• Title/Summary/Keyword: radioactive source

Search Result 296, Processing Time 0.019 seconds

STUDY ON THE EFFECT OF THE SELF-ATTENUATION COEFFICIENT ON γ-RAY DETECTOR EFFICIENCY CALCULATED AT LOW AND HIGH ENERGY REGIONS

  • El-Khatib, Ahmed M.;Thabet, Abouzeid A.;Elzaher, Mohamed A.;Badawi, Mohamed S.;Salem, Bohaysa A.
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • The present work used the efficiency transfer method used to calculate the full energy peak efficiency (FEPE) curves of the (2"*2" & 3"*3") NaI (Tl) detectors based on the effective solid angle subtended between the source and the detector. The study covered the effect of the self attenuation coefficient of the source matrix (with a radius greater than the detector's radius) on the detector efficiency. $^{152}$ An Eu aqueous radioactive source covering the energy range from 121.78 keV up to 1408.01 keV was used. In this study an empirical formula was deduced to calculate the difference between the measured and the calculated efficiencies [without self attenuation] at low and high energy regions. A proper balance between the measured and calculated efficiencies [with self attenuation] was achieved with discrepancies less than 3%, while reaching 39% for calculating values [without self attenuation] due to working with large sources, or for low photon energies.

Quality Assurance for High Dose Rate Brachytherapy (고선량율 근접치료의 정도관리)

  • Bang, Dong-Wan;Cho, Chung-Hee;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.30-44
    • /
    • 1998
  • Accurate delivery of doses using a high dose rate(HDR) brachytherapy, remote afterloading system(RALS) depends on knowing the strength of the radioactive source at the time of treatment, the precision and consistency of the timer, and the ability of the unit to position the source at the proper dwell location along the applicator. Periodic Quality Assurance(QA) on HDR machines is a part of the standard protocol of any user. The safety of the patient & staff, positional accuracy, temporal accuracy, and dose delivery accuracy are periodically(weekly, quarterly, monthly) estimated using HDR source(Ir-192), treatment planning devices, measurement devices, and overall treatment devices with regard to treatment delivery. The overall measurement results are estimated successfully and assessed its clinical significance. As a result, our HDR brachytherapy units has been very accurate until now. The QA program protocol permits routine clinical use and provides a high confidence level in the accurate operation of HDR units. Therefore, regular QA of HDR brachytherapy is essential for successful treatment.

  • PDF

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.

Performing a multi-unit level-3 PSA with MACCS

  • Bixler, Nathan E.;Kim, Sung-yeop
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.386-392
    • /
    • 2021
  • MACCS (MELCOR Accident Consequence Code System), WinMACCS, and MelMACCS now facilitate a multi-unit consequence analysis. MACCS evaluates the consequences of an atmospheric release of radioactive gases and aerosols into the atmosphere and is most commonly used to perform probabilistic safety assessments (PSAs) and related consequence analyses for nuclear power plants (NPPs). WinMACCS is a user-friendly preprocessor for MACCS. MelMACCS extracts source-term information from a MELCOR plot file. The current development can combine an arbitrary number of source terms, representing simultaneous releases from a multi-unit facility, into a single consequence analysis. The development supports different release signatures, fission product inventories, and accident initiation times for each unit. The treatment is completely general except that the model is currently limited to collocated units. A major practical consideration for performing a multi-unit PSA is that a comprehensive treatment for more than two units may involve an intractable number of combinations of source terms. This paper proposes and evaluates an approach for reducing the number of calculations to be tractable, even for sites with eight or ten units. The approximation error introduced by the approach is acceptable and is considerably less than other errors and uncertainties inherent in a Level 3 PSA.

Development of Exposure Level Prediction Program in Radioactive Waste Work (방사성 폐기물 작업 중의 피폭서량 예측 프로그램 개발)

  • Park, Won-Man;Kim, Yoon-Hyuk;Whang, Joo-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.71-77
    • /
    • 2005
  • In spite of the importance of nuclear power as one of major electric energies in Korea, the nuclear safety has become the most serious social issue in the operation of the nuclear power plant. In this paper, a virtual work simulation program was developed to predict exposure dose during radiation work in radwaste storage. The work simulation program was developed. using $Java ^{TM}$applet and VRML-virtual reality modeling language. A numerical algorithm to find the optimal work path which minimize exposure dose during the given work, was developed and exposure dose on the optimal work path was compared with that on the shortest path. Comparing with the shortest path for the given work, the predicted optimal path consumed longer work time by II% but reduced total exposure dose by 46%. The simulation result showed that the exposure dose depended on not only work time, but also the distance between the worker and the radiation source. The developed simulation program could be a useful tool for the planning of radioactive waste work to increase the radiation safety of workers.

Improvement of the Exponential Experiment System for the Automatical and Accurate Measurement of the Exponential Decay constant (지수감쇠계수의 자동 및 정밀 측정을 위한 지수실험장치 개선)

  • 신희성;장지운;이윤희;황용화;김호동
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.292-303
    • /
    • 2004
  • The previous exponential experiment system has been improved for the automatical and accurate axial movement of the neutron source and detector with attaching the automatical control system which consists of a Programmable Logical Controller(PLC) and a stepping motor set. The automatic control program which controls MCA and PLC consistently has been also developed on the basis of GENIE 2000 Library. The exponential experiments have been carried out for Kori 1 unit spent fuel assemblies, Cl4, Jl4 and G23, and Kori 2 unit spent fuel assembly, J44, using the improved systematical measurement system. As the results, the average exponential decay constants for 4 assemblies are determined to be 0.1302, 0.1267, 0.1247, and 0.1210, respectively, with the application of Poisson regression.

  • PDF

A Study on the Radioactivity Analysis of Decommissioning Concrete Using Monte Carlo Simulation (Monte Carlo 모사기법을 이용한 해체 콘크리트의 방사능 분석법 연구)

  • 서범경;김계홍;정운수;이근우;오원진;박진호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.43-51
    • /
    • 2004
  • In order to decommission the shielding concrete of KRR(Korea Research Reactor) -1&2, it must be exactly determined activated level and range by neutron irradiation during operation. To determine the activated level and range, it must be sampled and analyzed the core sample. But, there are difficulties in sample preparation and determination of the measurement efficiency by self-absorption. In the study, the full energy efficiency of the HPGe detector was compared with the measured value using standard source and the calculated one using Monte Carlo simulation. Also. self-absorption effects due to the density and component change of the concrete were calculated using the Monte Carlo method. Its results will be used radioactivity analysis of the real concrete core sample in the future.

  • PDF

Development of Moving Alternating Magnetic Filter Using Permanent Magnet for Removal of Radioactive Corrosion Product from Nuclear Power Plant

  • M. C. Song;Kim, S. I.;Lee, K. J.
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.494-501
    • /
    • 2002
  • Radioactive Corrosion Products (CRUD) which are generated by the neutron activation of general corrosion products at the nuclear power plant are the major source of occupational radiation exposure. Most of the CRUD has a characteristic of showing strong ferrimagnetisms. Along with the new development and production of permanent magnet (rare earth magnet) which generates much stronger magnetic field than the conventional magnet, new type of magnetic filter that can separate CRUD efficiently and eventually reduce radiation exposure of personnel at nuclear power plant is suggested. This separator consists of inner and outer magnet assemblies, coolant channel and container surrounding the outer magnet assembly. The rotational motion of the inner and outer permanent magnet assemblies surrounding the coolant channel by driving motor system produces moving alternating magnetic fields in the coolant channel. The CRUD can be separated from the coolant by the moving alternating magnetic field. This study describes the results of preliminary experiment performed with the different flow rates of coolant and rotation velocities of magnet assemblies. This new magnetic filter shows better performance results of filtering the magnetite at coolant (water). How rates, rotating velocities of magnet assemblies and particle sizes turn out to be very important design parameters.

Study of a Betavoltaic Battery Using Electroplated Nickel-63 on Nickel Foil as a Power Source

  • Uhm, Young Rang;Choi, Byoung Gun;Kim, Jong Bum;Jeong, Dong-Hyuk;Son, Kwang Jae
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.773-777
    • /
    • 2016
  • A betavoltaic battery was prepared using radioactive $^{63}Ni$ attached to a three-dimensional single trenched P-N absorber. The optimum thickness of a $^{63}Ni$ layer was determined to be approximately $2{\mu}m$, considering the minimum self-shielding effect of beta particles. Electroplating of radioactive $^{63}Ni$ on a nickel (Ni) foil was carried out at a current density of $20mA/cm^2$. The difference of the short-circuit currents ($I_{sc}$) between the pre- and post-deposition of $^{63}Ni$ (16.65 MBq) on the P-N junction was 5.03 nA, as obtained from the I-V characteristics. An improved design with a sandwich structure was provided for enhancing performance.

The Effect of Saponin Fraction of Panax ginseng C.A.Meyer on the Biosynthesis of Androgens in Rat Testis (인삼 사포닌이 쥐의 정소에서의 Androgen 생합성에 미치는 영향)

  • 홍성렬;주충노
    • Journal of Ginseng Research
    • /
    • v.9 no.2
    • /
    • pp.213-220
    • /
    • 1985
  • It was attempted to observe the effects of ginseng saponin, one of the major components of the roots of Panax ginseng, on androgen biosynthesis from cholesterol in vitro as well as in vivo in rat testis. Ginseng saponin was administered by stomach tubing prior to intraperitoneal injection of cholesterol containing (4-14C)-cholesteroll into adult male rats and the liver, testis and blood serum were analyzed. The first high radioactivity of the liver and blood serum of test animal was observed at 6 hours after radioactive cholesterol injection, while that of control appeared at 12 hours after the injection. In the case of testis, the first high radioactivity of test group appeared between 4 and 6 hours after the radioactive cholesterol injection, while that of control appeared at 10-14 hours. Analysis of radioactivity distribution of cholesterol, androstenedione and testosterone in the testis of rats fed with/without ginseng saponin piror to (4-14C)-cholesterol injection showed that the saponin stmulated the synthesis of androgens from cholesterol. This was confirmed again by in vitro experiment using testis homogenate as an enzyme source. From the above experimental results, it was suggested that the ginseng saponin stimulates both cholesterol transport and the biosynthesis of androgens from cholesterol in rat testis.

  • PDF