• Title/Summary/Keyword: radioactive noise

Search Result 33, Processing Time 0.026 seconds

CHARACTERISTICS OF THE BOAO 2K CCD CAMERA (보현산천문대 2K CCD 카메라의 특성)

  • PARK BYEONG-GON;CHUN MOO-YOUNG;YUK IN-SOO;SEONG HYEON-CHEOL
    • Publications of The Korean Astronomical Society
    • /
    • v.16 no.1
    • /
    • pp.31-36
    • /
    • 2001
  • We present the characteristics of the 2K CCD camera at the Bohyunsan Optical Astronomy Observatory of the Korea Astronomy Observatory at the time of its development. The purpose of this paper is to support the observers who may need detailed information on the characteristics of the camera and to provide helpful information on the optimization' of a CCD camera for those who try to develop their own camera. The 2K CCD camera was optimized to have a gain of $1.8e^-/ADU$ and a read out noise of $7e^-$ from an experiment using radioactive $^{55}Fe$ X-ray source. The charge transfer efficiency was measured as 0.9999976 for serial and 0.9999942 for parallel direction, which means $0.5\%$ charge loss along the serial direction and $1.2\%$ along the parallel direction across the chip. The quantum efficiency of the camera was measured from an experiment using a homogeneous light source consisting of a halogen lamp and an integrating sphere with a monochromator. The resulting quantum efficiency of the camera peaked at the wavelength range 600-700 nm with the value of $\~0.89$.

  • PDF

Improved Perfusion Contrast and Reliability in MR Perfusion Images Using A Novel Arterial Spin Labeling

  • Jahng, Geon-Ho;Xioaping Zhu;Gerald Matson;Weiner, Michael-W;Norbert Schuff
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.341-344
    • /
    • 2002
  • Neurodegenerative disorders, like Alzheimer's disease, are often accompanied by reduced brain perfusion (cerebral blood flow). Using the intrinsic magnetic properties of water, arterial spin labeling magnetic resonance imaging (ASLMRI) can map brain perfusion without injection of radioactive tracers or contrast agents. However, accuracy in measuring perfusion with ASL-MRI can be limited because of contributions to the signal from stationary spins and because of signal modulations due to transient magnetic field effects. The goal was to optimize ASL-MRI for perfusion measurements in the aging human brain, including brains with Alzheimer's disease. A new ASL-MRI sequence was designed and evaluated on phantom and humans. Image texture analysis was performed to test quantitatively improvements. Compared to other ASL-MRI methods, the newly designed sequence provided improved signal to noise ratio improved signal uniformity across slices, and thus, increased measurement reliability. This new ASL-MRI sequence should therefore provide improved measurements of regional changes of brain perfusion in normal aging and neurodegenerative disorders.

  • PDF

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF

Development of hybrid shielding system for large-area Compton camera: A Monte Carlo study

  • Kim, Jae Hyeon;Lee, Junyoung;Kim, Young-su;Lee, Hyun Su;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2361-2369
    • /
    • 2020
  • Compton cameras using large scintillators have been developed for high imaging sensitivity. These scintillator-based Compton cameras, however, mainly due to relatively low energy resolution, suffer from undesired background-radiation signals, especially when radioactive materials' activity is very low or their location is far from the Compton camera. To alleviate this problem for a large-size Compton camera, in the present study, a hybrid-type shielding system was designed that combines an active shield with a veto detector and a passive shield that surrounds the active shield. Then, the performance of the hybrid shielding system was predicted, by Monte Carlo radiation transport simulation using Geant4, in terms of minimum detectable activity (MDA), signal-to-noise ratio (SNR), and image resolution. Our simulation results show that, for the most cases, the hybrid shielding system significantly improves the performance of the large-size Compton camera. For the cases investigated in the present study, the use of the shielding system decreased the MDA by about 1.4, 1.6, and 1.3 times, increased the SNR by 1.2-1.9, 1.1-1.7, and 1.3-2.1 times, and improved the image resolution (i.e., reduced the FWHM) by 7-8, 1-6, and 3-5% for 137Cs, 60Co, and 131I point source located at 1-5 m from the imaging system, respectively.

CONCEPTUAL DESIGN OF THE SODIUM-COOLED FAST REACTOR KALIMER-600

  • Hahn, Do-Hee;Kim, Yeong-Il;Lee, Chan-Bock;Kim, Seong-O;Lee, Jae-Han;Lee, Yong-Bum;Kim, Byung-Ho;Jeong, Hae-Yong
    • Nuclear Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.193-206
    • /
    • 2007
  • The Korea Atomic Energy Research Institute has developed an advanced fast reactor concept, KALIMER-600, which satisfies the Generation IV reactor design goals of sustainability, economics, safety, and proliferation resistance. The concept enables an efficient utilization of uranium resources and a reduction of the radioactive waste. The core design has been developed with a strong emphasis on proliferation resistance by adopting a single enrichment fuel without blanket assemblies. In addition, a passive residual heat removal system, shortened intermediate heat-transport system piping and seismic isolation have been realized in the reactor system design as enhancements to its safety and economics. The inherent safety characteristics of the KALIMER-600 design have been confirmed by a safety analysis of its bounding events. Research on important thermal-hydraulic phenomena and sensing technologies were performed to support the design study. The integrity of the reactor head against creep fatigue was confirmed using a CFD method, and a model for density-wave instability in a helical-coiled steam generator was developed. Gas entrainment on an agitating pool surface was investigated and an experimental correlation on a critical entrainment condition was obtained. An experimental study on sodium-water reactions was also performed to validate the developed SELPSTA code, which predicts the data accurately. An acoustic leak detection method utilizing a neural network and signal processing units were developed and applied successfully for the detection of a signal up to a noise level of -20 dB. Waveguide sensor visualization technology is being developed to inspect the reactor internals and fuel subassemblies. These research and developmental efforts contribute significantly to enhance the safety, economics, and efficiency of the KALIMER-600 design concept.

A Study on the Establishment of Entropy Source Model Using Quantum Characteristic-Based Chips (양자 특성 기반 칩을 활용한 엔트로피 소스 모델 수립 방법에 관한 연구)

  • Kim, Dae-Hyung;Kim, Jubin;Ji, Dong-Hwa
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.140-142
    • /
    • 2021
  • Mobile communication technology after 5th generation requires high speed, hyper-connection, and low latency communication. In order to meet technical requirements for secure hyper-connectivity, low-spec IoT devices that are considered the end of IoT services must also be able to provide the same level of security as high-spec servers. For the purpose of performing these security functions, it is required for cryptographic keys to have the necessary degree of stability in cryptographic algorithms. Cryptographic keys are usually generated from cryptographic random number generators. At this time, good noise sources are needed to generate random numbers, and hardware random number generators such as TRNG are used because it is difficult for the low-spec device environment to obtain sufficient noise sources. In this paper we used the chip which is based on quantum characteristics where the decay of radioactive isotopes is unpredictable, and we presented a variety of methods (TRNG) obtaining an entropy source in the form of binary-bit series. In addition, we conducted the NIST SP 800-90B test for the entropy of output values generated by each TRNG to compare the amount of entropy with each method.

  • PDF

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Efficiency Calibration of HPGe Detector in Normal ana Coincidence Mode for the Determination of Prompt Gamma-ray (즉발감마선 측정을 위한 HPGe 검출기의 전계수 또는 동시계수모드에서의 광대역 계측효율 보정)

  • 송병철;박용준;지광용
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy(NIPS) system measures the prompt gamma-ray emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many element in either solid or liquid wastes. In this study, the full-energy-peak (FEP) efficiency calibration for a HPGe detector was constructed in the ${\gamma}$-ray energy range from 80 keV to 8 MeV, using $^{l33}$Ba and >TEX>$^{152}Eu$ RI sources and $ ^{35}Cl(n, ${\gamma}$)^{36}Cl$ thermal neutron captured reaction. The FEP efficiency curve for the higher energies using the $^{35}Cl(n, ${\gamma}$)^{36}Cl$ reaction was normalized with the curve obtained from the RI sources, since the accurate activity of its prompt ${\gamma}$-ray is unknown. The average thermal neutron flux was theoretically calculated using the FEP efficiency curve for the KCl standard solutions. The NIPS system equipped with a ${\gamma}$-${\gamma}$ coincidence setup with two n-type coaxial HPGe detectors was considered in order to reduce the interfering ${\gamma}$-ray background. The FEP efficiency curve for the ${\gamma}$-${\gamma}$ coincidence system was also obtained for full energy range. The performance of the normal and coincidence NIPS system was tested by comparing signal-to-noise ratio in each mode using the reference sample.e.

  • PDF

The characteristics of nuclear powered submarine and the use of enriched uranium (원자력 추진 잠수함의 특성과 농축우라늄 사용)

  • Jang, Jun-Seop
    • Strategy21
    • /
    • s.41
    • /
    • pp.261-293
    • /
    • 2017
  • Nuclear power is a way of attaining an enormous amount of energy with relatively small amount of resources and after it has been introduced to the submarine since 1954, there are approximately 150 of nuclear powered submarine currently on a mission around the world. This is due to the maneuverability, mountability and covertness of nuclear submarines. However, there are other tasks, not only the high level of nuclear technology that are needed to be dealt with in order to construct nuclear powered submarine. The biggest task of all is to secure the enriched uranium. Accordingly, this research is about the way of enriching and securing the nuclear fuel that are used in the nuclear submarine with the characteristics, merits and demerits of the nuclear submarine. Due to the fact that the pressurized water reactor in South Korea is the reactor that was originally built for the development of nuclear powered submarine, many parts is designed to be suitable for the submarine propulsion. However, in order to apply this to submarine it is needed to consider additional requests such as the position of reactor, accident-coping system, radioactive covering, reactor output adjustment and ship's pitch and roll in order to apply this to submarine. Nuclear submarines have much higher speed based on the powerful propulsion in comparison with diesel-electric submarine and also have bigger loading area. Besides, there is no need to snorkel and they also have advantages in covertness with the multi-noise proof system. The nuclear technology in South Korea has seen the dramatic development since 1962 and in 1998 reached to the level that we have succeeded in the localization of nuclear plant and exported the world-class one-piece small-sized reactor (SMART) to UAE. To operate these reactors, we import the whole quantity of low-enriched uranium and having our own uranium enrich facility is not probable because of the budget and international regulations. With the ROK/US nuclear agreement revised on 2015 November, the enrichment of uranium that are available without special permission has changed up to 20%. According to the assumption that we use the 20% enrichment of Uranium on U.S. virginia class submarine, it is necessary to change the fuel after 11 years and it will cause additional cost of 1 billion dollars. But the replace period by the uranium's enrichment rate is not fixed so that it is possible to change according to the design of reactor. Therefore, I would like to make a suggestion on two types of design concepts of nuclear submarine that can be operated for 30 years without nuclear fuel change by using the 20% enriched uranium from ONNp.First of all, it is possible by increasing the size of reactor by 3 times and it results in the 1,000t increase of the weight. And secondly, it is by designing the one piece reactor to insert devices such as steam turbine, condenser into the inside of nuclear core like the Rubis class submarines of France.

Trends of Study and Classification of Literatures on Environmental Pollution in Korea (우리나라에서의 환경오염 관련 문헌분류 및 연구동향)

  • 배준형;이종영;장봉기
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.37-48
    • /
    • 1996
  • The purpose of this study is to provide the valuable basic information that helps set the advanced direction of study in environmental pollution in the future. It classifies and analyzes 6, 531 papers according to their years, fields, and contents from 1962 to 1993 in Korea through Chunrian, a PC communication network, National Environment Research Institute(1989) in Seoul. Classifying papers by their fields, this study shows 19.6%(1, 281 papers) of total papers on water pollution, on which most emphasis was placed in the studies, 17.2%(1, 121 papers) on general remarks, 14.6%(952 papers) on environmental ecology, and 13.6%(891 papers) on air pollution. Classifying papers by their contents, this study tells us that the survey of state and evaluation of pollution degree took 28%(1, 829 papers) of total papers, and it seemed the most active study was carried out on this content. It then shows us that the treatment technology and mechanism shared 17.5%(1, 144 papers), and facilities and design took 1.9%(127 papers) which needed more studies in the future. As for the trends of study, the papers published until 1979 show that the water pollution accounted for 28.9% of total studies, on which the greatest emphasis was placed, while the papers in 1990s tell us that general remarks 34.7%, air pollution 14.9%, and water pollution 14.1%. It also shows that treatment technology and mechanism has had more importance since 1980s in water pollution, noise and vibration, waste materials, human wastes, and radioactive pollution. However, in sea pollution, policy and standard rather than treatment technology or method of measurement and analysis has been considered a more important one in 1990s. Analyzing the studies on general remarks, it tell us that the paper on environmental act, which were frequently conducted, accounted for 33.3% until 1979, while the papers on the environmental policy, in which the highest interest was kept, accounted 34.6% in 1990s. This study concludes that most papers had examined the survey on status and evaluation of pollution degree before 1980, while studies on solving the problems of environmental pollution have had more importance in the 1980s and 1990s. Therefore, in the future, more studies should be conducted actively on policy development to solve the problems of environment pollution as well as on encouragement of environmental consciousness.

  • PDF