• Title/Summary/Keyword: radiation detector

Search Result 842, Processing Time 0.024 seconds

The development of photo-diode dosimeter(PD-2000) for the diagnostic X-ray Energy (X선 진단영역 에너지 측정을 위한 Photo-Diode 선량계(PD-2000)의 개발)

  • Kim, Sung-Chul;Lee, Woo-Chul;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.27-32
    • /
    • 2000
  • It was produced radiation dosimeter used photo-diodes for which ionization by x-ray was applied and evaluated the value of utility in clinics as compared with ion-chamber. The result obtained were as follows : 1. Comparison of ion-chamber with photo-diode dosimeter's x-ray output by the change of x-ray tube voltage, and the ratio of ion-chamber to diode was $0.96{\sim}1.02$ which was not affected by x-ray beam quality. 2. The ratio of ion-chamber to diode was 0.96 by change of tube current and 0.97 by change of exposure time that is not affected by x-ray quantity. 3. The ratio of ion-chamber to diode was $0.97{\sim}1.04$ by thickness and $0.93{\sim}1.10$ by radiation field that is little affected by second ray quantity. 4. Reproducibility of photo-diode dosimeter was 0.011(CV) and it is a good result. 5. Photo-diode dosimeter was affected by the surface angle of detector over 30 degrees. Produced dosimeter was small, light, and meets good result compared with ionization chamber. It was expected come into wide use in clinic.

  • PDF

On the Etching Condition of Cellulose Nitrate Solid State Nuclear Track Detector (SSNTD) (Cellulose Nitrate 고체비적검출기(固體飛跡檢出器)의 부식조건(腐蝕條件))

  • Myung, Dong-Bum;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.26-33
    • /
    • 1987
  • An experimental study for an optimum etching of commercialized cellulose nitrate SSNTD, CA 80-15 and LR 115-1 for detecting alpha particles, was carried out. Alt-hough ordinary etching condition of the detectors has been recommended by the producer, a remarkable discrepancy in etching tine was found. The detectors were irradiated with a $0.1{\mu}Ci\;^{241}Am$ alpha source under a known geometrical arrangement. Analysis on the track size as functions of etching time and etchant concentration and comparative examination of theoretically predicted number of tracks per unit area with that recorded on the detectors were made, including a study on the variation of detection efficiency with the effective energy of the incident alpha particles.

  • PDF

AN IV CATHETER FRAGMENTS DURING MDCT SCANNING OF HUMAN ERROR: EXPERIMENTAL AND REPRODUCIBLE MICROSCOPIC MAGNIFICATION ANALYSIS

  • Kweon, Dae-Cheol;Lee, Jong-Woong;Choi, Ji-Won;Yang, Sung-Hwan;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.195-199
    • /
    • 2011
  • The use of intravenous catheters are occasionally complicated by intravascular fragments and swelling of the catheter fragments. We present a patient in whom an intravenous catheter fragments was retrieved from the dorsal metacarpal vein following its incidental CT examination detection. The case of demonstrates the utility of microscopy and multi-detector CT in localizing small of subtle intravenous catheter fragments as a human error. A case of IV catheter fragments in the metacarpal vein, in which reproducible and microscopy data allowed complete localization of a missing fragments and guided surgery with respect to the optimal incision site for fragments removal. These reproducible studies may help to determine the best course of action and treatment for the patient who presents with such a case.

Experimental Investigation of Clay Fly Ash Bricks for Gamma-Ray Shielding

  • Mann, Harjinder Singh;Brar, Gurdarshan Singh;Mann, Kulwinder Singh;Mudahar, Gurmel Singh
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1230-1236
    • /
    • 2016
  • This study aims to determine the effect of fly ash with a high replacing ratio of clay on the radiation shielding properties of bricks. Some interaction parameters (mass attenuation coefficients, half value layer, effective atomic number, effective electron density, and absorption efficiency) of clay fly ash bricks were measured with a NaI(Tl) detector at 661.6 keV, 1,173.2 keV, and 1,332.5 keV. For the investigation of their shielding behavior, fly ash bricks were molded using an admixture to clay. A narrow beam transmission geometry condition was used for the measurements. The measured values of these parameters were found in good agreement with the theoretical calculations. The elemental compositions of the clay fly ash bricks were analyzed by using an energy dispersive X-ray fluorescence spectrometer. At selected energies the values of the effective atomic numbers and effective electron densities showed a very modest variation with the composition of the fly ash. This seems to be due to the similarity of their elemental compositions. The obtained results were also compared with concrete, in order to study the effect of fly ash content on the radiation shielding properties of clay fly ash bricks. The clay fly ash bricks showed good shielding properties for moderate energy gamma rays. Therefore, these bricks are feasible and eco-friendly compared with traditional clay bricks used for construction.

Study of photon beam quality tool at magnetic field change in bending magnet (편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰)

  • Kim, Jeong-Ho;Yoo, Se-Jong;Park, Myeong-Cheol;Bae, Seok-Hwan;Kim, Ki-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.

Monte Carlo simulation of the electronic portal imaging device using GATE

  • Chung, Yong-Hyun;Baek, Cheol-Ha;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.11-16
    • /
    • 2007
  • In this study, the potential of a newly developed simulation toolkit, GATE for the simulation of electronic portal imaging devices (EPID) in radiation therapy was evaluated by characterizing the performance of the metal plate/phosphor screen detector for EPID. We compared the performances of the GATE simulator against MCNP4B code and experimental data obtained with the EPID system in order to validate its use for radiation therapy.

  • PDF

Counting Strategies in Radioactivity Measurement for the Monitoring and Screening (방사능 존재확인과 정량분석시 최적화된 측정시간의 결정을 위한 계측전략)

  • Seo, Kyung-Won
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • One of the important things in low level radioactivity measurement is determination of the optimized counting time. Counting strategy has to be established, in order to count the radioactivity of the sample by condition of optimized measurement. There were three kinds of counting strategies in this report ; about fixed time, about fixed count, to compared sample, background, and reference level. The best of them was satisfied rendition to give about condition of instrument and process, as an example, efficiency of detector, counter capacity, maximum and average background count rate of counter, reference level and limit of derision and detection, etc. Therefore, we can decide the optimized counting time in the screening and monitoring. And we can save the time for courting the sample of course the data of count will be counted by optimized accuracy finally, in rountine measurement of radioactivity these strategies will be used available.

  • PDF

A Field Tracer Experiment by Using a Radioisotope near the Offshore (동위원소를 이용한 연안역 현장실험)

  • Kim, Ki Chul;Park, Geon Hyeong;Lee, Jin Yong;Jung, Sung Hee;Min, Byung Il;Suh, Kyung Suk
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.41-47
    • /
    • 2012
  • A field tracer experiment using a radioisotope was conducted to analyze the transport and dispersion characteristics of pollutants in the coastal area near a Wolsung. A rod float including GPS was released to track the paths of radioisotope. NaI detector was installed to measure the released radioisotope from the boat, and measurements were performed with the real time. The measured tracer data by a field experiment can be used as the basic data for understanding the transport characteristics of pollutants and verifying numerical models near the offshore.

Measurement of Flow Characteristics of Digester Installed Tray Motioned Mixer by Using Radiotracer (방사성추적자를 이용한 수직교반형 소화조의 유동 특성 측정)

  • Moon, Jinho;Park, Jang Guen;Kang, Munhu;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.131-135
    • /
    • 2015
  • The flow characteristics of fluid were measured using radioactive tracer in pilot scale digester with tray motion mixer. In consideration of the detection volume of the detector and the size of the digester, 20 detectors were installed in the digester. The radioactive tracer eluted 8 mCi of $^{68}Ga$ from $^{68}Ge/^{68}Ga$ generator was injected into the digester bottom. After radiotracer injection, the flow pattern was measured on the basis of the initial movement of the tracer until its diffusion completely. Most of tracer moved to the wall along the bottom of the digester, and then rose along the wall. The other tracer moved up along the mixer, and then moved to the wall direction along the surface.

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.