• 제목/요약/키워드: radiation detector

검색결과 843건 처리시간 0.038초

Scientific Missions and Technologies of the ISSS on board the NEXTSat-1

  • Choi, Cheong Rim;Sohn, Jongdae;Lee, Jun-Chan;Seo, Yong Myung;Kang, Suk-Bin;Ham, Jongwook;Min, Kyoung-Wook;Seon, Jongho;Yi, Yu;Chae, Jang-Soo;Shin, Goo-Hwan
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권1호
    • /
    • pp.73-81
    • /
    • 2014
  • A package of space science instruments, dubbed the Instruments for the Study of Space Storms (ISSS), is proposed for the Next Generation Small Satellite-1 (NEXTSat-1), which is scheduled for launch in May 2016. This paper describes the instrument designs and science missions of the ISSS. The ISSS configuration in NEXTSat-1 is as follows: the space radiation monitoring instruments consist of medium energy particle detector (MEPD) and high energy particle detector (HEPD); the space plasma instruments consist of a Langmuir probe (LP), a retarding potential analyzer (RPA), and an ion drift meter (IDM). The space radiation monitoring instruments (MEPD and HEPD) measure electrons and protons in parallel and perpendicular directions to the geomagnetic field in the sub-auroral region, and they have a minimum time resolution of 50 msec for locating the region of the particle interactions with whistler mode waves and electromagnetic ion cyclotron (EMIC) waves. The MEPD measures electrons and protons with energies of tens of keV to ~400 keV, and the HEPD measures electrons with energies of ~100 keV to > ~1 MeV and protons with energies of ~10 MeV. The space plasma instruments (LP, RPA, and IDM) observe irregularities in the low altitude ionosphere, and the results will be compared with the scintillations of the GPS signals. In particular, the LP is designed to have a sampling rate of 50 Hz in order to detect these small-scale irregularities.

Blocking layer 적용을 통한 HgI2 방사선 변환센서의 신호대 잡음비 향상에 관한 연구 (Study on Improvement of Signal to Noise Ratio for HgI2 Radiation Conversion Sensor Using Blocking Layer)

  • 박지군;윤인찬;최수림;윤주선;이영규;강상식
    • 한국방사선학회논문지
    • /
    • 제5권2호
    • /
    • pp.97-101
    • /
    • 2011
  • 본 연구에서는 적충 구조를 이용하여 누설전류를 저감 시키는 기술을 적용하여 입자침전법을 이용한 방사선 영상 센서의 변환 물질을 개발하였다. 이는 디지털 방사선 영상 검출기의 두 가지 방식 중 하나인 직접방식에 사용되는 핵심 소자로 기존의 비정질셀레늄(a-Se)을 대체하여 더욱 효율이 높은 후보 물질들이 연구되어지는 가운데 태양전지와 반도체 분야에서 이미 많이 사용되어온 이종접합을 이용해 누설 전류를 저감 시키는데 그 목적이 있다. 본 연구에서 사용되는 입자 침전법 제조방법은 검출 물질 제작이 용이하고 높은 수율과 대면적의 검출기 제작에 적합하나 높은 누설 전류가 의료 영상에 있어서 문제가 되어 오고 있다. 이러한 단점을 보완하기 위해 적충 구조를 이용하여 누설 전류를 저감시킨다면 PIB법을 이용하여 간편하게 향상된 효율의 디지털 방사선 검출기를 제작 할 수 있다고 사료 되어 진다. 본 연구에서는 누설 전류와 민감도에 대한 전기적 신호를 측정하여 제작된 적충 구조의 방사선 검출 물질의 특성 평가가 이루어 졌다.

저온검출기를 이용한 에너지 고 분해능 알파분광 구현 (High Energy Resolution Alpha Spectrometer Using a Cryogenic Detector)

  • 김민성;이상훈;윤원식;장용식;이상준;김용함;이민규
    • Journal of Radiation Protection and Research
    • /
    • 제38권3호
    • /
    • pp.132-137
    • /
    • 2013
  • 기존에 많이 사용된 반도체 검출기의 분해능은 통계학적 이론으로 그 분해능의 한계가 따른다. 이러한 이유로 최근에 반도체 검출기가 갖는 에너지 분해능의 한계를 뛰어넘는 저온 검출기를 이용하여 다양한 방사성 핵종 분석을 시도하고 있다. 본 논문에서는 $2{\times}2{\times}0.05mm^3$ 크기 금막 흡수체에 입사하는 에너지 때문에 흡수체의 온도가 상승하는 원리를 이용해 $^{241}Am$ 알파 선원의 에너지를 측정하였다. 흡수체의 온도 변화 측정에는 자기양자센서인 Au:Er를 이용하였으며 이는 순수한 Au에 핵스핀이 0 인 $^{168}Er$을 수백 ppm을 첨가하여 얻은 상자성 합금이다. 알파 입자 흡수에 의한 미세한 온도증가를 측정하기 위해서 희석식 냉동기보다 작동이 편리한 무냉매 자기냉동기를 이용해 mK 온도 영역의 저온환경을 구성하였다. $^{241}Am$ 선원 측정 결과 5.5 MeV에서 6.8 keV의 FWHM의 에너지 고 분해능을 얻었다.

400 MeV/u 탄소 이온에 대한 방사선치료 선량 측정용 고체비적검출기의 교정 (Calibration of CR-39 for Hadron Radiotherapy using 400 MeV/u C ions)

  • 김성환;남욱원;이재진;박원기;표정현;문봉곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.43-49
    • /
    • 2016
  • 본 연구에서는 탄소이온을 이용한 고LET 방사선 치료시 CR-39 고체비적검출기(SSNTD)를 선량계로 사용하기 위하여 일본 중입자가속기연구소(HIMAC)의 400 MeV/u 탄소 이온을 이용한 교정실험을 수행하였다. 탄소 이온을 조사한 CR-39 검출기는 일본 우주항공연구개발기구(JAXA)의 고체비적검출기 전처리 프로토콜에 따라 화학적 에칭을 하였고, 에칭된 CR-39 검출기의 표면에 형성된 트랙은 디지털 카메라로 촬영한 후 Image J를 이용하여 분석하였다. 분석결과 400 MeV/u 탄소 이온의 ${\bar{y_F}}$${\bar{y_D}}$는 각각 $8.5keV/{\mu}m$$10.1keV/{\mu}m$이었으며, 이 결과는 한국천문연구원의 조직등가비례계수기(TEPC)로 측정한 값 및 GEANT4 몬테칼로 시뮬레이션으로 계산한 값과 잘 일치하였다. 본 연구를 통하여 CR-39의 선량 및 LET 교정인자를 결정할 수 있었으며, 고LET 방사선 치료시 CR-39를 이용한 선량평가의 가능성을 확인하였다.

광중성자 발생으로 인한 전립샘암 환자의 유전적 위험과 발암의 확률에 관한 연구 (A Study on the Genetic Risk and Carcinogenesis Probability of Prostate Cancer Patients Due to Photoneutron Generation)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.473-479
    • /
    • 2023
  • 본 연구에서는 고 에너지를 이용한 전립샘암의 방사선 치료 시 발생되는 광중성자의 선량을 광자극발광선량계를 사용하여 측정하였다. 이에 따른 복부에 발생되는 유효선량에 의한 유전적 위험확률을 연구하고자 하였다. 15 MV 에너지 발생이 가능한 의료용 선형가속기 True Beam STx(Varian Medical Systems, USA)와 방사선 치료 계획 시스템(Eclipse, Varian Medical System, USA)을 사용하였다. 선형가속기 Couch 위에 인체팬텀을 설치하고, 광중성자 선량의 측정은 Albedo Neutron Optical Stimulation Luminescence Neutron Detector(Landauer Inc., IL, USA)를 사용하였다. VMAT과 3C-CRT 의 복부에서 광중성자 선량값은 VMAT이 3D-CRT에 비하여 2배 이상 높은 52.8 mSv 였다. 전립샘암의 방사선 치료 시, 광중성자 선량으로 인한 복부에 발생되는 유효선량에 의한 유전적 위험확률은 VMAT는 1,000명 당 3.2명, 3D-CRT는 1.4명이 발생률임을 산출하였다. 전립샘암의 방사선 치료 시 발생할 수 있는 큰 부작용이 있는 복부를 연구함으로써 전립샘암 환자들의 삶의 질과 확률적 영향을 연구하는데에 의미 있는 연구로 활용되어지길 기대한다.

건축재료로부터 방출되는 라돈방사능 감소를 위한 흑탄과 활성탄 효과 (Effect of Black Charcoal and Activated Carbon for Reduction of Radon Radioactivity that Emitted from Building Materials)

  • 조윤민;이화형
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.13-17
    • /
    • 2011
  • Recently, interest in indoor air quality is increasing. Especially, radon radioactivity among the indoor air is a well-known risk factor for lung cancer because of ionizing radiation in the form of ${\alpha}$-particles. This study was carried out to investigate effect of black charcoal and activated carbon for reduction of radon radiation that emitted from building materials. Black charcoal and activated carbon were used as a barrier which was against the infiltration of radon. The source of radon was gypsum board. Two types of charcoal barrier were powder- and board-type with 5 mm, 10 mm thickness respectively. The method for this determination is evaluated radon concentration in chamber. The measurements were performed with radon detector, SARAD3120. Results of this study are as following: Black charcoal and activated carbon confirmed the highly efficient barrier. Radon concentration was reduced from 72% to 85% as compared the control chamber. Radon reduction capability, however, was no difference as barrier's types. Results obtained in ventilation condition, radon concentration shows 5.93 pCi/L on average in the closed condition and shows 2.69 pCi/L in the opened condition.

  • PDF

교육용 모사 HPGe 검출기 스펙트럼 개발 (Development of Simulated HPGe Detector Spectrum for Education)

  • 서경원;이모성
    • Journal of Radiation Protection and Research
    • /
    • 제32권1호
    • /
    • pp.9-13
    • /
    • 2007
  • 원통형 용기에 담긴 액체 혼합선원의 HPGe 검출기 교정용 스펙트럼으로부터 스펙트럼 분석 교육을 위한 모사 스펙트럼을 개발하였다. 모사 스펙트럼은 측정된 스펙트럼으로부터 피크를 분리한 후, 채널별 계수들의 변동이 제거된 스펙트럼을 결합한 것이다. 모사 스펙트럼의 통계적 변동은 Box-Muller 함수로 만들었다. 이 스펙트럼은 18개의 피크를 포함하고 있다. 각 피크의 중심 위치 및 면적 등은 정확하게 정의되었다. 개발된 스펙트럼은 교정용 스펙트럼, 시료 스펙트럼, 백그라운드 스펙트럼 그리고 기하학적 및 동시합성 보정을 위한 스펙트럼이다.

SEPARATION OF GAMMA-RAYS PRODUCTION FROM $^{13}C(p,\;{\gamma})^{14}N,\;^{14}N({\gamma},\;{\gamma})^{14}N$ REACTIONS USING DOPPLER SHIFT EFFECT

  • Kim, Y.K.;Ha, J.H.;Youn, M.;Han, S.H.;Chung, C.E.;Moon, B.S.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.287-290
    • /
    • 2001
  • The 9.17MeV gamma-rays from the $^{13}C(p,\;{\gamma})^{14}N,\;^{14}N({\gamma},\;{\gamma})^{14}N$ reactions were measured. The incident 9.17MeV gamma-ray was produced from the $^{13}C(p,\;{\gamma})^{14}N$ reaction at Ep=1.75MeV resonance. The 1.75MeV proton beam was accelerated using the 3MV SNU-AMS Tandetron and 1.7MV KIGAM Tandem accelerators. The enriched 13C target was $121{\mu}g/cm^2$ self-supporting foil, and we used liquid nitrogen as a resonant absorption target. We used a HP-Ge detector with 30% efficiency and less 2keV energy resolution. We developed new method to detect the scattered 9.17MeV gamma-ray from the nitrogen target by using the energy difference between the Doppler shifted gamma-ray from the $^{13}C(p,\;{\gamma})^{14}N$ reaction and the resonant absorbed and rescattered gamma-ray from the $^{14}N({\gamma},\;{\gamma})^{14}N$ reaction.

  • PDF

영상센서를 이용한 방사선원 위치탐지 연구 (A Study on a position detection of radiation using CCD camera)

  • 이남호;최창환;신호철;정승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.324-326
    • /
    • 2006
  • CCD형 영상소자는 방사선 피폭 시 표면과 격자내부에 모두 손상을 받게 되며, 감마방사선이나 X선과 같은 고에너지의 이온화 방사선에 노출될 경우 격자 실리콘 내부에 전자-전공쌍(Electron-hole pair, EHP)이 발생된다. 이러한 EHP는 CCD의 순간 출력 광전류로 변환되어 백색 화소 형태의 영상잡음으로 가시화되며, 이 화소 수는 피폭 방사선량에 비례하여 증가하는 특성을 지니고 있다. 따라서 출력 영상정보를 분석하면 조사된 방사선의 양과 특성을 측정할 수 있다. 본 연구에서는 CCD를 이용하여 가상의 방사능 물질 누출 공간에서 방사선원의 방향과 거리정보를 고속으로 탐지하기 위한 장치와 고속 측정 알고리즘을 구현하고 실제 방사선장에서 실증시험을 수행하였다. 방사선 탐지기는 콘형 납 콜리메이터(Collimator)와 가시광 변환용 신틸레이터(CsITl) 및 차폐체로 구성된 센서부와 제어 및 방사광 신호처리를 수행하는 PC부로 구성된다. 감마방사선($^{60}Co$) 방사선장 실증시험에서 방사선원간 거리 83cm에서 측정된 거리 탐지는 5.3%의 오차로 확인되었다. 이 방사선 탐지기는 임의의 고방사선 누출사고에 대한 초기대응 작업을 수행하기 위한 무인 이동로봇용 방사선 탐지기로 활용이 가능하다.

  • PDF

공기중의 라돈 농도 측정을 위한 CR-39의 교정 (Calibration of CR-39 for Measurement of Radon in Air)

  • 박영웅;장시영;하정우;노성기
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.18-22
    • /
    • 1989
  • CR-39 고체비적검출기를 교정하기 위하여 밀봉 순환 방식의 고체비적검출기 교정 장치와 밀리포어필터가 부착된 라돈컵을 제작한 후 기지의 라돈농도에 대한 비적 수를 측정하였다. 그 결과 CR-39 고체비적검출기의 단위 면적당 생성된 비적 수에 대한 시간 적분 라돈 농도는 $0.24{\pm}0.09(pCi/l){\cdot}day/(Tr/cm^2)$ 였다.

  • PDF