• Title/Summary/Keyword: radiation response

Search Result 1,299, Processing Time 0.029 seconds

Dosimetric Characteristics of Flexible Radiochromic Film Based on LiPCDA

  • Jung, Seongmoon;Cho, Jin Dong;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.179-184
    • /
    • 2021
  • This study aimed to determine the optimal thickness of the active layer and scan mode for a flexible radiochromic film (F-RCF) based on the active lithium salt of pentacosa-10,12-diynoic acid (LiPCDA). F-RCFs of 90, 120, 140, and 170-㎛ thickness were fabricated using LiPCDA. Several pieces of the F-RCFs were exposed to doses ranging from 0 to 3 Gy. Transmission and reflection modes were used to scan the irradiated F-RCFs. Their dose-response curves were obtained using a second-order polynomial equation. Their sensitivity was evaluated for both scanning modes, and the uniformity of the batch was also examined. For both the transmission and reflection modes, the sensitivity increased as the film thickness increased. For the reflection mode, the dose response increased dramatically under 1 Gy. The value of the net optical density varied rapidly as the thickness of the film increased. However, the dose-response curves showed a supralinear-curve relationship at doses greater than 2 Gy. The sensitivity of the reflection scan at doses greater than 2 Gy was higher than that of the reflection scan within 0-2 Gy. The sensitivity steadily decreased with increasing doses, and the sensitivity of the two modes was within 0.1 to 0.2 at 2 Gy and was saturated beyond that. For the transmission scan, the sensitivity was approximately 0.2 at 3 Gy. For the intra-batch test result, the maximum net optical density difference of the intra-batch was 5.5% at 2 Gy and 7.4% at 0.2 Gy in the transmission and reflection scans, respectively. In the low-dose range, film thickness of more than 120-㎛ was proper in the transmission mode. In contrast, the transmission mode showed a better result compared to the reflection mode. Therefore, the proper scan mode should be selected according to the dose range.

New skeletal dose coefficients of the ICRP-110 reference phantoms for idealized external fields to photons and neutrons using dose response functions (DRFs)

  • Bangho Shin;Yumi Lee;Ji Won Choi;Soo Min Lee;Hyun Joon Choi;Yeon Soo Yeom
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.1949-1958
    • /
    • 2023
  • The International Commission on Radiological Protection (ICRP) Publication 116 was released to provide a comprehensive dataset of the dose coefficients (DCs) for external exposures produced with the adult reference voxel phantoms of ICRP Publication 110. Although an advanced skeletal dosimetry method for photons and neutrons using fluence-to-dose response functions (DRFs) was introduced in ICRP Publication 116, the ICRP-116 skeletal DCs were calculated by using the simple method conventionally used (i.e., doses to red bone marrow and endosteum approximated by doses to spongiosa and/or medullary cavities). In the present study, the photon and neutron DRFs were used to produce skeletal DCs of the ICRP-110 reference phantoms, which were then compared with the ICRP-116 DCs. For photons, there were significant differences by up to ~2.8 times especially at energies <0.3 MeV. For neutrons, the differences were generally small over the entire energy region (mostly <20%). The general impact of the DRF-based skeletal DCs on the effective dose calculations was negligibly small, supporting the validity of the ICRP-116 effective DCs despite their skeletal DCs derived from the simple method. Meanwhile, we believe that the DRF-based skeletal DCs could be beneficial in better estimates of skeletal doses of individuals for risk assessments.

Microwave Radiation-Assisted Chitin Deacetylation: Optimization by Response Surface Methodology (RSM)

  • Iqmal Tahir;Karna Wijaya;Mudasir;Dita Krismayanti;Aldino Javier Saviola;Roswanira Abdul Wahab;Amalia Kurnia Amin;Wahyu Dita Saputri;Remi Ayu Pratika
    • Korean Journal of Materials Research
    • /
    • v.34 no.2
    • /
    • pp.85-94
    • /
    • 2024
  • The optimization of deacetylation process parameters for producing chitosan from isolated chitin shrimp shell waste was investigated using response surface methodology with central composite design (RSM-CCD). Three independent variables viz, NaOH concentration (X1), radiation power (X2), and reaction time (X3) were examined to determine their respective effects on the degree of deacetylation (DD). The DD of chitosan was also calculated using the baseline approach of the Fourier Transform Infrared (FTIR) spectra of the yields. RSM-CCD analysis showed that the optimal chitosan DD value of 96.45 % was obtained at an optimized condition of 63.41 % (w/v) NaOH concentration, 227.28 W radiation power, and 3.34 min deacetylation reaction. The DD was strongly controlled by NaOH concentration, irradiation power, and reaction duration. The coefficients of correlation were 0.257, 0.680, and 0.390, respectively. Because the procedure used microwave radiation absorption, radiation power had a substantial correlation of 0.600~0.800 compared to the two low variables, which were 0.200~0.400. This independently predicted robust quadratic model interaction has been validated for predicting the DD of chitin.

A study of detector size effect using Monte Carlo simulation

  • Park, Kwang-Yl;Yi, Byong-Yong;Vahc, Young W.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.36-38
    • /
    • 2004
  • The detector size effect due to the spatial response of defectors is one critical source of inaccuracy in clinical dosimetry and has been a subject of numerous studies. Conventionally, the detector response kernel contains all of the influence that the detector size has on the measured beam profile. Various analytic models for this kernel have been proposed and studied in theoretical and experimental works. Here, we use a method to determine detector response kernel simply by using Monte Carlo simulation and convolution theory. Based on this numerical method and DOSIMETER, an EGS4 Monte Carlo code, the detector response for a Farmer type ion chamber embedded in water phantom is obtained. There exists characteristic difference in the simulated chamber readings between one with carbon graphite wall and the other with Acrylic wail. Using the obtained response and the convolution theory, we are planning to derive the detector response kernel numerically and remove detector size effect from measurements for 6MV, 10${\times}$l0cm2 and 0.5${\times}$10 cm2 photon beam.

  • PDF

Development and Evaluation of a Mobile Environmental Radiation Measurement System That Can Switch between Low and High Dose Measurement Sections (저선량과 고선량 측정구간 변환이 가능한 모바일 방사선 측정시스템 개발 및 평가)

  • Lee, Hong-Yeon;Han, Sang-Jun;Kim, Bo-Gil;Lee, Geon-Ju;Kim, Seok-Hyeon;Kim, Jeong-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.49-55
    • /
    • 2022
  • This study is to develop a mobile type environmental radiation measurement system for emergency response or environmental radiation monitoring of local governments near nuclear facilities. A mobile radiation measurement system can monitor radiation by field beyond the spatial constraints of a fixed environmental radiation monitor. If installed in local government infrastructure such as public transportation, environmental radiation can be monitored without additional manpower and measurement work. In addition, it is designed to enable monitoring and measurement of radiation from low to high doses as well as the environment in preparation for radioactive disasters such as nuclear power plant accidents. It is expected that this system will be utilized not only in normal times but also in the event of a radiation accident to improve the disaster prevention capabilities of local governments.

Epidemiology of Low-Dose Ionizing Radiation Exposure and Health Effects (저선량 방사선 노출과 건강 영향에 대한 역학적 고찰)

  • Won Jin Lee
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • Low-dose radiation exposure has received considerable attention because it reflects the general public's type and level of exposure. Still, controversy remains due to the relatively unclear results and uncertainty in risk estimation compared to high-dose radiation. However, recent epidemiological studies report direct evidence of health effects for various types of low-dose radiation exposure. In particular, international nuclear workers' studies, CT exposure studies, and children's cancer studies on natural radiation showed significantly increased cancer risk among the study populations despite their low-dose radiation exposure. These studies showed similar results even when the cumulative radiation dose was limited to an exposure group of less than 100 mGy, demonstrating that the observed excess risk was not affected by high exposure. A linear dose-response relationship between radiation exposure and cancer incidence has been observed, even at the low-dose interval. These recent epidemiological studies include relatively large populations, and findings are broadly consistent with previous studies on Japanese atomic bomb survivors. However, the health effects of low-dose radiation are assumed to be small compared to the risks that may arise from other lifestyle factors; therefore, the benefits of radiation use should be considered at the individual level through a balanced interpretation. Further low-dose radiation studies are essential to accurately determining the benefits and risks of radiation.

Temperature variation in steel beams subjected to thermal loads

  • Abid, Sallal R.
    • Steel and Composite Structures
    • /
    • v.34 no.6
    • /
    • pp.819-835
    • /
    • 2020
  • The effects of atmospheric thermal loads on the response of structural elements that are exposed to open environments have been recognized by research works and design specifications. The main source of atmospheric heat is solar radiation, which dominates the variation of the temperature of air, earth surface and all exposed objects. The temperature distribution along the depth of steel members may differ with the geometry configuration, which means that the different-configuration steel members may suffer different thermally induced strains and stresses. In this research, an experimental steel beam was instrumented with many thermocouples in addition to other sensors. Surface temperatures, air temperature, solar radiation and wind speed measurements were recorded continuously for 21 summer days. Based on a finite element thermal analysis, which was verified using the experimental records, several parametric studies were directed to investigate the effect of the geometrical parameters of AISC standard steel sections on their thermal response. The results showed that the overall size of the beam, its depth and the thickness of its elements are of significant effect on vertical temperature distributions and temperature differences.

Results of Three-Dimensional Conformal Radiation Therapy for the Treatment of a Solitary Sternal Relapse of Breast Cancer (흉골에 단독 전이된 유방암의 삼차원 입체조형 방사선 치료 성적)

  • Kim, Hae-Young;Huh, Seung-Jae;Park, Won;Choi, Do-Ho;Kang, Min-Kyu;Yang, Jung-Hyun;Nam, Seok-Jin;Im, Young-Hyuck
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.91-95
    • /
    • 2008
  • Purpose: To evaluate the response and survival rate after three-dimensional conformal radiation therapy(3D-CRT) of patients with a solitary sternal relapse of breast cancer. Materials and Methods: Seventeen patients between May 1996 and June 2005 were evaluated with the salvage 3D-CRT treatment of a solitary sternal relapse of breast cancer. The treatment fields included the gross tumor volume with 2 cm margins. The total radiation dose was $35.0{\sim}61.5$ Gy(biologic effective dose of $43.7{\sim}76.9Gy_{10}$ using an $\alpha/\beta$ ratio of 10 Gy), with a daily dose of $1.8{\sim}3.0$ Gy. The tumor response was evaluated by the change in maximum tumor size via follow up CT scans $1{\sim}3$ months after the completion of treatment. Results: An objective tumor response was achieved in all patients, with a complete response in 5 patients and a partial response in 12 patients. The 5-year overall survival rate was 51.9%(median survival time: 27 months), and the most important factor affecting overall survival was the disease-free interval(interval from primary surgery of breast cancer to the development of sternal metastasis): The 5-year overall survival rate was 61.8% for patients with a disease-free interval ${\geq}12$ months and 0.0% for patients with disease-free interval <12 months(p=0.03). Conclusion: The response to 3D-CRT was good in patients with solitary sternal relapse of breast cancer. Particularly, patients with long disease-free interval from primary surgery survived significantly longer than patients with short disease-free interval from primary surgery.

Gaussian process approach for dose mapping in radiation fields

  • Khuwaileh, Bassam A.;Metwally, Walid A.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1807-1816
    • /
    • 2020
  • In this work, a Gaussian Process (Kriging) approach is proposed to provide efficient dose mapping for complex radiation fields using limited number of responses. Given a few response measurements (or simulation data points), the proposed approach can help the analyst in completing a map of the radiation dose field with a 95% confidence interval, efficiently. Two case studies are used to validate the proposed approach. The First case study is based on experimental dose measurements to build the dose map in a radiation field induced by a D-D neutron generator. The second, is a simulation case study where the proposed approach is used to mimic Monte Carlo dose predictions in the radiation field using a limited number of MCNP simulations. Given the low computational cost of constructing Gaussian Process (GP) models, results indicate that the GP model can reasonably map the dose in the radiation field given a limited number of data measurements. Both case studies are performed on the nuclear engineering radiation laboratories at the University of Sharjah.

An Experimental Study on The Effect of Hyperthermia on Radiation Therapy of Mammary Carcinoma of Rat (백서에서 발생시킨 유방암의 방사선 치료시 온열요법이 미치는 영향에 관한 실험적 연구)

  • Park, Charn-Il;Huh, Seung-Jae;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.167-171
    • /
    • 1984
  • The renewed interest in the use of hyperthermia in cancer therapy is based on radiobiological and clinical evidence indicating that there may be significant thereapeutic advantages with the use of hyperthermia alone or combined with irradiation plus heat. Authors performed the experiment using the chemically induced mammary carcinoma of rats to observe the difference in temperature changes between tumor and normal tissue during heat, and to compare the response of the tumors to radiation alone and to radiation plus hyperthermia. The results were as follows 1. Temperature of tumors was significantly higher than in the normal tissue during heating and the difference was about $1.5^{\circ}C$. 2. $TCD_{50}$ in radiation alone and hyperthermia immediately following radiation was 1,282 rad and 795 rad, respectively and TER value was 1.81.

  • PDF