• 제목/요약/키워드: radiological emergency

검색결과 196건 처리시간 0.024초

X-band EPR dosimetry using minimum mass of tooth enamel for use in radiological accidents

  • Jae Seok Kim;Byeong Ryong Park;Han Sung Kim;In Mo Eo;Jaeryong Yoo;Won Il Jang;Minsu Cho;HyoJin Kim;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.123-131
    • /
    • 2024
  • Electron paramagnetic resonance (EPR) dosimetry for a tooth from an individual exposed is well known as retrospective dosimetry in radiological accidents. A major constraint of the conventional X-band tooth-EPR dosimetry is the necessity to extract the tooth of the exposed patient for dose assessment. In this study, to conduct the dose assessments of exposed patients through part-extraction of tooth enamel, the minimum detectable dose (MDD) of the tooth enamel was evaluated based on the amount of mass. Further, a field test was conducted via intercomparison using various dose assessment methods to verify the feasibility of X-band tooth-EPR dosimetry using the minimum mass of tooth enamel. The intercomparison results demonstrated that effective dose determination via X-band tooth-EPR dosimetry is reliable. Consequently, it was determined that the minimum mass of tooth enamel required to evaluate an absorbed dose above 0.5 Gy is 15 mg. Thus, EPR dosimetry using 15 mg of tooth enamel can be applied in the triage and initial medical response stages for patients exposed during radiological accidents. This approach represents an advancement in managing radiological accidents by offering a more efficient and less invasive method of dose assessment.

RADIATION DAMAGE IN THE HUMAN BODY ACUTE RADIATION SYNDROME AND MULTIPLE ORGAN FAILURE

  • AKASHI, MAKOTO;TAMURA, TAIJI;TOMINAGA, TAKAKO;ABE, KENICHI;HACHIYA, MISAO;NAKAYAMA, FUMIAKI
    • Nuclear Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.231-238
    • /
    • 2006
  • Whole-body exposure to high-dose radiation causes injury involving multiple organs that depends on their sensitivity to radiation. This acute radiation syndrome (ARS) is caused by a brief exposure of a major part of the body to radiation at a relatively high dose rate. ARS is characterized by an initial prodromal stage, a latent symptom-free period, a critical or manifestation phase that usually takes one of four forms (three forms): hematologic, gastrointestinal, or cardiovascular and neurological (neurovascular), depending upon the exposure dose, and a recovery phase or death. One of the most important factors in treating victims exposed to radiation is the estimation of the exposure dose. When high-dose exposure is considered, initial dose estimation must be performed in order to make strategy decisions for treatment as soon as possible. Dose estimation can be based on onset and severity of prodromal symptoms, decline in absolute lymphocyte count post exposure, and chromosomal analysis of peripheral blood lymphocytes. Moreover, dose assessment on the basis of calculation from reconstruction of the radiation event may be required. Experience of a criticality accident occurring in 1999 at Tokai-mura, Japan, showed that ARS led to multiple organ failure (MOF). This article will review ARS and discuss the possible mechanisms of MOF developing from ARS.

국내 방사능재난대응체계 실효성 제고를 위한 제언 (Suggestions to Improve the Effectiveness of National Radiological Emergency Response System)

  • 문주현
    • 방사성폐기물학회지
    • /
    • 제18권2호
    • /
    • pp.195-206
    • /
    • 2020
  • 국내 방사능재난대응체계는 일본 후쿠시마 원전 사고와 최근의 국내 대형 재난 교훈 등을 바탕으로 개선돼 오고 있지만, 아직 방사능재난 특성과 후쿠시마 원전 사고 교훈을 완전히 반영하고 있지 못하다. 하나의 방사능재난대응체계에 복수의 국내법이 적용되면서, 실제 상황 시, 대응체계의 실효성을 훼손할 가능성이 있는 법 조항 간 불일치 사항이 존재하기도 한다. 이에 본 논문에서는 방사능재난대응 속성을 분석하고, 방사능재난대응체계 적절성 측면에서 「재난 및 안전관리 기본법」과 「원자력시설 등의 방호 및 방사능 방재 대책법」에서 규정한 방사능재난대응체계, 후쿠시마 원전 사고 시 일본측의 방사능 재난 대응 활동을 분석하고, 이 분석결과를 토대로, 대응체계와 조직 측면에서 국내 방사능재난대응체계 실효성을 제고하기 위해 필요한 개선사항을 도출하여 제시하였다.

Reliability and Validity of a Nationwide Survey (the Korean Radiation Workers Study)

  • Lee, Dalnim;Lim, Wan Young;Park, Soojin;Jin, Young Woo;Lee, Won Jin;Park, Sunhoo;Seo, Songwon
    • Safety and Health at Work
    • /
    • 제12권4호
    • /
    • pp.445-451
    • /
    • 2021
  • Background: This study aimed to evaluate the reliability and validity of the self-administered questionnaire for Korean radiation workers. Methods: From May 24, 2016, to June 30, 2017, 20,608 participants completed the questionnaire, providing information on sociodemographics, lifestyle, work history and practices, medical radiation exposure, and medical history, which was linked to the National Dose Registry and the National Cancer Registry. The validity of the questionnaire was evaluated using the responses of 20,608 workers, and reliability was evaluated using the responses of 3043 workers who responded to the survey twice. Results: Responses concerning demographic characteristics and lifestyle showed reliability with a moderate-to-high agreement (kappa: 0.43-0.99), whereas responses concerning occupation and medical radiation exposure had a wide range of agreement (kappa: 0.05-0.95), possibly owing to temporal variability during employment. Regarding validity, responses to the question about the first year of employment had an excellent agreement with the national registry (intraclass correlation coefficient = 0.9); however, responses on cancer history had a wide range of agreement (kappa: 0.22-0.85). Conclusion: Although the reliability and validity of the questionnaire were not distinguished by demographic characteristics, they tended to be low among participants whose occupational radiation exposure was minimal. Overall, the information collected can be reliable for epidemiological studies; however, caution must be exercised when using information such as medical exposure and work practices, which are prone to temporal variability.

Radiation risk perception and its associated factors among residents living near nuclear power plants: A nationwide survey in Korea

  • Sung, Hyoju;Kim, Jung Un;Lee, Dalnim;Jin, Young Woo;Jo, Hyemi;Jun, Jae Kwan;Park, Sunhoo;Seo, Songwon
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1295-1300
    • /
    • 2022
  • There has been increased interest in researching risk perception of radiation to implement successful risk communication, particularly given the recent worldwide nuclear policy movement regarding nuclear energy. This study aimed to investigate characteristics of risk perception among residents living near normally operating nuclear power plants in South Korea by identifying factors associated with risk perception. A survey was conducted with face-to-face interviews for 1200 residents aged 20e84 years by gender- and age-stratified random sampling. Risk perception was associated with trust perception in nuclear safety, but was not highly correlated with benefit perception for utilizing nuclear power. Relatively high risk perception was observed in women, older age groups, and residents not having experience of nuclear-related education or work. This association remained after adjusting for other factors including benefit perception, trust perception, and psychological distress. In addition to these individual characteristics, risk perception was also associated with a residential district's own unique context, indicating that a strategy of risk communication should be developed differently for residents facing nuclear-related circumstances. Given that risk perception can be changed, depending on social values such as safety culture and economic setting, further studies are required to understand the changing characteristics of radiation risk perception.

Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity

  • Kim, Jae Seok;Park, Byeong Ryong;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Jang, Won Il;Cho, Gyu Seok;Kim, Hyun;Chang, Insu;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.479-485
    • /
    • 2022
  • At the Korea Institute of Radiological and Medical Sciences, physical human phantoms were developed to evaluate various radiation protection quantities, based on the mesh-type reference computational phantoms of the International Commission on Radiological Protection. The physical human phantoms were fabricated such that a radiophotoluminescent glass dosimeter (RPLGD) with a Tin filter, namely GD-352M, could be inserted into them. A Tin filter is used to eliminate the overestimated signals in low-energy photons below 100 keV. The measurement uncertainty of the RPLGD reader system based on GD-352M should be analyzed for obtaining reliable protection quantities before using it for practical applications. Generally, the measurement uncertainty of RPLGD systems without Tin filters is analyzed for quality assurance of radiotherapy units using a high-energy photon beam. However, in this study, the measurement uncertainty of GD-352M was analyzed for evaluating the protection quantities. The measurement uncertainty factors in the RPLGD include the reference irradiation, regression curve, reproducibility, uniformity, energy dependence, and angular dependence, as described by the International Organization for Standardization (ISO). These factors were calculated using the Guide to the Expression of Uncertainty in Measurement method, applying ISO/ASTM standards 51261(2013), 51707(2015), and SS-ISO 22127(2019). The measurement uncertainties of the RPLGD reader system with a coverage factor of k = 2 were calculated to be 9.26% from 0.005 to 1 Gy and 8.16% from 1 to 10 Gy. A blind test was conducted to validate the RPLGD reader system, which demonstrated that the readout doses included blind doses of 0.1, 1, 2, and 5 Gy. Overall, the En values were considered satisfactory.

Fingernail electron paramagnetic resonance dosimetry protocol for localized hand exposure accident

  • Jae Seok Kim;Byeong Ryong Park;Minsu Cho;Won Il Jang;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.270-277
    • /
    • 2023
  • Exposure to ionizing radiation induces free radicals in human nails. These free radicals generate a radiation-induced signal (RIS) in electron paramagnetic resonance (EPR) spectroscopy. Compared with the RIS of tooth enamel samples, that in human nails is more affected by moisture and heat, but has the advantages of being sensitive to radiation and easy to collect. The fingernail as a biological sample is applicable in retrospective dosimetry in cases of localized hand exposure accidents. In this study, the dosimetric characteristics of fingernails were analyzed in fingernail clippings collected from Korean donors. The dose response, fading of radiation-induced and mechanically induced signals, treatment method for evaluation of background signal, minimum detectable dose, and minimum detectable mass were investigated to propose a fingernail-EPR dosimetry protocol. In addition, to validate the practicality of the protocol, blind and field experiments were performed in the laboratory and a non-destructive testing facility. The relative biases in the dose assessment result of the blind and field experiments were 8.43% and 21.68% on average between the reference and reconstructed doses. The results of this study suggest that fingernail-EPR dosimetry can be a useful method for the application of retrospective dosimetry in cases of radiological accidents.

An Off-site Screening Process for the Public in Radiation Emergencies and Disasters

  • Yoon, Seokwon;HA, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.301-309
    • /
    • 2016
  • Background: A contamination screening process for the local population in radiation emergencies is discussed. Materials and Methods: We present an overview of the relevant Korean governmental regulations that underpin the development of an effective response system. Moreover, case studies of foreign countries responding to mass casualties are presented, and indicate that responses should be able to handle a large demand for contamination screening of the local public as well as screening of the immediate victims of the incident. Results and Discussion: We propose operating procedures for an off-site contamination screening post operated by the local government for members of the public who have not been directly harmed in the accident. In order to devise screening categories, sorting strategies assessing contamination and exposure are discussed, as well as a psychological response system. Conclusion: This study will lead to the effective operation of contamination screening clinics if an accident occurs. Furthermore, the role of contamination screening clinics in the overall context of the radiation emergency treatment system should be clearly established.

Radiation Induces Phosphorylation of STAT3 in a Dose- and Time-dependent Manner

  • Gao, Ling;Li, Feng-Sheng;Chen, Xiao-Hua;Liu, Qiao-Wei;Feng, Jiang-Bin;Liu, Qing-Jie;Su, Xu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권15호
    • /
    • pp.6161-6164
    • /
    • 2014
  • Background: We have reported the radiation could activate STAT3, which subsequently promotes the invasion of A549 cells. We here explored the dose- and time-response of STAT3 to radiation and the effect of radiation on upstream signaling molecules. Materials and Methods: A549 cells were irradiated with different doses of ${\gamma}$-rays. The expression of and nucleus translocation of p-STAT3 in A549 cells were detected by immunoblotting and immunofluorescence, respectively. The level of phosphorylated EGFR was also assessed by immunoblotting, and IL-6 expression was detected by real time PCR and ELISA. Results: Radiation promoted the phosphorylation of STAT3 at Y705 in a dose- and time-dependent manner and nuclear translocation. The level of phosphorylated EGFR in A549 cells increased after radiation. In additional, the mRNA and protein levels of IL-6 in A549 cells were also up regulated by radiation. Conclusions: STAT3 is activated by radiation in a dose-and time-dependent manner, probably due to radiation-induced activation of EGFR or secretion of IL-6 in A549 cells.