• Title/Summary/Keyword: radiographic measurements

검색결과 130건 처리시간 0.022초

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

  • Ana, Faria-Inocencio;Mercedes, Gallas-Torreira
    • Imaging Science in Dentistry
    • /
    • 제41권3호
    • /
    • pp.115-121
    • /
    • 2011
  • Purpose : This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. Materials and Methods : A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. Results : This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. Conclusion : This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.

하악골 매식 부위 계측을 위한 나선형 단층촬영술의 신뢰도 (RELIABILITY OF SPIRAL TOMOGRAPHY FOR IMPLANT SITE MEASUREMENT OF THE MANDIBLE)

  • 김기덕;박창서
    • 치과방사선
    • /
    • 제27권2호
    • /
    • pp.27-47
    • /
    • 1997
  • The purpose of this study was to evaluate the accuracy and usefulness of spiral tomography through the comparison and analysis of SCANORA cross-sectional tomographs and DentaScan computed tomographic images of dry mandibles taken by a SCANORA spiral tomographic machine and a computed tomographic machine. Thirty-one dry mandibles with full or partial edentulous areas were used. To evaluate the possible effect of location in the edentulous area, it was divided into 4 regions of Me (region of mental foramen), MI (the midportion between Me and M2), M2 (the midportion between mental foramen and mandibular foramen) and S (the midportion of the mandibular symphysis). A ZPC column (sized 4 mm x 5 mm) was seated on the edentulous regions of Me, MI, M2 and S using the acrylic stent. Then SCANORA spiral tomography and computed tomography were taken on the edentulous regions which contained the ZPC column. The ZPC columns and cross-sectional images of the mandible were measured in the radiographs by three observers and the differences between the two imaging modalities were analysed. The results were as follows: 1. In comparing the actual measurements of the ZPC column and measurements in the radiographs, the mean error of the DentaScan computed tomography was 0.07 mm in vertical direction and -0.06 mm in horiwntal direction, while the mean error of the SCANORA spiral tomography was 0.06 mm in vertical direction and -0.12 mm in horizontal direction. There was a significant difference between the two radiographic techniques in the horizontal measurement of the ZPC column of the symphysis region (p<0.05). But there was no significant difference in the measurements of other regions (p>0.05). 2. In measurements of the distance from the alveolar crest to the inferior border of the mandible (H), and of the distance from the alveolar crest to the superior border of the mandibular canal (Y), there was no significant difference between the two radiographic techniques (p>0.05). 3. In measurements of the distance from the lingual border of the mandible to the buccal border of the mandible (W), and of the distance from the lingual border of the mandible to the lingual border of the mandibular canal (X), there was a significant difference between the two radiographic techniques in measurements of the midportion between the mental foramen and the mandibular foramen (M2) (p<0.05). But there were no significant differences in measurements of the other regions of symphysis (S), mental foramen (Me), the first one-fourth portion between the mental foramen and the mandibular foramen (M1) (p>0.05). 4. Considering the mean range of measurements between observers, the measurements of SCANORA spiral tomography showed higher value than those of DentaScan computed tomography, except in measurements of symphysis (S). 5. On the detectability of the mandibular canal, there was no significant difference between the two radiographic techniques (p>0.05). In conclusion, SCANORA spiral tomography demonstrated a higher interobserver variance than that of DentaScan computed tomography for implant site measurements in the posterior edentulous area of the mandible. These differences were mainly the result of difficulty in the detection of the border of the mandible in SCANORA spiral tomography. But considering the cost and the radiation exposure, SCANORA spiral tomography can be said to be a relatively good radiographic technique for implant site measurement.

  • PDF

Assessment of Radiographic Left Atrial Dimension in Maltese Dogs with ACVIM Stage B Myxomatous Mitral Valve Disease

  • Song-In Lee;Han-Joon Lee;Joong-Hyun Song;Kun-Ho Song
    • 한국임상수의학회지
    • /
    • 제39권6호
    • /
    • pp.287-293
    • /
    • 2022
  • Radiographic left atrial dimension (RLAD) is a useful measurement to assess left atrial enlargement in dogs. There are studies on the use of RLAD on various breeds of dogs, but no study on a specific breed with myxomatous mitral valve disease (MMVD). This study was conducted to compare RLAD measurements in Maltese dogs with MMVD ACVIM stage B1 and B2, and also to investigate the correlation of RLAD with the LA:Ao ratio. A total of 29 Maltese dogs were the subjects of this study. Each dog was diagnosed with MMVD ACVIM stage B1 or B2 based on physical examination, thoracic radiography, and echocardiography. The vertebral heart size (VHS), RLAD, LVIDDn, and LA:Ao ratio were measured and compared to evaluate the differences. There were significant differences in the RLAD, LVIDDn, and LA:Ao ratio between dogs with MMVD ACVIM stage B1 and those with stage B2. There was a significant correlation between the LA:Ao ratio and both the RLAD and VHS measurements, but the correlation coefficient was higher for RLAD. The RLAD scores exhibited a significant difference between dogs with ACVIM Stage B1 and with those with B2, and these scores had a higher correlation with the LA:Ao ratio measured by echocardiography than with VHS.

Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

  • De Molon, Rafael Scaf;Morais-Camillo, Juliana Aparecida Najarro Dearo;Sakakura, Celso Eduardo;Ferreira, Mauricio Goncalves;Loffredo, Leonor Castro Monteiro;Scaf, Gulnara
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.243-247
    • /
    • 2012
  • Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm ($IC_{95%}$:6.04-6.54) and 6.79 mm ($IC_{95%}$:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm($IC_{95%}$:6.40-6.89) and 6.79mm($IC_{95%}$:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

일반 측방 두부규격 방사선사진과 측방 추부규격 전산화 방사선사진에서의 계측점의 신뢰도에 대한 비교 연구 (A COMPARATIVE STUDY OF COMPUTED RADIOGRAPHIC CEPHALOMETRY AND CONVENTIONAL CEPHALOMETRY IN RELIABILITY OF HEAD FILM MEASUREMENTS (LANDMARKS IDENTIFICATION))

  • 김형돈;김기덕;박창성
    • 치과방사선
    • /
    • 제27권1호
    • /
    • pp.99-106
    • /
    • 1997
  • The purpose of this study was to compare & to find out the variability of head film measurements (and marks identification) between Fuji computed radiographic cephalometry and conventional cephalometry. 28 Korean adults were selected. Lateral cephalometric FCR film and conventional cephalometric film of each subject was taken. Four investigators identified 24 cephalometric landmarks on lateral cephalometric FCR film and conventional cephalometric film. The comparable measurements between lateral cephalometric FCR film and conventional cephalometric film were statistically analysed. The results were as follows : 1. In FCR film & conventional film, coefficient of variation (C.V.) of 24 landmarks was taken horizonta1ly & vertically. There is no significant difference of rank order of landmarks in C.V. between two films. 2. In comparison of significant differences of landmarks variability between FCR film & conventional film, horizontal value of coefficient of variation, showed significant differences in four landmarks among twenty-four landmarks, but vertical value of coefficient of variation showed significant differences in sixteen landmarks among twenty-four landmarks. FCR film showed significantly less variability than conventional film in 17 subjects among 20(4+16) subjects that showed significant difference.

  • PDF

하악관 위치 분석시 일반단층사진과 전산화단층사진의 비교연구 (COMPARATIVE STUDY OF THE MACROSCOPIC FINDING, CONVENTIONAL TOMOGRAPHIC IMAGING, AND COMPUTED TOMOGRAPHIC IMAGING IN LOCATING THE MANDIBULAR CANAL)

  • 최항문;유동수
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.535-544
    • /
    • 1995
  • The purpose of this study was comparision of conventional tomography with reformatted computed tomography for dental implant in locating the mandibular canal. Five dogs were used and after conventional tomographs and reformatted computed tomographs were taken, four dentist traced all films. Mandibles were sectioned with 2mm slice thickness and the sections were then radiographed(contact radiography). Each radiographic image was traced and linear measurements were made from mandibular canal to alveolar crest, buccal cortex, lingual cortex, and inferior border. Following results were acquired : 1. Reformatted computed tomographs were exacter than conventional tomography by alveolar crest to canal length of -0.6mm difference between real values and radiographs. 2. The average measurements of buccal cortex to mandibular canal width and lingual cortex to mandibular canal width of conventional tomographs were exacter than reformatted computed tomographs, but standard deviations were higher than reformatted computed tomographs. 3. Standard deviations of reformatted computed tomographs were lower than conventional tomographs at all comparing sites 4. At reformatted computed tomography 62.5% of the measurements performed were within. : filmm of the true value, and at conventional tomography 24.1% were. 5. Mandibular canal invisibiity was 0.8% at reformatted computed tomography and 9.2% at conventional tomography. Reformatted computed tomography has been shown to be more useful radiographic technique for assessment of the mandibular canal than conventional tomography.

  • PDF

치조골 높이 측정시 표준촬영과 교익촬영의 비교 (RELATIONSHIPS BETWEEN BITEWING AND PERIAPICAL RADIOGRAPHS IN ASSESSING CRESTAL ALVEOLAR BONE LEVELS)

  • 조용진;박태원
    • 치과방사선
    • /
    • 제15권1호
    • /
    • pp.75-83
    • /
    • 1985
  • Bitewing and periapical radiographic techniques are used in clinical and epidemiological studies to assess crestal alveolar bone levels. The purpose of the present study investigated relationships between these techniques by assessing alveolar crest location at the same site. Bitewing and periapical radiographs were available from posterior quadrants of 120 subjects. The distance from cemento-enamel junction to the alveolar crest (CEJ -CR) was measured for each proximal surface from the distal of the cuspid to the distal of the second molar. Data were arranged according to the proximal surface examined, and bitewing and periapical measurements were compared using paired tests. The obtained results were as follows; 1. In maxilla, a significant t ratio with a P value of 0.05 or less was reached for 78% and in mandible reached for 39%. 2. Pearson correlations were calculated 32 surfaces (89%) had values below 0.70 and so, data obtained by these techniques can not be used interchangeably on an individual or group basis. 3. In situations where the periapical measure was greater than the bitewing, it ranged up to 20.7% greater with a mean 9.8%. Where the bitewing was greater than periapical, it ranged up to 51. 9% greater, with a mean 18.2%. 4. The percentage difference was greater in maxillary posterior areas than in mandibular molar, premolar areas. A lower prevalence of significant differences was attributed to relatively more simple root and favorable radiographic conditions in mandibular molar and premolar areas. 5. The anatomical limitations imposed on periapical radiographic technique, most often result in somewhat foreshortened radiographic images. This situation would tend to be accentuated by the anatomical restrictions of the hard palate. 6. Consequently, since the significant differences frequently exist between measurements obtained from bitewing and periapical techniques, it is important to define which technique is used.

  • PDF

Dilantin에 의한 골연화증에 관한 치과방사선학적 연구 (DENTAL RADIOGRAPHIC STUDY ON THE DILANTIN INDUCED OSTEOMALACIA)

  • 김영걸;유동수
    • 치과방사선
    • /
    • 제13권1호
    • /
    • pp.87-96
    • /
    • 1983
  • Radiographic measurements on the width of mandibular cortical plate and the lamina dura and on the root length were done in 42 patients who were in long-term Dilantin medication. Osteoporosis and root abnormalities were also investigated. The obtained results were as follows: 1. The number of male patients was greater than that of female patients. 2. The width of mandibular cortical plate was thinner in patient group than in control group. 3. There was no significant change in the width of lamina dura between the patient group and control group. 4. The root length of patient group was generally shorter than that of control group. 5. There were evidences of generalized mandibular osteoporosis and alteration in mandibular canal wall in 8 patients. (19%) 6. In Dilantin induced osteomalacia, the radiographic changes of mandibular canal wall and mandibular cortical plate were prominent, but that of lamina dura was not significant.

  • PDF

Reliability and Validity of the Femorotibial Mechanical Axis Angle in Primary Total Knee Arthroplasty: Navigation versus Weight Bearing or Supine Whole Leg Radiographs

  • Kim, Seong Hwan;Park, Yong-Beom;Song, Min-Ku;Lim, Jung-Won;Lee, Han-Jun
    • Knee surgery & related research
    • /
    • 제30권4호
    • /
    • pp.326-333
    • /
    • 2018
  • Purpose: To evaluate the reliability and validity of the femorotibial mechanical axis angle from radiographs in the weight bearing (WB) and supine positions compared with navigation-measured values. Materials and Methods: Sixty-eight cases of navigation-assisted total knee arthroplasty (TKA) were included. The pre- and postoperative whole leg radiographs (WLRs) in WB and supine positions were compared with the initial and final navigation values. Results: The mean mechanical axis angle from the preoperative WBWLR and navigation were not statistically different (p=0.079) and were correlated strongly with each other (intraclass correlation [ICC], 0.818). However, on postoperative measurements, although the WBWLR and navigation values were not different (p=0.098), they were not correlated with each other (ICC, 0.093). The standard error of measurement was $1.8^{\circ}{\pm}3.6^{\circ}$ for the preoperative WBWLR and $2.5^{\circ}{\pm}4.8^{\circ}$ for the postoperative WBWLR. The validity that was determined by the Bland-Altman plot was not acceptable for both pre- and postoperative measurements. Conclusions: The preoperative WBWLR could provide accurate but not precise measurement value of the femorotibial mechanical axis angle for navigation-assisted TKA, and postoperative measurements in navigation were not comparable with radiographic measurements. The lack of agreement was found between the radiographic and navigation measurements of the coronal alignment regardless of pre- or postoperative evaluation although the accuracy was found acceptable. Level of Evidence : Level 4.

악관절 방사선 촬영법에 따른 과두위 분석에 관한 비교 연구 (A COMPARATIVE STUDY ON ASSESSMENT OF CONDYLAR POSITION BY THE TMJ RADIOGRAPHY)

  • 이진홍;박창서
    • 치과방사선
    • /
    • 제16권1호
    • /
    • pp.81-91
    • /
    • 1986
  • The author obtained the trans cranial radiographs of right and left side and the individualized lateral tomograms of right and left side after the analysis of submental vertex view from 8 young adults of 25-32 years with normal occlusion. The condylar position from 32 radiographs of normal TMJs were assessed with each measurement methods. All datas from these analyses were recorded and statistically processed with CYBER computer system. The results were obtained as follows. 1. In each measurement methods, the area measurements using the midpoint fossa and the midpoint condyle revealed the hightest concordance rate between the radiographic pairs. 2. In the subjective evaluation, the qualitative concordance existed in 44% and the full concordance existed in 25%, so it was found that concordance rates were relatively low between the radiographic pairs. 3. In each measurement methods, the area measurement using the midpoint fossa revealed the strongest correlation between the radiographic pairs. 4. The correlations between the area measurement using the midpoint fossa and subjective valuation revealed relatively strong value which is 0.926 in the trans cranial radiographic series and the lowest value which is 0.743 in the tomographic series.

  • PDF