• 제목/요약/키워드: radiation grafting

검색결과 85건 처리시간 0.035초

Functional Outcomes of Multiple Sural Nerve Grafts for Facial Nerve Defects after Tumor-Ablative Surgery

  • Lee, Myung Chul;Kim, Dae Hee;Jeon, Yeo Reum;Rah, Dong Kyun;Lew, Dae Hyun;Choi, Eun Chang;Lee, Won Jai
    • Archives of Plastic Surgery
    • /
    • 제42권4호
    • /
    • pp.461-468
    • /
    • 2015
  • Background Functional restoration of the facial expression is necessary after facial nerve resection to treat head and neck tumors. This study was conducted to evaluate the functional outcomes of patients who underwent facial nerve cable grafting immediately after tumor resection. Methods Patients who underwent cable grafting from April 2007 to August 2011 were reviewed, in which a harvested branch of the sural nerve was grafted onto each facial nerve division. Twelve patients underwent facial nerve cable grafting after radical parotidectomy, total parotidectomy, or schwannoma resection, and the functional facial expression of each patient was evaluated using the Facial Nerve Grading Scale 2.0. The results were analyzed according to patient age, follow-up duration, and the use of postoperative radiation therapy. Results Among the 12 patients who were evaluated, the mean follow-up duration was 21.8 months, the mean age at the time of surgery was 42.8 years, and the mean facial expression score was 14.6 points, indicating moderate dysfunction. Facial expression scores were not influenced by age at the time of surgery, follow-up duration, or the use of postoperative radiation therapy. Conclusions The results of this study indicate that facial nerve cable grafting using the sural nerve can restore facial expression. Although patients were provided with appropriate treatment, the survival rate for salivary gland cancer was poor. We conclude that immediate facial nerve reconstruction is a worthwhile procedure that improves quality of life by allowing the recovery of facial expression, even in patients who are older or may require radiation therapy.

Radiation Grafting of Hydrophilic Monomers onto Polyester

  • Park, Jae-Ho;Lee, Chong-Kwang;Lee, Kwang-Jin
    • Nuclear Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.103-114
    • /
    • 1973
  • 본 실험은 방사선을 이용하여 Polyester 직포의 흡수성과 염색성 그리고 대전성을 증진시키기 위한 연구로서 실온하에서 함침법으로 Acrylic acid또는 4-vinylpyridine을 Polyester 직포에 접목시켰다. Polyester 직포를 25$^{\circ}$또는 7$0^{\circ}C$에서 Acrylic acid나 Acrylic acid와 4-vinylpyridine의 emulsion 용액에 함침시켰으며 함침된 Polyester 직포를 질소깨스 존재 하에서 Co-60의 l-rays로 조사시켰다. Acrylic acid가 접목된 Polyester 직포를 Sodium carbonate, Calcium acetate 또는 Potassium persulfate로 처리하였을 때 흡수율은 더욱 증가하였으며 직포 표면에 형성된 polyacrylic acid 는 0.1% NaoH 용액으로 대부분 추출되었다. 4-vinylpyridine과 Acrylic acid의 혼합용액을 함침용액으로 사용하였을 경우 4-VP/AA의 비율과 방사선 선량이 커짐에 따라 접목율은 점점 증가함을 보여주었다. 여러가지로 처리된 Polyester 직포 표면에 물방울을 떨어 뜨렸을 때의 Contact angle을 측정하여 보니 접목율이 증가함에 따라 대전성은 감소하였다. Acryli acid가 접목된 Polyester 섬유를 Salt로 처리하여 전자 현미경으로 관찰하여 본 결과 일련의 무정형 형태로 결합되어 있었다.

  • PDF

방사선 조사 그라프트중합에 의한 폴리프로필렌 정밀여과막의 친수화 및 물 투과특성 (Hydrophilic Modification of Polypropylene Microfiltration Membrane by Radiation-Induced Graft Polymerization and Water Permeability)

  • 박재형;이근우;황택성;이재원;오원진
    • 공업화학
    • /
    • 제10권6호
    • /
    • pp.954-959
    • /
    • 1999
  • 본 연구에서는 소수특성의 PP 정밀여과막에 방사선을 조사하여 친수성 모노머인 2-hydroxyethyl methacrylate(HEMA), acrylic acid(AAc) 및 methacrylic acid(MAAc)를 그라프트 중합하였다. 3가지 모노머에 대한 그라프트 중합반응에서 물/메탄올 혼합용매의 조성에 따라 그라프트율에 미치는 효과를 조사하였으며, 이에 대한 각 모노머의 농도에 따른 영향을 고찰하였다. 가장 높은 그라프트율을 얻는 용매조건은 AAc는 순수한 물에서, MAAc는 물/메탄올 혼합비가 50/50 vol %에서, 그리고 HEMA는 25/75 vol %이었다. 그라프트된 PP 다공성 분리막의 모노머 도입여부와 표면특성변화는 FTIR-ATR 및 SEM을 이용하여 관찰하였다. 또한 인장강도와 연신율을 측정하여 그라프트율에 따른 막의 기계적 특성을 평가하였다. 그라프트된 PP막은 본래의 PP막보다 물 투과속도가 증가하였으며, 물 투과에 적당한 모노머로 HEMA임을 알았고 99%의 그라프트율에서 가장 좋은 물 투과속도를 보였다. 또한 AAc가 그라프트된 PP막 및 MAAc가 그라프트된 PP막의 물 투과속도는 pH나 $Cu^{2+}$에 의해 크게 좌우되나 HEMA는 pH나 $Cu^{2+}$에 영향이 거의 없었다.

  • PDF

요소(Urea) 및 이온의 선택적 분리를 위한 음이온교환막의 제조 (Preparation of Anion-exchange Membrane for Selective Separation of Urea and Ion)

  • 김병식;김민;허광범;홍주희;나원재;김재훈
    • 공업화학
    • /
    • 제17권3호
    • /
    • pp.303-309
    • /
    • 2006
  • 본 연구에서는 음이온 및 요소의 투과유속이 강화된 복막투석용 기능성 음이온 교환막의 제조와 특성에 관한 연구를 수행하였다. 음이온 교환막은 UV와 방사선 그라프트 중합법에 의하여 제조되었다. UV 그라프트 중합법에 의해 제조된 분리막의 경우 HEMA와 VBTAC의 비율이 1:2일때 가장 높은 그라프트율을 보였으며 그 이상의 농도에서는 호모폴리머의 생성이 많아지면서 그에 의한 자외선 침투의 제약으로 그라프트율이 감소하였다. 광개시제의 경우에는 0.2 wt%인 경우에 가장 높은 그라프트율을 나타내었으며 그 이상의 농도에서는 다소 감소하는 경향을 나타냈다. 방사선 그라프트 중합법에 의해 제조된 분리막의 경우 VBTAC/HEMA막의 경우 6 h 반응시 96%, GMA막의 경우 반응시간 2 h에 100% 이상의 그라프트율을 나타내었다. 또한, 음이온 교환막을 제조하기 위해 그라프트율 113% 막을 사용하였으며, 음이온 교환기로는 DEA, TEA를 사용하였다. DEA막의 경우 반응시간 4 h에서 70%, TEA막의 경우 2 h 반응에서 30%의 전화율을 나타내었다. 또한, 두 방법에 의하여 제조된 음이온 교환막은 양이온은 배제시키고 음이온과 요소만을 투과하는 특성을 나타내었다.

전자선 조사 방법을 통한 생분해성고분자의 표면개질 특성 평가 (Surface Modification of Poly(L-lactide-co-ε-caprolactone) Nanofibers by Electron-beam Irradiation)

  • 김우진;신영민;박종석;권희정;노영창;임윤묵
    • 방사선산업학회지
    • /
    • 제5권4호
    • /
    • pp.365-370
    • /
    • 2011
  • Electrospun nanofibers prepared with synthetic biodegradable polymer have some limitations in regulating adhesion, proliferation, and spreading of cells because of their surface hydrophobicity and absence of cell-interaction. In this study, we functionalized the electrospun poly(L-lactide-co-${\varepsilon}$-caprolactone) (PLCL) nanofibers with acrylic acid (AAc) to modulate their surface hydrophilicity using electron-beam irradiation method and then measured grafting ratio of AAc, water contact angle, and ATR-FTIR of AAc-grafted nanofibers. A grafting ratio of AAc on the nanofibers was increased as irradiation dose and AAc concentration were increased. AAc-grafted nanofibers also have higher wettability than non-modified nanofibers. In conclusion, those surface-modified nanofibers may be an essential candidate to regulate cell attachment in tissue engineering applications.

Radiation-Induced Graft Copolymerization of Acrylic Acid onto Polyester

  • Chang, Hoon-Sean;Kong, Young-Kun;Lee, Chong-Kwang;Park, Jae-Ho
    • Nuclear Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.65-74
    • /
    • 1977
  • High dose rates꼭 전자선을 이용하여 Polyester 직포에 acrylic acid를 중합 반응시켰다. Homopolymerization inhibitor로서 cation 을 첨가시키면 hoinopolymerization 뿐만 아니라 graft효율도 감소되었다. Graft 중합 반응 속도는 선량율이 1.6$\times$$10^{6}$rad/sec에서부터 10$\times$$10^{6}$ rad/sec 사이에서 선량율의 0.82승에 비례하였다. Acrylic acid가 graft 중합 반응된 Polyester 직포는 흡습성, 제전성 효과 등이 크게 증진되었다.

  • PDF

방사선 그라프트 PFA-폴리스티렌 멤브레인으로 제조한 직접 메탄올 연료전지용 MEA의 성능과 특성 (Characterization and Performance of MEA for Direct Methanol Fuel Cell Prepared with PFA Grafted Polystyrene Membranes via Radiation-Grafting Method)

  • 강세구;백동현;김상경;임성엽;정두환;박영철;신준화;강필현;노영창;설용건
    • 전기화학회지
    • /
    • 제12권2호
    • /
    • pp.173-180
    • /
    • 2009
  • DMFC (Direct Methanol Fuel Cell)용의 새로운 고분자 전해질 멤브레인을 개발하기 위하여 스티렌 단량체를 poly(tetrafluoroethylene perfluoropropyl vinyl ether) (PFA) 필름에 그라프트 중합 반응시킨 후에 술폰화 반응을 진행하였다. $\Upsilon$-ray를 이용하여 방사선 그라프트 중합 반응시킨 방사선 그라프트 필름의 술폰화 반응은 chlorosulfonic acid/dichloroethane (5 v/v%) 혼합 용액에서 진행하였다. PFA 그라프트 폴리스티렌 멤브레인 (PFA-g-PSSA)의 화학적, 물리적, 전기화학적 및 형태의 특성은 푸리에 변환 적외선 분광기 (FTIR), 이온전도도 측정기 및 주사전자현미경 (SEM)으로 분석하고 함수율과 메탄올 투과도도 측정하였다. PFA-g-PSSA 멤브레인으로 제작한 MEA의 단위전지 성능을 평가하였고, 전지의 셀 저항은 임피던스 분석 장치를 이용하여 측정하였다. PFA-g-PSSA 멤브레인으로 제조한 MEA는 Nafion 112로 제조한 MEA보다 우수한 DMFC 성능을 나타내었다.

Radiation-Induced Graft Copolymerization of Methacrylic Acid and Methyl methacrylate onto Polyester.

  • Kang, Young-Kun;Chang, Hoon-Seun;Lee, Chong-Kwang;Park, Jae-Ho
    • Nuclear Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.195-201
    • /
    • 1978
  • 감마선을 이용하여 폴리에스터직포에 methacylic acid와 methyl methacylate를 graft 종합반응시켜서 그 반응성을 보았다. 폴리에스터직포에 acrylic acid, methacrylic acid, methyl methacrylate를 중합반응 시켰을 때 graft 효율은 monomer 혼합용액내에 포함되어 있는 용매의 dielectric constant에 따라 상당한 차이를 나타내었다. Graft 수율은 방사선 선량과 monomer 농도 및 swelling agent의 농도에 좌우되었다. MA graft copolymer의 glass transition temperature (101$^{\circ}C$)와 melting point (238$^{\circ}C$)를 측정하였고, 정전기 효과는 frictional electricity 8,000V에서 half life가 0 sec이었으며, moisture regain는 5.6%, wicking time은 1 sec이었다.

  • PDF

Preparation of Modified Hollow Polypropylene Membrane and Their Adsorption Properties of ${\gamma}$-Globulins

  • Hwang, Taek-Sung;Park, Jin-Won
    • Macromolecular Research
    • /
    • 제11권5호
    • /
    • pp.347-351
    • /
    • 2003
  • The hydrophobic ligand-containing hollow polypropylene (PP) membranes were synthesized by the mutual radiation induced graft copolymerization with glycidylmethacrylate (GMA) onto hollow PP membrane followed by the subsequent functionalization with L-phenylalanine. FT-IR, elemental analysis and UV spectroscopy were utilized to characterize copolymer composition, and degree of grafting, functionalization conversion and ${\gamma}$-globulins adsorption. The degree of grafting on the PP surface increased with the reaction time and total dose of E-beam. In the subsquent functionalization, the amount of L-phenylalanine increased with the increase in the degree of grafting and the degree of conversion was about 30%. The ${\gamma}$-globulins adsorption experiments showed that adsorption capacity had a maximum value at pH 8. The ${\gamma}$-globulins adsorption capacity in the basic pH region was higher than in the acidic pH region.