• Title/Summary/Keyword: radiation detector

Search Result 842, Processing Time 0.025 seconds

Adaptive Tracking Algorithm Based on Direction Field for Automated Identification of Vessel Contour (혈관 윤곽의 자동적 식별을 위한 방향성 기반의 적응적 추적 알고리즘)

  • Park, S.I.;Lee, J.S.;Koo, J.Y.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.414-417
    • /
    • 1997
  • This paper presents vessel contour for extracting features and segmentating narrow blood vessels down to a diameter of two pixels in digital subtraction angiographic image. We present a new tracking algorithm for contour, mainly blood vessels in DSA image, and extracting properties such as their intensities, diameters, and center lines by exploiting spatial continuity. The proposed algorithm comes to detect blood vessel's boundary using difference edge detector one of homogeneity operator and find a next centerline position by direction vector of edge information. This algorithm enhanced variation of vessel's diameter compared to Sun's tracking algorithm and lessoned to compute as direction vector decide adaptively entire vessel's direction field. The processed images are intended to support radiologists in diagnosis, radiation therapy planning, and surgical planning. The algorithm should be useful for automating angiographic analyses of blood vessels.

  • PDF

Synthesis and Molecular Structure of p-tert-butylcalix[4]arene Hexanoate

  • Park, Young-Ja;Kwanghyun No;Cho, Sun-Hee
    • Korean Journal of Crystallography
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 1999
  • Two conformational isomers of p-tert-butylcalix[4]arene hexanoate were prepared from the reaction of-p-tert-butylcalix[4]arene and hexanoly chloride in the presence of AlCl3 in CH2Cl2 and their structures were determined by NMR spectra and X-ray diffraction as a cone and a 1,3-alternate conformer, respectively. The crystal of cone conformer (C68H96O8·(CH3)2CO) is triclinic, P, a=15.066(1) , b=16.063(1) , c=16.365(1) , α=79.75(2)o, β=109.95(2)o, γ=80.32(0)o, V=3602.7(4) 3, Z=2. The intensity data were collected on Simens SMART diffractometer/CCD area detector. The structure was solved by direct method and refined by least-squares calculations to a final R value of 0.144 for 4638 observed reflections. The molecular conformation is distorted symmetric cone with the flattening A and D phenyl rings. The crystal of 1,3-alternate conformer (C68H96O8·2CHCl3) is orthorhombic, Pca21, a=34.586(5) , b=10.207(3) , c=20.394(4) , V=7199(3) 3, Z=4. The intensity data were collected on an Enraf-Noninus CAD-4 Diffractometer with a graphite monochromated Mo-K radiation. The structure was solved by direct method and refined by least-squares calculations to a final R value of 0.152 for 2241 observed reflections. The molecule has a pseudo mirror symmetric 1,3-alternate conformation.

  • PDF

3D CACT-assisted Radiofrequency Ablation Following Transarterial Chemoembolization for Hepatocellular Carcinoma: Early Experience

  • Jiao, De-Chao;Han, Xin-Wei;Wu, Gang;Ren, Jian-Zhuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7897-7903
    • /
    • 2015
  • Background: To explored the value of 3D C-arm CT (CACT) guidance system in performing radiofrequency ablation (RFA) following transarterial chemoembolizationon (TACE) for hepatocellular carcinomas. Materials and Methods: RFA of hepatocellular carcinomas (HCC) were performed on 15 patients (21 lesions) with the assistance of CACT guidance system. Technical success, procedure time, complications and patient radiation exposure were investigated. The puncture performance level was evaluated on a five-point scale (5-1: excellent-poor). Complete ablation rate was evaluated after two months follow-up using enhanced CT scans. Results: The technical success rate of RFA procedure under CACT navigation system was 100 %. Mean total procedure time was $24.24{\pm}6.53min$, resulting in a mean effective exposure dose of $15.4{\pm}5.1mSv$. The mean puncture performance level rated for CACT guided RFA procedure was $4.87{\pm}0.35$. Complete ablation (CA) was achieved in 20 (95.2%) of the treated 21 tumors after the first RFA session. None of patients developed intra-procedural complications. Conclusions: 3D CACT guidance system enables reliable and efficient needle positioning by providing real-time intraoperative guidance for performing RFA on HCCs.

The Effective Image Diagnosis Using Curved MPR from MDCT (MDCT에서 Curved MPR을 이용한 효과적인 영상진단)

  • Song, Jong-Nam;Jang, Yeong-Ill
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.139-143
    • /
    • 2010
  • Two-dimensional(2D) images like Multi Planar Reconstruction(MPR) Image or Maximum Intensity Projection(MIP) were used for the purpose of diagnosis, but MPR image's quality were limited due to its superior limit of Z-axis ability to produce permitted radiation exposure virtuous in the permitted time limit from the existing Spiral CT. However, in company with the development of the Multi Detector Computed Tomography(MDCT), we were able to get the Data with the equal amount of Voxel, also get varied reconstructions as in the aspect of our needs. This present study propose a reconstruction technique which is to extract a field using Region of interest(ROI) segmentation method for improvement of the quality of the medical image and after that reconstruct the concerned part using the four-directed symmetry method of the oval, than using the reconstructed data, reorganize the image by using the Curved MPR method. If current proposed method is used, it is highly effective because of its ability to accurately display the disease concerned part, which will reduce the decoding time and also effectively provide information based on the accuracy of the decode.

  • PDF

Space Physics Sensor on KOMPSAT-1

  • Min, Kyoung-Wook;Choi, Young-Wan;Shin, Young-Hoon;Lee, Jae-Jin;Lee, Dae-Hee;Kim, Jhoon
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.355-360
    • /
    • 1998
  • A small package of plasma instruments, Space Physics Sensor, will monitor the space environment and its effects on microelectronics in the low altitude region as it operates on board the KOMPSAT-1 from 1999 over the maximum of the solar cycle 23. The Space Physics Sensor (SPS) consists of two parts: the Ionospheric Measurement Sensor (IMS) and the High Energy Particle Detector (HEPD). IMS will make in situ Measurements of the thermal electron density and temperature, and is expected to provide a global map of the thermal electron characteristics and the variability according to the solar and geomagnetic activity in the high altitude ionosphere of the KOMPSAT-t orbit. HEPD will measure the fluxes of high energy protons and electrons, monitor the single event upsets caused by these energetic charged particles, and give the information of the total radiation dose received by the spacecraft. The continuous operation of these sensors, along with the ground measurements such as incoherent scatter radars, digital ionosondes and other spacecraft measurements, will enhance our understanding of this important region of practical use for the low earth orbit satellites.

  • PDF

Elemental analysis by neutron induced nuclear reaction - Nuclear track method for the analysis of fissile materials

  • Ha, Yeong-Keong;Pyo, Hyung Yeol;Park, Yong Joon;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.263-270
    • /
    • 2005
  • Nuclear track is an useful tool for elemental analysis of radionuclides, such as uranium, plutonium and thorium, etc., and for elements undergoing nuclear reactions with thermal neutrons such as lithium and boron. This method has various application fields such as detecting fissionable radionuelides, measuring the fission rate in nuclear technology, analyzing cosmic radiation from meteorite, calculating the age of minerals as well as their history, etc. Track registration method has been applied to the microscopic analysis of boron and fissionable element such as uranium in KAERI. This report reviews the theoretical background of the nuclear track formation, practical procedures to obtain etched tracks and a perspective of the future.

Development of Children's X-ray Imaging Assist Device (어린이 방사선검사 보조기구의 개발)

  • Rhee, Do-Byung;Seo, Seung-Jun;Choi, Hyun-Woo;Ko, Cheol-Woo;Kim, Jong-Ki
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.243-249
    • /
    • 2020
  • Examination with medical radiography is the most significant advances in medicine in the 21st century. Diagnostic imaging occupies an important position in all medical subjects, surgical and internal medicine, including radiology, orthopedics, and neurosurgery. However, the invention associated with conventional radiography devices has focused only on emphasizing the efficient aspects of the examination or obtaining clearer images without considering the age and disease-induced constraints of the patient's posture. The newly developed X-ray aids to solve this problem can effectively perform X-ray imaging of children's who have difficulty communicating and controlling. It is also thought to be a good way to provide accurate imaging information and minimize radiation exposure for children.

Determination of some useful radiation interaction parameters for waste foods

  • Akman, F.;Gecibesler, I.H.;Sayyed, M.I.;Tijani, S.A.;Tufekci, A.R.;Demirtas, I.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.944-949
    • /
    • 2018
  • The mass attenuation coefficients (${\mu}/{\rho}$) of food waste samples (pomegranate peel, acorn cap, lemon peel, mandarin peel, pumpkin peel, grape peel, orange peel, pineapple peel, acorn peel and grape stalk) have been measured employing a Si(Li) detector at 13.92, 17.75, 20.78, 26.34 and 59.54 keV. Also, the theoretical values of the mass attenuation coefficients have been evaluated utilizing mixture rule from WinXCOM program. The results showed that the lemon peel has the highest values of ${\mu}/{\rho}$ among the selected samples. From the obtained mass attenuation coefficients, we determined some absorption parameters such as effective atomic number ($Z_{eff}$), electron density ($N_E$) and molar extinction coefficient (${\varepsilon}$). It was found that the $Z_{eff}$ values of all food wastes lie within the range of 4.034-7.595, whereas the $N_E$ of the studied food wastes was found to be in the range of $0.301-1.720{\times}10^{25}$ (electrons/g) for present energy region.

Comparison of theoretical and machine learning models to estimate gamma ray source positions using plastic scintillating optical fiber detector

  • Kim, Jinhong;Kim, Seunghyeon;Song, Siwon;Park, Jae Hyung;Kim, Jin Ho;Lim, Taeseob;Pyeon, Cheol Ho;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3431-3437
    • /
    • 2021
  • In this study, one-dimensional gamma ray source positions are estimated using a plastic scintillating optical fiber, two photon counters and via data processing with a machine learning algorithm. A nonlinear regression algorithm is used to construct a machine learning model for the position estimation of radioactive sources. The position estimation results of radioactive sources using machine learning are compared with the theoretical position estimation results based on the same measured data. Various tests at the source positions are conducted to determine the improvement in the accuracy of source position estimation. In addition, an evaluation is performed to compare the change in accuracy when varying the number of training datasets. The proposed one-dimensional gamma ray source position estimation system with plastic scintillating fiber using machine learning algorithm can be used as radioactive leakage scanners at disposal sites.

High rate diffusion-scale approximation for counters with extendable dead time

  • Dubi, Chen;Atar, Rami
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1616-1625
    • /
    • 2019
  • Measuring occurrence times of random events, aimed to determine the statistical properties of the governing stochastic process, is a basic topic in science and engineering, and has been the subject of numerous mathematical modeling approaches. Often, true statistical properties deviate from measured properties due to the so called dead time phenomenon, where for a certain time period following detection, the detection system is not operational. Understanding the dead time effect is especially important in radiation measurements, often characterized by high count rates and a non-reducible detector dead time (originating in the physics of particle detection). The effect of dead time can be interpreted as a suitable rarefied sequence of the original time sequence. This paper provides a limit theorem for a high rate (diffusion-scale) counter with extendable (Type II) dead time, where the underlying counting process is a renewal process with finite second moment for the inter-event distribution. The results are very general, in the sense that they refer to a general inter arrival time and a random dead time with general distribution. Following the theoretical results, we will demonstrate the applicability of the results in three applications: serially connected components, multiplicity counting and measurements of aerosol spatial distribution.