• 제목/요약/키워드: radiation exposure

검색결과 1,972건 처리시간 0.031초

유방X선촬영 시 피폭선량 감소를 위한 유방촬영용 차폐복의 유용성에 관한 연구 (A Study on the Usefulness of Breast Shielding Apron for Reducing Exposure Dose in Mammography)

  • 구본열;김지원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권2호
    • /
    • pp.99-104
    • /
    • 2019
  • Mammography, conducted every two years, causes cancer due to regular exposure to radiation while reducing rate of death caused by breast cancer. The study evaluates the effect of breast shielding apron made to shield off scattered radiation that occurs to the breast when the opposite side breast is mammogramed. AGD was measured using ACR phantom, composed of 50% mammary glands and 50% fat, and radiation was measured before and after wearing the apron on the breast when the opposite side of the breast is mammogramed. When CC direction mammography was conducted to a breast, the AGD was 1.84 mGy. When CC direction and MLO direction mammography were done to a breast, the average dose detected from the opposite side breast from four directions(top to bottom and medial to lateral) was $140{\mu}Gy$ with maximum dose of $256{\mu}Gy$ at medial side. After putting on the apron, the dose, caused by scattered radiation, was not detected from any of the four directions. Using of breast shielding apron is expected to minimize the radiation exposure by blocking scattered radiation to the breast shielded, when mammography is done to the opposite side breast.

뇌혈관 중재적시술에 있어 측방향 차폐체를 이용한 시술자 피폭 선량 저감화 방법 연구 (Reducing Radiation Exposure Dose on Operator by Using Lateral Protection in Neuro-Intervention)

  • 김종덕;안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제8권1호
    • /
    • pp.1-10
    • /
    • 2014
  • 양방향 뇌혈관촬영기는 하나의 선원에서 방사선이 나오는 것이 아니라 정방향과 측방향에서 방사선 피폭이 이루어지기 때문에 방사선 관계종사자의 피폭이 더욱 많아질 수밖에 없다. 따라서 환자가 받는 선량도 중요하겠지만 시술을 시행하고 있는 방사선 관계종사자 역시 피폭선량을 줄일 수 있는 방법에 대해 많은 관심을 보이고 있다. 본 연구의 목적은 양방향 뇌혈관촬영기의 혈관검사 및 중재적방사선시술에 있어 X-선 관구에서 직접 조사되는 1차 방사선, 정방향관구와 측방향 검출기사이에서 발생하는 1차 산란방사선, 상대적으로 적지만 촬영실 벽이나 바닥에서 반사되는 2차 산란방사선 발생을 간과하지 않을 수 없기에 기존의 일반적인 차폐방법인 천정형 차폐, 테이블형 차폐방법에서 보다 더 적극적인 차폐방법인 측방향 차폐체의 방어용구를 설치하여 시술자가 받는 직접방사선 및 산란방사선에 의한 피폭선량을 최대한 줄이고자 노력하였다. 그 결과 투시측정에서는 생식샘 약 3.64배, 갑상샘 약 3.13배, 눈 약 4.42배 정도 더 감소하였고, 디지털 감산 혈관조영측정에서는 생식샘 약 4.98배, 갑상샘 약 3.00배, 눈 약1.67배의 피폭선량 감소효과를 얻어내었다. 결론적으로 양방향 뇌혈관촬영기의 혈관검사 및 중재적방사선시술시 설치하였던 측방향 차폐체의 방어용구는 일반적인 차폐방법보다 시술자의 피폭선량을 감소시키는데 많은 효과를 주었다고 사료된다.

방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가 (Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope)

  • 정재훈;이충운;유연욱;서영덕;최호용;김윤철;김용근;원우재
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.44-49
    • /
    • 2017
  • 목적: 핵의학 검사를 시행한 병동 환자의 시간과 거리에 따른 방사선량률을 측정하여 방사성동위원소 투여를 받은 환자가 병동 간호사에게 미치는 피폭을 예측하고 실제 총 피폭량과 비교하여 보고자 한다. 대상 및 방법: 병동에서 근무하고 있는 간호사 14명을 대상으로 열형광 선량계와 광자극 선량계를 이용하여 방사선 피폭선량을 측정하였고 핵의학 검사를 시행한 환자 50명(PET/CT 20명, Bone scan 20명, Myocardial SPECT 10명)을 대상으로 방사성동위원소 투여 직후와 검사시행 직후에 표면, 50cm, 1m에서 외부 방사선량률을 측정하였다. 측정 결과를 바탕으로 유효반감기를 도출한 후 병동 간호사가 받을 수 있는 피폭량을 예측하였다. 그리고 열형광선량계와 광자극선량계로 측정된 병동 간호사의 실제 총 피폭량과 비교 하였다. 결과: 병동 간호사 14명을 대상으로 한 피폭선량 측정결과 평균값과 최대값은 각각 분기당 0.01 mSv, 0.02 mSv 이었고 핵의학 검사를 시행 받은 환자의 선량률은 표면, 50cm, 1m 거리 순으로 PET/CT는 $376.0{\pm}25.2{\mu}Sv/hr$, $88.1{\pm}8.2{\mu}Sv/hr$, $29.0{\pm}5.8{\mu}Sv/hr$ 이고 Bone scan은 $206.7{\pm}56.6{\mu}Sv/hr$, $23.1{\pm}4.4{\mu}Sv/hr$, $10.1{\pm}1.4{\mu}Sv/hr$이고 Myocardial SPECT는 $22.5{\pm}2.6{\mu}Sv/hr$, $2.4{\pm}0.7{\mu}Sv/hr$, $0.9{\pm}0.2{\mu}Sv/hr$이다. 또한 검사를 시행한 후 측정한 선량률은 표면, 50cm, 1m 거리 순으로 PET/CT는 $165.3{\pm}22.1{\mu}Sv/hr$, $38.7{\pm}5.9{\mu}Sv/hr$, $12.4{\pm}2.5{\mu}Sv/hr$ 이고 Bone scan은 $32.1{\pm}8.7{\mu}Sv/hr$, $6.2{\pm}1.1{\mu}Sv/hr$, $2.8{\pm}0.6{\mu}Sv/hr$이고 Myocardial SPECT는 $14.0{\pm}1.2{\mu}Sv/hr$, $2.1{\pm}0.3{\mu}Sv/hr$, $0.8{\pm}0.2{\mu}Sv/hr$이다. 위의 결과를 바탕으로 유효반감기를 도출한 후 검사종료 30분 후 원자력안전법에서 규정하는 일반인 선량한도까지 도달하는데 걸리는 시간을 반감기를 고려치 않고 보수적으로 계산하면 PET/CT는 표면, 50cm, 1m 거리 순으로 7.9시간, 34.1시간, 106.8시간이며 Bone scan은 40.4시간, 199.5시간, 451.1시간이고 Myocardial SPECT는 62.5시간, 519.3시간, 1313.6시간이다. 결론: 본 연구 결과에 의하면 병동 간호사는 일반인 선량한도 보다 훨씬 적은 피폭량을 받는 것으로 나타나, 실질적으로 판단할 때 핵의학 검사를 시행한 환자로 인하여 받는 피폭의 영향은 미미한 것으로 판단된다.

  • PDF

한국에서 방사선 관련 종사자들의 개인피폭선량 실태에 관한 연구 (Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea)

  • 임봉식
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.185-195
    • /
    • 2006
  • 목 적: 방사선 관련종사자들의 1995년 1월 6일 "진단용 방사선 발생장치의 안전관리에 관한 규칙"을 제정한 이후 방사선 노출로 인한 개인피폭선량의 실태를 조사 분석하여, 해당 의료기관과 방사선 관련종사자들에게 방사선피폭에 대한 경각심을 고취시키고, 안전관리에 도움을 주고자 한다. 조사대상 및 방법: 2000년 1월 1일부터 2004년 12월 31일까지 5년 동안 전국에 있는 검사기관, 교육기관, 군부대, 병원, 보건소, 산업체, 연구기관, 의원에서 근무하였거나 근무하고 있는 방사선종사자들의 개인 피폭선량 측정결과 판독기관에 등재(登載)된 대상자 57,136명에 대한 분기별 피폭선량 자료 149,205건을 대상으로 하여 판독수행기관에 직접 방문 하거나, 전화를 통하여 책임자에게 연구의 목적을 설명하고 긴밀한 협조를 얻어 수집하였다. 자료를 분석하는데 있어 SPSS ver 12.0을 이용하였으며, 분석방법으로는 연도별 분기별 성별 연령별 직종별 근무부서별 업종별로 심부선량과 표면선량으로 나누어 분석하였다. 빈도분석 one-way ANOVA two-way ANOVA를 시행하였다. 결 과: 5년간의 평균 피폭선량에서 심부선량과 표면선량의 평균값이 해마다 낮아지는 것으로 조사되었고, 성별 평균 피폭선량은 심부선량과 표면선량에서 남자가 여자보다 높게 나타났으며 연령별 평균 피폭선량에서 심부선량과 표면선량은 높은 연령군보다 낮은 연령군에서 높게 나타났고, 직종별 평균 피폭선량은 심부선량과 표면선량 모두에서 방사선사가 가장 높게 나타났으며 근무 부서별 평균 피폭선량은 심부선량과 표면선량에서 핵의학과가 가장 높게 나타났고, 업종별 평균 피폭선량은 심부선량과 표면선량에서 병 의원이 높게 나타난 것으로 조사되었다. 결 론: 이상의 결과에서 볼 때 최근 5년간 전국 지역에 있는 병원 의원 기타 등에서 근무하는 방사선 종사자들의 방사선 평균 피폭선량은 국제방사선방어위원회(ICRP)에서 권고하는 허용선량 기준치(20 mSv/년)를 초과하지 않는 범위의 피폭을 받고 있는 것으로 나타났다. 그러나 그것은 평균적인 수치이지 개인적으로 피폭선량에 있어 그 범위의 피폭을 초과하는 종사자들이 있는 것으로 나타나 상당히 우려가 되고 있는 실정이다. 따라서 방사선 관련종사자들이 각자가 개인별 관리에 더욱더 철저를 기하고 방사선으로 인한 피폭을 최소화 시키는데 있어 체계적인 교육 및 안전 불감증에 대한 지도가 지속적으로 유지되어야 할 것이다.

  • PDF

Level of radiation dose in university hospital non-insured private health screening programs in Korea

  • Lee, Yun-Keun
    • Environmental Analysis Health and Toxicology
    • /
    • 제31권
    • /
    • pp.7.1-7.6
    • /
    • 2016
  • Objectives The aim of this study is to evaluate radiation exposure resulting from the comprehensive health examinations of selected university hospital programs and to present basic data for research and management strategies on the health effects of medical radiation exposure. Methods Radiation-based diagnostic studies of the comprehensive health examination programs of ten university hospitals in Seoul, Korea, as introduced in their websites, were analyzed. The medical radiation studies of the programs were reviewed by radiologists. Only the effective doses of the basic studies were included in the analysis. The optional studies of the programs were excluded. Results Among the 190 comprehensive health examination programs, 132 programs (69.5%) included computed tomography studies, with an average of 1.4 scans. The average effective dose of radiation by program was 3.62 mSv for an intensive program for specific diseases; 11.12 mSv for an intensive program for cancer; 18.14 mSv for a premium program; and 24.08 mSv for an overnight program. A higher cost of a programs was linked to a higher effective dose (r=0.812). The effective doses of the examination programs for the same purposes differed by as much as 2.1 times by hospital. Inclusion of positron emission tomography-computed tomography was the most critical factor in determining the level of effective dose. Conclusions It was found that radiation exposure dose from comprehensive health exam programs targeted for an asymptomatic, healthy public reached between 3.6 and 24 times the annual dose limit for the general public. Relevant management policies at the national level should be provided to minimize medical radiation exposure.

방사선 개인피폭선량계를 이용한 피폭선량 측정 및 유용성 평가 (Evaluation of Usability and Radiation Dose Measurement Using Personal Radiation Exposure Dosimeter)

  • 강인석;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제14권11호
    • /
    • pp.864-870
    • /
    • 2014
  • 선량계 유용성을 평가하기 위한 방법으로 방사선관계종사자의 피폭선량을 측정하여 개인피폭관리를 위한 선량계 선택의 기초 자료를 제시하고자 하였다. 2012년 1년간 방사선사 30명을 대상으로 하였으며 개인피폭 누적선량을 측정하여 열형광선량계, 형광유리선량계, 광자극발광선량계의 성능을 조사하였다. 연구방법으로는 DAP와 ion-chamber를 이용하여 세종류 개인피폭선량계의 선량측정값을 비교 분석하였으며 의료기관별, 검사업무별, 분기별 방사선관계종사자의 피폭누적선량을 확인하였다. 결과적으로 직접 X선조사를 통한 개인피폭선량계의 선량값과 ion-chamber의 절대값에서 광자극발광선량계가 열형광선량계나 형광유리선량계에 비해 더 유사한 선량값을 나타내 측정 능력면에서 더 우수한 결과를 나타냈다. 또한 방사선발생구역에서 방사선관계종사자의 피폭선량이 광자극발광선량계에서 보다 높게 나타났다.

주산기 암컷 백서의 태아에 방사선피폭에 따른 선천성기형 발생 시 셀레늄과 엽산 혼합물의 방사선 방호효과 (Radiation Protective Effect of Selenium and Folic Acid Mixtures in the Development of Congenital Anomalies Following Radiation Exposure to the Fetus of Perinatal Female White Rats)

  • 정도영;최형석;김장오;신지혜;김주희;박경진;민병인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.157-162
    • /
    • 2018
  • This study is a search for radiation protection effects of radiation exposure on the organogenic period during the prenatal period, which is known to be the most likely to have congenital malformations by radiation exposure. To study the radiation protection for the mixture of selenium that is strong antioxidant and folic acid that is essential vitamin for DNA synthesis, 2 Gy of radiation was irradiated to pregnant female rats. then, after 14 days of fetal birth, observing blood components, SOD(Superoxide Dismutase), histological changes and external malformations. There was a significant protective effect to reduce blood cell damage(p<0.05) in the irradiation group after selenium and folic acid mixture were administered than irradiation group, and the activation of SOD which is antioxidant enzymes was increased. In addition, confirmed the effect of suppressing the expression of apoptosis of small intestinal cells and the reduction of cerebral cortex layer reduction by radiation. thus, it was confirmed that the congenital malformations were reduced as a result of these protective effects. Based on these results, selenium and folic acid mixture may reduce the incidence of congenital malformations, and it will reduce the damage of the fetus caused by the exposure of the organogenic period due to accidents.

Occupational radiation exposure control analyses of 14 MeV neutron generator facility: A neutronic assessment for the biological and local shield design

  • Swami, H.L.;Vala, S.;Abhangi, M.;Kumar, Ratnesh;Danani, C.;Kumar, R.;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1784-1791
    • /
    • 2020
  • The 14 MeV neutron generator facility is being developed by the Institute for Plasma Research India to conduct the lab scale experiments related to Indian breeding blanket system for ITER and DEMO. It will also be utilized for material testing, shielding experiments and development of fusion diagnostics. Occupational radiation exposure control is necessary for the all kind of nuclear facilities to get the operational licensing from governing authorities and nuclear regulatory bodies. In the same way, the radiation exposure for the 14 MeV neutron generator facility at the occupational worker area and accessible zones for general workers should be under the permissible limit of AERB India. The generator is designed for the yield of 1012 n/s. The shielding assessment has been made to estimate the radiation dose during the operational time of the neutron generator. The facility has many utilities and constraints like ventilation ducts, accessible doors, accessibility of neutron generator components and to conduct the experiments which make the shielding assessment challenging to provide proper safety for occupational workers and the general public. The neutron and gamma dose rates have been estimated using the MCNP radiation transport code and ENDF -VII nuclear data libraries. The ICRP-74 fluence to dose conversion coefficients has been used for the assessment. The annual radiation exposure has been assessed by considering 500 h per year operational time. The provision of local shield near to neutron generator has been also evaluated to reduce the annual radiation doses. The comprehensive results of radiation shielding capability of neutron generator building and local shield design have been presented in the paper along with detailed maps of radiation field.

CLARIFYING THE PARADIGM ON RADIATION EFFECTS & SAFETY MANAGEMENT: UNSCEAR REPORT ON ATTRIBUTION OF EFFECTS AND INFERENCE OF RISKS

  • Gonzalez, Abel J.
    • Nuclear Engineering and Technology
    • /
    • 제46권4호
    • /
    • pp.467-474
    • /
    • 2014
  • The aim of this paper is to describe a relatively recent international agreement on the widely debated concepts of: (i) attributing effects to low dose radiation exposure situations that have occurred in the past and, (ii) inferring radiation risk to situations that are planned to occur in the future. An important global consensus has been recently achieved on these fundamental issues at the level of the highest international intergovernmental body: the General Assembly of the United Nations. The General Assembly has welcomed with appreciation a scientific report on attributing health effects to radiation exposure and inferring risks that had been prepared the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) following a formal request by the General Assembly.

방사선 피폭선량에 대한 생체 조직의 임피던스 변화 (Impedance Changes of Living Tissue During Radiation Exposure Dose)

  • 길상형;이무석;남지호;이영화;김군도;이종규
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.202-207
    • /
    • 2013
  • 생체 조직의 전기 신호는 살아 있는 조직과 관련된 많은 정보를 포함하고 있으며, 생체 조직에 생물학적 변화가 있으면 고유의 전기적 특성이 변화한다. Impedance/Gain-phase analyzer로 1 KHz에서 1 KHz까지 주파수 대역을 설정한 다음 교류 주파수를 인가하며 돼지안심 조직의 임피던스 특성을 방사선 피폭선량에 따라 변화가 있는지 알아보고자 하였다. 임피던스 크기는 주파수에 비례하여 감소하였으며, 상관계수(r)가 -0.96으로 높은 음의 상관관계를 보였다. 위상차 변화는 거의 없었으며 조직은 저항성을 나타내었다. 측정값은 변동계수가 ${\pm}5$%이내로 재현성이 있음을 알 수 있었고, 측정 시간 경과에 따른 임피던스 크기와 위상차 변화는 유의적인 차이가 없었다.(p>0.05) 방사선 피폭 시 임피던스 변화는 대조군과 비교했을 때 1 Gy, 2 Gy, 4 Gy 피폭 선량에서는 임피던스 크기는 감소하였으나, 유의적인 차이는 없었다.(p>0.05) 그러나 10 Gy 피폭 선량에서는 임피던스 크기 감소가 유의적으로 나타났다.(p<0.05) 방사선 피폭선량이 증가하여도 위상차 변화는 거의 없었으며, 대조군과 비교했을 때 1 Gy, 2 Gy, 4 Gy, 10 Gy 모두 유의적인 차이가 없었다.(p>0.05) 본 연구를 통해 생체 조직의 전기적 특성을 이해 할 수 있었고, 방사선 피폭선량에 따른 임피던스 변화를 측정하여 방사선이 인체에 미치는 영향을 직접 평가 할 수 있는 가능성을 확인 할 수 있었다.