• 제목/요약/키워드: radiation detector

검색결과 842건 처리시간 0.024초

X선 진단영역 에너지 측정을 위한 Photo-Diode 선량계(PD-2000)의 개발 (The development of photo-diode dosimeter(PD-2000) for the diagnostic X-ray Energy)

  • 김성철;이우철;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.27-32
    • /
    • 2000
  • It was produced radiation dosimeter used photo-diodes for which ionization by x-ray was applied and evaluated the value of utility in clinics as compared with ion-chamber. The result obtained were as follows : 1. Comparison of ion-chamber with photo-diode dosimeter's x-ray output by the change of x-ray tube voltage, and the ratio of ion-chamber to diode was $0.96{\sim}1.02$ which was not affected by x-ray beam quality. 2. The ratio of ion-chamber to diode was 0.96 by change of tube current and 0.97 by change of exposure time that is not affected by x-ray quantity. 3. The ratio of ion-chamber to diode was $0.97{\sim}1.04$ by thickness and $0.93{\sim}1.10$ by radiation field that is little affected by second ray quantity. 4. Reproducibility of photo-diode dosimeter was 0.011(CV) and it is a good result. 5. Photo-diode dosimeter was affected by the surface angle of detector over 30 degrees. Produced dosimeter was small, light, and meets good result compared with ionization chamber. It was expected come into wide use in clinic.

  • PDF

Cellulose Nitrate 고체비적검출기(固體飛跡檢出器)의 부식조건(腐蝕條件) (On the Etching Condition of Cellulose Nitrate Solid State Nuclear Track Detector (SSNTD))

  • 명동범;전재식
    • Journal of Radiation Protection and Research
    • /
    • 제12권1호
    • /
    • pp.26-33
    • /
    • 1987
  • 알파입자 검출을 위한 고체 비적 검출기인 CA 8-15와 LR 115-1은 그 부식조건이 검출기 제조 회사에서 이미 주어지고는 있으나 이들 검출기에 대한 최적부식에 관한 실험적 검토를 다시 행하였는바 최적부식시간에 현저한 차이가 있음을 발견하였다. 검출기의 방사선 조사는 이미 설정된 기하학적 배치조건하에서 $0.1{\mu}Ci$수준의 $^{241}Am$ 알파선원으로 수행하였다. 부식시간과 용액 농도의 함수로서의 비적크기에 대한 분석과 검출기에 검출된 단위면적당 비적의 이론적 기대치에 대한 비교 조사를 행하였으며, 입사 알파입자의 유효 에너지에 대한 검출효율의 변화에 대해서도 연구하였다.

  • PDF

AN IV CATHETER FRAGMENTS DURING MDCT SCANNING OF HUMAN ERROR: EXPERIMENTAL AND REPRODUCIBLE MICROSCOPIC MAGNIFICATION ANALYSIS

  • Kweon, Dae-Cheol;Lee, Jong-Woong;Choi, Ji-Won;Yang, Sung-Hwan;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • 제36권4호
    • /
    • pp.195-199
    • /
    • 2011
  • The use of intravenous catheters are occasionally complicated by intravascular fragments and swelling of the catheter fragments. We present a patient in whom an intravenous catheter fragments was retrieved from the dorsal metacarpal vein following its incidental CT examination detection. The case of demonstrates the utility of microscopy and multi-detector CT in localizing small of subtle intravenous catheter fragments as a human error. A case of IV catheter fragments in the metacarpal vein, in which reproducible and microscopy data allowed complete localization of a missing fragments and guided surgery with respect to the optimal incision site for fragments removal. These reproducible studies may help to determine the best course of action and treatment for the patient who presents with such a case.

Experimental Investigation of Clay Fly Ash Bricks for Gamma-Ray Shielding

  • Mann, Harjinder Singh;Brar, Gurdarshan Singh;Mann, Kulwinder Singh;Mudahar, Gurmel Singh
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1230-1236
    • /
    • 2016
  • This study aims to determine the effect of fly ash with a high replacing ratio of clay on the radiation shielding properties of bricks. Some interaction parameters (mass attenuation coefficients, half value layer, effective atomic number, effective electron density, and absorption efficiency) of clay fly ash bricks were measured with a NaI(Tl) detector at 661.6 keV, 1,173.2 keV, and 1,332.5 keV. For the investigation of their shielding behavior, fly ash bricks were molded using an admixture to clay. A narrow beam transmission geometry condition was used for the measurements. The measured values of these parameters were found in good agreement with the theoretical calculations. The elemental compositions of the clay fly ash bricks were analyzed by using an energy dispersive X-ray fluorescence spectrometer. At selected energies the values of the effective atomic numbers and effective electron densities showed a very modest variation with the composition of the fly ash. This seems to be due to the similarity of their elemental compositions. The obtained results were also compared with concrete, in order to study the effect of fly ash content on the radiation shielding properties of clay fly ash bricks. The clay fly ash bricks showed good shielding properties for moderate energy gamma rays. Therefore, these bricks are feasible and eco-friendly compared with traditional clay bricks used for construction.

편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰 (Study of photon beam quality tool at magnetic field change in bending magnet)

  • 김정호;유세종;박명철;배석환;김기진
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.

Monte Carlo simulation of the electronic portal imaging device using GATE

  • 정용현;백철하;이승재
    • 한국방사선학회논문지
    • /
    • 제1권3호
    • /
    • pp.11-16
    • /
    • 2007
  • 새로 개발된 몬테칼로 모사코드인 GATE의 방사선치료 분야에의 적용성 검토를 위하여 방사선치료 오차확인용 전자포탈영상장치에 사용되는 금속판/형광스크린 계측기의 특성을 예측 및 분석하였다. GATE를 이용하여 계산한 6 MV 선형가속기에서 발생되는 엑스선의 에너지 스펙트럼을 바탕으로, 여러가지 두께의 금속판/형광스크린에 대하여 계측효율과 공간분해능을 계산하였고, 이를 범용으로 사용되는 MCNP4B 모사 결과 및 실험 결과와 비교하여, 방사선치료 분야에 응용 가능성을 검증하였다.

  • PDF

방사능 존재확인과 정량분석시 최적화된 측정시간의 결정을 위한 계측전략 (Counting Strategies in Radioactivity Measurement for the Monitoring and Screening)

  • 서경원
    • Journal of Radiation Protection and Research
    • /
    • 제23권2호
    • /
    • pp.65-74
    • /
    • 1998
  • 저 준위방사능 계측에서 가장 기본적으로 요구되는 것이 최적 측정시간의 결정이다. 최적화된 계측전략으로 측정시간을 결정하기 위하여 측정시간을 고정하는 방법, 측정값을 고정하는 방법, 시료와 자연계수율 또는 기준준위를 비교하여 측정하는 방법을 비교 검토하는 결정식을 도출하였다. 이 계측전략에서 기기에 주어진 측정조건 즉, 검출기의 효율, 측정기의 용량, 측정기의 최대 및 평균 자연계수율과 관련기준 즉, 기준준위, 검출한계 등을 만족하는 측정시간이 결정된다. 계측전략은 측정시 주어진 조건에서 방사능 존재확인과 정량분석에 대한 시료의 최적 측정시간의 결정을 편리하게 함으로써 일상의 저준위방사능 측정에 유용하게 사용될 것이다.

  • PDF

동위원소를 이용한 연안역 현장실험 (A Field Tracer Experiment by Using a Radioisotope near the Offshore)

  • 김기철;박건형;이진용;정성희;민병일;서경석
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.41-47
    • /
    • 2012
  • A field tracer experiment using a radioisotope was conducted to analyze the transport and dispersion characteristics of pollutants in the coastal area near a Wolsung. A rod float including GPS was released to track the paths of radioisotope. NaI detector was installed to measure the released radioisotope from the boat, and measurements were performed with the real time. The measured tracer data by a field experiment can be used as the basic data for understanding the transport characteristics of pollutants and verifying numerical models near the offshore.

방사성추적자를 이용한 수직교반형 소화조의 유동 특성 측정 (Measurement of Flow Characteristics of Digester Installed Tray Motioned Mixer by Using Radiotracer)

  • 문진호;박장근;강문후;정성희
    • 방사선산업학회지
    • /
    • 제9권3호
    • /
    • pp.131-135
    • /
    • 2015
  • The flow characteristics of fluid were measured using radioactive tracer in pilot scale digester with tray motion mixer. In consideration of the detection volume of the detector and the size of the digester, 20 detectors were installed in the digester. The radioactive tracer eluted 8 mCi of $^{68}Ga$ from $^{68}Ge/^{68}Ga$ generator was injected into the digester bottom. After radiotracer injection, the flow pattern was measured on the basis of the initial movement of the tracer until its diffusion completely. Most of tracer moved to the wall along the bottom of the digester, and then rose along the wall. The other tracer moved up along the mixer, and then moved to the wall direction along the surface.

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.