• 제목/요약/키워드: radiation attenuation

검색결과 267건 처리시간 0.023초

Atmospheric Correction of Sentinel-2 Images Using Enhanced AOD Information

  • Kim, Seoyeon;Lee, Yangwon
    • 대한원격탐사학회지
    • /
    • 제38권1호
    • /
    • pp.83-101
    • /
    • 2022
  • Accurate atmospheric correction is essential for the analysis of land surface and environmental monitoring. Aerosol optical depth (AOD) information is particularly important in atmospheric correction because the radiation attenuation by Mie scattering makes the differences between the radiation calculated at the satellite sensor and the radiation measured at the land surface. Thus, it is necessary to use high-quality AOD data for an appropriate atmospheric correction of high-resolution satellite images. In this study, we examined the Second Simulation of a Satellite Signal in the Solar Spectrum (6S)-based atmospheric correction results for the Sentinel-2 images in South Korea using raster AOD (MODIS) and single-point AOD (AERONET). The 6S result was overall agreed with the Sentinel-2 level 2 data. Moreover, using raster AOD showed better performance than using single-point AOD. The atmospheric correction using the single-point AOD yielded some inappropriate values for forest and water pixels, where as the atmospheric correction using raster AOD produced stable and natural patterns in accordance with the land cover map. Also, the Sentinel-2 normalized difference vegetation index (NDVI) after the 6S correction had similar patterns to the up scaled drone NDVI, although Sentinel-2 NDVI had relatively low values. Also, the spatial distribution of both images seemed very similar for growing and harvest seasons. Future work will be necessary to make efforts for the gap-filling of AOD data and an accurate bi-directional reflectance distribution function (BRDF) model for high-resolution atmospheric correction. These methods can help improve the land surface monitoring using the future Compact Advanced Satellite 500 in South Korea.

콘크리트 댐 내진성능평가 시 감쇠비 적용 방안 고찰 (Study on the Application of Damping Ratio in the Seismic Performance Evaluation of Concrete Dams)

  • 오정근;정영석;권민호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권1호
    • /
    • pp.9-18
    • /
    • 2023
  • 이 논문의 목적은 콘크리트 댐의 내진성능평가 시 현행 설계기준과 평가요령에서 제시하는 감쇠비 값 크기에 대한 적용방안의 적정성을 검토하고 개선안을 제시하는 것이다. 연구결과 동적탄성해석 시 감쇠비의 크기는 지진하중의 크기가 유사하고 감쇠비에 대한 재현성이 검증된 유사댐의 사례를 참조할 필요가 있으며, 동적소성해석 시에는 지진하중의 크기와 상관없이 초기 탄성거동을 고려하여 감쇠비를 낮은값으로 적용하고 비선형 거동 시 이력감쇠가 추가되도록 고려할 필요가 있다. 또한 암반상에 위치한 콘크리트 댐체는 방사감쇠 효과가 미미하므로 방사감쇠를 반영하기 위해 콘크리트 댐체의 감쇠비를 증가시키는 것은 합리적이지 않다. 따라서 콘크리트 댐의 현실적인 내진성능평가를 위해 현행 댐 설계기준과 평가요령에 수록된 감쇠비 관련내용에 대해 개정이 필요하다.

수중 위치 추정을 위한 3차원 전자기파 센서 노드 개발 (Development of 3-Dimensional Sensor Nodes using Electro-magnetic Waves for Underwater Localization)

  • 곽경민;김진현
    • 제어로봇시스템학회논문지
    • /
    • 제19권2호
    • /
    • pp.107-112
    • /
    • 2013
  • In this paper, we discuss a 3-dimensional localization sensor node using EM waves (Electromagnetic waves) with RSSI (Received Signal Strength Indicator). Generally EM waves cannot be used in underwater environment, because the signal is highly attenuated by the water medium according to the distance. Although the signal quickly reduces in underwater, the reducing tendency is very clear and uniform. Hence EM waves have possibility as underwater distance sensors. The authors have verified the possibility by theory and several experiments, and developed calibration methods in case of linear and planer environment. For 3-dimensional localization in underwater, it must be known antenna's radiation pattern property in electric plane(called E-plane). In this paper, we proceed experiments to verify attenuation tendency with z axis movement, PLF (Polarization Loss Factor) and ILF (Inclination Loss Factor) with its theoretical approach.

구조물에서 방사되는 소음을 저감하기 위한 능동구조음향제어 (Active Structural Acoustic Control for Reduction of Radiated Sound from Structure)

  • 오재응;홍진석
    • 대한기계학회논문집A
    • /
    • 제25권9호
    • /
    • pp.1410-1415
    • /
    • 2001
  • Active control of sound radiation from a vibrating rectangular plate by a steady-state harmonic point force disturbance is experimentally studied. Structural excitation is achieved by two piezoceramic actuators mounted on the panel. Two accelerometers are implemented as error sensors. Estimated radiated sound signals using vibro-acoustic path transfer function are used as error signals. The vibro-acoustic path transfer function represents system between accelerometers and microphones. The approach is based on a multi-channel filtered-x LMS algorithm. The results shows that attenuation of sound levels of 11dB, 10dB is achieved.

항암치료 후 발생하는 구강 점막염의 병태생리 (Pathophysiology of Oral Mucositis induced by Anticancer Therapy)

  • 윤정훈;최종훈
    • Journal of Oral Medicine and Pain
    • /
    • 제25권4호
    • /
    • pp.365-369
    • /
    • 2000
  • Oral mucositis or stomatitis produced by stomatotoxic chemotherapy and/or radiation therapy are painful, restrict oral intake and, importantly, act as sites of secondary infection and potals of entry for the endogenous oral microflora often leading to bacteremias or sepsis. A number of clinical observations and studies of animal model suggests a pathophysiological complexity in the development of mucositis. The condition appears to represent a sequential interaction of the oral mucosal cells and tissues, pro-inflammatory cytokines, and local environmental factors in the mouth. This article discussed and reviewed biological process of the mucositis and, the role of cytokines as initiators and amplifiers of the process. The recognition that the pathophysiology of mucositis is a multifactorial process has presented opportunities for intervention based upon biological attenuation.

  • PDF

평판에서의 방사소음 저감을 위한 능동구조음향제어 (Active Structural Acoustic Control for Radiated Sound Reduction in Plate)

  • 홍진석;오재응;이유엽;신준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.608-612
    • /
    • 2000
  • Active control of sound radiation(using active structural acoustic control) from a vibrating rectangular plate by a steady-state harmonic point force disturbance is experimentally studied. Control structural input are achieved by two piezoceramic actuators bonded to the surface of the panel. Two accelerometers are implemented as error sensors. Estimated radiated sound signals using vibro-acoustic path transfer function are used as error signals. The vibro-acoustic path transfer function represents system between accelerometers and microphones. The control approach are based on a multi-channel filtered-x LMS algorithm. The results demonstrate that attenuation of sound levels of 3dB, 13dB are achieved.

  • PDF

적외선영상의 파장대역변환을 위한 추정온도 오차 보정 (Estimated Temperature Error Compensation for Wavelength-Band Conversion of Infrared Image)

  • 김영춘;안상호
    • 한국멀티미디어학회논문지
    • /
    • 제17권11호
    • /
    • pp.1270-1278
    • /
    • 2014
  • The modern infrared (IR) imaging systems use mainly one or more wavelength bands among short wavelength IR (SWIR), middle wavelength IR (MWIR), and long wavelength IR (LWIR) bands. In the process of IR image synthesis and modeling, IR image wavelength-band conversion which transforms arbitrary band image to other band one is required. The wavelength-band conversion procedure includes a temperature estimation process of an object surface. However, in this procedure, an approximated Planck's radiation equation causes errors in estimated temperature. In this paper, we propose an estimation temperature error attenuation method in IR image band conversion procedure. The estimated temperature is corrected with a slope information of radiance according to it. The corrected temperature is used for generation of the other band IR image. The verification of proposed method is demonstrated through the simulation.

회전기 권선의 펄스 전송특성 연구 (A Study on the Partial Discharge Wave Propagation along Stator Winding)

  • 강동식;심우용;황돈하;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.738-740
    • /
    • 2003
  • A lot of R&D on the diagnosis of stator winding insulation for large rotating machines has been carried out since the 1970s. The on-line partial discharge measurement has proved to be an effective technique in the evaluation of the state of stator insulation in high voltage rotating machines. It is well known that if the discharge pulses propagate through the winding conductor, they are attenuated and delayed. In the present study, to investigate the attenuation and the time delay of discharge pulses through the winding conductor, a series of tests were conducted using a model coils and slot. Thus it could be concluded that while the high frequency pulse propagates in radiation or end-winding coupling modes, the low frequency one does in a series mode through the coil conductor.

  • PDF

Ozone Measurments in the Stratosphere from KSR420S-1 and -2 : the Preliminary Results

  • Lee, Ki-Yiung-;Lee, Dong-Hun-;Kim, Jhoon-;Park, Chang-joon-
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.11-11
    • /
    • 1993
  • The Korean sounding rockets(KSR) 1, 2 equigped with the UV optical detectors have been launched at An-heung, Chungchongnam-do, of June 4 and September 1, 1993,respectively. The UV detector is used to measure the attenuation of solar UV radiation for various frequency bards in the stratospgere. We obtained the profile of the ozone number density within the altitulde of 15 - 30 km by applying the Beer-Lambert law. It is found that the maHimum of the ozone distribution occurs near 2sht which is quite consistent with the mean value in the mid-latituderegions. We will also compare our results froiu KSR 1,2 with the other observational data from the Dobson speceo meter at Yonsei Univ. and the LIDAa which were performed simultaneously with the sounding rocket experiments.

  • PDF

X-선 스펙트럼 변조 기술 연구 (X-Ray Spectrum Modulation for Mammography)

  • 김광현;김경락;오창현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.600-603
    • /
    • 2003
  • Energy spectrum modulation of X-ray source in digital mammography has been studied. In this study, we calculated various filtered spectra using the scattering data. Primary spectra were generated by Molybdenum (Mo) and Tungsten (W) targets. The materials of added filters are Molybdenum and Rhodium (Rh) for 40 kVp Mo. primary spectrum, the amounts of photons over whole energy ranges are attenuated to 0.43 with 0.03 mm Mo filter and 0.38 with 0.06 mm Mo filter while the photons of energy ranged from 17 keV to 20 keV. The photons of low energy ranged below 17 keV are considerably attenuated. This effect brings out reducing the scattered radiation and dose to the patient, and enhancing subject contrast in the image. The results show that filtered spectra are not seriously affected by X-ray tube loadability. Because the energy range from 17 keV to 20 keV is directly transmitted although low and high energies are mainly filtered.

  • PDF