• 제목/요약/키워드: radiation treatment planning

검색결과 629건 처리시간 0.027초

코발트60 원격치료기에 대한 Semiuniversal Wedge Filter의 제작과 임상응용 (Construction of Semi-universal Wedge Filter and Clinical Application for Co-60 Teletherapy Unit)

  • 김명호;윤석록;신동오
    • 대한방사선치료학회지
    • /
    • 제3권1호
    • /
    • pp.45-50
    • /
    • 1989
  • 고 에너지 방사선으로 용적이 적은 표재성 종양 및 부정형의 체표면과 경사진 조사야에 대한 방사선 치료시 종양 용적내에 균등한 선량분포를 얻기 위해서 Wedge filter 기법이 많이 사용되고 있다. 본 연구의 목적은 코발트 $60{\Gamma}$선 치료를 위한 Semi-Universal Wedge filter의 제작과 임의의 조사야에 대한 최적한 출력 및 정확한 조작방법을 기술하고 방사선 치료계획의 최적화를 기하기 위해서 Wedge filter의 임상응용 방법을 제시하고자 한다.

  • PDF

호흡에 따른 간장용적의 변화와 정상조직 손상확율에 미치는 영향에 관한 연구 (Volumetrical changes of liver associated with breathing and its impact to normal tissue complication probability)

  • 조정희;김주호;이석;박재일
    • 대한방사선협회지
    • /
    • 제27권2호
    • /
    • pp.212-221
    • /
    • 2001
  • Ⅰ. Purpose : The aim of this study is to investigate geometrical and volumetrical changes of liver due to breathing and its impact to NTCP. In order to attain better treatment results it should be considered deliberately during planning session. Ⅱ. Method

  • PDF

간 종양의 방사선치료에서 위내용적과 종양 위치 간의 관계 (Relationship between Stomach Volume and Tumor Location in Radiation Treatment for Hepatic Tumors)

  • 전미진;이창걸;이익재;최원훈;최윤선;신동봉;김종대;김세준;하진숙;조윤진
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.75-83
    • /
    • 2010
  • 목 적: 간과 간 내에 생긴 암이 위내의 크기, 위치변화에 따라 종양의 위치변화와 경향성을 평가하기 위함이다. 방법 및 고찰: 2009년 3월부터 2010년 4월까지 강남세브란스병원을 내원한 간 종양을 가진 환자 중 CT-simulation (컴퓨터 단층촬영을 이용한 모의치료)을 하기 전 2주 내에 컴퓨터단층촬영이나 양전자컴퓨터단층촬영영상을 가진 환자 9명을 대상으로 하였으며, CT-simulation는 6시간 공복을 유지하고, 영상융합을 위한 컴퓨터단층촬영이나 양전자컴퓨터단층촬영은 촬영직전에 240~260 cc 가량의 물을 섭취하도록 하였다. 두 종류의 영상은 RTP (Radiation Treatment Planning, Pinnacle 8.0 h)에서 각각 환자의 뼈 구조를 중심으로 영상융합을 하였다. 결 과: 물 섭취양은 240~260 cc로 일정하였으나 물 섭취 후 위장의 크기는 259.3 cc부터 495.4 cc로 다양하였으며, 두 가지 다른 상태에서 찍은 컴퓨터단층촬영들에서 나타난 위장의 부피변화는 개인의 차이는 있지만, 평균 130 cc 정도의 부피증가가 측정되었으며, 이는 평균 174%의 증가에 해당된다. 종합적인 종양 중심점의 절대거리는 0.52 cm에서 3.04 cm으로 평균 1.52 cm의 움직임을 보였으며, 머리-다리(Cranial-Caudal)방향으로는 0.1 cm에서 1.35 cm으로 평균 0.44 cm의 움직임을 보였고, 왼-오른(Left-Right)방향으로는 0.05 cm에서 2.75 cm으로 평균 1.22 cm의 움직임을 보였고, 배-등(Ventral-Dorsal)방향으로는 0.05 cm에서 1.85 cm으로 평균 0.33 cm의 움직임을 보였다. 결 론: 개인차가 커서 위장의 운동을 관찰하여 종양의 움직임을 예측하는 것은 힘들지만 위장이 채워짐에 따라, 복잡한 경로를 통해 간 종양의 위치가 오른쪽으로 치우치는 것이 관찰되었다. 이에 간종양 치료 시 치료 정확도를 확보하기 위하여 공복상태를 유도하는 것을 권장한다. 반면 공복상태가 어려울 경우 환자의 위장의 부피와 움직임을 측정하여 치료계획 시 간 종양의 움직임을 고려하여 방사선 치료를 할 것을 권장한다.

  • PDF

후두와 종양의 방사선치료 시 표적용적의 결정을 위한 적절한 치료자세 연구 (Technical Review of Target Volume Delineation on the Posterior Fossa Tumor : An Optimal Head and Neck Position)

  • 윤상민;이상욱;안승도;김종훈;이병용;나영신;김태형;최은경
    • Radiation Oncology Journal
    • /
    • 제21권1호
    • /
    • pp.94-99
    • /
    • 2003
  • 목적 : 전산화단층촬영모의치료기를 이용한 후두와(posterio fossa) 종양의 방사선치료 시 어떤 자세로 치료하는 것이 치료범위 결정 및 치료계획에 유리한지에 대한 논의는 거의 이루어지지 않았다. 따라서 저자들은 후두와 치료의 적절한 치료자세를 설정하고 이를 이용한 치료계획을 소개하고자 본 연구를 시행하였다. 대상 및 방법 본 연구는 소뇌 충부에 발생한 수모세포종으로 수술 후 방사선치료를 받은 13세 남자 환아를 대상으로 하였다. 환아는 두개척수방사선치료를 일일선량 1.8 Gy로 30.6 Gy 시행 받은 후 후두와 영역에 추가방사선치료계획을 위해 전산화단층촬영모의치료를 받았다. 전산화단층촬영 시 복와위로 두부고정틀을 이용하여 자세를 고정하고 조영제를 주입하면서 두개골에서 경부 하방까지 촬영하였다. 단층 영상에 정상조직과 치료영역을 표시하였고 3차원 입체치료계획시스템을 이용해 비동일평면 입체조형 빔을 이용하여 치료계획을 세웠다 결과 : 전산화단층영상 촬영이 진행되는 동안 환아는 안정되고 편안한 자세를 유지할 수 있었고, 이 후 치료 중에도 자세를 재현하는데 큰 어려움이 없었다. 복와위 자세로 얻은 전산화단층영상에서 천막과일부 정맥동의 조영증강이 잘 관찰되어 후두와의 해부학적 범위를 결정하기가 용이하였다. 또 복와위 자세에서 후두와가 환아의 전면에 위치하게 되어 3차원 입체치료계획 시 방사선의 방향의 제약을 받지 않았고 치료 침대에 의한 선량분포의 불확실성이 없어서 보다 정확한 치료계획이 가능하였다. 결론 : 본 연구에서 후두와 치료 시 적절한 치료자세는 복와위임을 알 수 있었고, 안정되고 치료계획이 용이한 자세를 찾아내기 위해, 마취(sedation)가 필요하지 않거나 의식상태가 명료한 소아 환자를 통하여, 지속적인 연구가 이루어져야 할 것이다.

비인두암 Split VMAT 치료계획 유용성 평가 (Utility Evaluation of Split VMAT Treatment Planning for Nasopharyngeal cancer)

  • 박태양;김진만;권동열;임준택;김종식
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.13-20
    • /
    • 2022
  • 목 적: 비인두암 (Nasopharyngeal cancer) 방사선 치료 시 Tomotherapy을 이용한 IMRT는 종양 조직에 정확한 선량을 전달하며 정상조직에는 급격한 선량 감소의 효과가 있지만 MU가 높고 Beam On Time이 긴 단점이 있다. 본 연구는 Helical IMRT (Tomotherapy)와 VMAT (Linac : 2Arc), Split VMAT (Linac : 4Arc)의 치료계획을 시행하여 종양 및 정상 조직, 저 선량 분포의 차이를 분석하고 Split VMAT의 효율성을 평가해 보고자 한다. 대상 및 방법: 본원의 비인두암 환자 10명을 대상으로 하였으며 3개 치료계획 (Helical IMRT, VMAT, Split VMAT)을 비교하였다. Helical IMRT 치료 계획은 Precision® (Version 1.1.1.1, Accuray, USA)을 이용하였고 VMAT, Split VMAT 치료계획은 Pinnacle3® (Version 9.10, Philips, USA)을 이용하였다. 선량은 Daily Dose 2.4 Gy (GTV + 0.3 cm) / 2 Gy (CTV + 0.3 cm) 16 Fx으로 Total Dose 38.4 Gy / 32 Gy를 적용하였고 GTV + 0.3 cm (P_GTV)가 V38.4Gy이 95%가 되도록 처방하였다. VMAT은 360° 2Arc, Split VMAT은 좌, 우, 상, 하로 Field를 나누고 360° 4Arc, 6MV를 사용하였다. 평가는 종양 및 정상조직, 저 선량 영역의 차이를 비교하여 치료 계획의 Quality를 평가하였고 Beam On Time을 비교하여 효율성을 평가하였다. 결 과: 대상 환자들의 3개 치료계획 (Helical IMRT, VMAT, Split VMAT)의 평가 항목 평균 값은 P_GTV의 H.I (Homogeneity Index)는 (1.04, 1.11, 1.1), P_CTV의 C.I (Conformity Index)는 (1.03, 0.99, 1.00)이었다. RT Parotid Gland의 평균 선량 (Gy)은 (14.54, 17.06, 14.76), LT Parotid Gland의 평균 선량 (Gy)은 (14.32, 17.32, 15.09), P_Cord (Spinal Cord + 0.3 cm)의 최대 선량 (Gy)은 (20.57, 22.59, 21.06), Brain Stem의 최대 선량 (Gy)은 (22.35, 23.99, 21.68)이었다. 50% isodose curve (cc)는 (1332, 1132.5, 1065.2)이었다. Beam On Time (sec)은 (373.7, 130.7, 254.4)이었다. 결 론: Split VMAT은 두경부치료에 많이 사용하는 Helical IMRT와 비교했을 때 유사한 치료계획 Quality를 보이면서도 저 선량 영역을 줄여주며 Beam On Time이 줄어든 결과를 보여주었고 VMAT보다 좋은 결과를 보였다. Split VMAT은 비인두암 뿐만 아니라 다른 두경부암에서도 효과적이라 사료된다.

Deep Inspiration Breath Holding을 적용한 유방암 세기변조방사선치료 시 위치잡이오차 분석을 통한 선량 평가 (Dosimetric Comparison of Setup Errors in Intensity Modulated Radiation Therapy with Deep Inspiration Breath Holding in Breast Cancer Radiation Therapy)

  • 함일식;조평곤;정강교
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권2호
    • /
    • pp.137-143
    • /
    • 2019
  • The aim of this study was analyzed the setup error of breast cancer patients in intensity modulated radiation therapy(IMRT) with deep inspiration breath holding(DIBH) and was analyzed the dose distribution due to setup error. A total of 45 breast cancer cases were performed a retrospective clinical analysis of setup error. In addition, the re-treatment planning was carried by shifting the setup error from the isocenter at the treatment. Based on this, the dose distribution of PTV and OARs was compared and analyzed. The 3D error for small breast group and medium breast group and large breast group were 3.1 mm and 3.7 mm and 4.1 mm, respectively. The difference between the groups was statistically significant(P=0.003). DVH results showed HI, CI for the PTV difference between standard treatment plan and re-treatment plan of 14.4%, 4%. The difference in $D_5$ and $V_{20}$ of the ipsilateral lung was 5.6%, 13% respectively. The difference in $D_5$ and $V_5$ of the heart of right breast cancer patients was 6.8%, 8% respectively. The difference in $D_5$, $V_{20}$ of the heart of left breast cancer patients was 7.2%, 23.5% respectively. In this study, there was a significant association between breast size and significant setup error in breast cancer patients with DIBH. In addition, it was found that the dose distribution of the PTV and OARs varied according to the setup error.

유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석 (Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error)

  • ;;;;진호상;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.24-31
    • /
    • 2006
  • 유방암 환자의 방사선치료에 있어 치료도중(intrafractional) 및 분할 치료 간(intefractional)에 발생되는 오차를 측정하는 자동분석소프트웨어를 개발하였다. 오차 분석 결과는 3차원 입체조형 방사선치료를 임상에 적용하기에 앞서 적절한 치료계획용적(Planning Target Volume, PTV)을 설정하는 데 있어 매우 중요하다. 본 연구에서는 전자포탈영상장치(Electrical Portal imaging Device, EPID)로써 Portal Vision LC250 액체 충전형 이온화 검출기를 사용하였다(fast frame-averaging 모드, 초당 1.4 프레임, 256X256 픽셀). 12명의 환자에 대해 최소 7일 이상씩 영상을 획득하였다. 매 치료마다 평균 8 내지 9개의 영상을 각 빔에 대해 얻었다(분당 400 MU 선량률). 총 2,931 (720 측정을 포함하는)개의 영상을 정량적으로 분석할 수 있는 자동화 영상 분석 소프트웨어를 개발하였다. 이를 통해 호흡으로 인해 발생하는 치료도중 오차와 분할 치료간 발생하는 분할치료오차의 표준편차($\sigma$)들을 계산하였다. 신뢰 구간 95%로 임상표적체적(Clinical Target Volume, CTV)을 포함할 수 있는 PTV 마진은 $2\;(1.96\;{\sigma})$으로 계산되었다. 주로 호흡으로 인해 유발되는 치료도중오차를 보상하기 위해 필요한 PTV 마진은 2 mm에서 4 mm이었다. 반면에 분할 치료간 오차를 보상하기위해 필요한 PTV 마진은 7 mm에서 31 mm이었다. 12명의 환자에 대한 전체 평균오차는 17 mm이었다. 분할치료 간 오차는 호흡에 의해 유발되는 치료도중 오차에 비해 2배에서 15배까지 더 크게 나타났다. 유방암 치료에 있어 3차원 입체정형조사나 세기조절방사선치료(Intensity Modulated Radiation Therapy, IMRT)를 적용하기에 앞서 반드시 셋업 오차의 크기를 측정하여 PTV에 적절히 반영되어야 한다. 유방에 대한 3차원 입체정형조사나 세기조절방사선치료를 위해 반드시 필요한 것은 아니지만, 큰 PTV 마진을 줄여주기 위해서는 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)가 매우 유용하게 이용될 수 있다. 전자포탈영상장치 들은 본 보고서에서 기술한 바와 같은 자동분석소프트웨어를 반드시 포함하여야 한다. 이를 통해 수많은 EPID 영상들을 자동화 처리하고 오차분석을 시행함으로써 각 병원의 임상적용 방법 및 환경에 따라 상이하게 나타날 수 있는 오차의 크기를 감안한 적절한 PTV마진을 구하는데 도움을 얻을 수 있다. 이러한 장치들은 또한 최소의 노력으로 환자 치료를 관찰할 수 있는 귀중한 정보를 제공해 준다.

  • PDF

근접방사선조사에 의한 두경부암의 치료 (Brachytherapy in the Treatment of Head and Neck Cancer)

  • 류성렬
    • Radiation Oncology Journal
    • /
    • 제17권3호
    • /
    • pp.179-187
    • /
    • 1999
  • 치료선량의 증가와 주위 정상조직의 보호의 의미에서 근접치료의 효과는 입증되어 있다. 그러나 우리 나라에서는 아직 통상치료법으로 상용화가 되어 있지 않다. 저자는 저선량률 이리디움 근접조사치료의 임상적 경험을 바탕으로 두경부암에서의 근접조사치료의 역사, 사용되는 동위원소의 재원 및 특성, 시행 시 고려 하여야할 사항, 임상기술적인 문제, 방사선물리학적 문제 등을 검토하였고 저자의 임상 경험 185례의 치료성적을 분석하여 그 효과를 검증하였고 마지막으로 향후 발전방향을 제시하여 보았다.

  • PDF

방사선 치료의 국내 현황과 미래 (Present Status and Future Aspects of Radiation Oncology in Korea)

  • 허승재
    • Radiation Oncology Journal
    • /
    • 제24권4호
    • /
    • pp.211-216
    • /
    • 2006
  • 목 적: 최근 국내 방사선 치료의 발전 경향, 시설 장비와 인적 현황 등 인프라와 특징을 조사하고, 국내 방사선종양학분야의 발전 방향을 모색하려 한다. 대상 및 방법: 2006년도 방사선종양학과 전공의 지도 감독에 관한 실태 조사를 위하여 2006년 7월, 전문의, 전공의, 의학 물리사, 간호사, 방사선사 등 인력 및 치료 장비 인프라 조사와 함께 향후 확장 계획에 관한 조사를 실시하였다. 국내 61개 기관의 치료 시설 등급 결정은 IAEA 조사연구에서 사용한 기준에 따라서 분류하였다. 결 과: 2006년 7월 현재 한국에 설치된 방사선종양학과는 61개 병원이며, 132명의 전문의와 50명의 전공의를 포함하여 선량계산사 및 의학물리사 64명, 방사선사 369명 간호사 130명 등 745명의 인력이 2004년도 기준으로 28,789명 신환의 방사선치료 업무를 담당하고 있다. 방사선치료기는 메가볼티지 치료기가 104대 설치되어 있고 선형가속기가 96대, 코발트 원격치료기 2대, 토모치료기 3대, 사이버나이프가 2대, 한 대의 양성자 치료기가 설치되어 있다. 강내치료 장치는 41개 병원에 설치되어 있으며 이 중 35개 병원에서 고선량률 강내치료기, 6개 병원에서 저선량률 강내치료 장치가 설치 운영되고 있다. 국내 61개 병원의 IAEA기준에 따른 분류에서는 level 0이 2곳, level 1이 15곳, level 2가 19곳이고, level 3 즉 강도조절 방사선치료, 정위적 방사선치료, 수술 중 방사선치료가 가능한 시설이 25곳으로 매우 높은 질의 치료를 시행함을 보여준다. 결 론: 최근 치료시설과 방사선치료 관련 인적 인프라는 현저한 증가 추세에 있다. 즉, 선형가속기의 증가와 함께 코발트 치료기는 현격한 감소를 보이며 토모치료기, 사이버나이프 등 첨단 치료 장치가 증가하는 경향이다. 한국의 메가볼티지 치료기의 숫자는 인구 백만 명당 2.1대로서 향후 방사선치료의 필요성과 적응증이 계속 증가되는 추세에 있어서 치료기의 증가가 필요한 실정이다.

Field-in-Field Technique을 이용한 두경부암의 접합부위 선량개선에 관한 고찰 (Field-in-Field Technique to Improve Dose Distribution in the Junction of the Field with Head & Neck Cancer)

  • 김선명;이영철;정덕양;김영범
    • 대한방사선치료학회지
    • /
    • 제21권1호
    • /
    • pp.17-23
    • /
    • 2009
  • 목 적: 두경부암의 치료에 있어 상부 두경부의 양측면조사면과 하경부의 전방조사면의 접합부위에 균등한 선량을 조사하는 것은 매우 중요하다. 접합부위의 선량분포개선을 위하여 하경부 전방조사면의 치료시 Field-in-Field technique을 이용하여 부족선량(under dose)과 초과선량(over dose)으로 인한 선량불균등을 개선하고 일반치료와의 비교를 통하여 두경부암치료에 적용하고자 한다. 대상 및 방법: 상부 두경부의 양측면 조사시 빔의 확산으로 일어나는 입사점과 출사점의 선량차이를 알아보기 위하여 인체모형팬톰을 이용하였다. 인체모형팬톰을 전산화단층촬영하고 전산화치료계획에서 관심점의 선량비교를 시행하였고, 하경부 접합부위의 선량비율을 계산하여 이를 보정하였다. 조사면 접합부위의 선량분포를 알아보기 위하여 하경부의 접합부위에 저감도 필름을 놓고 일반적인 치료인 상부 두경부의 양측면조사와 하경부의 전방조사시 선량분포를 측정하였다. 또한, 상부 두경부 양측면 조사에 따른 빔의 확산을 고려한 Field-in-Field technique을 이용하여 하경부 전방조사를 할 때의 접합부위의 선량분포 차이를 측정하여 비교하였다. 접합부위의 관심점 선량을 알아보기 위하여 열형광선량계를 이용하여 인체모형팬톰내의 관심점에서의 선량변화를 비교, 분석하였다. 결 과: 전산화치료계획에서 하경부의 접합부위에 Field-in-Field technique을 적용하여 치료계획시 상부 두경부 양측면 조사와 선량합성을 한 경우 부족선량 영역의 선량이 4.7~8.65% 이상 증가하였다. 초과선량 영역의 선량도 2.75~10.45% 감소하였다. 또한, 저감도 필름을 이용한 측정에서는 부족선량영역에서 11.3% 증가, 초과선량영역에서 5.3% 감소한 것으로 나타났다. 열형광선량계를 이용한 관심점선량측정에서도 Field-in-Field technique 적용시 부족선량을 최소 7.5%에서 최대 17.6%까지 보정해주는 것으로 나타나 불균등한 선량분포를 개선할 수 있었다. 결 론: 전산화치료계획시 빔의 확산을 고려한 Field-in-Field technique을 적용하면 접합부위의 선량보정을 통해 냉점(cold spot)과 온점(hot spot)을 줄일 수 있었으며 특히, 빔의 확산에 따른 입사점의 부족선량을 보정할 수 있었다. 본 실험을 통해 Field-in-Field technique의 임상적용시 경부임파절의 저선량으로 인한 임파절전이에 대한 위험도를 감소시킬 수 있을 것으로 사료된다.

  • PDF