• Title/Summary/Keyword: radiograph

Search Result 729, Processing Time 0.028 seconds

An atypical case involving real, ghost, and pseudo-ghost images on a panoramic radiograph

  • Jong-Won Kim;Yo-Seob Seo
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.57-62
    • /
    • 2024
  • Purpose: This report presents a unique case featuring real, ghost, and pseudo-ghost images on the panoramic radiograph of a patient wearing earrings. It also explains the formation of these images in an easy-to-understand manner. Materials and Methods: One real image and two ghost images appeared on each side of a panoramic radiograph of a patient wearing earrings on both sides. Of the two ghost images on each side, one was considered a typical ghost image and the other was considered a ghost-like real image (pseudo-ghost image). The formation zones of the real, double, and ghost images were examined based on the path and angles of the X-ray beam from the Planmeca ProMax. To simulate the pseudo-ghost and typical ghost images on panoramic radiography, a radiopaque marker was affixed to the right mandibular condyle of a dry mandible, and the position of the mandible was adjusted accordingly. Results: The center of rotation of the Planmeca ProMax extended beyond the jaw area, and the area of double image formation also reached beyond the jaw. The radiopaque-marked mandibular condyle, situated in the outwardly extending area of double image formation, exhibited triple images consisting of real, double (pseudo-ghost), and ghost images. These findings helped to explain the image formation associated with the patient's earrings observed in the panoramic radiograph. Conclusion: Dentists must understand the characteristics and principles of the panoramic equipment they use and apply this understanding to taking and interpreting panoramic radiographs.

A Study on the Diagnostic Detection Ability of the Artificial Proximal Caries by Digora$\textregistered$ (Digora$\textregistered$ 영상시스템을 이용한 인접면 인공 치아우식병소의 진단능에 관한 연구)

  • Oh Kyung-Ran;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.415-433
    • /
    • 1998
  • Digora system is an intraoral indirect digital radiography system utilizing storage phosphor image plate. It has wide dynamic range which allows it to decrease the patient s exposure time and may increase diagnostic ability through image processing (such as edge enhancement, grey scale conversion, brightness change, and contrast enhancement). And also, it can transmit and storage image information. The purpose of this study was to evaluate the diagnostic ability of artificial proximal caries between Conventional radiograph and Digora images(unenhanced image, brightness & contrast controlled image, and edge enhanced image). ROC(Receiver Operating Characteristic) analysis, paired t-tests, and F-tests were done for the statistical evaluation of detectability. The following results were acquired: 1. In Grade I lesions, the mean ROC areas of Conventional radiograph, Digora unenhanced image, Digora controlled image, and Digora edge enhanced image were 0.953, 0.933, 0.965, 0.978 (p>0.05). 2. In Grade II lesions, the mean ROC areas of Conventional radiograph, Digora unenhanced image, Digora controlled image, and Digora edge enhanced image were 0.969, 0.964, 0.988, 0.994. Among theses areas, there was just statistical significance between Diagnostic abilities of Digora edge enhanced image and Conventional radiograph (p<0.05). 3. In the Interobserver variability, the ROC curve areas of Digora edge enhanced image was lowermost in these areas, regardless of the Carious lesion depths. In conclusion, intraoral indirect digital system, Digora system, has the potential possibility as an alternative of Conventional radiograph in the diagnosis of proximal caries.

  • PDF

Correlation of Temporary Lateral Recumbency and Lung Opacity on Ventrodorsal Radiograph (일시적인 횡와 자세와 흉와위 영상에서 폐 불투과도의 상관관계)

  • Lee, Hyunjik;Jeong, Jiyoon;Choi, Wooshin;Lee, Donghoon;Lee, Youngjae;Chang, Jinhwa;Chang, Dongwoo
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.313-318
    • /
    • 2015
  • The lung opacity on radiography is influenced by various factors. The physical density of the lung and the attenuation ensured on computed tomography (CT) scans is determined by three components : lung tissue, blood, and air. Temporary right lateral recumbency may responsible for the increase of opacity on ventrodorsal projection view. Thus, our aim is to demonstrate that the effect of right lateral recumbency posture on right lung opacity using radiograph and CT scan. In this study, 62 dogs without clinical or radiologic signs of cardiopulmonary disease are selected. Thorax radiographs per 30 seconds for 2 minutes (30s, 60s, 90s, 120s) were performed for 62 dogs. After discussion of the radiographic findings of lung field by two radiologists and a student at Chungbuk national university veterinary medical center a consensus opinion was recorded. Computed tomography per a minute (1 min, 2 min) for 2 minutes were performed for 2 dogs. Mean x-ray attenuation of lung was measured quantitatively using software at two levels (aortic arch and basal level). Among 62 dogs with radiograph comparison, 9.3% of dogs showed influence by postural effect. However, all 2 dogs with computed tomography comparison, showed influence by postural effect. In conclusion, position dependent changes of lung density in CT exam are not consistent with thoracic radiograph.

Patient radiation dose and protection from cone-beam computed tomography

  • Li, Gang
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from $19{\mu}Sv$ to $1073{\mu}Sv$ and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.

CHROMIUM INTENSIFICATION OF A PROCESSED DENTAL RADIOGRAPH (현상처리된 치과용 방사선필름의 크롬 증강효과에 대하여)

  • Park Myoung-Seon;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.211-217
    • /
    • 1990
  • This study was undertaken to determine (1) the usefulness of chromium intensifier to improve the dignostic quality of light radiograph; (2) the effect of chromium intensifier on density, contrast; and (3) the effect of various chemical concentrations on density. The following results obtained: 1. CHROMIUM INTENSIFIER is useful for intensifying and improving the diagnostic quality of a light dental radiograph. 2. The degree of intensification can be controlled by varying bleaching time, repeating the processing, varying the proportions of the potassium bicarbonate and hydrochloric acid solutions. 3. The image produced is black and permanent. 4. The intensifier increases density and contrast.

  • PDF

Comparison of Vertical Magnification Ratio among Various Areas in Panoramic Radiographs

  • Song, Woong-Kyu;Seok, Hwa-Suk;Kim, Byeong-Rin;Choi, Seong-Ho
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.53-59
    • /
    • 2017
  • Purpose: The objective of the present article is to determine whether there are differences in vertical enlargement ratio among various sites within both jaws in a panoramic radiograph. Materials and Methods: Two hundred and seventy-threeimplant sites in panoramic radiographs were evaluated by two observers. Magnification ratios at various sites in both jaws were calculated and compared with each other. Result: The average vertical enlargement ratio in the panoramic radiograph was 1.264 and this value was larger than original ratio 1.250. Although vertical magnification ratio of maxillary molar area was higher than that of mandibular molar area, every group showed similar magnification ratio in clinical respect. Conclusion: Vertical magnification ratio of the maxillary molar area is statistically higher than that of the mandibular molar area in the panoramic radiograph, but it is clinically negligible.

The Simple Regression Model of Gonial Angles : Comparison between Panoramic Radiographs and Lateral Cephalograms (Gonial Angle의 단순 회귀 모델: 파노라마 영상과 측모두부 영상간의 비교)

  • Park, Sung-Hee;Kim, Young-Jae;Lee, Sang-Hoon;Kim, Chong-Chul;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.2
    • /
    • pp.129-137
    • /
    • 2017
  • The aim of this study was to enhancing the panoramic radiograph's clinical use for assessing mandibular measurements and formulating a function of those measurements from panoramic radiographs and lateral cephalograms in children. The panoramic radiographs and lateral cephalograms of 99 former orthodontic patients with skeletal class III malocclusion were selected. In each radiograph, gonial angles, ramus heights, and distance between lower incisors and symphysis were measured. The values of the studied parameters were compared by paired t-test, Pearson's correlation test and regression analysis. The mean value of the gonial angle in panoramic radiographs was $125.49^{\circ}$, and the value in lateral cephalograms was $127.50^{\circ}$. The Pearson's correlation coefficient (${\rho}$) between mean values of gonial angle in each radiograph was 0.945 (p < 0.001). The relationship between the gonial angle measurements obtained from each radiographs was represented as 'Gonial angle (Lateral cephalograms) = 0.920 ${\times}$ Average gonial angle (Panoramic radiographs) + 12.072' in the linear function. The coefficients of ramus heights, and distance between lower incisors and symphysis portrayed weaker correlations than gonial angles. A panoramic radiograph could be used to determine the gonial angle as accurately as a lateral cephalogram, and each gonial angle showed a strong positive relation. A panoramic radiograph is a useful tool for examining vertical growth pattern of patients, as well as a lateral cephalogram.

DETECTION OF PROXIMAL CARIES USING LASER FLUORESCENCE (레이저 형광법을 이용한 인접면 우식증 탐지효과)

  • Mo, Kyung-Hee;Yoon, Jung-Hoon;Kim, Su-Gwan;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.323-330
    • /
    • 2004
  • The purpose of this study was to evaluate the diagnostic validity of early proximal caries lesions using laser fluorescence and whether the detection could be enhanced using a fluorescent dye. Direct visual examination and bitewing radiograph were used for comparison. The subjects of this study were 30 children of $3{\sim}9$ years old. Laser fluorescence and dye-enhanced laser fluorescence(mixed wavelength of 488 and 514 nm) were used and viewed through glasses(excluding wavelength<520 nm). For dye-enhanced laser fluorescence a 0.075% sodium fluorescein dye was applied before examination. Proximal caries lesion of each subject was assessed using visual examination, bitewing radiograph, laser fluorescence, and dye-enhanced laser fluorescence. The results in the three detection methods were compared to the assessment of bitewing radiograph. The results from the present study can be summarized as follows: 1. There was highly correlation(r=0.725-0.911) between the bitewing radiograph and all three detection methods(p<0.05) 2. The reproducibility(kappa value) of the visual examination, laser fluorescence and dye-enhanced laser fluorescence comparing with bitewing radiograph of proximal caries was 0.451, 0.683, 0.772, respectively. There was highest correlation between dye-enhanced laser fluorescence and bitewing radiograph for detection of proximal caries. The results from this study indicated that the dye-enhanced laser fluorescence considered to be accurate and reliable method in detecting proximal caries.

  • PDF

Evaluation of Surface Radiation Dose Reduction and Radiograph Artifact Images in Computed Tomography on the Radiation Convergence Shield by Using Sea-Shells (전산화단층영상장비에서 패각을 이용한 방사선 융합차폐체의 표면 방사선량 감소율과 방사선 인공물 영상 평가)

  • Seoung, Youl-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.2
    • /
    • pp.113-120
    • /
    • 2017
  • The purpose of this present study was to evaluate the surface radiation dose reduction and radiograph artifact images in computed tomography (CT) for the manufactured radiation shields by using sea-shells. The radiation convergence shields were made from silicons, sea-shells, barium powders, producted circle types of diameter 50 mm, thickness 3.5 mm for 5 kinds (only silicon shield, only barium shield, mixed sea-shells with silicon shield, mixed barium with silicon shield, mixed sea-shells with barium and silicon shield). Radiation generation and acquisition were used 4-channel multi-detector CT. The results of this study showed that mixed sea-shells with silicon shields could reduce the surface dose of 5.3% without radiograph artifact images. In the future, we will expect the radiation convergence shield as environmentally friendly materials by using the recycling of sea-shells with the advantages of silicon which can make various shapes.

Clinical Results after Closed Reduction and Internal Fixation for Unstable Subtle Injuries of Lisfranc Joint (초기 진단에 어려움이 있는 불안정성 족근 중족 관절 미세 손상에 대한 도수 정복 및 내고정술 후 임상적 결과)

  • Yu, Sun-O;Park, Yong-Wook;Kim, Joo-Sung;Lee, Gi-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.71-75
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate retrospectively the clinical results of closed reduction and percutaneous screw fixation for unstable injuries on stress radiographs in subtle injuries of Lisfranc joint. Materials and Methods: From June 1997 to March 2003, 6 cases of unstable injuries on stress radiograph in subtle injuries of Lisfranc joint were treated by percutaneous cannulated screw fixation after closed reduction. All cases were injuried by indirect force (twisting injury). The average diastasis between the 1st and 2nd metatarsal base was 3 mm (2-4 mm) on initial nonweight bearing AP radiograph. The average follow-up period was 20 months. Clinical evaluation was assessed according to the American Orthopedic Foot and Ankle Society (AOFAS) midfoot score. Results: The AOFAS midfoot score was average 86 (80-90) points. The average diastasis between 1st and 2nd metatarsal base was 2 mm (1-3 mm) on weight bearing AP radiograph in final follow up. The final diastasis was increased slightly than diastasis in initial postoperative radiographs. But the clinical results were good. There was no correlation between the degree of diastasis and the clinical results. On weight bearing lateral radiograph, the average difference with normal foot in the distance between plantar aspect of 5th metatarsus and medial cuneiform was 2 mm (0-3 mm). One case had mild arthritic change on the radiographs. Conclusion: When the Lisfranc injuries, especially in the subtle injuries were suspicious, the stress views are helpful to assess stability of the Lisfranc injuries and planning of treatment. For unstable injuries on stress radiographs in subtle injuries of Lisfranc joint, closed reduction and percutaneous screw fixation is useful method to expect good clinical results.

  • PDF