• 제목/요약/키워드: radioactive source

검색결과 296건 처리시간 0.023초

Development of a simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector (HPGe 검출기를 사용한 감마분광분석계의 점검선원 개발)

  • Lee, Mo Sung
    • Journal of Radiation Protection and Research
    • /
    • 제38권2호
    • /
    • pp.119-123
    • /
    • 2013
  • A simple laboratory-made radioactive source to check the integrity of a gamma spectrometry system with HPGe detector was developed. The check source consists of radium-riched soil which was ground in size of less than 0.154mm and contained in air tight cylinderical vial, and provides photons with 12 distinct energies. The spectra of the check source were measured once a month during one year, analyzed the charactreictics of their peaks. When the gamma spectrometry system was in normal state, the areas and FWHMs of the gamma rays with more than 3% gamma emission rate in radium and its decay products was constant within standard deviation 2% and 3%, respectively, except 77 keV peak. And it was found that this check source can play a sufficient role to check the integrity of a gamma spectrometry system using 10 peaks in the range of 77 to 2202 keV.

Neutron Count Rate Measurement of $UO_2$ powder by Neutron Source

  • Kang Hee-Young;Koo Gil-Mo;Ha Jang-Ho;Kim Ho-Dong;Yang Myung-Seung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 한국방사성폐기물학회 2005년도 춘계 학술대회
    • /
    • pp.344-349
    • /
    • 2005
  • Neutron count rate measurements to assay fissile content of uranium powder have been carried out in a neutron counter. The induced fission neutrons by Cf-252 neutron source are counted as the variation of fissile material in fuel material. The measured counts are compared with equivalent results obtained from calculation. It shows that the measured neutron counts versus quantity of $UO_2$ powder enrichment agreed reasonably well with the calculated values.

  • PDF

Remote handling systems for the Selective Production of Exotic Species (SPES) facility

  • Giordano Lilli ;Lisa Centofante ;Mattia Manzolaro ;Alberto Monetti ;Roberto Oboe;Alberto Andrighetto
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.378-390
    • /
    • 2023
  • The SPES (Selective Production of Exotic Species) facility, currently under development at Legnaro National Laboratories of INFN, aims at the production of intense RIB (Radioactive Ion Beams) employing the Isotope Separation On-Line (ISOL) technique for interdisciplinary research. The radioactive isotopes of interest are produced by the interaction of a multi-foil uranium carbide target with a 40 MeV 200 μA proton beam generated by a cyclotron proton driver. The Target Ion Source (TIS) is the core of the SPES project, here the radioactive nuclei, mainly neutron-rich isotopes, are stopped, extracted, ionized, separated, accelerated and delivered to specific experimental areas. Due to efficiency reasons, the TIS unit needs to be replaced periodically during operation. In this highly radioactive environment, the employment of autonomous systems allows the manipulation, transport, and storage of the TIS unit without the need for human intervention. A dedicated remote handling infrastructure is therefore under development to fulfill the functional and safety requirement of the project. This contribution describes the layout of the SPES target area, where all the remote handling systems operate to grant the smooth operation of the facility avoiding personnel exposure to a high dose rate or contamination issues.

Study of Classification and Disposal Method for Disused Sealed Radioactive Source in Korea (국내 폐밀봉선원 분류체계 및 처분방식 연구)

  • Kim, Sukhoon;Kim, Juyoul;Lee, Seunghee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • 제14권3호
    • /
    • pp.253-266
    • /
    • 2016
  • In accordance with the classification system of radioactive waste in Korea, all the disused sealed radioactive sources (DSRSs) fall under the category of EW, VLLW or LILW, and should be managed in compliance with the restrictions for the disposal method. In this study, the management and disposal method are drawn in consideration of half-life of radionuclides contained in the source and A/D value (i.e. the activity A of the source dividing by the D value for the relevant radionuclide, which is used to provide an initial ranking of relative risk for sources) in addition to the domestic classification scheme and disposal method, based on the characteristic analysis and review results of the management practices in IAEA and foreign countries. For all the DSRSs that are being stored (as of March 2015) in the centralized temporary disposal facility for radioisotope wastes, applicability of the derivation result is confirmed through performing the characteristic analysis and case studies for assessing quantity and volume of DSRSs to be managed by each method. However, the methodology derived from this study is not applicable to the following sources; i) DSRSs without information on the radioactivity, ii) DSRSs that are not possible to calculate the specific activity and/or the source-specific A/D value. Accordingly, it is essential to identify the inherent characteristics for each of DSRSs prior to implementation of this management and disposal method.

Measurement and Estimation for the Clearance of Radioactive Waste with Patients of Thyroid Treatment (갑상선 진료환자 관련 방사성폐기물의 처분을 위한 방사능 측정 및 평가)

  • Kim, Chang-Bum;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • 제14권6호
    • /
    • pp.255-261
    • /
    • 2014
  • The generation amount of radioactive waste has been rapidly increased by increase of the usage of radioisotope source in medical field. Especially, the use of the radioactive source of I-131 with short half-life of 8.02 days used in treatment of thyroid has been increased, and all of the wastes concerned have been disposed by means of the self-disposal method. IAEA proposed criteria for clearance level of waste which depends on the individual (10 ${\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, various radioactive wastes in medical fields are collected and measured for establishing the disposal methods and procedures of radioactive wastes. In addition, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and analytical half-life is considered. With comparing the theoretical half-life and the effective half life(7.72 days) which was based on the decay equation of measured data, it is resulted in the theoretical half-life is longer than effective half-life. The storage period of radioactive waste for self-disposal may be curtailed. The result of this study will be proposed as ISO standard.

A Study of Radioactive Contamination in Hospital Toilet (병원 화장실의 방사성 오염에 관한 연구)

  • Kim, Ki-Jin;Kim, Gha-Jung
    • Journal of the Korea Safety Management & Science
    • /
    • 제17권4호
    • /
    • pp.241-246
    • /
    • 2015
  • Generally a patient who was injected radiopharmaceuticals for nuclear medicine examination is not an object of isolation. Therefore, when the patient uses toilet, we expect surface contamination of a toilet by radioisotope. The measured value is $25.69Bq/cm^2$(a restroom near admission and administration), $19.39Bq/cm^2$(a toilet near department of radiology). The study shows that 9 of 24 locations in controlled area exceed over surface contamination limit. From now on, we should find source of contamination through measurement radioactive nuclide to apply radiation safety management.

Implementation of a Coded Aperture Imaging System for Gamma Measurement and Experimental Feasibility Tests

  • Kim, Kwangdon;Lee, Hakjae;Jang, Jinwook;Chung, Yonghyun;Lee, Donghoon;Park, Chanwoo;Joung, Jinhun;Kim, Yongkwon;Lee, Kisung
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제6권1호
    • /
    • pp.66-70
    • /
    • 2017
  • Radioactive materials are used in medicine, non-destructive testing, and nuclear plants. Source localization is especially important during nuclear decommissioning and decontamination because the actual location of the radioactive source within nuclear waste is often unknown. The coded-aperture imaging technique started with space exploration and moved into X-ray and gamma ray imaging, which have imaging process characteristics similar to each other. In this study, we simulated $21{\times}21$ and $37{\times}37$ coded aperture collimators based on a modified uniformly redundant array (MURA) pattern to make a gamma imaging system that can localize a gamma-ray source. We designed a $21{\times}21$ coded aperture collimator that matches our gamma imaging detector and did feasibility experiments with the coded aperture imaging system. We evaluated the performance of each collimator, from 2 mm to 10 mm thicknesses (at 2 mm intervals) using root mean square error (RMSE) and sensitivity in a simulation. In experimental results, the full width half maximum (FWHM) of the point source was $5.09^{\circ}$ at the center and $4.82^{\circ}$ at the location of the source was $9^{\circ}$. We will continue to improve the decoding algorithm and optimize the collimator for high-energy gamma rays emitted from a nuclear power plant.

The Study for the Fast Detection of the Stereo Radiation Detector using the Image Processing (영상처리기반 스테레오 감마선 탐지장치의 고속탐지에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1103-1105
    • /
    • 2015
  • Leaked Radioactive source in nuclear power station, radiation related facilities and the aging nuclear power plant for the dismantling must need to detect and remove early to prevent major accidents. In this paper, we implemented a single sensor-based gamma-ray detectors stereo which can provide the distance to the radiation source, a direction and doserate information for fast and efficient decontamination work the radiation source. And we have carried out an algorithm development for high-speed detection of the detection equipment. Two detectors are required for stereo structure for obtaining the distance information of the radioactive source, but we designed the only sensor-based detection device for the weight reduction. We have extracted the region of interest and obtained the distance calculation result and distribution of radiation source in order to minimize a stereo image acquisition time. Detection time of the algorithm showed a shorter time of about 41%.

  • PDF

The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector (스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Seung-Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제52권4호
    • /
    • pp.197-203
    • /
    • 2015
  • Nuclear power plant has increased continuously for power production in all over the world and the interest about nuclear accident and the dismantling of aging nuclear power plant has been a growing. The leaked radioactive source that is generated by radiation accidents must detect and remove to minimized the damage as soon as possible. Gamma-ray detection system that have been developed until now cannot provide the precise position of radioactive sources because they detect and imaging the position of radiation sources in just two dimensions. In this paper, stereo gamma ray detection system has developed and the algorithm for calculation of the distance has implemented to be able to measure the distribution of the leakage gamma ray source for the system. Stereo camera calibration for distance detection was conducted with the correction pattern and LED light and we carried out performance test of the system for the LED light source and a gamma ray source. In both experiments the results of the performance test, it was confirmed to have a 5% error. The results of this paper is used as a material for the development of gamma-ray imaging device.