• 제목/요약/키워드: radiation sensor

검색결과 427건 처리시간 0.029초

Back Scatter Radiation이 CR영상(影像)에 미치는 영향(影響)

  • 이후민;김학성;조남수;고승일
    • 대한디지털의료영상학회논문지
    • /
    • 제2권1호
    • /
    • pp.92-95
    • /
    • 1996
  • Computed Radiography(CR) is a relatively new technology that relies on an image plate(IP) as an alternate x-ray sensor to screen/film. Standard CR cassettes do not have lead foil behind the IP to control scatter radiation. The result of this study indicate that such control is needed. In most screen/film cassettes, that lines the rear of the cassette eliminates back scatter radiation. This study was performed to Investigate on the effects of back scatter in CR images by size of exposure field, distance between the CR cassette and the wall of radiography room. 1. It showed artifacts from hinges and clips located on the back of CR cassette by back scatter radiation. 2. The greater effects of back scatter radiation in CR images was attributed to the greater size of exposure field and the longer distance between the CR cassette and the wall of radiography room.

  • PDF

실리콘기판 직접접합기술을 이용한 SOI 홀 센서의 제작과 그 특성 (Fabrication of a SOI hall sensor using Si-wafer direct bonding technology and its characteristics)

  • 정귀상
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권2호
    • /
    • pp.165-170
    • /
    • 1995
  • This paper describes the fabrication and characteristics of a Si Hall sensor fabricated on a SOI (Si-on-insulator) structure. The SOI structure was formed by SDB(Si-wafer direct bonding) technology and the insulator of the SOI structure was used as the dielectrical isolation layer of a Hall sensor. The Hall voltage and sensitivity of the implemented SDB SOI Hall sensors showed good linearity with respect to the applied magnetic flux density and supplied current. The product sensitivity of the SDB SOI Hall sensor was average 600V/A.T and its value has been increased up to 3 times compared to that of bulk Si with buried layer of 10.mu.m. Moreover, this sensor can be used at high-temperature, high-radiation and in corrosive environments.

  • PDF

이종접합을 이용한 방사선 영상 센서 개발 (Development of Radiation Image Sensor using Heterojunction)

  • 김영빈;윤민석;김민우;정숙희;김윤석;오경민;남상희;박지군
    • 한국방사선학회논문지
    • /
    • 제3권3호
    • /
    • pp.27-35
    • /
    • 2009
  • 본 연구에서는 적층 구조를 이용하여 누설전류를 저감 시키는 기술을 적용하여 PIB(Particle-In-Binder) 법을 이용한 방사선 영상 센서의 변환 물질을 개발하였다. 이는 디지털 방사선 영상 검출기의 두 가지 방식 중 하나인 직접방식에 사용되는 핵심 소자로 기존의 a-Se을 대체하여 더욱 효율이 높은 후보 물질들이 연구되어지는 가운데 태양전지와 반도체 분야에서 이미 많이 사용되어온 이종접합을 이용해 누설 전류를 저감 시키는데 그 목적이 있다. 본 연구에서 사용되는 PIB 제작 방법은 검출 물질 제작이 용이하고 높은 수율과 대면적의 검출기 제작에 적합하나 높은 누설 전류가 의료 영상에 있어서 문제가 되어 오고 있다. 이러한 단점을 보완하기 위해 적층 구조를 이용하여 누설 전류를 저감시킨다면 PIB법을 이용하여 간편하게 향상된 효율의 디지털 방사선 검출기를 제작 할 수 있다고 사료 되어 진다. 본 연구에서는 누설 전류와 민감도에 대한 전기적 신호를 측정하여 제작된 적층 구조의 방사선 검출 물질의 특성 평가가 이루어 졌다.

  • PDF

Blocking layer 적용을 통한 HgI2 방사선 변환센서의 신호대 잡음비 향상에 관한 연구 (Study on Improvement of Signal to Noise Ratio for HgI2 Radiation Conversion Sensor Using Blocking Layer)

  • 박지군;윤인찬;최수림;윤주선;이영규;강상식
    • 한국방사선학회논문지
    • /
    • 제5권2호
    • /
    • pp.97-101
    • /
    • 2011
  • 본 연구에서는 적충 구조를 이용하여 누설전류를 저감 시키는 기술을 적용하여 입자침전법을 이용한 방사선 영상 센서의 변환 물질을 개발하였다. 이는 디지털 방사선 영상 검출기의 두 가지 방식 중 하나인 직접방식에 사용되는 핵심 소자로 기존의 비정질셀레늄(a-Se)을 대체하여 더욱 효율이 높은 후보 물질들이 연구되어지는 가운데 태양전지와 반도체 분야에서 이미 많이 사용되어온 이종접합을 이용해 누설 전류를 저감 시키는데 그 목적이 있다. 본 연구에서 사용되는 입자 침전법 제조방법은 검출 물질 제작이 용이하고 높은 수율과 대면적의 검출기 제작에 적합하나 높은 누설 전류가 의료 영상에 있어서 문제가 되어 오고 있다. 이러한 단점을 보완하기 위해 적충 구조를 이용하여 누설 전류를 저감시킨다면 PIB법을 이용하여 간편하게 향상된 효율의 디지털 방사선 검출기를 제작 할 수 있다고 사료 되어 진다. 본 연구에서는 누설 전류와 민감도에 대한 전기적 신호를 측정하여 제작된 적충 구조의 방사선 검출 물질의 특성 평가가 이루어 졌다.

Development of low-cost, compact, real-time, and wireless radiation monitoring system in underwater environment

  • Kim, Jeong Ho;Park, Ki Hyun;Joo, Koan Sik
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.801-805
    • /
    • 2018
  • In this study, an underwater radiation detector was built using a GAGG(Ce) scintillator and silicon photomultiplier to establish an underwater radiation exposure monitoring system. The GAGG(Ce) scintillator is suitable for small radiation detectors as it strongly absorbs gamma rays and has a high light emission rate with no deliquescent properties. Additionally, the silicon photomultiplier is a light sensor with characteristics such as small size and low applied voltage. Further, a program and mobile app were developed to monitor the radiation coefficient values generated from the detector. According to the results of the evaluation of the characteristics of the underwater radiation monitoring system, when tested for its responsiveness to radiation intensity and reactivity, the system exhibited a coefficient of determination of at least 0.99 with respect to the radiation source distance. Additionally, when tested for its underwater environmental temperature dependence, the monitoring system exhibited an increase in the count rate up to a certain temperature because of the increasing dark current and a decrease in the count rate because of decreasing overvoltage. Extended studies based on the results of this study are expected to greatly contribute to immediate and continuing evaluation of the degree of radioactive contamination in underwater environments.

이동형 핵종 분석 장치용 CZT 반도체 검출기의 완충전극에 대한 연구 (A Study of Interface Layer on CdZnTe Radiation Sensor for Potable Isotope Identifier)

  • 조윤호;박세환;김용균;하장호
    • 방사선산업학회지
    • /
    • 제5권1호
    • /
    • pp.95-99
    • /
    • 2011
  • The electrical and mechanical properties of electrode for radiation detection are very important. In general, Au electrode and CZT crystal are combined to form ohmic contacts, and the best energy resolution is shown at the Au electrode. The metal contacts are fabricated by electroless deposition method, sputtering deposition method and thermal evaporation method. The electrode fabrication is easy with use of the thermal evaporation method, while an adhesive strength is weak. Thus interface materials such as Ag, Al and Ni were investigated to overcome defects generated by the this method. The thickness of the interface material between the Au electrode and the CZT crystal was 100 Angstroms, the Au electrode with thickness of 400 Angstroms was deposited. The Al+Au electrode is shown that the results of current-voltage and radiation response are similar to results of Au electrode.

스테레오 X-ray 시스템 검색기능 개선 연구 (The Study for the Efficient scanning of Stereo X-ray System)

  • 황영관;이남호;박종원
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.884-886
    • /
    • 2012
  • 일반적으로 사용하고 있는 X-선 검색장치는 대상물의 단면 정보만을 제공하고 있기에 검색 대상체를 식별에 어려움이 있어 이에 대한 개선이 요구되어 왔다. 스테레오 X-ray 시스템은 기존의 검색장치에 라인센서를 추가하여 검색 대상체에 대한 추가적인 정보를 제공함으로써 검색 효율을 높이도록 고안되었다. 본 논문에서는 선행 연구를 통해 개발된 스테레오 X-선 검색장치의 검색 속도를 향상시키기 위하여 정밀제어를 위한 제어부를 설계하고 이를 통해 이동체와 검색기의 스캔 속도를 동기화 하고 대상체의 검색 속도를 개선하였다. 본 연구의 결과는 대형 화물 스캔 장치 및 고속화물 스캔 장치 개발을 위해 활용될 수 있다.

  • PDF

센서를 이용한 자동 실내 온도 제어시스템 설계 및 구현 (Design and Implementation of Automatic Control System in Room using Sensor)

  • 정규태;이은진;김흥수
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 춘계학술대회
    • /
    • pp.326-328
    • /
    • 2015
  • 건물에서 창문의 기능은 태양 복사열의 유입을 통해 실내의 환경을 조성하고 동절기에는 난방비의 절감을 유도할 수 있으나, 다른 구조체에 비해 단열 성능이 크게 떨어져 5배 이상의 에너지가 손실되어 에너지 취약 부위이다. 또한 하절기에는 태양 복사열 과다로 냉방비가 가중된다. 이에 본 논문에서는 일반 가정에서 온도, 습도, 조도, 일사량 등의 실내 환경 정보를 이용하여 창문 자동 제어시스템을 개발하고자 한다. 이 시스템은 다양한 센서를 이용하여 실내 환경 정보를 수집하고 수집된 정보를 이용하여 모터를 제어하여 창문을 제어 할 수 있는 시스템이다. 가정 내 에너지 절감을 위하여 창호와 블라인드에 환경 자동화 서비스를 제공하여 사용자의 만족도를 높이고 스마트폰을 이용하여 시스템 제어를 통해 생활 속에 편리함을 제공하고자 한다.

  • PDF

초음파 이용 거리측정을 위한 센서 개발에 관한 연구 (Study on the Development of Sensors for Distance Measure Using Ultrasonic)

  • 박근철;이승희;박창수;김동원;김원택;전계록
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.46-50
    • /
    • 2014
  • In this paper, we report a novel algorithm based on phase displacement, which supplements conventional TOF methods for distance measurement using an ultrasonic wave. The proposed algorithm roughly measures the distance between the transmission part and the receiving part by using the initial TOF. Thereafter, the precise distance is determined by measuring the phase displacement value between the synchronizing transmission signal and the signal obtained at the receiving end. A distance measurement experiment using a micrometer was performed to verify the accuracy of the ultrasonic wave sensor system. We found that the mean errors from the one adopting the distance measurement algorithm based on phase displacement varied from a minimum of 0.03 mm to a maximum of 0.09 mm. In addition, the standard deviation varied from a minimum of 0.04 mm to a maximum of 0.07 mm, thus giving a precision of ${\pm}0.1$ mm.

A CMOS Bandgap Reference Voltage Generator for a CMOS Active Pixel Sensor Imager

  • Kim, Kwang-Hyun;Cho, Gyu-Seong;Kim, Young-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제5권2호
    • /
    • pp.71-75
    • /
    • 2004
  • This paper proposes a new bandgap reference (BGR) circuit which takes advantage of a cascode current mirror biasing to reduce the V$\_$ref/ variation, and sizing technique, which utilizes two related ratio numbers k and N, to reduce the PNP BJT area. The proposed BGR is designed and fabricated on a test chip with a goal to provide a reference voltage to the 10 bit A/D(4-4-4 pipeline architecture) converter of the CMOS Active Pixel Sensor (APS) imager to be used in X-ray imaging. The basic temperature variation effect on V$\_$ref/ of the BGR has a maximum delta of 6 mV over the temperature range of 25$^{\circ}C$ to 70$^{\circ}C$. To verify that the proposed BGR has radiation hardness for the X-ray imaging application, total ionization dose (TID) effect under Co-60 exposure conditions has been evaluated. The measured V$\_$ref/ variation under the radiation condition has a maximum delta of 33 mV over the range of 0 krad to 100 krad. For the given voltage, temperature, and radiation, the BGR has been satisfied well within the requirement of the target 10 bit A/D converter.