• Title/Summary/Keyword: radioactive medicine

Search Result 322, Processing Time 0.034 seconds

Study on Renal Anemia - A Double Tracer Study on Iron Metabolism and Red Cell Life Span in Chronic Renal Diseases using Radioactive Iron ($^{59}Fe$) and Chromium($^{51}Cr$) - (신성빈혈(腎性貧血)에 관(關)한 연구(硏究) - 만성신질환(慢性腎疾患)의 철대사(鐵代謝) 및 적혈구수명(赤血球壽命)에 관(關)하여 -)

  • Jung, Kyung-Tae;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.2 no.1
    • /
    • pp.27-41
    • /
    • 1968
  • The ferrokinetics and red cell life spans of the patients with chronic glomerulonephritis were investigated by the double tracing method using radioactive iron ($^{59}Fe$) and chromium ($^{51}Cr$). According to the serum NPN levels, the patients were subdivided into 3 groups: Group 1. 6 patients, had the levels below 40 mg/dl Group 2. 6 patients, had the levels between 41 mg/dl to 80 mg/dl Group 3. 10 patients, had the levels above 80 mg/dl The results were as follows: 1) Red blood cell-, hematocrit- and hemoglobin values were moderately reduced in patients with normal serum NPN levels, while markedly reduced in patients with elevated serum NPN levels. 2) The plasma volume was increased, while the red cell volume was decreased in patients with elevated serum NPN levels, hence, total blood volume was unchanged. 3) The serum iron level was slightly reduced h patients of groups 1 and 2, while was within the normal ranges in patients of group 3. 4) i) In patients with normal serum NPN levels, the plasma iron disappearance rate, red cell iron utilization rate, red cell iron turnover rate, daily red cell iron renewal rate, circulating red cell iron and red cell iron concentration were within the normal ranges, while the plasma iron turnover rate was slightly reduced. ii) In patients with elevated serum NPN levels, the plasma iron disappearance rate was delayed, while the plasma iron turnover rate was within the normal ranges. The red cell iron utilization rate, red cell iron turnover rate and circulating red cell iron were decreased and the period in which the red cell iron utilization rate reachd its peak was delayed in Group 3 patients. The daily red cell iron renewal rate and the red cell iron concentration were unchanged. iii) The mean red cell life span was within the normal ranges in patients with normal serum NPN levels, while was shortened in patients with elevated serum NPN levels.

  • PDF

A Study on the Tracking of Count-Based Volumetric Changes in Nuclear Medicine Imaging (핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰)

  • Ji-Hyeon Kim;Jooyoung Lee;Hoon-Hee Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.57-69
    • /
    • 2024
  • Purpose: Quantitative analysis through count measurement in nuclear medicine planar images is limited by analysis techniques that are useful for obtaining various clinical information or by organ overlap or artifacts in actual clinical practice. On the other hand, the use of SPECT tomography images is quantitative analysis using volume rather than planar, which is not only free from problems such as projection overlap, but also has excellent quantitative accuracy. In the use of developing SPECT quantitative analysis technology, this study aims to compare the accuracy of quantitative analysis between ROI of the conventional planar images and VOI of the SPECT tomographic images in evaluating the count change happened by the volume change of the source. Materials and Methods: A 99mTcO4- source(200.17 MBq) was filled with sterilized water in the syringe to create a phantom with an inner diameter volume of 60 cc, and a planar image and a SPECT image were obtained by reducing the volume by 15 cc (25%) respectively. ROI and VOI(threshold: 1~45%, 5% interval) were set for each image obtained to estimate true count and measure the total count, and compared with the preseted volumetric change rate(%). Results: When volume changes of 25%, 50%, and 75% occurred in the initial volume of 60 cc(100%) of the phantom, the average count changes of the measured planar image were 26.8%, 53.2%, 77.5%, and the average count changes of the SPECT image were 24.4%, 50.9%, and 76.8%. In this case, the VOI size(cm3) set showed an average change rate of 25.4%, 51.1%, and 76.6%. The highest threshold value for the accuracy of radioactive concentration by VOI size (average error -1.03%) was 35%, and the VOI size of the same threshold had an error of -17.1% on average compared to the actual volume. Conclusion: On average, the count-based volumetric change rate in nuclear medicine images was able to track changes more accurately using VOI than ROI, but there was no significant difference with relatively similar value. However, the accuracy of radioactive concentration according to individual VOI sizes did not match, but it is considered that a relatively accurate quantitative analysis can be expected when the size of VOI is set smaller than the actual volume.

Infarction of Renal Transplant with Extrarenal Excretion of Tc-99m $MAG_3$ Demonstrated by Renal Scintigraphy (Tc-99m $MAG_3$ 신장스캔에서 신외 배설과 함께 발견된 이식신 경색)

  • Lim, Seok-Tae;Kim, Min-Woo;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.199-201
    • /
    • 2003
  • A 38-year-old woman with end stage renal disease received a living related donor-renal transplant to the right iliac fossa. She developed anuria a week later Tc-99m $MAG_3$ renal scintigraphy demonstrated no perfusion, uptake, or excretion of the radioactive tracer from the renal transplant. The expected area of the renal allograft appeared as a photopenic area with increased rim activity. The gallbladder and bowel activities were observed on delayed images at 24 hours. There was no blood flow within the renal artery on renal doppler examination. This case shows total absence of perfusion and function in the infarcted renal transplant with extrarenal excretion of Tc-99m $MAG_3$ caused by acute renal artery thrombosis.

Occult Papillary Thyroid Carcinoma Presenting as a Metastatic Pleural Effusion (전이성 흉수로 발현된 잠재성 유두상 갑상선암)

  • Lee, Kye-Young;Myong, Na-Hye;Kim, Keun-Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.594-599
    • /
    • 1995
  • Although papillary carcinoma of the thyroid generally follows an indolent course characterized by slow growth and the absence of distant metastases, several available reports suggest that metastasis to bone and/or lung parenchyma may occur infrequently. But pleural metastases are known to be very rare, so there have been only two case reports about the pleural metastases of papillary thyroid carcinoma in the literatures. Even the case of occult papillary thyroid carcinoma presenting as a metastatic pleural effusion has been never been reported. Recently we experienced a case with the chief complaint of dyspnea due to massive pleural effusion, the cytologic examination of which revealed the papillary carcinoma with psamomma bodies. The examination of the thyroid revealed no definite primary tumor. The total thyroidectomy was done with the plan of post-operative radioactive iodine treatment and the pathologic result confirmed the occult papillary microcarcinoma as expected. With the present case report, the extension of the clinical spectrum. of metastatic papillary carcinoma of the thyroid is expected.

  • PDF

Radiation Proctitis and Management Strategies

  • Dushyant Singh Dahiya;Asim Kichloo;Faiz Tuma;Michael Albosta;Farah Wani
    • Clinical Endoscopy
    • /
    • v.55 no.1
    • /
    • pp.22-32
    • /
    • 2022
  • Radiotherapy (RT) is a treatment modality that uses high-energy rays or radioactive agents to generate ionizing radiation against rapidly dividing cells. The main objective of using radiation in cancer therapy is to impair or halt the division of the tumor cells. Over the past few decades, advancements in technology, the introduction of newer methods of RT, and a better understanding of the pathophysiology of cancers have enabled physicians to deliver doses of radiation that match the exact dimensions of the tumor for greater efficacy, with minimal exposure of the surrounding tissues. However, RT has numerous complications, the most common being radiation proctitis (RP). It is characterized by damage to the rectal epithelium by secondary ionizing radiation. Based on the onset of signs and symptoms, post-radiotherapy RP can be classified as acute or chronic, each with varying levels of severity and complication rates. The treatment options available for RP are limited, with most of the data on treatment available from case reports or small studies. Here, we describe the types of RT used in modern-day medicine and radiation-mediated tissue injury. We have primarily focused on the classification, epidemiology, pathogenesis, clinical features, treatment strategies, complications, and prognosis of RP.

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

The Safety Assessment of Surrounding Dose on Nuclear Medicine Test by Use The F-18 FDG (F-18 FDG를 이용한 핵의학 검사에서 주변 선량의 안전성 평가)

  • Kwak, Byung-Joon;Ji, Tae-Jeong;Min, Byung-In
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.157-162
    • /
    • 2009
  • Radioactive medicines are used a lot owing to the increase of a PET-CT examination using glucose metabolism useful for the early diagnosis of diseases. Therefore, the spatial dose that is generated from patients and their surroundings causes the patients' guardians and health professional to be exposed to radiation. However, they get unnecessarily exposed to radiation because medical institutions lack in space for isolation and recognition of the examination. This research intended to examine the spatial dose rates by measuring the dose emitted from the patient for 48 hours to whom F-18 FDG was administered. The spatial dose rates that were measured 100cm away from the patient's body after F-18 FDG was injected were $65.88{\mu}$Sv/hr at 60-minute point, $45.13{\mu}$Sv/hr at 90-minute point, $9.88{\mu}$Sv/hr at 6-hour point, and $1.24{\mu}$Sv/hr at 12-hour point. When the dose that the guardian and health professional got was converted into the annual(240-day working) accumulative dose, it was examined that the guardian received 81.56 mSv/yr and health professional received 49.36mSv/yr. In addition, the result has revealed that the dose that the patient received from one time of PET-CT examination was 3.75mSv/yr, which is 1.5 times more when compared with the annual natural radiation exposure dose.

Radionuclide identification based on energy-weighted algorithm and machine learning applied to a multi-array plastic scintillator

  • Hyun Cheol Lee ;Bon Tack Koo ;Ju Young Jeon ;Bo-Wi Cheon ;Do Hyeon Yoo ;Heejun Chung;Chul Hee Min
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3907-3912
    • /
    • 2023
  • Radiation portal monitors (RPMs) installed at airports and harbors to prevent illicit trafficking of radioactive materials generally use large plastic scintillators. However, their energy resolution is poor and radionuclide identification is nearly unfeasible. In this study, to improve isotope identification, a RPM system based on a multi-array plastic scintillator and convolutional neural network (CNN) was evaluated by measuring the spectra of radioactive sources. A multi-array plastic scintillator comprising an assembly of 14 hexagonal scintillators was fabricated within an area of 50 × 100 cm2. The energy spectra of 137Cs, 60Co, 226Ra, and 4K (KCl) were measured at speeds of 10-30 km/h, respectively, and an energy-weighted algorithm was applied. For the CNN, 700 and 300 spectral images were used as training and testing images, respectively. Compared to the conventional plastic scintillator, the multi-arrayed detector showed a high collection probability of the optical photons generated inside. A Compton maximum peak was observed for four moving radiation sources, and the CNN-based classification results showed that at least 70% was discriminated. Under the speed condition, the spectral fluctuations were higher than those under dwelling condition. However, the machine learning results demonstrated that a considerably high level of nuclide discrimination was possible under source movement conditions.

Optimization of Inpatient Management of Radioiodine Treatment in Korea (우리나라에서 방사성옥소입원치료 관리 최적화)

  • Park, Min-Jae;Kim, Jung-Hyun;Jang, Jung-Chan;Kim, Chang-Ho;Jeong, Jae-Min;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.261-266
    • /
    • 2008
  • We established a model to calculate radioactive waste from sewage disposal tank of hospitals to optimize the number of patients receiving inpatient radioiodine therapy within the safety guideline in our country. According to this model and calculation of radioactivity concentration using the number of patients per week, the treatment dose of radioiodine, the capacity and the number of sewage tanks and the daily amount of water waste per patient, estimated concentration of radioactivity in sewage waste upon disposal from disposal tanks after longterm retention were within the safety guideline (30 Bq/L) in all the hospitals examined. In addition to the fact that we could increase the number of patients in two thirds of hospitals, we found that the daily amount of waste water was the most important variable to allow the increase of the number of patients within the safety margin of disposed radioactivity. We propose that saving the water amount be led to increase the number of patients and they allow two patients in an already furnished hospital inpatient room to meet the increasing need of inpatient radioiodine treatment for thyroid cancer.

The Changes in Serum TSH-Binding Inhibiting Immunoglobulin (TBII) Activity and Thyroglobulin Level after Treatment with Radioactive Iodine ($^{131}I$) in Graves' Hyperthyroidism (그레이브스 갑상선기능항진중 환자에서 방사성 옥소($^{131}I$) 투여 후 혈청 갑상선자극 면역글로불린 (Thyrotropin-Binding Inhibiting Immunoglobulin, TBII)활성도 및 Thyroglobulin의 변화)

  • Son, Tae-Yong;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.200-205
    • /
    • 1994
  • 그레이브스 갑상선기능항진증은 자가면역질환의 하나로 방사성 옥소가 간편하고 경제적이며 효과적인 치료법임이 알려져 있는데 방사성 옥소 투여 후 갑상선 조직의 자극 및 파괴에 따라 각종 항원의 노출의 증가와 이에 대한 자가항체의 변동이 예상된다. 저자들은 추정 갑상선 무게를 고려한 6-10 mCi의 방사성 옥소를 투여 받은 그레이브스 갑상선기능항진증 환자 90명을 2년간 추적하여 치료 전 후의 혈청 갑상선자극 면역글로불린(TBIIl)활성도와 thyroglobulin 및 antithyroglobulin antibody의 변화를 관찰하였다. 1) 대상환자 90명의 연령분포는 14-58세(중앙치 30)였으며 여자가 72명(80%)이었다. 2) 평가대상 환자 중 치료 전 TBIIl 활성도가 정상범위였던 경우는 15명(30%)이었고 증가된 경우는 35명(70%)이었다. 치료 전보다 치료 3개월 후에 TBII 활성도가 더 증가된 경우는 31명(62% )이었다. 3) TBII 활성도가 치료 전에 증가하였거나, 치료 전에 정상범위였다가 치료 3개월 후에 증가한 환자의 TBII 활성도의 동태는 치료 3개월 후에 가장 높았고 그 후 점차 감소하였다. 이들의 TBIIl 활성도가 15%이내로 정상화된 정도는 치료 후 6개월에 40%, 12개월에 82%였다. 4) 치료 전 antithyroglobulin antibody가 양성인 경우 80%에서 3개월 후에도 혈청 thyroglobulin의 동태는 치료 3개월 후에 높았다가 증가가 없었으며 치료 전 antithyroglobulin antibody가 음성인 경우 60%에서 치료 3개월 후에 혈청 thyroglobulin의 증가가 있었다. 5) antithyroglobulin antibody가 음성인 경우의 혈청 thyroglobulin의 동태는 치료 3개월 후에 높았다가 점차 감소하는 경향을 보였으며 antithyroglobulin antibody가 양성인 경우의 혈청 thyroglobulin의 동태는 치료 후 시간이 지남에 따라 점차 감소하였다. 6) 치료 전 antithyroglobulin antibody가 음성인 경우 치료 후 시간 경과에 따라 동시에 측정한 혈청 TBII 활성도와 thyroglobulin 사이에는 통계적으로 유의한 상관관계가 있었다(p<0.01). 한편 치료 전 antithyroglobulin antibody가 양성인 경우 치료 후 시간 경과에 따라 동시에 측정한 혈청 TBII 활성도와 thyroglobulin 사이에는 통계적으로 유의한 상관관계가 없었다(p= 0.16). 이상의 결과로 방사성 옥소를 투여 받은 그레이브스 갑상선기능항진증 환자에서 혈청 TBII 활성도는 항갑상선제를 투여 받은 경우와는 달리 초기에 증가하였다가 시간이 지남에 따라 점차 감소함을 알 수 있었으며 그 감소 정도는 항갑상선제만을 쓴 경우보다 더 빠를 것으로 생각된다. 따라서 혈청 TBII 활성도와 thyroglobulin은 방사성 옥소 치료효과의 관찰에 중요한 역할을 할 것으로 생각되며 특히 antithyroglobulin antibody가 음성인 경우 혈청 thyroglobulin은 혈청 TBII 활성도를 반영할 것으로 사료된다.

  • PDF