• 제목/요약/키워드: radiation safety

검색결과 1,461건 처리시간 0.037초

조기(TNM Stage I & II) 구강 편평세포암종의 초치료 실패 (The Failure of Initial Treatment for TNM Stage I & II Squamous Cell Carcinomas of the Oral Cavity)

  • 이현석;정한신;김태욱;손영익;백정환
    • 대한두경부종양학회지
    • /
    • 제21권1호
    • /
    • pp.26-31
    • /
    • 2005
  • Backgrounds and Objectives: Squamous cell carcinomas of the oral cavity(SCOC) in TNM stage I & II have relatively high chance to be cured compared to those in the advanced stage, but sometimes result in the treatment failure with poor prognosis. There have been few reports on the patterns of failure and the clinical courses for SCOC in stage I & II after the failure of initial treatment. This study is directed at identifying the clinical outcomes of stage I & II SCOC and the salvage rate after initial treatment and suggesting an optimal level of treatment by analyzing the patterns of failure. Material and Methods: The medical records of 36 patients with SCOC, initially diagnosed between 1995 and 2001 as TNM stage I & II were reviewed retrospectively. The patterns of failure, salvage treatment, clinical courses, and the survival of these subjects were analyzed. The minimum follow-up period of no-evidence of disease(NED) was 12 months with an average of 32.2 months. Results: Overall rate of the treatment failure in SCOC of stage I & II was 41. 7%(15/36 cases). Most of the treatment failure in the subjects with stage I tumors occurred in regional lymph node. Local failure was the most frequent form of failure in the subjects with stage II tumors after wide excision of primary tumor with elective neck dissection and/or radiation therapy. No significant correlation was noted between the safety margin and the local failure. Elective neck dissections in stage I & II SCOC had a tendency to reduce regional failure (p=0.055). The salvage rates at 24 months were 85.7% in stage I, and 37.5% in stage II. The 3-year survival rate after the failure of initial treatment was 55.0%. Conclusion: SCOC of stage I & II after the failure of initial treatment showed poor prognosis despite of the salvage treatments. This study implies that the elective neck dissections for regional lymph node should be required for SCOC of stage I & II to reduce the treatment failure.

국소방출방식 개념의 대향류 확산화염에서 CO2 소화효과에 관한 수치해석 연구 (A Numerical Study on the Extinguishing Effects of CO2 in Counterflow Diffusion Flames with the Concept of Local Application System)

  • 문선여;박충화;황철홍;오창보
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.55-62
    • /
    • 2012
  • 소화약제의 국소방출방식 개념이 적용될 수 있는 대향류 확산화염을 대상으로 $CO_2$ 소화약제의 소화기구를 재조명하기 위한 연구가 시도되었다. 이를 위해 연료 또는 공기류에 $CO_2$가 첨가된 낮은 총괄신장율의 $CH_4$/air 대향류 확산화염이 상세반응을 이용한 수치해석을 통해 검토되었다. 첨가된 $CO_2$를 포함한 복사 참여 화학종의 복사 열손실을 고려하기 위하여 optically thin model(OTM)이 적용되었다. 주요 결과로서, 공기류에 첨가된 $CO_2$의 소화농도 예측결과는 문헌에 보고된 실험결과를 적절하게 예측하고 있으나, 연료류에 첨가된 경우 다소 과소 예측된 결과를 확인하였다. 소화효과에 대한 정량적 분석을 위하여 가상의 소화약제의 개념이 도입되었다. $CO_2$ 소화효과의 분석을 통해 총괄신장율($a_g$)에 따른 순수 희석효과, 복사 열손실 및 열용량에 의한 열적효과 그리고 $CO_2$의 연쇄반응 억제를 통한 화학적 효과의 정량적 기여도를 구체적으로 확인할 수 있었다.

증기 개질기의 반응 및 열변형 특성에 미치는 공정가스와 버너가스 온도의 영향 (Effect of Process Gas and Burner Gas Temperature on Reaction and Thermal Deformation Characteristics in a Steam Reformer)

  • 한준희;김지윤;이정희;이성혁
    • 한국산학기술학회논문지
    • /
    • 제17권9호
    • /
    • pp.126-132
    • /
    • 2016
  • 본 연구는 전산유체역학 기법을 이용하여 수소 생산 플랜트의 개질 튜브 공정가스와 버너 가스 온도에 따른 화학반응과 열변형 특성을 분석한다. 개질로 내부의 온도는 약 800 K 내지 1000 K 이상으로 고온으로 유지되기 때문에 튜브의 열변형 문제가 심각하게 발생할 수 있다. 따라서 개질로의 구조건전성을 평가하고 안정된 생산력을 가진 장비를 운영하기 위해서 반응과 열변형 특성에 대한 이해는 필수적이다. 본 연구는 상용 전산해석 코드(ANSYS Fluent/Mechanical V.13.0)를 사용하여, 대류, 전도 및 복사 열전달을 포함한 복합 열전달과 난류유동을 3차원적으로 해석하였다. 특히, 열유동 특성에 따른 연성해석(Fluid-Solid Interaction: FSI)를 수행하였으며 고온 버너가스와 공정가스 운전조건에 따른 반응 특성과 열변형 변화를 분석하였다. 수치해석 결과, 개질 공정가스와 버너 가스의 주입온도가 각각 200 K 감소하면, 수소생성량은 최대 약 4 배, 최소 약 2 배 감소한다. 또한, 공정가스와 버너 가스의 주입온도에 따라 열변형은 최대 약 20%, 최소 약 15% 감소한다.

석유 부산물의 물리화학적 분석을 통한 화재폭발 특성연구 (A Study on Fire Explosion Characteristics via Physico-chemical Analysis of Petroleum Residues)

  • 김형기;이영석
    • 공업화학
    • /
    • 제30권5호
    • /
    • pp.556-561
    • /
    • 2019
  • 본 연구에서는 석유 부산물인 열분해잔사유의 화재, 폭발특성을 파악하기 위하여 그 물리 화학적 분석을 실시하고 주요 성분을 선정하였다. GC-SIMDIS 및 MALDI-TOF 분석을 통해 열분해잔사유의 주요 성분 분포영역을 확인하였으며, GC-MS 분석을 통해 주요 성분 분포영역에 대한 정성분석을 실시하였다. 아울러 EA, SARA, TGA 등 다양한 분석결과를 바탕으로 열분해잔사유의 주요 성분을 선정하였다. 그 결과 benzene, toluene, xylene을 주요 성분을 선정하여 PHAST 분석을 통한 화재 폭발 시 최대 피해영향범위를 고찰하였다. Toluene은 제트 화재 발생 시 $227kW/m^2$의 복사열 및 118 m의 영향범위를 나타내어 가장 높은 위험성을 보였으며, xylene과 benzene은 각각 114와 $151kW/m^2$의 최대 복사열 수치를 나타내었다, 또한, pasquill 안정도 및 풍속에 따른 피해영향범위를 분석한 결과 benzene에서 풍속에 따라 최대 55% 이상의 복사열이 증가함을 확인하였으며, 이는 영향범위를 증가시키는 주요인자인 것으로 여겨졌다.

방사선검사의 의무기록에 관한 요구도 분석 (Analysis of the Necessity of Medical Records Related to Radiological Examination)

  • 홍동희;임청환;임우택;주영철;정홍량;김은혜;윤용수;정영진;최지원;정성훈;박명환;양오남;정봉재
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.513-523
    • /
    • 2021
  • The purpose of this study was to discuss the required items and feasibility of medical records of radiological examinations performed by radiological technologists at medical institutions. An online survey was conducted to a total of 10,000 radiation-related workers, of which 1,026 (10.3%) responded. As a research method, self-made questionnaires were used. The online survey was conducted from September 10 to September 20, 2021 for the survey period. For response data, a Chi-square test was performed according to demographic characteristics using SPSS 27.0 version (IBM Inc., Chicago, Ill, USA), and it was judged to be significant when the P value was less than 0.05. The reliability of the questionnaire response was found to be Chronbach α=0.933. More than 90% of the medical records related to radiological examinations are necessary, and they answered that a curriculum, remuneration curriculum, and legal system for medical records should be prepared. More than 90% of the respondents agreed with the proposal of the Radiological Technologist Independent Act for legal preparation, and most of the information required for medical records is currently recorded in DICOM images. According to the demographic characteristics, the medical record requirement for radiological examination, curriculum, continuing education, and legislation were found to be higher with higher education and higher with longer working experience. In addition, most of the radiology departments showed a high demand for medical records, so most of them responded positively to the medical records requirements for radiological examinations. This study analyzed the medical record requirements for radiological examinations, and as shown in the results, medical record requirements for radiological examinations was found that most radiological technologists felt need for the new law and supported it. In addition, if the information recorded in the DICOM image is used, it is considered that medical records could be easily prepared without additional work by the radiological technologists.

흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구 (A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination)

  • 김영근;양숙;왕태욱;김은혜
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권2호
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

방사분석과 분광학을 이용한 Am(III) 가수분해와 옥살레이트 착물 화학종 연구 (Radioanalytical and Spectroscopic Characterizations of Hydroxo- and Oxalato-Am(III) Complexes)

  • 김희경;조혜륜;정의창;차완식
    • 방사성폐기물학회지
    • /
    • 제16권4호
    • /
    • pp.397-410
    • /
    • 2018
  • 아메리슘(Am)은 사용후핵연료의 장기 방사성 독성에 크게 영향을 주기 때문에 고준위 방사성 폐기물 처분의 장기 안전성 평가에 필수적으로 고려되어야 할 원소이다. 분광학적 방법을 이용한 일부 악티나이드 원소의 화학반응 연구가 활발히 진행되고 있는 반면, 아메리슘에 대한 연구는 아직까지 미비한 상황이다. 이 연구에서는 고순도의 시료를 필요로 하는 화학반응 연구를 위하여 $^{241}Am$ 시료를 정제한 후, 액체섬광계수기와 감마선 및 알파선 스펙트럼을 이용하여 정량과 정성분석을 하였다. 액체 광도파 모세관 셀을 이용한 고감도의 UV-Vis 흡수 분광학과 시간분해 레이저 형광 분광학을 이용하여 Am(III) 가수분해물과 옥살레이트(oxalate, Ox) 착물반응을 조사하였다. 산성조건에서 $Am^{3+}$은 503 nm에서 최대 흡수봉우리를 보이며, 몰흡광계수는 $424{\pm}8cm^{-1}{\cdot}M^{-1}$임을 확인하였다. 중성 이상의 pH 조건에서 형성되는 $Am(OH)_3(s)$ 콜로이드 입자에서는 506-507 nm 파장에서 최대 흡수봉우리가 관측되었다. ${Am(Ox)_3}^{3-}$ 착물은 $Am^{3+}$에 비교하여 흡수 및 발광스펙트럼이 각각 4와 5 nm정도 장파장으로 이동하였고 몰흡광계수와 발광세기도 크게 증가하였다. ${Am(Ox)_3}^{3-}$의 발광수명은 23에서 56ns으로 증가하였고 이는 Am(III)의 내부권에 결합하고 있던 약 여섯 개의 물분자가 옥살레이트의 카르복실기로 치환되었음을 의미한다. 이 결과로부터 ${Am(Ox)_3}^{3-}$은 각 옥살레이트 리간드가 두 자리 결합(bidentate)을 하고 있다는 것을 제안하였다.

다기능 보조기구와 체중부하검사 보조기구의 X선 화질 비교 (Comparison of X-ray Image Quality Between Multi-Function Device(MFD) and Weight Bearing Platforms(WBPs))

  • 길종원;이광성
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.605-611
    • /
    • 2019
  • 본 연구의 목적은 여러 가지 하지입식검사에 적용할 수 있는 Multi-Function Device(MFD)를 제작하여 기존에 사용하던 Weight Bearing Platforms(WBPs)들과 X 선 영상의 비교를 통해 임상 활용을 제안하고자 한다. MFD는 단상(보조기구)를 이용한 Weight Bearing Foot/Ankle, Hindfoot Alignment View 검사시 X선 장치의 X선 관구의 최하 조절 높이를 고려하여 제작하였다. 그리고 Foot/Ankle Phantom으로 MFD와 WBPs에서 Weight Bearing Lateral Foot과 Hindfoot Alignment View를 검사하여 X선 영상의 해상력을 Quick MTF(modulation transfer function)프로그램으로 비교하였다. 연구결과 MFD와 WBPs에서 검사한 두 가지 영상 모두 MTF 50(50% Contrast Spatial Frequency)과 10-90%(10-90% of Maximum Energy Rise Distance) Rise의 C/P(Cycles Per Pixel)평균과 LPH(Lines Per Image Height)평균 모두 유의한 차이는 없었다(p>0.05). 연구에서 제작한 MFD는 환자의 안전과 여러 가지 검사를 복합적으로 수행 할 수 있는 유용한 보조기구로 임상 활용을 제안한다. 또한 정책적으로 보조기구의 활용을 권장한다면 전문 업체의 활성화를 돕는 길이며 의료의 질도 더욱 향상할 수 있을 것이다.

한국의 방사성혼합폐기물 관리기준 제안 (A Proposal for the Management Standards of Radioactive Mixed Waste in Korea)

  • 이병관;김창락;이선기;김헌;성석현;박해수;공창식
    • 시스템엔지니어링학술지
    • /
    • 제17권1호
    • /
    • pp.85-96
    • /
    • 2021
  • Radioactive mixed waste (RMW) means waste mixed with radioactive substances and hazardous substances. In Korea, there are definitions and disposal restrictions on RMW in the Nuclear Safety Management Act, but it is difficult to apply because the contents are insufficient, so this paper proposed applicable management standards. The main RMW generated from nuclear power plants is waste oil, waste asbestos, PCB, and waste fluorescent liquid, and their radiation characteristics are mostly at very low levels and some are estimated at low levels. In addition to nuclear power plants, RMW also occurs in research institutes, industries, and hospitals. The acceptance criteria of all disposal facilities in the world basically prohibit disposal of RMW unless the hazardous substances of RMW are removed or mitigated below the standard value. Cases in Korea, the United States, Japan and Europe were reviewed to propose the RMW management standards in Korea. With reference to the results of the above review, this paper clearly defined RMW and proposed detailed management standards for the separation, storage, treatment and disposal of hazardous substances by applying the Waste Control Act. It also mentioned legislation of management standards, regulatory methods, and acceptance criteria of disposal facility operator.

전자빔 조사를 이용한 Polyvinylidene Fluoride의 제조 및 특성 (Preparation and Characterization of Polyvinylidene Fluoride by Irradiating Electron Beam)

  • 최용진;김민
    • 공업화학
    • /
    • 제22권4호
    • /
    • pp.353-357
    • /
    • 2011
  • Polyvinylidene fluoride (PVDF)에 친수성기를 도입하기 위하여, pristine PVDF에 공기 및 수증기 분위기에서 전자빔으로 조사하였고 그에 따른 화학적 조성변화, 구조적 변화 및 표면성질을 관찰하였다. 이때 조사량을 0에서 125 K Gray의 선량으로 조사를 하였으며 그에 따른 PVDF의 구조 및 화학적 조성변화 FT-IR, EDS 및 DSC를 통하여, 표면거동은 접촉각의 측정을 통하여 평가되었다. FT-IR에서는 하이드록실기의 도입이 확인되었다. EDS에서는 선량의 증가에도 불구하고 F (불소) mole조성비는 변화가 없이 약 33%로 일정함을 나타냄으로써 하이드록실기의 도입이 탈불소화반응이 아닌 탈수소화반응 경로를 통하여 도입됨을 알 수 있었다. DSC연구에 있어서는 $T_g$ (유리전이온도)가 전자빔의 선량의 증가에 따라 증가함을 보였고 이는 또한 $-CH_2-$의 H의 탈리 경로를 통한 하이드록실기 도입을 재확인 하였다. $T_m$ (녹는점)의 변화에서도 전자빔 선량의 증가는 녹는점의 상승을 초래하였고 이는 전자빔 선량의 증가가 하이드록실기의 도입과 더불어 수소결합력의 증가를 유발한 효과로 추론할 수 있었다. 마지막으로 다양한 선량조건에서 제조된 PVDF로 필름을 형성한 후 접촉각을 측정한 결과 조사되지 않은 PVDF 필름은 $62^{\circ}$를 나타내었고 125 K Gray PVDF로 제조한 필름은 최저 $13^{\circ}$까지 떨어져 친수화에 성공하였음을 보여주었다.