• 제목/요약/키워드: radionuclide detection

검색결과 46건 처리시간 0.033초

방사성동위원소정맥촬영술(放射性同位元素靜脈撮影術)의 진단적(診斷的) 의의(意義) - X-선정맥조영술(線靜脈造影術)과의 비교(比較) 연구(硏究) - (Diagnostic Significance of Radionuclide Venography - A Comparison with X-ray Contrast Venography -)

  • 배상훈;박재형;한만청;조보연;고창순
    • 대한핵의학회지
    • /
    • 제15권2호
    • /
    • pp.19-25
    • /
    • 1981
  • Radionuclide venographies were performed in 138 limbs of 58 patients and X-ray contrast venographies were performed in 23 paitents of them. Positive radionuclide venography findings were area of decreased sponding to the region of thrombosis, abnormal collateral flows below the lesion. The success rate of radionulide venography was 89% and the overall concordance between radionuclide venography and X-ray contrast venography was 91%. Radionuclide venography is simple and easy to perform and less invasive than X-ray contrast venography. These results indicate that radionuclide venography is the most ideal screening test for the detection of venous thrombosis in patient with signs & symptoms of deep vein thrombosis.

  • PDF

방사성핵종 뇌조조영술의 조기 동적 영상으로 뇌척수액 누출을 증명한 자발성 두개 내 저압 1예 (A Case of Spontaneous Intracranial Hypotension: Detection of Cerebrospinal Fluid Leakage by Early Dynamic Radionuclide Cisternography)

  • 김재수;양대웅;박석건
    • 대한핵의학회지
    • /
    • 제33권2호
    • /
    • pp.184-188
    • /
    • 1999
  • Although cerebrospinal fluid leakage is suggested as one of the causes of spontaneous intracranial hypotension, only a few cases with direct evidence of cerebrospinal fluid leakage on radionuclide cisternography have been reported in the literature. Indirect evidences of cerebrospinal fluid leakage such as early visualization of the soft tissue and bladder or delayed migration of radiotracer have been observed in most patients with spontaneous intracranial hypotension. We report a case of spontaneous intracranial hypotension in which cerebrospinal fluid leakage was directly demonstrated by early dynamic imaging of spine on radionuclide cisternography. We suggest that early dynamic imaging of spine is an important adjunctive procedure in detecting cerebrospinal fluid leakage in patients with spontaneous intracranial hypotension.

  • PDF

개심술 전후 방사성 동위원소를 이용한 심기능 평가에 관한 연구 -수술전 shunt 의 진단 및 교정수술후의 성적평가에 대하여- (Evaluation of Cardiac Function Using Radioisotope before and after Open Heart Surgery -Detection of Preoperative Cardiac Shunt and Postoperative Remnant Shunt by Nuclear Angiocardiography-)

  • 서경필
    • Journal of Chest Surgery
    • /
    • 제15권2호
    • /
    • pp.194-203
    • /
    • 1982
  • In this investigation we undertook to evaluate the utility of radionuclide cardiac angiography in the detection of cardiac shunts before and after surgical correction. Time-activity curves of ventricles and lungs were evaluated after bolus intravenous injection of 99mTc-human serum albumin in 512 preoperative patients and 551 post-operative patients. Omitting 31 cases of technical failure due to poor bolus, we detected shunts in 459 cases of 481 preoperative evaluations, so the detectability was 95.4%. The cases which couldn`t be detected by this method had small amount of shunt. Also the degree of shunt detected by radioisotope methods were well correlated with oxymetry method. [r=0.89, p<0.01 ] In postoperative evaluations, 18 out of 411 patients with left to right shunt and 10 out of 140 right to left shunt were found to have remnant shunts with radionuclide cardiac angiography. Of the 28 cases with failed operation, 2 were confirmed in reoperation, 2 by cardiac catheterization, 2 by two -dimensional echocardiography. All except one .f these patients had membranous ventricular septal defects and those with left to right shunts had moderate to severe pulmonary hypertension and shunt amount. Also those had larger septal defects than control group. We consider that radionuclide cardiac angiography is a simple and noninvasive method which can show the preoperative diagnosis and postoperative follow up of cardiac shunts.

  • PDF

이중구조 무기형광 함침막 제조 및 방사성핵종 탐지능력의 분석 (Preparation and Radionuclide Detection Analysis of Inorganic Fluor Impregnated Double-layered Membranes)

  • 이근우;서범경;박진호;남석태;한명진
    • 멤브레인
    • /
    • 제12권4호
    • /
    • pp.240-246
    • /
    • 2002
  • 방사선과의 상호작용에 의하여 섬광이 발생하는 무기형광체(inorganic fluor)인 cerium activated yttrium silicate(CAYS)를 폴리설폰 고분자막에 함침시킴으로써, 형광 용액의 도움 없이 방사능 오염도를 측정할 수 있는 새로운 측정막을 제조하였다. 막의 제조는 두 가지 공정으로 나누어진다. 우선 고분자와 용매의 균일한 1차 제막용액을 유리판 위에 제막 후 용매증발을 통해 폴리설폰 고분자막이 생성되도록 하였다. 고형화된 폴리설폰 필름 표면에 CAYS가 분산된 고분자 제막용액을 2차로 도포시킨 후, 비용매 욕조에 침지시키는 상전환 공정을 이용하거나 용매의 증발을 통한 유리화에 의해 2차 용액의 고형화를 유도함으로써 함침막을 제조하였다. 이렇게 제조된 막의 형상은 치밀한 구조를 지니는 고분자 지지체와 이에 완전히 고착된 CAYS함침막의 이중구조를 지니게되며, 지지체 부분은 막의 안정성을 2차 제막에서 생성된 부분은 기능성의 향상을 이룰 수 있는 구조적 특성을 지닌다. 제조된 함침막에 방사성핵종을 직접 도포하여 방사성핵종의 탐지 특성을 측정하였을 때 효율적인 탐지 특성을 지니는 것으로 확인되었다.

국소 간 종양의 조직적 특성을 평가하는데 있어 최근 핵의학의 역할 (Changing Role of Nuclear Medicine for the Evaluation of Focal Hepatic Tumors: From Lesion Detection to Tissue Characterization)

  • 김천기;윤미진
    • 대한핵의학회지
    • /
    • 제32권3호
    • /
    • pp.211-224
    • /
    • 1998
  • The role of scintigraphic imaging has moved from the detection of lesions to the tissue-specific characterization of lesions over the past 2 decades. Major advances in nuclear medicine imaging include: 1) positron imaging, 2) improved instrumentation, such as the use of multidetector (dual or triple head) gamma cameras for single photon emission computed tomography, and 3) development of numerous new radiopharmaceuticals for positron or single photon imaging (labeled glucose analogue, amino acids, fatty acids, hormones, drugs, receptor ligands, monoclonal antibodies, etc). These advances have resulted in a significantly improved efficacy of radionuclide techniques for the evaluation of various tumors, including those within the liver. The current role of nuclear medicine in the evaluation of focal hepatic tumors is reviewed in this article with an emphasis on the clinical applications of various tracer studies and imaging findings.

  • PDF

각종(各種) 심질환(心疾患)에서 방사성(放射性) 동위원소(同位元素) 심혈관촬영술(心血管撮影術)에 관한 연구(硏究) (A Study on the Radionuclide Cardiac Angiography in the Various Heart Diseases)

  • 정준기;박선양;유박영;조보연;김병국;고창순
    • 대한핵의학회지
    • /
    • 제13권1_2호
    • /
    • pp.7-14
    • /
    • 1979
  • Radionuclide cardiac angiography has distinct advantages in safety, patient comfort, cost and ease of performance. This method offers diagnostic accuracy equivalent to that of cardiac catheterization. By this method the qualitative and quantitative diagnosis of the cardiac shunts are available. Also for it is repeatable with ease and more physiologic, it has application in following pre- and post-operative shunt patients. We performed the radionuclide cardiac angiographies in 147 cases of heart diseases and 26 cases of normal group. 1. The detection of left-to-right shunt was possible in 22 of 24 patients, and 2 patients were not diagnosed due to small shunt amount. (Qp/Qs<1.3) In 21 patients of right-to-left shunt, all were diagnosed by radionuclide cardiac angiography. 2. With the pulmonary time-activity curve, $C_2/C_1$ ratio was calculated. In normal control group, a range of $C_2/C_1$ ratios of $21{\sim}38%$ was established with a mean value of $28.6{\pm}4.6%$. In patients with left-to-right shunts determined by catheterization data, the range of $C_2/C_1$ ratio was $33{\sim}90%$, with a mean value of $67.8{\pm}12.2%$. 3. In 8 cases of left-to-right shunt, $Q_p/Q_s$ ratios determined by radionuclide cardiac angiography were compaired with those of cardiac catheterization. The correlation coefficient was 0.907. (P<0.001) 4. Postoperative radionuclide cardiac angiographies were done in 21 cases. 3 of 13 patients with left-to-right shunts were found to have residual shunts. 8 patients with right-to-left shunts were confirmed to have no residual shunt.

  • PDF

Quantitative Comparison of Activity Calculation Methods for the Selection of Most Reliable Radionuclide Inventory Estimation

  • Hwang, Ki-Ha;Lee, Sang-Chul;Lee, Kun-Jai;Jeong, Chan-Woo;Ahn, Sang-Myeon;Kim, Tae-Wook;Kim, Kyoung-Doek;Herr, Y.H.
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.322-327
    • /
    • 2003
  • It is important to know the accurate radionuclide inventory of radioactive waste for the reliable management. However, estimation of radionuclide concentrations in drummed radioactive waste is difficult and unreliable because of difficulties of direct detection, high cost, and radiation exposure of sampling personnel. In order to overcome these difficulties, scaling factors (SFs) have been used to assess the activities of radionuclides that could not be directly analyzed. A radionuclide assay system has been operated at KORI site since 1996 and consolidated scaling factor method has played a dominant role in determination of radionuclides concentrations. However, some problems are still remained such as uncertainty of estimated scaling factor values, inaccuracy of analyzed sample values, and disparity between the actual and ideal correlation pairs and the others. Therefore, it needs to improve the accuracy of scaling factor values. The scope of this paper is focused on the improvement of accuracy and representativeness of calculated scaling factor values based on statistical techniques. For the selection of reliable activity determination method, the accuracy of estimated SF values for each activity determination method is compared. From the comparison of each activity determination methods, it is recommended that SF determination method should be changed from the arithmetic mean to the geometrical mean for more reliable estimation of radionuclide activity. Arithmetic mean method and geometric mean method are compared based on the data set in KORI system.

  • PDF

Spectral resolution evaluation by MCNP simulation for airborne alpha detection system with a collimator

  • Kim, Min Ji;Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1311-1317
    • /
    • 2021
  • In this study, an airborne alpha detection system, which consists of a passivated implanted planar silicon (PIPS) detector and an air filter, was developed. A collimator applied to the alpha detection system showed an enhancement in resolution and a degradation in detection efficiency. The resolution and detection efficiency were compared and analyzed to evaluate the performance of the collimator. Thus, the resolution was found to be more important than the efficiency as a determining factor of the detection system performance, from the viewpoint of radionuclide identification. The performance was evaluated on three properties of the collimator: hole shape, hole length, and the ratio between the hole and frame pitches. From the hole shape performance evaluation, a hexagonal collimator showed the highest resolution. Further, the collimator with a hole pitch of 14 mm was found to have the highest resolution while that with a frame pitch of 4-6 mm (i.e., 1.2-1.4 times longer than the hole pitch) showed the highest resolution.

Analysis of ultra-low radionuclide concentrations in water samples with baromembrane method

  • Vasyanovich, Maxim;Ekidin, Aleksey;Trapeznikov, Alexander;Plataev, Anatoly
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.253-257
    • /
    • 2021
  • This work demonstrates the use of baromembrane method based on reverse osmosis (RO) process. The method is realized on mobile complex, which allows to concentrate and determine ultra-low activity of radionuclides in water cooling ponds of Russian nuclear fuel cycle enterprises. The existence level of radionuclide background creates difficult conditions for identification the contribution of liquid discharges enterprise, as standard monitoring methods have a very high detection level for radionuclides. Traditional methods for determining the background radionuclides concentrations require the selection of at least 500 liters (l) of water, followed by their evaporation to form a dry residue. This procedure with RO membranes requires at least 5 days. It is possible to reduce the time and energy spent on evaporation of hundreds of water liters by pre-concentrating radionuclides in a smaller sample volume with baromembrane method. This approach allows preliminary concentration of water samples from 500 l volume till 20 l volume during several hours. This approach is universal for the concentration of dissolved salts of any heavy metals, other organic compounds and allows the preparation of water countable samples in much shorter time compared to the traditional evaporation method.

Radioactive iodine analysis in environmental samples around nuclear facilities and sewage treatment plants

  • Lee, UkJae;Kim, Min Ji;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1355-1363
    • /
    • 2018
  • Many radionuclides exist in normal environment and artificial radionuclides also can be detected. The radionuclides ($^{131}I$) are widely used for labeling compounds and radiation therapy. In Korea, the radionuclide ($^{131}I$) is produced at the Radioisotope Production Facility (RIPF) at the Korea Atomic Energy Research Institute in Daejeon. The residents around the RIPF assume that $^{131}I$ detected in environmental samples is produced from RIPF. To ensure the safety of the residents, the radioactive concentration of $^{131}I$ near the RIPF was investigated by monitoring environmental samples along the Gap River. The selected geographical places are near the nuclear installation, another possible location for $^{131}I$ detection, and downstream of the Gap River. The first selected places are the "front gate of KAERI", and the "Donghwa bridge". The second selected place is the sewage treatment plant. Therefore, the Wonchon bridge is selected for the upstream of the plant and the sewage treatment plant is selected for the downstream of the plant. The last selected places are the downstream where the two paths converged, which is Yongshin bridge (in front of the cogeneration plant). In these places, environmental samples, including sediment, fish, surface water, and aquatic plants, were collected. In this study, the radioactive iodine ($^{131}I$) detection along the Gap River will be investigated.