• Title/Summary/Keyword: radiation patterns

Search Result 760, Processing Time 0.027 seconds

Effect of Antenna Aperture Field on Co-channel Interference, Capacity, and Payload Mass in High Altitude Platform Communications

  • Thornton, John;Grace, David
    • ETRI Journal
    • /
    • v.26 no.5
    • /
    • pp.467-474
    • /
    • 2004
  • In a High Altitude Platform (HAP) cellular communications network, each cell may be served by a dedicated spot-beam antenna. The antennas' beam properties and their spatial overlap control the co-channel interference. In prior literature, radiation patterns have been approximated by a main lobe followed by a constant sidelobe floor. A network of 121 cells has been studied and the method is here extended to the use of more realistic radiation patterns based on the theoretical aperture antenna patterns. This allows for the comparison of the effect of different aperture field tapers, which lead to reduced sidelobe levels and hence higher system capacity but also a more massive antenna payload.

  • PDF

Prognostic factors, failure patterns and survival analysis in patients with resectable oral squamous cell carcinoma of the tongue

  • Sharma, Kanika;Ahlawat, Parveen;Gairola, Munish;Tandon, Sarthak;Sachdeva, Nishtha;Sharief, Muhammed Ismail
    • Radiation Oncology Journal
    • /
    • v.37 no.2
    • /
    • pp.73-81
    • /
    • 2019
  • Purpose: There is sparse literature on treatment outcomes research on resectable oral tongue squamous cell carcinoma (OTSCC). The aim of this study was to measure the treatment outcomes, explore the failure patterns, and identify the potential clinicopathological prognostic factors affecting treatment outcomes for resectable OTSCC. Materials and Methods: It is a retrospective analysis of 202 patients with resectable OTSCC who underwent upfront primary surgical resection followed by adjuvant radiotherapy with or without concurrent chemotherapy if indicated. Results: The median follow-up was 35.2 months (range, 1.2 to 99.9 months). The median duration of locoregional control (LRC) was 84.9 months (95% confidence interval, 67.3-102.4). The 3- and 5-year LRC rate was 68.5% and 58.3%, respectively. Multivariate analysis showed that increasing pT stage, increasing pN stage, and the presence of extracapsular extension (ECE) were significantly associated with poorer LRC. The median duration of overall survival (OS) was not reached at the time of analysis. The 3- and 5-year OS rate was 70.5% and 66.6%, respectively. Multivariate analysis showed that increasing pT stage and the presence of ECE were significantly associated with a poorer OS. Conclusion: Locoregional failure remains the main cause of treatment failure in resectable OTSCC. There is scope to further improve prognosis considering modest LRC and OS. Pathological T-stage, N-stage, and ECE are strong prognostic factors. Further research is required to confirm whether adjuvant therapy adds to treatment outcomes in cases with lymphovascular invasion, perineural invasion, and depth of invasion, and help clinicians tailoring adjuvant therapy.

Insufficiency fracture after radiation therapy

  • Oh, Dongryul;Huh, Seung Jae
    • Radiation Oncology Journal
    • /
    • v.32 no.4
    • /
    • pp.213-220
    • /
    • 2014
  • Insufficiency fracture occurs when normal or physiological stress applied to weakened bone with demineralization and decreased elastic resistance. Recently, many studies reported the development of IF after radiation therapy (RT) in gynecological cancer, prostate cancer, anal cancer and rectal cancer. The RT-induced insufficiency fracture is a common complication during the follow-up using modern imaging studies. The clinical suspicion and knowledge the characteristic imaging patterns of insufficiency fracture is essential to differentiate it from metastatic bone lesions, because it sometimes cause severe pain, and it may be confused with bone metastasis.

Suggestion of Optimal Radiation Fields in Rectal Cancer Patients after Surgical Resection for the Development of the Patterns of Care Study (Patterns of Care 연구 개발을 위한 직장암의 수술 후 방사선치료 시 적정 방사선치료 조사영역 제안)

  • Kim, Jong-Hoon;Park, Jin-Hong;Kim, Dae-Yong;Kim, Woo-Cheol;Seong, JinSil;Ahn, Yong-Chan;Ryu, Mi-Ryeong;Chun, Mison;Hong, Seong-Eon;Oh, Do-Hoon;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.183-191
    • /
    • 2003
  • Purpose: To suggest the optimal radiation fields after a surgical resection based on a nationwide survey on the principles of radiotherapy for rectal cancer in the Korean Patterns on Care Study. Materials and method: A consensus committee, composed of radiation oncologists from 18 hospitals in Seoul Metropolitan area, developed a survey format to analyze radiation oncologist's treatment principles for rectal cancer after a surgical resection. The survey format included 19 questions on the principles of defining field margins, and was sent to the radiation oncologists in charge of gastrointestinal malignancies in all korean hospitals (48 hospitals). Thirty three ($69\%$) oncologists replied. On the basis of the replies and literature review, the committee developed guidelines for the optimal radiation fields nor rectal cancer Results: The following guidelines were developed: superior border between the lower tip on the L5 vertebral body and upper sacroiliac joint; inferior border $2\~3$ cm distal to the anastomosis in patient whose sphincter was saved, and $2\~3$ cm distal to the perineal scar In patients whose anal sphincter was sacrificed; anterior margin at the posterior lip of the symphysis pubis or $2\~3$ cm anterior to the vertebral body, to include the internal iliac lymph node and posterior margin $1.5\~2$ cm posterior to the anterior surface of the surface, to include the presacral space with enough margin. Comparison with the guidelines, the replies on the superior margin coincided in 23 cases ($70\%$), the inferior margin after sphincter saving surgery in 13 ($39\%$), the inferior margin after adbominoperineal resection in 32 ($97\%$), the lateral margin in 32 ($97\%$), the posterior margins in 32 ($97\%$) and the anterior margin in 16 ($45\%$). Conclusion: These recommendations should be tailored to each patient according to the clinical characteristics such as tumor location, pathological and operative findings, for the optimal treatment. The adequacy of these guidelines should be proved be following the Korean Patterns of Care Study.

Hybrid radiation technique of frequency-domain Rankine source method for prediction of ship motion at forward speed

  • Oh, Seunghoon;Kim, Booki
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.260-277
    • /
    • 2021
  • The appropriate radiation conditions of ship motion problem with advancing speed in frequency domain are investigated from a theoretical and practical point of view. From extensive numerical experiments that have been conducted for evaluation of the relevant radiation conditions, a hybrid radiation technique is proposed in which the Sommerfeld radiation condition and the free surface damping are mixed. Based on the comparison with the results of the translating and pulsating Green function method, the optimal damping factor of the hybrid radiation technique is selected, and the observed limitations of the proposed hybrid radiation technique are discussed, along with its accuracy obtained from the numerical solutions. Comparative studies of the forward-speed seakeeping prediction methods available confirm that the results of applying the hybrid radiation technique are relatively similar to those obtained from the translating and pulsating Green function method. This confirmation is made in comparisons with the results of solely applying either the free surface damping, or the Sommerfeld radiation condition. By applying the proposed hybrid radiation technique, the wave patterns, hydrodynamic coefficients, and motion responses of the Wigley III hull are finally calculated, and compared with those of model tests. It is found that, in comparison with the model test results, the three-dimensional Rankine source method adopting the proposed hybrid radiation technique is more robust in terms of accuracy and numerical stability, as well as in obtaining the forward speed seakeeping solution.

The Analysis and Counter-Measure for Signal Distortion of the Searching Radar Due to Ship Structures (함정 구조물에 의한 탐색 레이다 신호 왜곡 현상 분석 및 대책)

  • Song, Ki-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.7
    • /
    • pp.625-630
    • /
    • 2009
  • In this paper, we introduce the analysis and counter-measure of signal distortion of search radar equipped on the ship. Using ShipEDF program, the search radar's main antenna and ship structures are modeled in the view of electromagnetism. Ray tracing method is used for analysis of the search radar's radiation patterns in free space and ship condition. From analyzed radiation patterns, we can conclude that the search radar's signal distortion is due to radiation pattern distortion. We also analyze the surface current distribution of the mast to propose the counter-measure to reduce electro-magnetic field reflection of mast.

Design and Fabrication of CLYC-Based Rotational Modulation Collimator (RMC) System for Gamma-Ray/Neutron Dual-Particle Imager

  • Kim, Hyun Suk;Lee, Jooyub;Choi, Sanghun;Bang, Young-bong;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.112-119
    • /
    • 2021
  • Background: This work aims to develop a new imaging system based on a pulse shape discrimination-capable Cs2LiYCl6:Ce (CLYC) scintillation detector combined with the rotational modulation collimator (RMC) technique for dual-particle imaging. Materials and Methods: In this study, a CLYC-based RMC system was designed based on Monte Carlo simulations, and a prototype was fabricated. Therein, a rotation control system was developed to rotate the RMC unit precisely, and a graphical user interface-based software was also developed to operate the data acquisition with RMC rotation. The RMC system was developed to allow combining various types of collimator masks and detectors interchangeably, making the imaging system more versatile for various applications and conditions. Results and Discussion: Operational performance of the fabricated system was studied by checking the accuracy and precision of the collimator rotation and obtaining modulation patterns from a gamma-ray source repeatedly. Conclusion: The prototype RMC system showed reliability in its mechanical properties and reproducibility in the acquisition of modulation patterns, and it will be further investigated for its dual-particle imaging capability with various complex radioactive source conditions.

The reasonable timing of the adjuvant radiotherapy in the treatment of uterine carcinosarcoma according to the surgical intent: suggestion based on progression patterns

  • Yu, Jeong Il;Choi, Doo Ho;Huh, Seung Jae;Park, Won;Oh, Dongryul;Bae, Duk Soo
    • Radiation Oncology Journal
    • /
    • v.31 no.2
    • /
    • pp.72-80
    • /
    • 2013
  • Purpose: We designed this study to identify and suggest the reasonable timing of adjuvant radiotherapy in the treatment of uterine carcinosarcoma according to the surgical intent and patterns of progression. Materials and Methods: We retrospectively analyzed a total of 50 carcinosarcoma patients diagnosed between 1995 and 2010. Among these 50 patients, 32 underwent curative surgery and 13 underwent maximal tumor debulking surgery. The remaining five patients underwent biopsy only. Twenty-six patients received chemotherapy, and 15 patients received adjuvant radiotherapy. Results: The median follow-up period was 17.3 months. Curative resection (p < 0.001) and stage (p < 0.001) were statistically significant factors affecting survival. During follow-up, 30 patients showed progression. Among these, eight patients (16.0%) had loco-regional progression only. The patients who had received adjuvant radiotherapy did not show loco-regional progression, and radiotherapy was a significant negative risk factor for loco-regional progression (p = 0.01). The time to loco-regional progression was much earlier for non-curative than curative resection (range, 0.7 to 7.6 months vs. 7.5 to 39.0 months). Conclusion: Adjuvant radiotherapy in the treatment of carcinosarcoma might be related to a low loco-regional progression rate. Radiotherapy should be considered in non-curatively resected patients as soon as possible.

Change in Flavor Patterns of Gamma Irradiated Raw Oyster and Oyster Cooking Drip Determined using an Electric Nose (전자코에 의한 감마선조사 생굴과 굴자숙액의 향기패턴 변화)

  • Han, In-Jun;Park, Jae-Seok;Choi, Jong-Il;Kim, Jae-Hun;Song, Beom-Seok;Yoon, Yo-Han;Byun, Myung-Woo;Chun, Soon-Sil;Lee, Ju-Woon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.3
    • /
    • pp.209-214
    • /
    • 2009
  • This study was conducted to evaluate changes in the flavor patterns of gamma irradiated raw oyster and oyster cooking drip using an electronic nose, which consisted of a GC equipped with a surface acoustic wave sensor. The raw oyster was irradiated with 1, 2, 3, 4 and 5 kGy, while the oyster cooking drip was irradiated with 10 and 50 kGy. In the case of raw oyster, the intensities of peaks at retention times (RT) of 2.1 sand 6.8 s were increased, but the peak at a RT of 9.0 s was decreased depending on irradiation dose. In the case of oyster cooking drip, the intensities of peaks at RT 2.5 sand RT 4.1 s increased linearly, but at the peak at RT 5.1 s decreased as the irradiation dose increased. The total amount of flavor components measured in raw oyster increased, while that of oyster cooking drip decreased in response to irradiation.