• Title/Summary/Keyword: radiological science

Search Result 3,938, Processing Time 0.026 seconds

Analysis of the Correlation Between Ultrasonography Diagnosis Fatty Liver Grade and Hyperlipidemia and Obesity Indicators by Age Groups (연령대별 초음파 진단 지방간 등급과 고지혈증 및 비만 지표 간의 상관관계 분석)

  • Hyeon, Sang-Yeon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.863-870
    • /
    • 2020
  • The purpose of this study was to analyze the correlation between the grade of fatty liver diagnosed by ultrasonography and hyperlipidemia and obesity indicators by age groups. A total of 1,470 patients of various sex and age groups were examined by abdominal ultrasonography at the H Center in Chungbuk. The patients were classified as normal and fatty liver by age groups (below twenty, the thirties, forty, fifties, and over sixties). The grade of fatty liver was classified in detail as Grade 1 (mild fatty liver), Grade 2 (moderate fatty liver), Grade 3 (severe fatty liver). We selected indicators of hyperlipidemia as total cholesterol, triglyceride, low-density lipoprotein cholesterol, and high-density lipoprotein cholesterol. The obesity indicators were height, weight, body mass index, and waist circumference. The demographical descriptive statistic analysis and frequency analysis by age groups were performed. The difference of average and correlation between hyperlipidemia and obesity indicators were analyzed. As a result, patients over 60 have fatty liver regardless of sex. there was a difference between triglyceride, high-density lipoprotein cholesterol, weight, body mass index, and waistline for all age groups. The degree of fatty liver was highly correlated with waist size and body mass index for all age groups.

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.

Analysis of the Correlation Between Kidney Function Indicators and Kidney Size According Age Groups in Ultrasonography (신장 초음파 검사에서 연령대에 따른 신장 기능 지표와 신장 크기 간의 상관관계 분석)

  • Go, Ryo-won;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.871-879
    • /
    • 2020
  • The purpose of this study was to analysis the correlation between kidneys function indicators and these size in ultrasonography. A total of 170 (male:86, female:84) patients of sex and age groups were examined by abdominal ultrasonography. The patients classified as those in their 20's, 30's, 40's, and over 50's. We measured the length, width, and cross-sectional height of the kidneys twice. At this time, the length of these were measured from the maximum upper to the maximum lower pole and the widest width in the same ultrasonography was measured to obtain the cross-sectional area. Other relevant indicators included body surface area, serum creatinine, glomerular filtration rate (GFR), MDRD (Modification of diet in renal disease) and C-G (Cockcroft-Gault). Significant comparisons of differences between relevant factors by age groups and sex were conducted with a one-way distribution analysis. Correlation analysis was also performed between relevant factors by using Pearson and Spearman correlation coefficient. It was defined as meaningful when the p-value was less than 0.05. As a result, the length, the width, and the cross-sectional area of kidneys were correlated with GFR, C-G, MDRD. Therefore, it is expected that the accuracy of diagnosis of kidneys disease will be increased if the relevant indicators are evaluated together rather than measuring only length of these in ultrasonography.

Research on ANIOS Disinfection Efficiency to Prevent Infection in Radiography Room (방사선촬영실 감염 방지를 위한 에니오설프의 소독효율 연구)

  • Jung, Woo-Chan;Ahn, Ki-Song;Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.55-61
    • /
    • 2021
  • In this study, microbes were collected before and after disinfection using ANIOS(ANIOSURF Premium NPC) and compared the areas where the radiological technologist and the patient frequently contacted the chest X-ray. From September 1st to September 7th, 2020. in P Hospital in Deagu, 4 region were collected in a 10×10 size using a sterile cotton swab of the transport medium, and before and after disinfection results were obtained through the colorimetric method. As a result, n the X-ray tube handle Proteus mirabilis, Staphylococcus epidermidis, Bacillus spp., Candida spp., and in the Chin region Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, NTM, and in the Chest region Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, and in the Palm region NTM, Candida spp. were detected, and 103 CFU(Colony Forming Unit) or more were measured. After disinfection, only X-ray tube handle was detect Bacillus spp. and more than 102 CFU was measured. Microorganisms found prior to disinfection can cause opportunistic infections, Experimental results showed that Aniosulf(0.25%) is more economical and disinfectant than ethanol(70-90%) and isopropyl alcohol(70-90%). However, further research is needed on the detection of Bacillus spp. resultingly this research is useful basic data of infection control in Radiography room and prevention secondary infections.

Ultrasonic Image Analysis Using GLCM in Diffuse Thyroid Disease (미만성 갑상샘 질환에서 GLCM을 이용한 초음파 영상 분석)

  • Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.473-479
    • /
    • 2021
  • The diagnostic criteria for diffuse thyroid disease are ambiguous and there are many errors due to the subjective diagnosis of experts. Also, studies on ultrasound imaging of thyroid nodules have been actively conducted, but studies on diffuse thyroid disease are insufficient. In this study, features were extracted by applying the GLCM algorithm to ultrasound images of normal and diffuse thyroid disease, and quantitative analysis was performed using the extracted feature values. Using the GLCM algorithm for thyroid ultrasound images of patients diagnosed at W hospital, 199 normal cases, 132 mild cases, and 99 moderate cases, a region of interest (50×50 pixel) was set for a total of 430 images, and Autocorrelation, Sum of squares, sum average, sum variance, cluster prominence, and energy were analyzed using six parameters. As a result, in autocorrelation, sum of squares, sum average, and sum variance four parameters, Normal, Mild, and Moderate were distinguished with a high recognition rate of over 90%. This study is valuable as a criterion for classifying the severity of diffuse thyroid disease in ultrasound images using the GLCM algorithm. By applying these parameters, it is expected that errors due to visual reading can be reduced in the diagnosis of thyroid disease and can be utilized as a secondary means of diagnosing diffuse thyroid disease.

A Study on Image Acquisition of Gamma Camera using Simulation LUT and MLPE (시뮬레이션 순람표와 최대우도함수를 이용한 감마카메라의 영상 획득 연구)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.409-414
    • /
    • 2021
  • In order to acquire an image from a gamma camera, linearity correction must be performed. To this end, digital coordinates are acquired by using a linearity map to accurately specify the location where the scintillator and gamma rays interact. In this study, a method for acquiring undistorted images and digital coordinates was developed using a lookup table and maximum likelihood position estimation without using a linearity map. The proposed method was verified by configuring a small gamma camera through DETECT2000 simulation. A gamma camera was constructed using a GAGG scintillator and a SiPM optical sensor, and a gamma-ray interaction was generated at the center of the scintillator, and a lookup table was prepared using the ratio of the signals obtained from the SiPM. Through the prepared lookup table and the maximum likelihood position estimation, the position of the signal obtained by the gamma-ray interaction was acquired as digital coordinates to compose an image. As a result, the linearity was maintained compared to the generally acquired image, the accuracy of the location where the gamma-ray interaction was generated was excellent, and the distance between the locations was uniform. Since the lookup table obtained through simulation is created using the ratio of the signal, it can be directly used in the experiment, and the position of the signal can be conveniently obtained with digital coordinates with corrected linearity without creating a linearity map.

A Study on the Maximization of Scintillation Pixel Array According to the Size of the Photosensor (광센서 크기에 따른 섬광 픽셀 배열의 최대화 연구)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.157-162
    • /
    • 2022
  • Since preclinical positron emission tomography imaging is performed on small animals that are very small compared to the human body, a detector with excellent spatial resolution is required. For this purpose, a system was constructed using a detector using small scintillation pixels. Since the size of the currently developed and used photosensors is limited, excellent spatial resolution can be obtained when the minimum scintillation pixel and maximum array are used. In this study, the size of the photosensor is fixed and various scintillation pixel arrays are configured to match the size of the scintillation pixels, so that no overlap occurs in the flood image and the maximum scintillation pixel array in which all scintillation pixels are distinguished. For this purpose, DETECT2000, which can simulate a detector module composed of a scintillator and an photosensor, was used. A photosensor consisting of a 4 × 4 array of 3 mm × 3 mm pixels was used, and the scintillation pixel array was configured from 8 × 8 to 13 × 13, and simulations were performed. A flood image was constructed using the data obtained from the photosensor pixel, and the maximum scintillation pixel array that does not overlap the image was found through the flood image and the profile. As a result, the size of the scintillation pixel array in which all scintillation pixels are imaged without overlapping each other in the flood image was 11 × 11.

Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion (척추경 나사못 삽입술 CT검사의 영상평가 분석)

  • Hwang, Hyung-Suk;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standard, Soft, Bone, Detail) was used using the image J program. Signal to noise ratio(SNR) and contrast to noise ratio(CNR) were compared and analyzed by obtaining measured values based on the given equation. And this study was to investigate tube voltage and algorithm suitable for CT scan for thoracic pedicle screw insertion. As a result, when non-MAR was used, the soft algorithm showed the highest SNR and CNR at 80, 100, 120, and 140 kVp, On the other hand, when MAR was used, the standard algorithm showed the highest at 80 kVp, and the standard and soft algorithms showed similar values at 100 kVp. At 120 kVp, the Soft and Standard algorithms showed similar values, and at 140 kVp, the Soft algorithm showed the highest SNR and CNR. Therefore, when comparing Non-MAR and MAR, even if MAR was used, SNR and CNR did not increase in all algorithms according to the change in tube voltage. In conclusion, it is judged that it is advantageous to use the Soft algorithm at 80, 100, 120, and 140 kVp in Non MAR, the Standard algorithm at 80 and 100 kVp in MAR, and the Soft algorithm at 120 and 140 kVp. This study is expected to serve as an opportunity to further improve the quality of images by using selective tube voltage and algorithms as basic data to help evaluate images of pedicle screw CT scans in the future.

Relationship between Carotid Intima Media Thickness and Appendicular Skeletal Muscle Index according to Gender (성별에 따른 경동맥 내중막두께와 사지근육량지수와의 관련성)

  • Yang, Sung-Hee;Lee, Hee-Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.309-317
    • /
    • 2022
  • It is reported that social distancing caused by the corona pandemic has resulted in a decrease in physical activity, and a decrease in muscle mass due to this increases the risk of vascular disease. Therefore, in this study, the risk of carotid intima media thickness was evaluated by measuring the thickness of CIMT, and the differences in variables according to gender were analyzed. From January 2022 to May 2022, a total of 220 people (121 males, 99 females) who performed blood tests, carotid ultrasound, and body composition analysis among those who visited the health check-up center of Busan H Hospital were included in this study. Significant differences in risk factors according to gender were analyzed using the chi-square test. The cut-off values of variables that can predict the risk of carotid intima media thickness were calculated, and the accuracy was evaluated by calculating the area under the curve, sensitivity, and specificity. As a result of the difference analysis, the higher the total cholesterol in men and the appendicular skeletal muscle index in women, the higher the risk of carotid intima media thickness. The cut-off value for predicting the risk of carotid intima media thickness was calculated to be greater than 199 mg/dL of total cholesterol in the male group and less than 5.9 kg/m2 of the appendicular skeletal muscle index in the female group. As a result of this study, the higher the total cholesterol in men and the lower the appendicular skeletal muscle index in women, the higher the risk of increased CIMT. Therefore, in women, the appendicular skeletal muscle index is expected to serve as an indicator to predict and prevent vascular changes at an early stage.

A Study on the Reduction of Absorbed Dose through the Insertion of a Shielding Material in the Intraoralsensor of Dental Radiography (치과 방사선촬영 시 구내 센서 내 차폐체 삽입을 통한 피폭선량 감소 연구)

  • Kim, A Yeon;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.273-279
    • /
    • 2022
  • In order to reduce the absorbed dose given to the patient during dental radiography, a sensor that inserts a shield into the intraoralsensor was designed. Using the designed sensor, the change in absorbed dose depending on whether or not a shield was used was evaluated. The system used to evaluate the absorbed dose is VEX-S300C from Vatech, and the energy spectrum of X-rays was obtained through SPEKTR simulation based on the irradiation conditions of 65 kV, 3 mA, and 0.15 sec, and the number of photons for each energy was derived. After designing the system through Genat4 Application for Tomographic Emission(GATE) simulation, the energy spectrum obtained was used as a radiation source to calculate the absorbed dose. Lead was used for the shield, and simulations were performed at 0.1 mm thickness intervals from 0.1 mm to 0.5 mm was evaluated. In the case of using an X-ray field with a diameter of 60 mm, the decrease in absorbed dose according to the presence or absence of a shield decreased exponentially as the thickness of the shield increased. In addition, when a 20 mm × 30 mm field was used, the absorbed dose was significantly reduced even when no shield was used, and it was confirmed that the absorbed dose was further reduced when a shield was used.