• 제목/요약/키워드: radiation detector

검색결과 842건 처리시간 0.028초

NEUTRON-INDUCED CAVITATION TENSION METASTABLE PRESSURE THRESHOLDS OF LIQUID MIXTURES

  • Xu, Y.;Webster, J.A.;Lapinskas, J.;Taleyarkhan, R.P.
    • Nuclear Engineering and Technology
    • /
    • 제41권7호
    • /
    • pp.979-988
    • /
    • 2009
  • Tensioned metastable fluids provide a powerful means for low-cost, efficient detection of a wide range of nuclear particles with spectroscopic capabilities. Past work in this field has relied on one-component liquids. Pure liquids may provide very good detection capability in some aspects, such as low thresholds or large radiation interaction cross sections, but it is rare to find a liquid that is a perfect candidate on both counts. It was hypothesized that liquid mixtures could offer optimal benefits and present more options for advancement. However, not much is known about radiation-induced thermal-hydraulics involving destabilization of mixtures of tensioned metastable fluids. This paper presents results of experiments that assess key thermophysical properties of liquid mixtures governing fast neutron radiation-induced cavitation in liquid mixtures. Experiments were conducted by placing liquid mixtures of various proportions in tension metastable states using Purdue's centrifugally-tensioned metastable fluid detector (CTMFD) apparatus. Liquids chosen for this study covered a good representation of both thermal and fast neutron interaction cross sections, a range of cavitation onset thresholds and a range of thermophysical properties. Experiments were devised to measure the effective liquid mixture viscosity and surface tension. Neutron-induced tension metastability thresholds were found to vary non-linearly with mixture concentration; these thresholds varied linearly with surface tension and inversely with mixture vapor pressure (on a semi-log scale), and no visible trend with mixture viscosity nor with latent heat of vaporization.

이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발 (Development of Measurement System for Industrial Transportable Gamma Ray CT)

  • 김종범;정성희;문진호
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Comparison of nano/micro lead, bismuth and tungsten on the gamma shielding properties of the flexible composites against photon in wide energy range (40 keV-662 keV)

  • Asgari, Mansour;Afarideh, Hossein;Ghafoorifard, Hassan;Amirabadi, Eskandar Asadi
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4142-4149
    • /
    • 2021
  • In the radiation protection application, the metal-polymer composites have been developed for their radiation shielding properties. In this research, the elastomer composites doped by 10 ㎛ and 100nm size of lead, bismuth and tungsten particles as filler with 30 and 60 wt percentages were prepared. To survey the shielding properties of the polymer composites using gamma-ray emitted from 152Eu and 137Cs sources, the gamma flux was measured by using NaI(Tl) detector, then the linear attenuation coefficient was calculated. Also, the Monte Carlo simulation (MCs) method was used. The results showed a direct relationship between the linear attenuation coefficients of the absorbent and filler ratio. Also, the decrease in the particle size of the shielding material in each weight percentage improved the radiation shielding features. When the dimension of the particles was in the order of nano-size, more attenuation was achieved. At low energies used for medical diagnostic X-ray applications due to the predominance of the photoelectric effect, bismuth and lead were suitable selection as filler.

Monte Carlo-based identification of electron and proton edges for calibration of miniaturized tissue equivalent proportional counter

  • Mingi Eom;Sukwon Youn;Sung-Joon Ye
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4167-4172
    • /
    • 2023
  • Miniaturized tissue equivalent proportional counters (mini-TEPCs) are proper for radiation dosimetry in medical application because the small size of the dosimeter could prevent pile-up effect under the high intensity of therapeutic beam. However, traditional methods of calibrating mini-TEPCs using internal alpha sources are not feasible due to their small size. In this study, we investigated the use of electron and proton edges on Monte Carlo-generated lineal energy spectra as markers for calibrating a 0.9 mm diameter and length mini-TEPC. Three possible markers for each spectrum were calculated and compared using different simulation tools. Our simulations showed that the electron edge markers were more consistent across different simulation tools than the proton edge markers, which showed greater variation due to differences in the microdosimetric spectra. In most cases, the second marker, yδδ, had the smallest uncertainty. Our findings suggest that the lineal energy spectra from mini-TEPCs can be calibrated using Monte Carlo simulations that closely resemble real-world detector and source geometries.

Novel bricks based lightweight Vietnam's white clay minerals for gamma ray shielding purposes: An extensive experimental study

  • Ta Van Thuong;O.L. Tashlykov;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.666-672
    • /
    • 2024
  • In the present work, a new brick series based on the Vietnamese white clay minerals from the Bat Trang was fabricated to be applied in the radiation protection applications during the decommissioning of the nuclear power reactors. The bricks were constructed under various pressure rates varied from 7.61 MPa to 114.22 MPa. The influence of pressure rate on the physical and γ-ray shielding properties were investigated in the study. The experimental measurement for the material's density using the MH-300A density meter showed an enhancement in the prepared bricks' density by 22.5 % with increasing the applied pressure rate while the bricks' porosity reduced by 31.2 % when the pressure rate increased from 7.61 MPa to 114.22 MPa. The increase in the fabricated bricks density and the reduction in their porosities enhances the bricks' linear attenuation coefficients as measured by the NaI (Tl) detector along the energy range extended from 0.662 MeV to 1.332 MeV. The linear attenuation coefficient increased by 13.8 %, 17.6 %, 17.0 %, and 17.1 % at gamma ray energies of 0.662 MeV, 1.173 MeV, 1.252 MeV, and 1.332 MeV, respectively. The enhancement in the linear attenuation coefficient increases the bricks' radiation protection efficiency by 10.22 %, 14.48 %, 14.09 %, and 14.26 % at gamma ray energies of 0.662 MeV, 1.173 MeV, 1.252 MeV, and 1.332 MeV, respectively.

환경시료의 방사능 분석에서 Monte Carlo 방법을 이용한 자체흡수 효과 보정 (Corrections of Self-Absorption Effect Using the Monte Carlo Method in the Radioactivity Analysis of Environmental Samples)

  • 서범경;이대원;이길용;윤윤일;양태건
    • Journal of Radiation Protection and Research
    • /
    • 제26권2호
    • /
    • pp.51-58
    • /
    • 2001
  • 환경방사능과 같은 저준위 방사능 측정에서는 원통형과 Marinelli형 측정용기가 가장 일반적으로 사용된다. 효율교정용 표준선원과 측정시료의 높이 또는 매질의 밀도가 다르면 자체흡수 효과의 차이로 인한 보정이 필요하다. 본 연구에서는 Monte Carlo 방법을 이용하여 HPGe 검출기의 전에너지 피크 효율을 계산하여 측정치와 비교하였다. 원통형 용기에 대해서는 높이에 대한 효율변화 정도를 계산하였고, 원통형 및 Marinelli 측정용기에 대해서는 밀도변화에 따른 효율을 계산하였다. 밀도에 따른 효율의 감소 정도는 1000keV 이하의 에너지 영역에 대해 자체흡수 효과의 보정치 필요하다는 것을 알았다. 또한 계산의 타당성을 검증하기 위하여 NIST SRM 4353 표준물질을 이용하여 계산값과 인증값을 상호비교한 결과 오차범위 이내로 잘 맞는 다는 것을 확인하였다.

  • PDF

CR-39 라돈컵을 이용한 국산 전축자재의 라돈-222 방출율 측정 (Measurement of Radon-222 Exhalation Rate from Building Materials by Using CR-39 Radon Cup)

  • 장시영;하정우;이병헌
    • Journal of Radiation Protection and Research
    • /
    • 제16권1호
    • /
    • pp.15-24
    • /
    • 1991
  • CR-39 플라스틱 핵비적검출기를 라돈검출기로 내장한 멤브레인 필터컵(일명 : CR-39 라돈컵)을 이용하여 일부 국산건축자재의 라돈방출율을 측정하였다. 표준라듐선원을 이용한 라돈컵의 교정 실험을 수행하여 얻은 CR-39 검출기의 라돈검출인자는 $0.164{\pm}0.005(tracks \;cm^{-2}/Bq\;d\;m^{-3})$였으며 타 연구자들의 발표결과와 잘 일치하였다. 일부 건축자재(모래벽돌, 적벽돌, 화장석판, 콘크리트 덩어리, 건물바닥과 내벽)에 CR-39 라돈컵을 2개월 동안 기밀 부착하여 라돈방출율을 측정한 결과, 라돈방출율은 모래벽돌에서 평균$(75.0{\pm}5.5){\times}10^{-6}(Bq/m^2-s)$, 화강석판에서 $(6.8{\pm}2.9){\times}10^{-6}Bq/m^2-s)$로 10배정도의 차이를 보였으며, 모래벽돌>콘크리트바닥>콘크리트덩어리>건물벽>적벽돌>화강석 판의 순서를 보였다. 본 연구 결과, CR-39 라돈컵에 의해서도 건축자재의 라돈방출율을 효과적으로 측정할 수 있음이 입증하였다.

  • PDF

적외선 카메라 KAONICS의 열해석 (A STUDY OF THERMAL ANALYSIS OF KAONICS)

  • 강지나;이성호;진호;박수종;문봉곤;김상호;박장현
    • Journal of Astronomy and Space Sciences
    • /
    • 제21권4호
    • /
    • pp.467-480
    • /
    • 2004
  • KAONICS(KAO Near Infrared Camera System)와 같은 적외선 카메라는 열잡음제거가 매우 중요하다. 입사창을 통해 들어오는 외부의 열복사 이외에도 카메라의 외벽을 통해 유입되는 열복사가 배경복사로서 검출기에 입사하여 시스템의 성능을 저하 시키며 그 양은 무시할 수 없다. 따라서 배경복사와 검출기 자체의 열잡음을 줄이기 위해서 카메라 내부의 광학계 전체와 검출기를 냉각해야만 한다. 이에 본 연구에서는 J, H, Ks, L 파장 대를 관측하기 위한 내부 냉각온도를 정량적으로 결정하였으며 카메라 외부에서 유입되는 복사량을 추산하고 냉각에 필요한 냉각 열용량을 추정하여 냉각기를 선택하였다. 선택된 냉각기를 이용하여 냉각할 때 Cold-Box가 목표온도에 도달하는 시간과 최종 냉각 온도를 계산하여 시스템 제작에 반영하였다.

슬개골 엑스선 영상 촬영을 위한 보조기구의 개발과 활용 (Development and use of Supporting Device for Patellar X-ray Imaging)

  • 이도병;서승준;최현우;이상훈;김종기
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권4호
    • /
    • pp.165-171
    • /
    • 2020
  • In this study, it focuses on the development of radiographic devices for patellar imaging. On the previous X-ray examination of patella and patellofemoral joint, it analyzed the problems which could affect the results: unstable patients' pose, radiation exposure, and deterioration of image quality. The purpose of the research is to propose a future use of a developed device with an explanation of the process, function, and advantage of the device including the methods. The device is developed to focus on the diagnosis of the longitudinal and longitudinal fractures of the patella and patella/femoral joint, displacement such as dislocation, bone formation, stenosis of the patella/femorla joint, and cartilage wear. Due to the patient's anxious posture, it caused a shaking image, overlapping structures, and etcs, these factors challenge to diagnose accurately. In addition, the existing Settegast method and Hughston method, which are most frequently performed in the hospital field, are not suitable for the presence or absence of features or dislocation due to the heavy load on the patella of the patient. The developed device requires patients in a lying position and placing only their leg on the device, it increases the conveniences of the examination and decreases unnecessary radiation exposure of the patient except the patellar examination area. Moreover, one of the systems in the device fixes the detector, where the patients no longer need to hold the detector nor be in unstable posture, but describes the structure of the patella/femoral joint more clearly. Hoping the device will apply to more patients.

금속펄스 선형증폭기의 빠른 입력펄스에 대한 이득안정도에 관한 연구 (Sinusoidal A Study on the gain Stability of the Feedback Linear Pulse Amplifiers for Fast Pulse Input)

  • 이병선
    • 대한전자공학회논문지
    • /
    • 제11권3호
    • /
    • pp.1-14
    • /
    • 1974
  • 귀환 펄스 선형증폭기에 단계전압과 방사능검출기에서 나오는 펄스 전압이 인가되었때 경우의 이득안정도에 관하여 해석검토 하였다. 방사능 검출기의 일부를 이루고 있는 광전증배관의 양극회로에서 형성되는 파형을 나타내는 식을 유도 하였으며 귀환 증폭기가 하나의 시정수와 두 개의 시정수를 가졌을 경우에 관하여 해석하였고 이 들을 비교 검토하였다. 이들 빠른 입력펄스전압이 귀환증폭기에 인가되면 출력전압의 선형도와 안정도는 증폭기의 rise time와, 2∼3배가 경과하여야 귀환효과가 나타난다. 이 제한을 줄이기 위하여는 귀환증폭기의 rise time을 계측할려는 입력 펄스의 폭보다 적도록 설계하여야 한다는 것을 증명하였다. 이상의 이론은 선형증폭기의 기본증폭단으로 설계된 고렬전압 귀환증폭단에도 그대로 적용굴을 보였으며 이 증폭단의 입력저항이 적을수록 이득안정도가 좋아짐을 보였다.

  • PDF