• 제목/요약/키워드: radiation dose distribution

검색결과 727건 처리시간 0.022초

Magnetic resonance image-based tomotherapy planning for prostate cancer

  • Jung, Sang Hoon;Kim, Jinsung;Chung, Yoonsun;Keserci, Bilgin;Pyo, Hongryull;Park, Hee Chul;Park, Won
    • Radiation Oncology Journal
    • /
    • 제38권1호
    • /
    • pp.52-59
    • /
    • 2020
  • Purpose: To evaluate and compare the feasibilities of magnetic resonance (MR) image-based planning using synthetic computed tomography (sCT) versus CT (pCT)-based planning in helical tomotherapy for prostate cancer. Materials and Methods: A retrospective evaluation was performed in 16 patients with prostate cancer who had been treated with helical tomotherapy. MR images were acquired using a dedicated therapy sequence; sCT images were generated using magnetic resonance for calculating attenuation (MRCAT). The three-dimensional dose distribution according to sCT was recalculated using a previously optimized plan and was compared with the doses calculated using pCT. Results: The mean planning target volume doses calculated by sCT and pCT differed by 0.65% ± 1.11% (p = 0.03). Three-dimensional gamma analysis at a 2%/2 mm dose difference/distance to agreement yielded a pass rate of 0.976 (range, 0.658 to 0.986). Conclusion: The dose distribution results obtained using tomotherapy from MR-only simulations were in good agreement with the dose distribution results from simulation CT, with mean dose differences of less than 1% for target volume and normal organs in patients with prostate cancer.

Influence of Intravenous Contrast Medium on Dose Calculation Using CT in Treatment Planning for Oesophageal Cancer

  • Li, Hong-Sheng;Chen, Jin-Hu;Zhang, Wei;Shang, Dong-Ping;Li, Bao-Sheng;Sun, Tao;Lin, Xiu-Tong;Yin, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권3호
    • /
    • pp.1609-1614
    • /
    • 2013
  • Objective: To evaluate the effect of intravenous contrast on dose calculation in radiation treatment planning for oesophageal cancer. Methods: A total of 22 intravein-contrasted patients with oesophageal cancer were included. The Hounsfield unit (HU) value of the enhanced blood stream in thoracic great vessels and heart was overridden with 45 HU to simulate the non-contrast CT image, and 145 HU, 245 HU, 345 HU, and 445 HU to model the different contrast-enhanced scenarios. 1000 HU and -1000 HU were used to evaluate two non-physiologic extreme scenarios. Variation in dose distribution of the different scenarios was calculated to quantify the effect of contrast enhancement. Results: In the contrast-enhanced scenarios, the mean variation in dose for planning target volume (PTV) was less than 1.0%, and those for the total lung and spinal cord were less than 0.5%. When the HU value of the blood stream exceeded 245 the average variation exceeded 1.0% for the heart V40. In the non-physiologic extreme scenarios, the dose variation of PTV was less than 1.0%, while the dose calculations of the organs at risk were greater than 2.0%. Conclusions: The use of contrast agent does not significantly influence dose calculation of PTV, lung and spinal cord. However, it does have influence on dose accuracy for heart.

고선량율 관내 방사선치료를 위한 종양선량분포의 최적화에 대한 연구 (Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy)

  • 추성실;김귀언;노준규
    • Radiation Oncology Journal
    • /
    • 제12권2호
    • /
    • pp.243-252
    • /
    • 1994
  • 원격조종 아프터로딩에 의한 고선량율 관내삽입조사는 체내 발생된 종양에 방사선원을 근접시켜 치료하는 방사선요법으로서 신속한 선량계산과 선량의 정확성 및 다양한 모양의 최적선량분포가 요구된다. 저자들은 크기가 작고 선량율이 높은 고선량율의 방사성동위원소에 대한 정확한 조사선량과 최적선량분포를 얻기 위하여 수학적인 콤퓨터 계산프로그램과 실측으로서 비교하였다. 고선량율 선원에 의한 방사선 조사선량과 조직내 흡수선량분포는 각각 Sievert적분식과 Meisberger의 다항식을 이용하여 작성하였다. 종양크기와 모양에 가장 알맞는 선량분포의 최적화를 실현하기 위하여 저자들은 치료기준점의 선량을 일정한 값으로 고정시키고 선원의 조사시간을 조정하는 선형반복 계산방정식을 이용하였다. 모형선원이 장착된 아프터로딩관을 삽입하고 조준엑스선으로 촬영하여 종양부위를 결정한 후 콤퓨터의 도움으로 아프터로딩관의 축과 평행한 등량곡선 또는 과일모양의 선량분포 및 기관지 모양의 등선량분포가 성취되도록 선량최적화를 시행하였고 선량계에 의한 실측치와 오차가 $3\%$이하로 잘 일치하였다.

  • PDF

의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구 (Medical Radiation Exposure Dose of Workers in the Private Study of the Job Function)

  • 강천구;오기백;박훈희
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.3-12
    • /
    • 2011
  • 본 연구는 방사성동위원소의 의학적 이용도가 증가함에 따라 의료기관 핵의학과 방사선관계종사자의 직무별 방사선 이용에 대한 개인 방사선피폭선량의 실태를 파악하여, 방사선 위험에 대해 경각심을 고취시키고, 방사선 관계종사자들에게 안전관리와 합리적인 피폭선량 관리에 도움을 주고자 분석하였다. 2010년 1월 1일부터 2010년 12월 31일까지 의료기관에서 근무하는 방사선종사자로 분류되어 개인 방사선피폭선량 측정을 정기적, 연속적으로 1년간 조사 관리된 540명의 종사자를 대상으로 부서별, 선량영역구간별, 근무기간별, 직무별 관련업무를 파악하여 심부선량에 대하여 연간평균피폭선량을 각각 분석하였다. 분석법으로는 빈도분석과 ANOVA를 시행하였다. 의료기관 방사선종사자의 부서별 연간피폭선량은 핵의학과 4.57 mSv로 가장 높았으며, 심장혈관중재술실 2.09 mSv, 마취통증의학과 1.42 mSv, 영상의학과 1.10 mSv, 구강악안면 방사선과 0.59 mSv, 방사선종양학과 0.50 mSv 순으로 높게 나타났다. 선량영역별 분포는 핵의학과, 심장혈관중재술실에서 5.01~19.05 mSv의 높은 선량영역분포를 보였으며, 부서별 방사선사의 연간피폭선량은 핵의학과 7.14 mSv로 가장 높은 피폭선량을 보이고 있으며, 심장혈관중재술실 1.46 mSv로 높았고, 영상의학과 0.97 mSv, 구강악안면방사선과 0.66 mSv, 방사선종양학과 0.54 mSv 순으로 나타났다. 세부업무에 따른 직무별 연간평균피폭선량은 싸이크로트론 관련 합성 업무 17.47 mSv로 가장 높은 피폭선량을 보였으며, Gamma camera 영상실 7.24 mSv, PET/CT 영상실 업무가 7.60 mSv로 높게 나타났고, 인터벤션 2.04 mSv, 심혈관중재술실 1.46 mSv, 일반촬영 1.21 mSv, Primart 치료실 0.90 mSv, 구강악안면방사선과 일반촬영 0.66 mSv 순으로 나타났다. 근무기간별, 선량영역별에 따른 연간평균피폭선량은 구강악안면방사선과에서는 10~14년 종사자가 1.01~3.00 mSv로 높은 평균선량을 보였고, 방사선종양학과는 모든 근무기간에 따라 0.00~1.00 mSv 의 낮은 선량영역구간에서 분포를 보였으며, 심혈관중재술실은 10~14년, 15~19년 근무에 따라 각각 1.01~3.00 mSv 선량영역구간에서 분포하였으며, 영상의학과에서는 1~4년, 5~9년 종사자가 각각 1.01~8.00 mSv의 가장 높은 선량영역구간에서 분포를 보였고, 핵의학과에서는 1~4년, 5~9년 종사자가 각각 3.01~19.05 mSv 의 가장 높은 선량영역구간에서 분포를 보였으며, 10~14년, 15~19년 종사자에서도 각각 3.01~15.00 mSv의 높은 선량영역구간에서 분포를 보였다. 이와 같은 결과로 볼 때 의료기관에서 근무하는 방사선관계종사자의 대부분이 현재의 방사선 안전관리가 실효성 있게 이루어지고 있었으며, 직무특성에 따라 많은 차이가 있는 것을 알게 되었다. 그러나 방사선 피폭을 최소화시키는 노력이 필요하며, 이를 위해서 체계적 교육과 합리적인 피폭량 관리를 위한 체계가 필요하다고 사료된다.

  • PDF

CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구 (Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation)

  • 공효금;이기백
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.

세기조절방사선치료에서 선량율 변화에 따른 선량분포 특성 (Property of Dose Distribution in Accordance with Dose Rate Variation in Intensity Modulated Radiation Therapy)

  • 강민규;김성준;신현수;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제21권2호
    • /
    • pp.218-222
    • /
    • 2010
  • 세기조절방사선치료(intensity modulated radiation therapy, IMRT)는 치료면적을 소조사면으로 나누어 여러 방향에서 방사선이 조사되기 때문에 기존의 치료방법에 비해 많은 MU와 더 긴 치료시간이 요구된다. 통증 및 장애 등으로 인해 장시간 같은 자세를 유지하기 어려운 환자의 경우, 효과적인 치료를 위해서는 선량율을 증가시켜 치료시간을 줄이는 것이 한 방법이다. 본 연구에서는 선량율 변화에 따른 선량 및 선량분포를 측정하고 그 변화를 알아보았다. IMRT 치료계획은 ECLIPSE 시스템(Varian, SomaVision 6.5, USA)을 이용하여, $0^{\circ}$, $72^{\circ}$, $144^{\circ}$, $216^{\circ}$, $288^{\circ}$ 방향의 5문 조사로 계획하였다. 선량율 변화에 따른 선량 및 선량분포 확인을 위해 선량율은 100, 300, 500 MU/min으로 설정하였으며, 선량과 선량분포는 이온함(PTW, TN31014)과 필름(EDR2, Kodak)을 이용하여 각각 측정하였다. 이때 필름 선량계는 아크릴 팬톰에 삽입 후 빔의 조사방향과 나란하게 설치되었고 방사선조사를 위한 선형가속기는 21EX-S (Varian, USA)를 이용하였다. 측정된 필름 선량계는 VXR-16 (Vidar System Corporation)을 이용하여 분석함으로써 선량분포를 확인하였다. 선량율이 증가할수록 CTV를 포함하는 100% 선량분포의 면적이 거의 선형적으로 감소함을 보였다.

유리선량계를 이용한 Biobeam8000 감마선 조사장치의 선량평가 (Evaluation of Dose Distribution Using a Radiophotoluminescence Glass Dosimeter in Biobeam8000 Gamma Irradiation Device)

  • 신상훈;이성현;손기홍;이현호;김금배;정해조;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.198-205
    • /
    • 2011
  • 감마선조사장치는 세포실험, 동물실험, 혈액방사선 조사, 선량측정 실험 및 교육 등에 널리 사용되고 있다. 한국원자력의 학원에서 보유하고 있는 Biobeam8000 (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs-137, 81.4 TBq) 감마선 조사장치는 7.5 L의 대용량과 넓은 영역에 사용이 가능한 감마선 조사장치이다. 비커 내부에 균일한 방사선조사를 위해 Cs-137 선원이 위아래 24 cm 범위를 일정한 주기로 왕복 이동하며, 기존의 다른 감마선 조사기와 같이 시료를 넣는 비커는 방사선 조사동안 360도 회전한다. 기존의 감마선 조사기와 달리 비교적 균일한 선량이 조사되는 반면에 방사선원이 이동하므로 위치에 따른 구체적인 선량정보도 필요로 하게 된다. 본 연구에서는 유리 선량계를 이용하여 Biobeam8000 감마선 조사장치의 비커 내부 선량을 측정하였고, 측정결과를 바탕으로 선량선형성과 선량재현성에 대한 평가 및 선량분포의 정보를 도출하였다. 이 결과를 바탕으로 실험 및 방사선 조사 시 효율적인 조사장치 사용을 위한 가이드라인을 제시하고자 한다.

선량강도 조절법을 이용한 방사선치료에서 총선량에 관한 고찰 (A Study of Total Dose in Intensity Modulation Radiation Therapy)

  • 김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제11권1호
    • /
    • pp.85-90
    • /
    • 2000
  • 방사선치료에서 치료의 효과는 총선량, 치료회수, 1회 조사선량 등에 의해서 결정된다. 선량강도조절법을 사용하여 방사선치료를 행할 때 치료회수나 1회 조사선량을 고려하여 총선량에 미치는 효과를 살펴보고자 한다. 방사선치료의 목적은 암조직에는 충분한 선량을 조사하면서 주위 정상 조직에는 최소한의 선량을 조사되게 하여 치료성적의 향상으로 암환자의 생존율과 삶의 질을 높이는데 목적이 있다. 이러한 문제를 해결하기 위하여 많은 연구자들이 여러 가지 방법으로 해결하고자 노력한 결과 CT의 영상을 치료계획에 이용할 수 있게 되어 three dimensional conformal radiation therapy(3DCRT)를 개발하였다. 선량강도조절법을 시행하여 총선량을 75, 80, 85, 90Gy를 조사할 때, 처음부터 선량강도조절법을 사용하여 치료하는 경우와 일차적으로 45Gy를 조사하고 boost를 조사할 때 나머지 선량을 선량강도조절 법으로 사용하는 것을 TDF 환산법을 사용하여 비교하였다. 처음부터 선량강도조절법으로 치료할 경우에는 총선량에서 약 12.5 - 15 Gy 정도 감해서 조사하여야 하는 것으로 나타났다.

  • PDF

광자선과 전자선의 인접조사에서 선속 퍼짐현상이 고려된 전자선 차폐물을 이용한 접합 조사면의 선량분포 특성 (Characteristics of Dose Distribution at Junctional Area Using the Divergency Cutout Block in the Abutted Field of Photon and Electron Beams)

  • 임인철;이재승
    • Journal of Radiation Protection and Research
    • /
    • 제36권3호
    • /
    • pp.168-173
    • /
    • 2011
  • 본 연구는 조사통(electron cone)에 삽입되는 전자선 차폐물의 제작방법에 따른 X-선과 전자선의 인접 조사면의 선량분포 특성을 알아보고자 하였다. 차폐물의 제작은 전자선속 퍼짐현상을 고려한 차폐물(divergency block)과 고려하지 않은 차폐물(straight block)을 구분하여 제작하였다. 6 MV X-선과 10 MeV 전자선을 대상으로 표면에서 X-선과 전자선의 조사면을 인접시키고 측정 깊이 0, 1, 2, 3 cm에서 빔 측면도(beam profile)를 측정하였다. 측정 결과 인접 조사면의 선량분포는 straight block의 경우, 기준 투여선량의 5%를 초과하는 고선량 영역과 인접 조사면에서 급격한 선량분포를 형성하였으나 divergency block의 경우, 측방산란효과가 감소함으로서 고선량 영역이 현저하게 감소하였으며 인접 조사면에서 균일한 선량분포를 보였다. 따라서 전자선속 퍼짐을 고려한 경우 선량학적 이점을 제공하였고 이를 임상에 적용하기 위하여 전자선의 차폐물 제작방법에 따른 선량측정을 신중하게 고려해야 할 것이다.

횡방향 자기장이 고에너지 전자선의 선량분포에 미치는 영향 (Effect of Transverse Magnetic Field on Dose Distribution of High Energy Electron Beam)

  • 오영기;김기환;신교철;김진기;김정기;정동혁;조문준;김준상;윤선민;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제18권4호
    • /
    • pp.209-213
    • /
    • 2007
  • 20 MeV 전자선의 팬텀 내에서의 선량분포에 대한 횡방향 자기장 효과를 조사하기 위하여 전자석을 제작하여 자기장 인가 여부에 따른 등선량곡선 및 깊이선량율을 X-OMAT 필름으로 측정하였다. 1.5 Tesla의 자기장중심을 팬텀 표면으로부터 7.5 cm 깊이에 위치시킨 경우 팬텀 표면으로부터 4.5 cm 깊이에서 약 30%의 선량증가를 보이는 등 이론적으로 알려진 결과들과 잘 부합하고 있음을 확인하였다.

  • PDF