• Title/Summary/Keyword: radiation detection

Search Result 767, Processing Time 0.031 seconds

Study on the Effectiveness of some Decontamination Agents against Skin Contamination of $^{137}Cs$ and $^{60}Co$ (제염제의 $^{137}Cs$$^{60}Co$에 의한 피부오염의 제염효과에 관한 연구)

  • Chon, Je-Keun;Ji, Pyung-Kook;Kwak, Sang-Soo;Kim, Byung-Tae;Park, Chong-Mook
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.7-15
    • /
    • 1998
  • In order to evaluate the effectiveness of some decontamination agents against skin contamination of $^{60}Co$ and $^{137}Cs$, the experiments were carried out in this study. In the experiments, pig skin was used instead of human skin , $^{60}CoC1_2$ and $^{137}CsCl$ were used the liquid sources of skin contamination. To examine the effectiveness of decontamination agents, skin decontamination was tried using soup, EDTA, KAERICON which was developed for decontamination of radionulides on the surface of building structure, and new decontamination agents such as IOCON, TRICON, and CHARCON, which were developed in this study. The absorption of radionuclides through the skin was evaluated by the gamma-tay detection on the surface of sample skin after radionuclides were penetrated into the skin during 16 hour soiling time. The results of this absorption experiment indicated that 11.5% and 3.2% of initial amounts of $^{137}Cs$ and $^{60}Co$, respectively, were panerated into the skin. In the experiment to remove the residual radioactivity fixed on the skin, KAERICON showed the decontamination rates up to 52.1%(decontamination factor of 2.1) and IOCON showed the equivalent decontamination rate (decontamination factor 1.9) for $^{137}Cs$. However, IOCON and CHARCON showed the poor decontamination rates of less than 20%(decontamination factor of 1.2) for $^{60}Co$, and KAERICON showed the poor decontamination rate (decontamination factor 1.1) for $^{60}Co$. For TRICON, the decontamination factors were 1.6 to 1.8 for $^{137}Cs$, and 1.0 to 1.2 for $^{60}Co$, respectively.

  • PDF

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Magnetic Resonance Voiding Cystography in the Diagnosis of Vesicoureteral Reflux: Comparative Study with Voiding Cystourethrography (방광요관역류의 진단에 있어서 자기공명 배뇨성 방광조영술의 유용성: 태뇨성 요도방광조영술과의 비교연구)

  • Lee, Sang-Kwon;Chang, Yong-Min;Koo, Ja-Hoon;Ko, Cheol-Woo;Chung, Sung-Kwang;Kim, Tae-Hun;Sohn, Kyung-Sik;Lee, Chang-Hyun;Kim, Young-Hwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.85-93
    • /
    • 2000
  • Purpose: To evaluate the availability of magnetic resonance (MRI voiding cystography for the diagnosis of vesicoureteral reflux (VUR) and to compare the sensitivity of MR voiding cystography (MRVC) with that of radiographic voiding cystourethrography (VCUG) in the detection of VUR. Material and Methods : MRVC was performed upon 20 children referred for investigation of VUR. Either coronal T1-weighted spin-echo or spoiled gradient-echo images were obtained before and after transurethral administration of a mixture of normal saline and gadopentetate dimeglumine, and immediately after voiding. The findings of MRVC were compared with those of VCUG performed within 6 months of MRVC. Results 1 VUR was detected in 23 ureterorenal units f16 VUR's by both methods, five VUR's by VCUG, and two VUR's by MRVC). The sensitivity of VCUG and MRVC in detecting VUR was 91.3% (21/23) and 78.3% (18/23), respectively. MRVC detected renal scarring in 15 out of 17 kidneys with scintigraphically detected renal scarring. Conclusion : Although MRVC is slightly less sensitive than VCUG in the detection of VUR, it can be used for the diagnosis of VUR and renal scarring simultaneouslyl and thus will reduce the radiation hazard.

  • PDF

Nuclear Terrorism and Global Initiative to Combat Nuclear Terrorism(GICNT): Threats, Responses and Implications for Korea (핵테러리즘과 세계핵테러방지구상(GICNT): 위협, 대응 및 한국에 대한 함의)

  • Yoon, Tae-Young
    • Korean Security Journal
    • /
    • no.26
    • /
    • pp.29-58
    • /
    • 2011
  • Since 11 September 2001, warnings of risk in the nexus of terrorism and nuclear weapons and materials which poses one of the gravest threats to the international community have continued. The purpose of this study is to analyze the aim, principles, characteristics, activities, impediments to progress and developmental recommendation of the Global Initiative to Combat Nuclear Terrorism(GICNT). In addition, it suggests implications of the GICNT for the ROK policy. International community will need a comprehensive strategy with four key elements to accomplish the GICNT: (1) securing and reducing nuclear stockpiles around the world, (2) countering terrorist nuclear plots, (3) preventing and deterring state transfers of nuclear weapons or materials to terrorists, (4) interdicting nuclear smuggling. Moreover, other steps should be taken to build the needed sense of urgency, including: (1) analysis and assessment through joint threat briefing for real nuclear threat possibility, (2) nuclear terrorism exercises, (3) fast-paced nuclear security reviews, (4) realistic testing of nuclear security performance to defeat insider or outsider threats, (5) preparing shared database of threats and incidents. As for the ROK, main concerns are transfer of North Korea's nuclear weapons, materials and technology to international terror groups and attacks on nuclear facilities and uses of nuclear devices. As the 5th nuclear country, the ROK has strengthened systems of physical protection and nuclear counterterrorism based on the international conventions. In order to comprehensive and effective prevention of nuclear terrorism, the ROK has to strengthen nuclear detection instruments and mobile radiation monitoring system in airports, ports, road networks, and national critical infrastructures. Furthermore, it has to draw up effective crisis management manual and prepare nuclear counterterrorism exercises and operational postures. The fundamental key to the prevention, detection and response to nuclear terrorism which leads to catastrophic impacts is to establish not only domestic law, institution and systems, but also strengthen international cooperation.

  • PDF

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

Detection of irradiated food using photostimulated luminescence and thermoluminescence (물리적 방법(PSL, TL)을 이용한 선종별 조사처리 식품의 검지 특성)

  • Jung, Yoo-Kyung;Lee, Ji-Yeon;Kang, Tae-Sun;Jo, Cheon-Ho;Lee, Jae-Hwang;Choi, Jang-Duck;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.399-404
    • /
    • 2016
  • The applicability of photostimulated-luminescence (PSL) and thermoluminescence (TL) for the detection of 12 food materials (potato, onion, garlic, dried pumpkin, black mushroom, black soybean, Cheongkukjang powder, sea mustard, pepper powder, Ramyun soup, corn tea, and green tea powder) irradiated with an electron beam, gamma ray, and X ray at a range of 0.15 to 10 kGy was investigated. For PSL, negative results (less than 700 photon counts (PCs)) were observed from non-irradiated foods while the irradiated foods showed intermediate (879 to 2,414 PCs) and/or positive (19,951 to 65,919,035 PCs) values. In all irradiated samples, the maximum peak of the TL glow curve was observed between 150 and $250^{\circ}C$. Our findings demonstrate the successful application of PSL and TL to determine whether food items were irradiated or not. However, there were no significant differences among the radiation sources.

RELIABILITY OF SPIRAL TOMOGRAPHY FOR IMPLANT SITE MEASUREMENT OF THE MANDIBLE (하악골 매식 부위 계측을 위한 나선형 단층촬영술의 신뢰도)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.27-47
    • /
    • 1997
  • The purpose of this study was to evaluate the accuracy and usefulness of spiral tomography through the comparison and analysis of SCANORA cross-sectional tomographs and DentaScan computed tomographic images of dry mandibles taken by a SCANORA spiral tomographic machine and a computed tomographic machine. Thirty-one dry mandibles with full or partial edentulous areas were used. To evaluate the possible effect of location in the edentulous area, it was divided into 4 regions of Me (region of mental foramen), MI (the midportion between Me and M2), M2 (the midportion between mental foramen and mandibular foramen) and S (the midportion of the mandibular symphysis). A ZPC column (sized 4 mm x 5 mm) was seated on the edentulous regions of Me, MI, M2 and S using the acrylic stent. Then SCANORA spiral tomography and computed tomography were taken on the edentulous regions which contained the ZPC column. The ZPC columns and cross-sectional images of the mandible were measured in the radiographs by three observers and the differences between the two imaging modalities were analysed. The results were as follows: 1. In comparing the actual measurements of the ZPC column and measurements in the radiographs, the mean error of the DentaScan computed tomography was 0.07 mm in vertical direction and -0.06 mm in horiwntal direction, while the mean error of the SCANORA spiral tomography was 0.06 mm in vertical direction and -0.12 mm in horizontal direction. There was a significant difference between the two radiographic techniques in the horizontal measurement of the ZPC column of the symphysis region (p<0.05). But there was no significant difference in the measurements of other regions (p>0.05). 2. In measurements of the distance from the alveolar crest to the inferior border of the mandible (H), and of the distance from the alveolar crest to the superior border of the mandibular canal (Y), there was no significant difference between the two radiographic techniques (p>0.05). 3. In measurements of the distance from the lingual border of the mandible to the buccal border of the mandible (W), and of the distance from the lingual border of the mandible to the lingual border of the mandibular canal (X), there was a significant difference between the two radiographic techniques in measurements of the midportion between the mental foramen and the mandibular foramen (M2) (p<0.05). But there were no significant differences in measurements of the other regions of symphysis (S), mental foramen (Me), the first one-fourth portion between the mental foramen and the mandibular foramen (M1) (p>0.05). 4. Considering the mean range of measurements between observers, the measurements of SCANORA spiral tomography showed higher value than those of DentaScan computed tomography, except in measurements of symphysis (S). 5. On the detectability of the mandibular canal, there was no significant difference between the two radiographic techniques (p>0.05). In conclusion, SCANORA spiral tomography demonstrated a higher interobserver variance than that of DentaScan computed tomography for implant site measurements in the posterior edentulous area of the mandible. These differences were mainly the result of difficulty in the detection of the border of the mandible in SCANORA spiral tomography. But considering the cost and the radiation exposure, SCANORA spiral tomography can be said to be a relatively good radiographic technique for implant site measurement.

  • PDF

Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube (다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발)

  • Kwon, Sun-Il;Hong, Seong-Jong;Ito, Mikiko;Yoon, Hyun-Suk;Lee, Geon-Song;Sim, Kwang-Souk;Rhee, June-Tak;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Purpose: The goal of this paper is to present the design and performance of a position encoding circuit for $16{\times}16$ array of position sensitive multi-anode photomultiplier tube for small animal PET scanners. This circuit which reduces the number of readout channels from 256 to 4 channels is based on a charge division method utilizing a resistor array. Materials and Methods: The position encoding circuit was simulated with PSpice before fabrication. The position encoding circuit reads out the signals from H9500 flat panel PMTs (Hamamatsu Photonics K.K., Japan) on which $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ ($Lu_{1.8}Gd_{0.2}SiO_{5}:Ce$) crystals were mounted. For coincidence detection, two different PET modules were used. One PET module consisted of a $29{\times}29\;L_{0.9}GSO$ crystal layer, and the other PET module two $28{\times}28$ and $29{\times}29\;L_{0.9}GSO$ crystal layers which have relative offsets by half a crystal pitch in x- and y-directions. The crystal mapping algorithm was also developed to identify crystals. Results: Each crystal was clearly visible in flood images. The crystal identification capability was enhanced further by changing the values of resistors near the edge of the resistor array. Energy resolutions of individual crystal were about 11.6%(SD 1.6). The flood images were segmented well with the proposed crystal mapping algorithm. Conclusion: The position encoding circuit resulted in a clear separation of crystals and sufficient energy resolutions with H9500 flat-panel PMT and $L_{0.9}GSO$ crystals. This circuit is good enough for use in small animal PET scanners.

Bilateral retinoblastoma: Long-term follow-up results from a single institution (단일기관의 장기추적 결과)

  • Choi, Sang Yul;Kim, Dong Hwan;Lee, Kang Min;Lee, Hyun Jae;Kim, Mi-Sook;Lee, Tai-Won;Choi, Sang Wook;Kim, Dong Ho;Park, Kyung Duk;Lee, Jun Ah
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.6
    • /
    • pp.674-679
    • /
    • 2009
  • Purpose : The authors aimed to analyze the long-term effects of treatments, especially external beam radiotherapy (EBRT), in bilateral retinoblastoma patients. Methods : This retrospective study analyzed the medical records of 22 bilateral retinoblastoma patients who were registered between October, 1987 and October, 1998 and followed-up for more than 10 years. They were treated by enucleation, EBRT, and systemic chemotherapy. Age at diagnosis, sex, delay prior to treatment, Reese-Ellsworth (RE) classification, and the local treatment modalities were analyzed in relation to recurrence-free survival (RFS) and complications. Results : Median age at diagnosis was 7.0 months (range 1.7-31.6 months). Leukocoria was the most common presenting feature. Two patients had a familial history. The RE classifications of the 44 eyes were group II in 4, III in 14, IV in 4, and V in 22. At the end of a median follow-up period of 141 months (range 55-218 months), 20 patients were alive. The 10-year ocular survival rate of the 44 eyes was $56.8{\pm}7.5%$. The 10-year RFS and ocular survival rate of the 29 eyes treated by combined EBRT and chemotherapy were 75.9% and 86.2%, respectively. Treatment delay (>3 months) was found to be related to higher risk of recurrence. Complications after EBRT were cataract, retinal detachment, phthisis bulbi, and facial asymmetry. No patient developed a second malignancy during the follow-up period. Conclusion : Early detection and prompt treatment can increase ocular survival rates. In addition, careful attention should be paid to possible long-term sequelae in these patients.

Current Status and Future Perspective of PET (PET 이용 현황 및 전망)

  • Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) defecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3,015 and 4,414 in 1996,1997,1998,1999 and 2000, respectively. The application in cardiac disorders is minimal, and among various neuropsychiatric diseases, patients with epilepsy or dementia can benefit from PET studios. Recently, we investigated brain mapping and neuroreceptor works. PET is not a key application for evaluation of the cardiac patients in Korea because of the relatively low incidence of cardiac disease and less costly procedures such as SPECT can now be performed. The changes in the application of PET studios indicate that, initially, brain PET occupied almost 60% in 1995, followed by a gradual decrease in brain application. However, overall PET use in the diagnosis and management of patients with cancer was up to 63% in 2000. The current medicare coverage policy in the USA is very important because reimbursement policy is critical for the promotion of PET. In May 1995, the Health Care Financing Administration (HCFA) began covering the PET perfusion study using Rubidium-82, evaluation of a solitary pulmonary nodule and pathologically proven non-small cell lung cancer. As of July 1999, Medicare's coverage policy expanded to include additional indications: evaluation of recurrent colorectal cancer with a rising CEA level, staging of lymphoma and detection of recurrent or metastatic melanoma. In December of 2001, National Coverage decided to expand Medicare reimbursement for broad use in 6 cancers: lung, colorecctal, lymphoma, melanoma, head and neck, and esophageal cancers; for determining revascularization in heart diseases; and for identifying epilepsy patients. In addition, PET coverage is expected to further expand to diseases affecting women, such as breast, ovarian, uterine and vaginal cancers as well as diseases like prostate cancer and Alzheimer's disease.