Yong-Woo;Cha, Eun-Jee;Kim, Sang-Hyun;Kim, In-Soo;Khim, Boo-Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.5
    • /
    • pp.53-66
    • /
    • 2011
  • Groundwater which infiltrated in recharge areas discharges in the forms of evapotranspiration, baseflow to streams, groundwater abstraction and eventually flows into the sea. This study characterized radon-222 concentration and electrical conductivity (EC) in coastal groundwater discharge, well groundwater, Ilkwang Stream water, and seawater in the coastal area of Busan Metropolitan City and subsequently estimated groundwater discharge rate to the sea. The median value of Rn-222 concentration is highest in well groundwater (18.36 Bq/L), and then decreases in the order of coastal groundwater discharge (15.92 Bq/L), Ilkwang Stream water (1.408 Bq/L), and seawater (0.030 Bq/L). The relationship between Rn-222 concentration and EC values is relatively strong in well groundwater and then in seawater. However, the relationship is not visible between coastal groundwater discharge and Ilkwang Stream water. The groundwater discharge rate to the sea is estimated as $3,130m^3$/day by using radon mass budget model and $16,788m^3$/day by using Darcy's law.

Effective Dose Equivalent due to Inhalation of Indoor Radon-222 Daughters in Korea (한국인의 라돈-222 자핵종 호흡 실효선량당량 평가)

  • Chang, Si-Young;Ha, Chung-Woo;Lee, Byoung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.1-13
    • /
    • 1991
  • Effective dose equivalents resulting from inhalation of indoor radon-222 daughters at 12 residential areas in Korea were assessed by a simple mathematical lung dosimetry model based on the measurements of long-term averaged radon concentrations at 340 dwellings. The long-term averaged indoor radon-222 concentrations and corresponding eqilibrium equivalent radon $concentration(EEC_{Rn})$ measured by passive time-integrating CR-39 radon cups are in the range of $33.82{\sim}61.42Bq/m^3(median\;:\;48.90Bq/m^3)$ and of $13.53{\sim}24.57Bq/m^3(median\;:\;19.55Bq/m^3)$, respectively. The effective dose equvalent conversion factor for the exposure to unit $EEC_{Rn}$ derived in this study was estimated $1.07{\times}10^{-5}mSv/Bq\;h\;m^{-3}$ for a reference adult and agreed well with those recommended by the ICRP and UNSCEAR. The annual average dose equivalent to the lung $(H_{LUNG})$ from inhalation exposure to measured $EEC_{Rn}$ was estimated to be 20.90 mSv and resulting effective dose $equivalent(H_E)$ was to be 1.25 mSv, which is about 50% of the natural radiation exposure of 2.40 mSv/y to the public reported by the UNSCEAR.

  • PDF

Radon-222 Concentrations of Metropolitan Subway Stations and Soils in the Seoul (서울 지하철역(地下鐵驛) 승강장(昇降場) 및 토양내(土壤內) 유해(有害)라돈함량(含量) 연구(硏究))

  • Hong, Young-Kook;Kim, Sung-Oh;Kim, Tong-Kwon
    • Economic and Environmental Geology
    • /
    • v.31 no.3
    • /
    • pp.215-222
    • /
    • 1998
  • The radon (Rn-222) potential of metropolitan subway stations and soils in Seoul city were delineated using alpha-track filter and EDA-200 radon detectors, respectively. The uranium (U) and thorium (Th) contents were also determined using a Multi Channel Analyzer to identify the sources of radon gas. The average U concentrations in Seoul varies according to basement rock types. For example, there is $9.40{\pm}10.11ppm$ in the Precambrian metasedimentary rock (PM), $9.08{\pm}2.85ppm$ in the Jurassic Kwanaksan granite (JK) and $4.94{\pm}1.43ppm$ in the Jurassic Seoul granite (JS). Uranium contents in soil samples are $10.30{\pm}4.74ppm$ in JK, $10.10{\pm}7.43ppm$ in PM and $6.69{\pm}3.95ppm$ in JS and these closely reflect the content of uraniferous minerals. The levels of soil radon are $604{\pm}273pCi/L$ in JK, $502{\pm}275$ in JS and $262{\pm}211pCi/L$ in PM. The soil radon concentrations are shown to reflect soil permeability and porosity rather than their U contents. The mean indoor radon contents in subway stations are $1.50{\pm}0.62pCi/L$ on the 4th line, $1.41{\pm}0.95pCi/L$ on the 3rd line, $0.84{\pm}0.13pCi/L$ on the 1st line and $0.80{\pm}0.25pCi/L$ on the 2nd line. The subway stations located in the JK have the highest average radon concentration with $2.04{\pm}0.65pCi/L$, where levels of $1.57{\pm}0.81pCi/L$ occur in the JS and $0.80{\pm}0.23pCi/L$ in the PM. The highest radon levels of 4.1 pCi/L occur mainly in Keongbokkung station on the 3rd line and these exceed 4 pCi/L of the US EPA action level.

  • PDF

Study on the Measurement of Radon concentrations in soil samples using γ-spectrometer (γ-spectrometer를 이용한 토양시료의 라돈농도 측정법에 관한 연구)

  • Kang, Sunga;Lee, Sangsoo;Choi, Guirack;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.31-36
    • /
    • 2013
  • The radioactive gas radon ($^{222}Rn$), which is generated from the decay process of uranium ($^{238}U$) originating from the soil of more than 85 percent higher the porosity of the soil, the soil can radiate out the possibility that many isotopes. In order to protect the human body from radon, above all, the development of accurate measurement techniques to formulate appropriate measures should be followed. This study Gamma-ray spectrometry using a high purity germanium (HPGe) detector, if you want to measure radon unstable the nature radiation of the background problems can be reduced, radium and radon daughter nuclides after radioactive equilibrium leads to Radon concentration was measured, the soil samples from the Gamma-ray emitting nuclides, and the energy spectrum is analyzed.

Air Content and Fluidity Properties of Cement Matrix according to Anthracite Particle-size (안트라사이트 입도에 따른 시멘트 경화체의 공기량 및 유동성 특성)

  • Kyoung, In-Soo;Pyeon, Su-Jeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.92-93
    • /
    • 2017
  • Recently, there has been an increasing interest in natural radioactive gas radon(Rn-222), the problem of indoor air quality pollution to worldwide. It has been scientifically proven to be hazardous to various diseases such as lung cancer and skin cancer if the human body is exposed to long-term accumulation of atomic nuclei due to the destruction of radon and alpha lines. Based on the indoor air quality control policy, this study is a basic experiment in the manufacture of a selective elimination function to containing radon adsorption and reduction of radon concentration, which is used to absorb radioactive isotopes such as phosphorus and radon in indoor environment.

  • PDF

Study on 222Rn reduction rate in boiling groundwater (가열에 의한 지하수 중 222Rn 제거율 고찰)

  • Kim, MoonSu;Kim, Hyun-Koo;Park, Sun-Wha;Kim, Hyoung-Seop;Ju, Byoung-Kyu;Kim, Dong-Su;Cho, Sung-Jin;Yang, Jae-Ha;Kwon, Oh-Sang;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.353-360
    • /
    • 2015
  • Boiling is an efficient removal method to reduce radon in groundwater when ventilating indoor air. 13 groundwater samples with various radon concentrations were used to evaluate the reduction rate of radon with heating temperature and time. The groundwater samples were obtained by Bladder pump and on-situ measurements such as dissolved oxygen (DO) and hydrogen concentration (pH) and so on were carried out by a flow cell system isolated from the ambient atmosphere environment. All samples for measuring radon in groundwater were analyzed by liquid scintillation counter (LSC). The experiment result showed that increasing groundwater temperature enhanced radon removal rate but the initial radon concentration with high level lowered the removal rate. This means that radon reduction in groundwater by heating needs more heating energy and longer heating time with radon concentrations. Radon removal rate in groundwater, therefore, mainly depends on the initial radon concentration, heating temperature, and heating time.

A Preliminary Investigation of Radon Concentration for Some Agricultural Greenhouses in Jeju Island (제주지역 일부 농업 시설 내 라돈 농도 예비 조사)

  • Kang, Tae-Woo;Song, Myeong-Han;Kim, Tae-Hyoung;Chang, Byung-Uck;Kim, Young-Jae;Kim, Geun-Ho;Park, Jae-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • BACKGROUND: A preliminary investigation of the radon ($^{222}Rn$) concentration has been conducted, employing solid-state nuclear-track detectors (SSNTD) and a continuous radon monitor (CRM), for fourteen randomly selected agricultural greenhouses in Jeju Island, where the underground-air was used for air conditioning and $CO_2$ supplement. METHODS AND RESULTS: The SSNTD was used to measure the average radon concentration for three months and the CRM was used for an instantaneous measurement. In order to obtain the radon concentration of a greenhouse, the SSNTDs were placed at a number of evenly distributed points inside the greenhouse and the mean of the measured values was taken. In addition, in order to assess the radon concentration of the underground-air itself, measurement was also made at the borehole of the underground-air in each agricultural facility, employing both the SSNTD and CRM. It is found that the radon concentration of the greenhouses ranges higher than those not using the underground-air and the average of Korean dwellings. While the radon concentration of most agricultural facilities is still lower than the reference level (1,000 Bq/$m^3$) recommended by the International Radiation Protection Committee (ICRP), three facilities at one site show higher concentrations than the reference level. The three-month-averaged radon concentration and the instantaneous radon concentration of the underground-air itself ranges 1,228- 5,259 and 3,322-17,900 Bq/$m^3$, respectively, and regional variation is more significant. CONCLUSION: From this results, radon concentration of the underground-air is assumed that it is associated with the geological characteristics and the boring depth of the region located of their.

Environmental Characteristics of Naturally Occurring Radioactive Materials (238U, 222Rn) Concentration in Drinking Groundwaters of Metamorphic Rock Areas: Korea (국내 변성암 지역 음용지하수 중 자연방사성물질(238U, 222Rn)의 환경 특성 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Jeong, Do Hwan;Hong, Jung Ki;Kim, Dong Su;Noh, Hoe Jung;Yoon, Jeong Ki;Kim, Tae Seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.3
    • /
    • pp.82-92
    • /
    • 2013
  • This study has investigated naturally occurring radioactive materials (N.O.R.M; $^{238}U$, $^{222}Rn$) for 353 drinking groundwater wells in metamorphic rock areas in Korea. Uranium concentrations ranged from N.D (not detected) to 563.56 ${\mu}g/L$ (median value, 0.68 ${\mu}g/L$) and radon concentrations ranged from 108 to 11,612 pCi/L (median value, 1,400 pCi/L). Uranium and radon concentrations in the groundwater generally are similar to USA with similar geological setting. Uranium concentrations in 9 wells (2.6%) exceeded 30 ${\mu}g/L$, which is the maximum contaminant level (MCL) by the US environmental protection agency (EPA), radon concentrations in 46 wells (13%) exceeded 4,000 pCi/L, which is the Alternative MCL (AMCL) by the US.EPA. The log-log correlation coefficient between uranium and radon was 0.32. The correlation coefficient between uranium and pH was 0.12 and the correlation coefficient between radon and temperature was -0.01. The correlation coefficient between uranium and $HCO_3$ was 0.09 and the correlation coefficient between uranium and Ca was 0.11. The median value of uranium was high Chung-Buk (1.78 ${\mu}g/L$), Gyeong-Buk (1.37 ${\mu}g/L$), In-Cheon (1.06 ${\mu}g/L$) for each province. On the other hand, the median value of radon was high In-Cheon (2,962 pCi/L), Chung-Buk (2,339 pCi/L), Jeon-Buk (2,165 pCi/L) for each province. Jeon-Buk for log-log correlation coefficient is the highest (0.63) among provinces.

Modeling the Controllable Parameters of Radon Environment System with Dose Sensitivity Analysis (실내 라돈환경계의 선량감도분석에 의한 제어매개변수 모델링)

  • Zoo, Oon-Pyo;Chang, Yi-Young;Kim, Kern-Joong
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.41-54
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of indoor radon $(^{222}Rn)$ and its decay products (Rn-D) by applying the input~output linear system theory. Physical behaviors of $^{222}Rn\;&\;Rn-D$ were analyzed in terms of $(^{222}Rn)$ gas -generation, -migation and -infiltration to indoor environments, and the performance output-function, i. e. mean dose equivalent to Tracho-Bronchial (TB) lung region, was assessed to the following extented ranges of the controllable paramenters; a) the ventilation rate $constant({\lambda}_v)\;:\;0{\sim}50[h^{-l}].\;b)$ the attachment rate $constant({\lambda}_a)\;:\;0{\sim}500[h^{-l}].\;c)$ the unattached-deposition rate constant (${\lambda}^u_d)\;:\;0-50[h-l]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations; a) indoor $^{222}Rn\;&\;Rn-D$ Behaviour; Jacobi-Porstendoerfer-Bruno model.

  • PDF