• 제목/요약/키워드: radiography projection method

검색결과 27건 처리시간 0.024초

Geometric calibration of a computed laminography system for high-magnification nondestructive test imaging

  • Chae, Seung-Hoon;Son, Kihong;Lee, Sooyeul
    • ETRI Journal
    • /
    • 제44권5호
    • /
    • pp.816-825
    • /
    • 2022
  • Nondestructive testing, which can monitor a product's interior without disassembly, is becoming increasingly essential for industrial inspection. Computed laminography (CL) is widely used in this application, as it can reconstruct a product, such as a printed circuit board, into a three-dimensional (3D) high-magnification image using X-rays. However, such high-magnification scanning environments can be affected by minute vibrations of the CL device, which can generate motion artifacts in the 3D reconstructed image. Since such vibrations are irregular, geometric corrections must be performed at every scan. In this paper, we propose a geometry calibration method that can correct the geometric information of CL scans based on the image without using geometry calibration phantoms. The proposed method compares the projection and digitally reconstructed radiography images to measure the geometric error. To validate the proposed method, we used both numerical phantom images at various magnifications and images obtained from real industrial CL equipment. The experiment results confirmed that sharpness and contrast-to-noise ratio (CNR) were improved.

Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements

  • Jung, Pil-Kyo;Lee, Gung-Chol;Moon, Cheol-Hyun
    • 대한치과교정학회지
    • /
    • 제45권6호
    • /
    • pp.282-288
    • /
    • 2015
  • Objective: This study investigated whether it is possible to use a two-dimensional (2D) standard in three-dimensional (3D) analysis, by comparing the angles and lengths measured from a midsagittal projection in 3D cone-beam computed tomography (CBCT) with those measured by 2D lateral cephalometric radiography (LCR). Methods: Fifty patients who underwent both LCR and CBCT were selected as subjects. CBCT was reoriented in 3 different methods and the measuring-points were projected onto the midsagittal plane. Twelve angle values and 8 length values were measured on both LCR and CBCT and compared. Results: Repeated measures analysis of the variance revealed statistically significant differences in 7 angular and 5 linear measurements among LCR and 3 types of CBCT (p < 0.05). Of these 12 measurements, multiple comparisons showed that 6 measurements (ANB, AB to FH, IMPA, FMA, Co-Gn, Go-Me) were not significantly different in pairwise comparisons. LCR was significantly different from 3 types of CBCT in 3 angular (SN to FH, interincisal angle, FMIA) and 2 linear (S-Go, Co-ANS) measurements. The CBCT method was similar for all measurements, except for 1 linear measurement, i.e., S-N. However, the disparity between the mean values for all parameters was within the range of clinical measurement error. Conclusions: 3D-CBCT analysis, using midsagittal projection, is a useful method in which the 2D-LCR normative values can be used. Although the measurements changed with reorientation, these changes were not clinically significant.

The influence of X ray beam angulation on the fractal analysis of trabecular architecture in human dry mandible using standardized tile counting method

  • Lee Kyung-Hee;Lee Sun-Bok;An Chang-Hyeon;Heo Min-Suk;Yi Won-Jin;Huh Kyung-Hoe;Park Moo-Soon;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제34권4호
    • /
    • pp.179-182
    • /
    • 2004
  • Purpose: The purpose of this study is to examine the effects of X-ray beam angulation on the fractal dimension of trabecular bone structure of human dry mandible using the tile counting method. Materials and Methods: We divided 5 human dry mandibles into an angle and a molar groups depending on the regions and deciding the region of interest (ROI). When contrasted with the ROI, the inferior cortex was appointed to be low and the lines perpendicular to the buccal cortex were appointed to be the standard angle. Direct digital intraoral radiographs were obtained from 9 different projection angles. We analyzed statistically the fractal dimension using the tile counting method. Results: There was a statistically significant difference in the fractal dimension of the regions and the mandibles, but there was no statistically significant difference in the fractal dimension according to the X-ray beam angulation. Conclusion : There is no statistically significant effect of the angle of the projection on the fractal dimension of trabecular bone structure of a human dry mandible according to the tile counting method.

  • PDF

CR영상에서 웨이블릿 패킷-푸리에 방법을 이용한 그리드 잡음 제거 (Grid Noise Removal in Computed Radiography Images Using the Combined Wavelet Packet-Fourier Method)

  • 이아영;김동윤
    • 전자공학회논문지
    • /
    • 제49권11호
    • /
    • pp.175-182
    • /
    • 2012
  • X선이 객체를 투과할 때 산란 방사선이 발생한다. 이를 방지하기 위하여 산란 방지 그리드를 사용하는데, 이때 투영 방사선 영상에 그리드 영상이 중첩되어 나타난다. 이러한 영상이 출력되면 영상에 무아레 무늬가 나타나 해부학적 정보를 가리게 된다. 그리드에 의한 잡음을 제거하기 위하여 현재까지 수행된 연구에서는 1차원 주파수 영역에서 그리드의 주파수를 계산하거나 2차원 웨이블릿 변환 및 푸리에 변환을 사용하여 잡음의 주파수를 제거하였다. 이러한 방법들은 그리드 잡음뿐만 아니라 영상에서의 진단 정보도 함께 제거하였다. 본 연구에서는 웨이블릿 패킷과 푸리에 변환 방법을 조합하여 CR 영상에서 그리드 잡음을 제거하는 방법을 제안하였다. 제안한 방법을 팬텀영상에 적용한 결과 신호 대 잡음 비율이 기존 방법에 비하여 5.2 - 7.4 dB 향상 되었으며, 실제 CR영상에 적용한 결과 그리드에 의한 주파수 대역을 효과적으로 제거하고 나머지 주파수 대역을 보호함으로써 영상 정보의 손실을 최소화한 결과를 얻을 수 있었다.

X-ray Micro-Imaging 기법 소개 및 불투명 튜브 내부의 마이크로 버블 가시화 연구 (X-ray Micro-Imaging Technique and Its Application to Micro-Bubbles in an Opaque Tube)

  • 이상준;김석;백부근
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.31-34
    • /
    • 2002
  • Imaging techniques using x-ray beam at high energies (>6KeV) such as contact radiography, projection microscopy, and tomography have been used to nondestructively discern internal structure of objects in material science, biology, and medicine. This paper introduces the x-ray micro-imaging method using 1B2 micro-probe line of PAL (Pohang Accelerator Laboratory). Cross-sectional information on low electron density materials can be obtained by probing a sample with coherent synchrotron x-ray beam in an in-line holography setup. Living organism such as plants, insects are practically transparent to high energy x-rays and create phase shift images of x-ray wave front. X-ray micro-images of micro-bubbles of $20\~120\;{\mu}m$ diameter in an opaque tube were recorded. Clear phase contrast images were obtained at Interfaces between bubbles and surrounding liquid due to different decrements of refractive index.

  • PDF

흉부 엑스선 촬영 시 촬영기법에 따른 영상 평가 (Image Evaluation of Projection Method in Chest Radiography)

  • 안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.217-223
    • /
    • 2022
  • 본 연구는 엑스선 흉부촬영에서 격자를 이용하여 촬영법과 Air Gap Technique을 이용한 촬영법에서 얻은 영상을 평가하기 위하여 대학병원 영상의학과에서 10년 이상 근무한 방사선사 선생님 5인에게 주관적 평가 ROC와 객관적 평가 SNR를 시행하였다. 분석한 결과는 Cronbach Alpha 값이 0.714로 유의하게 높았다. Air Gap Technique 촬영법에서 팬톰과 상수용체 간격을 20 cm 띄우고 관전압 100 kVp, 관전류와 촬영시간 8 mAs로 설정하고 촬영한 영상을 ROC 평가에서 18점, SNR 평가에서 6.149로 가장 높은 점수를 얻었다. 또한 격자를 이용하여 촬영법에서는 팬톰과 상수용체 간격을 15 cm 띄우고 관전압 110 kVp, 관전류와 촬영시간을 8 mAs에서 촬영 시 ROC 평가점수가 19점과 객관적평가인 신호대잡음비(SNR)가 6,622으로 가장 높은 점수를 받았다. 이에 격자를 이용하여 나타나는 격자의 cut-off 현상으로 인하여 재촬영뿐만 아니라 판독지연, 환자의 피폭선량 증가, 기계적 수명단축 등의 단점을 벗어나는 Air Gap Technique 촬영법을 활용한다면, 중환자실 및 응급환자를 위한 이동형 엑스선 촬영장비를 사용할 경우를 포함하여 흉부 촬영 시에 많은 도움이 되리라 사료된다.

방사선치료용 선형가속기를 이용한 Gated Cone-Beam CT의 유용성 연구 (Study on the Validation of the Gated Cone-Beam Computed Tomography on Radiation Therapeutic Linear Accelerator)

  • 서정민;김찬형;박병석;박철수;장현철;김정대
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6932-6939
    • /
    • 2015
  • 환자의 호흡은 방사선치료에서 중요한 인자로 작용한다. 종양을 치료하는 방사선 치료용 선형가속기에서 시행하는 기존의 cone-beam CT에서는 호흡에 의한 움직임이 반영되지 않아 영상에 왜곡이 발생하여 정확하지 못한 영상 정보를 획득하였다. 본 연구는 호흡에 의한 움직임을 고려하고 특정 순간을 포착한 gating을 적용하여 획득한 back projection 영상을 이용하여 cone-beam CT 영상으로 재구성하였으며 기존의 방법과 비교하였다. 기존의 방법은 영상 왜곡도가 400%에 달하였으나, 본 연구에서 시행한 gating을 적용한 cone-beam CT는 약 2%에 불과하였다. 이에 본 연구는 호흡의 움직임을 반영한 영상유도 방사선치료의 방향과 평가 방법을 제시하였다.

현장중심 교육과정을 적용한 방사선과 재학생의 직무수행도 평가 -일반촬영 (Evaluation of Job Performance of Radiology Students by using Field-based Radiography Course)

  • 권순무;김경아;박창희
    • 한국방사선학회논문지
    • /
    • 제10권7호
    • /
    • pp.551-557
    • /
    • 2016
  • 국가직무능력표준(National competency standards, NCS)은 산업현장에서 직무를 수행하기 위해 요구되는 지식, 기술, 태도 등의 내용을 국가가 체계화한 것이다. NCS기반 현장중심 교육과정을 적용한 방사선과 재학생 3학년을 대상으로 일반촬영에 대한 방사선사 직무수행도를 평가하였다. 평가 결과, 모든 촬영방식에서 우수 및 충족 비율이 93% 이상으로 현장중심 교육과정이 재학생의 직무수행도 향상에 긍정적인 영향을 끼친 것으로 판단된다. CR 방식은 전체적으로 가장 우수한 평가를 받았으나 대상자 간 편차가 크고 영상기기조작능력이 부족한 것으로 평가되었고 Film 방식은 노출조건 설정 및 현상작업이 문제점으로 평가되었다. DR 방식은 우수한 평가를 받았으나 영상기기조작능력, 부속기자재운영능력이 부족한 것으로 평가되었다. 각 촬영에서 성취수준 이하의 평가요소를 교과목 운영에 보완한다면 재학생의 학업성취도 향상뿐만 아니라 졸업 후 임상에서 방사선사 직무수행도 향상에 도움이 되리라 판단 한다.

상악동 거상술 시 Waters' Projection의 유용성에 대한 임상적 연구 (Clinical Availability of Waters' Projection in Sinus Elevation Procedures)

  • 서미현;김성민;하지영;이정근;명훈;이종호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권2호
    • /
    • pp.88-93
    • /
    • 2013
  • Purpose: Maxillary sinus elevation has been widely used to enable insertion of endosseous implants in severely resorbed maxilla. Maxillary sinusitis after this procedure was considered to be the major drawback, therefore, preoperative evaluation of paranasal sinus is considered to be important. In order to evaluate the condition of the sinus, we used Waters' projection. In this study, asymptomatic patients were evaluated by Waters' view, and compared to timing to assess the sinus cavity. Methods: The retrospective study was based on 14 patients who were performed sinus elevation surgery in Seoul National University Dental Hospital. These patients did not show any signs of maxillary sinusitis. These patients were taken Waters' view at preoperative, postoperative 1 day, 3 months, 6 months. In Waters' view, presence of air fluid level, radiopacity of sinus wall, or radiopacity of entire maxillary sinus were evaluated. The density, and sinus dimension changes were assessed using Adobe Photoshop CS5$^{(R)}$ (Adobe Systems Inc., San Jose, CA, USA). Results: Findings of Waters views in patients with clear maxillary sinus at preoperative time were followed by elevated sinus floor with transplanted bone, mucosal swelling, and air fluid level. At postoperative 3 months, and 6 months, the radiographic findings were similar to preoperative state. By contrast, patients with preoperative mucosal swelling, or haziness in sinus cavity showed radiopacity entire sinus in Waters' view. In cases of the patients who were treated with simultaneous treatment to mucosal swelling, good status of sinus cavity were found. Conclusion: Although Waters' projections provide the limited information, and is less sensitive method compared with computed tomography, it is simple, easy, and economical method to assess of maxillary sinus. We suggest using Waters' view as radiographic routine tool for evaluation of sinus condition, especially in the sinus elevation surgery.

프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구 (Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System)

  • 손준영;최성훈;이동훈;김희중
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.111-118
    • /
    • 2019
  • 흉부 디지털 단층영상합성장치는 기존 DR의 낮은 깊이 해상도, CT의 높은 피폭선량 문제를 해결할 수 있는 획기적인 영상장치로 대두되고 있다. 그러나 제한된 스캔 각도로 인해 프로젝션이 X 선 소스 동작 방향으로 흉부를 완전히 포함 할 수 없어 재구성 된 슬라이스의 위, 아래 방향 경계를 따라 강도의 불연속성이 발생하게 되는데 이러한 현상을 잘림 아티팩트 (Truncation artifact)라고 한다. 이 연구의 목적은 가중 정규화 접근법을 사용하여 잘림 아티팩트를 줄이고 리스템에서 개발한 프로토 타입 흉부 디지털 단층영상합성장치 시스템에 대한 이 접근법의 성능을 평가하는 것이다. 이 시스템의 source-to-image distance는 1100 mm 이고 X 선원의 회전 중심은 검출기 표면에서 100mm 위로 설정되었다. LUNGMAN 팬텀을 사용하여 ${\pm}20^{\circ}$의 투영 뷰를 $1^{\circ}$ 간격으로 41장을 얻은 후, filtered back projection 알고리즘으로 재구성했다. 정량적 평가를 위하여 시뮬레이션을 이용하여 기준영상을 재구성 후 peak signal to noise ratio와 structure similarity index 값을 평가하였으며 실제 실험 데이터를 이용하여 mean value of specific direction 값을 평가하였다. 시뮬레이션 결과로 아티팩트 보정 전 일반적인 filtered back projection 알고리즘으로 재구성 한 영상과 비교하여 peak signal to noise ratio값과 structure similarity index값 모두 각각 증가하였으며, 실제 실험 재구성 영상의 mean value of specific direction 결과는 아티팩트의 영향이 감소됨을 확인할 수 있었다. 결론적으로, 가중 정규화 방법은 잘림 아티팩트를 줄임으로써 진단의 어려움을 발생시키는 가능성을 개선시킬 수 있는 방법으로 사료된다.