• Title/Summary/Keyword: radiation mode

Search Result 481, Processing Time 0.06 seconds

Numerical Analysis of Hydrodynamic Forces on a Floating Body in Two-layer Fluids (밀도가 상이한 두 유체층에서 부유체 동유체력 특성의 수치적 해석)

  • Kim, Mi-Geun;Koo, Weon-Cheol
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.3
    • /
    • pp.369-376
    • /
    • 2010
  • In this study, a radiation and a diffraction problems of a floating body in two-layer fluids were solved by the Numerical Wave Tank(NWT) technique in the frequency domain. In two-layer fluids, two different wave modes exist and the hydrodynamic coefficients can be obtained separately for each mode. The two-domain Boundary Element Method(BEM) in the potential fluid using the whole-domain matrix scheme was used to investigate the characteristics of wave forces, added mass and damping coefficients. The effects of the ratio of density and water depth in the lower domain were also evaluated and compared with given references.

Assessment of supervision monitoring for radiation environment around the typical research reactors in China

  • Li, Sa;Wang, Haipeng;Zhang, Yanxia
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4150-4157
    • /
    • 2021
  • The supervision mode, monitoring basis and monitoring scheme of radiation environment monitoring concerning typical research reactors in China were investigated in this study. Summary and analysis were concluded of the present situation of supervised monitoring of radiation environment, such as monitoring objects, points, frequency and so on, based on the relevant data of monitoring points of four typical research reactors in China. Some experiences and existing problems were analyzed concerning the supervised monitoring of China's research reactors. Tips on topics related to strengthen the monitoring of radiation environment around the research reactors has noted.

Clinical Application Analysis of 3D-CRT Methods Using Tomotherapy (토모테라피를 이용한 3차원 입체 조형 치료의 임상적 적용 분석)

  • Cho, Kang-Chul;Kim, Joo-Ho;Kim, Hun-Kyum;Ahn, Seung-Kwon;Lee, Sang-Kyoo;Yoon, Jong-Won;Cho, Jeong-Hee;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.327-335
    • /
    • 2013
  • This study investigates the case of clinical application for TomoDirect 3D-CRT(TD-3D) and TomoHelical 3D-CRT(TH-3D) with evaluating dose distribution for clinical application in each case. Treatment plans were created for 8 patients who had 3 dimensional conformal radiation therapy using TD-3D and TH-3D mode. Each patients were treated for sarcoma, CSI(craniospinal irradiaion), breast, brain, pancreas, spine metastasis, SVC syndrome and esophagus. DVH(dose volume histogram) and isodose curve were used for comparison of each treatment modality. TD-3D shows better dose distribution over the irradiation field without junction effect because TD-3D was not influenced by target length for sarcoma and CSI case. In breast case, dosimetric results of CTV, the average value of D 99%, D 95% were $49.2{\pm}0.4$ Gy, $49.9{\pm}0.4$ Gy and V 105%, V 110% were 0%, respectively. TH-3D with the dosimetric block decreased dose of normal organ in brain, pancreas, spine metastasis case. SCV syndrome also effectively decreased dose of normal organ by using dose block to the critical organs(spinal cord <38 Gy). TH-3D combined with other treatment modalities was possible to boost irradiation and was total dose was reduced to spinal cord in esophagus case(spinal cord <45 Gy, lung V 20 <20%). 3D-CRT using Tomotherapy could overcomes some dosimetric limitations, when we faced Conventional Linac based CRT and shows clinically proper dose distribution. In conclusion, 3D-CRT using Tomotherapy will be one of the effective 3D-CRT techniques.

An analysis of the lateral first-order mode characteristics for the semiconductor laser diodes (반도체 레이저 다이오드의 횡방향 1차모드의 특성 해석)

  • 김형래;곽계달
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.12
    • /
    • pp.91-100
    • /
    • 1995
  • This paper represents the lateral first-order mode characteristics for the semiconductor laser diodes using a two-dimensional numerical simulator. In order to analyze the lateral first-order mode characteristics, Helmholtz wave equation is solved twice for the lateral fundamental and the first-order mode considering the mode gain, total losses, and the recombination rate due to the stimulated emission radiation for the each mode independantly. Through this procedure, we find that the lateral first-order mode was easily guided as increasing the stripe width for the index-guiding structures, and that the lateral first-order mode seems to be dominated in the distribution of total light intensity when its output power reaches nearly half of that of the lateral fundamental mode. This results may be used to design the device structure which guides only the lateral fundamental mode.

  • PDF

Dose and Image Evaluation of Pediatric Head Image according to CT Scan Mode and kVp Changes (CT Scan Mode와 관전압 변경에 따른 소아 두부 영상의 선량 및 영상평가)

  • Byeong-Je Kim;Dong-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.801-808
    • /
    • 2023
  • In order to minimize radiation exposure and secure diagnostic value images during CT examination of the head of children, the usefulness of volume axial mode is evaluated through comparison and analysis of exposure dose and images of volume axial mode, high pitch mode, and helical mode. Image evaluation and dose evaluation were performed in CT high pitch mode, helical mode, and volume axial mode for infants under the age of 1 according to the voltages of 70, 80, and 100 kVp tubes. The image evaluation was conducted by comparing image quality by setting ROI for each image, calculating SNR and CNR, using ONE-WAY (ANOVA) to evaluated statistical significance, and cross-examining the dose evaluation using DLP values displayed in the Dose Report. When inspected using volume axial mode, DLP values were generally low, and SNR and CNR values differed by ROI and kVp. When volume axial mode evaluated the quality of the image compared to other scan modes, the difference is not uniform. For the reason, certain modes are not considered excellent, but the exposure dose was reduced the most in terms of dose. In addition, the point that the volume axial mode can be examined at its original location, short scanning time and needless of table movement is useful for CT tests for children under 1 year of age with high radiation sensitivity.

Concentric-Circle-Grating Surface Emitting (CCGSE)-DFB Laser with second order grating (Second order grating CCGSE-DFB 레이저 해석)

  • 박해령;김효창;이연호
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.313-316
    • /
    • 2000
  • Concentric-Circle-Grating (CCG) cavity is analyzed by coupled mode theory. In this case concentric grating is acting as both feedback element and output coupler. In our calculations radiation loss terms are included in guided coupled mode equations. The surface-emitted field distribution is obtained in self-consistent manner.

  • PDF

Radiation-Laminar Free Convection in a Square Duct with Specular Reflection by Absorbing-Emitting Medium

  • Byun, Ki-Hong;Im, Moon-Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1346-1354
    • /
    • 2002
  • The purpose of this work is to study the effects of specularly reflecting wall under the combined radiative and laminar free convective heat transfer in an infinite square duct. An absorbing and emitting gray medium is enclosed by the opaque and diffusely emitting walls. The walls may reflect diffusely or specularly. Boussinesq approximation is used for the buoyancy term. The radiative heat transfer is evaluated using the direct discrete ordinates method. The parameters under considerations are Rayleigh number, conduction to radiation parameter, optical thickness, wall emissivity and reflection mode. The differences caused by the reflection mode on the stream line, and temperature distribution and wall heat fluxes are studied. Some differences are observed for the categories mentioned above if the order of the conduction to radiation parameter is less than order of 10$\^$-3/ fer the range of Rayleigh number studied. The differences at the side wall heat flux distributions are observed as long as the medium is optically thin. As the top wall emissivity decreases, the differences between these two modes are increased. As the optical thickness decreases at the fixed wall emissivity, the differences also increase. The difference of the streamlines or the temperature contours is not as distinct as the side wall heat flux distributions. The specular reflection may alter the fluid motion.

Reduction of radiated noise by eigen-property control (구조물의 고유특성 제어를 통한 방사소음 저감)

  • Choi, Sung-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.658-663
    • /
    • 2004
  • The interaction between a vibrating structure and a surrounding acoustic medium determines the acoustic power propagating into the far-field. A straightforward method to reduce the radiated power is to reduce the vibration of the structure. However it is more efficient to control the modes of the structure separately since each vibration mode of the structure has different radiation efficiency. An efficient method to reduce the sound radiation in the low frequency region is proposed by reducing the radiation efficiency of the structure.

  • PDF

An Analysis of the Characteristics of Corrugated Horn for Feeding Beam-waveguide Antenna (빔 웨이브가이드 안테나의 급전을 위한 원뿔형 컬러게이트 혼의 특성 해석)

  • 백경훈;이상설
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.666-671
    • /
    • 1990
  • The characteristics of the corrugated conical horn antenna for the satellite communication earth station operating at C band is analyzed and its radiation patterns is measured. We obtain the characterstic equations for corrugated horn in the condition that the balanced hybrid mode is formed on born aperture and calculate radiation patterns in the Fresnel region from the aperture integral expressions obtained by the equivalence principle. The radiation patterns which are calculated for the frequency of 3.85GHz and 6.18GHz are well agreed with the measured data.

  • PDF

Calculation of Radiation Patterns of Planar Array Antennas of Rectangular Waveguides Loaded by Dielectric Plug and Sheath (유전체 마개와 덮개가 부착된 구형 도파관의 평면 배열 안테나의 복사패턴 계산)

  • 김세윤;하헌태
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.9
    • /
    • pp.8-14
    • /
    • 1992
  • The radiation pattern of a rectangular-grid array antenna consisted of rectangular waveguides is represented by multiplication of its element and array factors. Calculated radiation patterns for excitation of TES110T mode inside the waveguides suffer from the blindness at a particular direction on E-plane. Numerical simulations show that the blindness can be removed by inserting dielectric plug inside the waveguides or covering dielectric sheath in front of the waveguides.

  • PDF