• Title/Summary/Keyword: radiation wave

Search Result 746, Processing Time 0.03 seconds

An internal multi-band antenna for mobile handset using two slots (두 개의 슬롯을 이용한 단말기용 다중대역 내장형 안테나)

  • Ahn, Sang-Kwon;Choi, Sunho;Kwak, Kyung-Sup
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.13 no.1
    • /
    • pp.61-66
    • /
    • 2014
  • This paper describes the design, fabrication, and measurement of a compact hexa-band coupling antenna for 4G mobile handset using a small element with two slots. In order to obtain sufficient bandwidth (LTE700, GSM850, GSM900, GSM1800, GSM1900, UMTS) with a Voltage Standing Wave Ratio $(VSWR){\leq}3:1$, two slots are inserted in the small element, and coupling patch is used. The measured result of the fabricated antenna provides 410MHz bandwidth form 0.688 to 1.098GHz and 643 MHz bandwidth form 1.607 to 2.250GHz (${\leq}VSWR 3:1$) with the gain ranging from -0.52 to 4.68 dBi. Also, a good radiation pattern is achieved within the hexa-band (0.698-0.960GHz and 1.710-2.170GHz) range.

Quantitative Analysis of Enlarged Cervical Lymph Nodes with Ultrasound Elastography

  • Zhang, Jun-Peng;Liu, Hua-Yan;Ning, Chun-Ping;Chong, Jing;Sun, Yong-Mei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7291-7294
    • /
    • 2015
  • Purpsoe: To investigate the diagnostic value of quantitative analysis of a tissue diffusion and virtual touch tissue imaging quantification (VTIQ) technique with acoustic radiation force impulse (ARFI) elastography for assessing enlarged cervical lymph nodes. Materials and Methods: Fifty-six enlarged cervical lymph nodes confirmed by pathologic diagnoses were covered in the study. According to the results of pathologic diagnosis, patients were classified into benign and malignant groups. All the patients were examined by both conventional ultrasonography and elastography. AREA% and shear wave velocity (SWV) in ROI of different groups were calculated and compared using ROC curves. Cut-off points of AREA% and SWV were determined with receiver operating characteristic curves. Results: Final histopathological results revealed 21 cases of benign and 35 cases of malignant lymph nodes. The mean values of AREA% and SWV in benign and malignant groups were $45.0{\pm}17.9%$ and $2.32{\pm}0.57m/s$, and $61.3{\pm}21.29%$ and $4.36{\pm}1.25$)m/s, respectively. For the parameters of elastography, "AREA%" and SWV demonstrated significant differences between groups (p=0.002). AREA% was positively correlated with SWV with a correlation coefficient of 0.809 (P<0.001). Conclusions: Stiffness of different lymph node diseases in patients may differ. Elastography can evaluate changes sensitively and provide valuable information to doctors. The study proved that the VTIQ elastography technique can play an important role in differential diagnosis of lymph nodes.

Image Evaluation and Association Analysis of the Cardiovascular Disease of the Degree of Pancreatic Steatosis in Ultrasonography

  • Cho, Jin-Young;Ye, Soo-Young;Ko, Seong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.375-379
    • /
    • 2016
  • Increasing fat tissue of obese people, increases the rate of cardiovascular disease, diabetes, metabolic syndromes and dyslipidemia. An increase in the focal tissue of pancreas is a known risk factor of these diseases. Although there exists sufficient research on the diagnosis and treatment of pancreatic cancer, studies have been done on fatty pancreas. In this study, based on ultrasound imaging and using a texture characteristic of GLCM, fatty pancreas was divided into three categories: mild, moderate and severe. We compared and analyzed the three groups was by Pancreatic ultrasonography and body characteristics, serological tests, pressure and the degree of arteriosclerosis, against normal control group. The following parameters of control and test groups were measured: WC (waist circumference),BMI (body mass index), TC (total cholesterol), TG (triglyceride), HDL-C (High-density lipoprotein cholesterol) and LDL-C (Low-density lipoprotein cholesterol), SBP (systolic blood pressure), BST (Blood Sugar Test) and aortic PWV (pulse wave velocity). We observed the values correspondingly increasing fat deposition. However, ABI (Ankle Brachial pressure index) stenosis and HDL-C levels decreased with increasing fat deposit (p <0.05); a drop in these parameters are known to be harmful to the human body. The difference in texture characteristics between normal control group and pancreatic fatty group (mild, moderate, and severe) was statistically confirmed. Ultrasound imaging of pancreatic steatosis categorized the disease as mild, moderate and severe based on the characteristic texture. In conclusion, we observed on increase in metabolic syndrome, dyslipidemia, and arteriosclerosis, proportional to the degree of pancreatic fat deposition. The escalation of these diseases was confirmed and was directly related with predictors of cardiovascular diseases.

Diffraction Analysis of Multi-layered Grating Structures using Rigorous Equivalent Transmission-Line Theory (정확한 등가 전송선로 이론을 사용한 다층 격자 구조의 회절특성 분석)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.261-267
    • /
    • 2015
  • The eigenvalue problems involving the diffraction of waves by multi-layered grating configurations can be explained by rigorous modal expansion terms. Such a modal solution can be represented by equivalent transmission-line networks, which are generalized forms of simple conventional circuits. This approach brings considerable physical insight into the grating diffraction process of the fields everywhere. In particular, the transmission-line representation can serve as a template for computational algorithms that systematically evaluate dispersion properties, radiation effects and other optical characteristics that are not readily obtained by other methods. To illustrate the validity of the present rigorous approach, the previous research works are numerically confirmed and the results agree well each other.

Study on Variation of Local Atmospheric Circulation Due to Road Development in Mountain Area (산악지역 도로건설에 따른 국지 대기순환의 변화에 관한 연구)

  • Hwang, Soo-Jin;Seo, Kwang-Soo;Lee, Soon-Hwan
    • Journal of the Korean earth science society
    • /
    • v.25 no.2
    • /
    • pp.94-108
    • /
    • 2004
  • In order to clarify the efficiency of ground level change in Ice-valley on atmospheric circulation, numerical experiment was carried out. The circulations over the slope in North and South are different due to the topography and short wave radiation in Ice-valley. Therefore the circulations in both side are asymmetric and the asymmetric circulations are kept on at 1800 LST. A small difference of the atmospheric circulations formation is made due to the road construction at night. The reason may be the weakness of sensible heat flux from the road and other factors except that the sensible heat is not a principal factor in road construction. The construction of road is associated with growing of sensible heat from the road surface. For this reason, in case of daytime, ascending wind in north slope is more stronger with the road than that without road. The maximum wind speed becomes 4.67 m/s after road construction. And the position of the road is also an important factor in estimation of mesoscale circulation in mountainous area.

Design of RFID Passive Tag Antennas in UHF Band (UHF 대역 수동형 RFID 태그 안테나 설계)

  • Cho Chihyun;Choo Hosung;Park Ikmo;Kim Youngkil
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.9 s.100
    • /
    • pp.872-882
    • /
    • 2005
  • In this paper, we examined the operating principle of a passive tag antenna for RFID system in UHF band. Based on the study, we proposed a novel RFID tag antenna which adopts the inductively coupled feeding structure to match antenna impedance to a capacitively loaded commercial tag chip. The proposed tag antenna consists of microstrip lines on a thin PET substrate for low-cost fabrication. The detail structure of the tag antenna were optimized using a full electromagnetic wave simulator of IE3D in conjunction with a Pareto genetic algorithm and the size of the tag antenna can be reduced up to kr=0.27($2 cm^2$). We built some sample antennas and measured the antenna characteristics such as a return loss, an efficiency, and radiation patterns. The readable range of the tag antenna with a commercial RFID system showed about 1 to 3 m.

Recurrent T-cell lymphoma occurred in the vocal fold: a case report (성대에서 발견된 재발성 T세포 림프종에 대한 증례 보고)

  • Kang, Karam;Choi, In Hak;Lee, Doh Young;Baek, Seung-Kuk;Jung, Kwang Yoon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.33 no.2
    • /
    • pp.55-58
    • /
    • 2017
  • Background. Lymphoma of the vocal fold is extremely rare due to low lymphoid content in the larynx. To date, fewer than 100 cases of laryngeal lymphoma have been reported; however, none of these literatures are concerned about exclusive laryngeal involvement of recurred lymphoma which initially appeared in other body sites. Specific consensus about management for these patients yet to exist, due to its rare occurrence; however, the main modality of treatment is chemotherapy alone or in combination with radiation therapy. Case. Herein, we report a case of a 51-year-old female patient who had recurrent T-cell lymphoma developing in bilateral vocal folds. The patient was originally diagnosed of T-cell lymphoma in right colic flexure 10 years ago, and was cured by chemotherapy. Immunohistochemical stain revealed the histologic type of recurred tumor in the vocal folds that are identical to the previously cured lymphoma. Conclusion. To the best of our knowledge, this was the first case that recurrent lymphoma occurred solely in the vocal folds. Despite its rarity, lymphoma should be put in the index of suspicion among those patients with decreased vocal fold mucosal wave without definite vocal fold mass who had a history of cured lymphoma.

A Case Study on the MRI Profitability of a General Hospital (한 종합병원의 MRI 채산성 사례 연구)

  • Kang, Chang-Yeol;Song, Sung-Ho;Lim, Kyeong-Tae
    • The Korean Journal of Health Service Management
    • /
    • v.4 no.1
    • /
    • pp.145-156
    • /
    • 2010
  • The purpose of this study is one of high price medical equipment wished to grasp propriety factor about the MRI introduction, analyzing payability through cost accounting into compensation. It was investigated from January 1 to December 31, 2007 about the MRI of a General Hospital. Expectation availability was 23.2 cases, but actual availability did achievement more than 196.1% with 45.5 items. It is estimated that there are a lot of occurrence cases because great reasons that actual availability increases more than expectation availability is excellent resolving power than a CT, and is device that prefer to reason back that radiation damage is less in person body. The followings show the main results of this study. 1. The MRI was construed in order of cost accounting, wave and personnel expenses 45.4%, administrative expenses 53.0%, and material costs 1.6%. 2. According to CVP (Cost-volume-profit) analysis, BEP (Break Even Point) profit is 173,931,428 won for 11 months, and break even usage number of items are 37.5 cases, and separation usage number of items were confirmed by 1.4 cases. Therefore, was construed that can achieve BEP within 11 months though usage number of items keeps 1.4 items day to create the MRI's hospital operation profit. 3. Estimated limit profitability appears high by 96.7%, exceed fixed charges even if when is non-benefit and when it is benefit consider variable, is judged that the MRI's addition induction helps in hospital management enhancing earning rates.

The Effects of Sloshing on the Responses of an LNG Carrier Moored in a Side-by-side Configuration with an Offshore Plant (해양플랜트에 병렬 계류된 LNG 운반선의 거동에 슬로싱이 미치는 영향)

  • Lee, Seung-Jae
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.16-21
    • /
    • 2010
  • During the loading/offloading operation of a liquefied natural gas carrier (LNGC) that is moored in a side-by-side configuration with an offshore plant, sloshing that occurs due to the partially filled LNG tank and the interactive effect between the two floating bodies are important factors that affect safety and operability. Therefore, a time-domain software program, called CHARM3D, was developed to consider the interactions between sloshing and the motion of a floating body, as well as the interactions between multiple bodies using the potential-viscous hybrid method. For the simulation of a floating body in the time domain, hydrodynamic coefficients and wave forces were calculated in the frequency domain using the 3D radiation/diffraction panel program based on potential theory. The calculated values were used for the simulation of a floating body in the time domain by convolution integrals. The liquid sloshing in the inner tanks is solved by the 3D-FDM Navier-Stokes solver that includes the consideration of free-surface non-linearity through the SURF scheme. The computed sloshing forces and moments were fed into the time integration of the ship's motion, and the updated motion was, in turn, used as the excitation force for liquid sloshing, which is repeated for the ensuing time steps. For comparison, a sloshing motion coupled analysis program based on linear potential theory in the frequency domain was developed. The computer programs that were developed were applied to the side-by-side offloading operation between the offshore plant and the LNGC. The frequency-domain results reproduced the coupling effects qualitatively, but, in general, the peaks were over-predicted compared to experimental and time-domain results. The interactive effects between the sloshing liquid and the motion of the vessel can be intensified further in the case of multiple floating bodies.

The Study of Characteristic of Induced Erythema and Safety by UVB Lamp (UVB조사기의 홍반 발생 특성과 안전성에 관한 연구)

  • Park, Rae-Joon;Cho, Yong-Ho;Park, So-Hyun;Lee, Yoon-Mi
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.3
    • /
    • pp.79-87
    • /
    • 2006
  • Purpose: The present study purposed to examine induced characteristic or erythema and safety by medium wave ultra violet(UVB) lamp. Methods: We compared sunshine and UVB lamp using spectroradiometer and UV radiometer. For measuring sunshine irradiation, we used spectoradiometer and detected from 8 to 18 o'clock every each hour on the beach, playground and rooftop of a 5 story building. The subjects for erythema examination were 5 healthy subjects who have no pathologic history of photosensitivity reaction, psoriasis and vitiligo. They were exposed to UVB radiation at the abdominal area for 2 hours and after irradiation, we observed the change of skin color every 12 hours over a period of 1 week. Results: Between sunshine and UVB lamp, sunshine had higher data on the chromaticity coordinates, dominant and peak wavelength, bandwidth and purity than the UVB lamp but on the color temperature, brightness the UVB lamp had higher data than the sunshine. In comparison of sunshine and UVB lamp, UVB lamp irradiated constantly such as $3.9-4.4{\mu}W/cm^2$ at a distance of 100cm between bed and lamp which was same as early morning irradiation on the sunshine. The erythema didn't appear to any subject. Conclusion: This results suggest that the UVB lamp has lower irradiance as much as early sunshine. Therefore the UVB lamp had no influence of inducing erythema at a distance of 100cm between bed and lamp.

  • PDF