• Title/Summary/Keyword: radial pulses

Search Result 32, Processing Time 0.018 seconds

Underwater object radial velocity estimation method using two different band hyperbolic frequency modulation pulses with opposite sweep directions and its performance analysis (두 대역 상반된 스윕방향 hyperbolic frequency modulation 펄스로 수중물체 시선속도추정 기법 및 성능분석)

  • Chomgun Cho;Euicheol Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.25-31
    • /
    • 2023
  • In order to estimate the radial speed of an underwater object so-called target with active sonar, Continuous Wave (CW) pulse is generally used, but if a target is slow and at near distance, it is not easy to estimate the radial velocity of the target due to acoustic reverberation in the ocean. In 2017, Wang et al. utilized broadband signal of two Hyperbolic Frequency Modulation (HFM) pulses, which is known as a doppler-invariant pulse, with equal frequency band and in opposite sweep directions to overcome this problem and successfully estimate the radial speed of slow-moving nearby target. They demonstrated the estimation of the radial velocity with computer simulation using the parameters of two HFM starting time differences and receiving times. However, for it uses two HFM pulses with equal frequency, cross-correlation between the two pulses negatively affect the detection performance. To mitigate this cross-correlation effect, we suggest using two different band HFM with the opposite sweep directions. In this paper, a method of radial velocity estimation is derived and simulated using two HFM pulses with the pulse length of 1 second and bandwidth of 400 Hz. Applying the suggested method, the radial velocity was estimated with approximately 6 % of relative error in the simulation.

8체질 맥법 검증을 위한 요골동맥 파형 측정 센서 개발

  • 문성수;정용원;이중재;공준웅;이흥세;전국진
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.9-12
    • /
    • 2001
  • In oriental medicine, it is possible to classify each person into eight kinds of constitutions based on the eight constitutional medicine theory. We developed a piezoelectric 3-channel tactile sensor using PVDF (polyvinylidene fluoride) film for pulse detection of the radial artery. High frequency buffer (impulse buffer), amplifier, 60 Hz noise notch filter and low pass filter were integrated on three sheets of PCB board. The pulses of the radial artery at three points were checked using our system. Each constitution of the eight ones has different combinations of pulses.

  • PDF

Axillo-Axillar bypass with Gore-Tex graft for a pulseless disease. (액와동맥간 Bypass Graft 를 이용한 무맥증 수술치험 1례)

  • 이신영
    • Journal of Chest Surgery
    • /
    • v.18 no.3
    • /
    • pp.466-469
    • /
    • 1985
  • The patient was 17 years old female who complained of coldness of right arm and occasional dizziness, since 4 months prior to admission. On physical examination, the right radial, brachial and common carotid arterial pulses were not palpable. Aortography revealed narrowing of innominate and right common carotid arteries, and complete obstruction of right subclavian artery. The right axillary artery was faintly visualized on the delayed film. Axillo-axillar bypass was done using Gore-Tex graft of 8 mm I.D.. By bilateral subclavicular incision, both side axillary arteries was exposed. End to side anastomosis was made between graft and right axillary artery and the graft was brought out to the left side, subcutaneously, over the sternum, and the anastomosis was made between graft and left axillary artery. Postoperatively, both radial pulses were equally palpable. On follow-up visiting, there were no subjective symptoms and blood pressure in both arms was equal.

  • PDF

Double Extra-anatomic Bypasses in Upper and Lower Extremities - A Report of Case - (이중성 비해부학적 우회술 치험 1례)

  • 이신영
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.330-336
    • /
    • 1989
  • The patient was 47-year-old male who had suffered from aphasia and hemiplegia of the right side, but mental state was alert. On physical examination, BP was 130/80 mmHg in the right arm, but not checked in the left arm. The pulses of the left common carotid, brachial, and radial arteries were not palpable. The pulses of the right femoral, popliteal, and dorsalis pedis arteries were weakly palpable. Brain CT Scan revealed cerebral infarction of the left hemisphere. Aortogram showed occlusion of the left common carotid, and the right internal carotid and common iliac arteries. Subclavian steal phenomena were observed in the delayed aortogram. Double extra-anatomic bypasses; Axillo-Axillar bypass and Femora-Femoral bypass, were performed in the local anesthesia at two stages, because of risk of major operation under general anesthesia. Postoperatively, all pulses except for pulse of the left common carotid artery were equally palpable. On discharge, the hemiplegia of the right side was improved and able to walk with assistance.

  • PDF

Localized Electro-chemical Micro Drilling Using Ultra Short Pulses (초단펄스 전해 국부화를 이용한 미세구멍 가공)

  • 안세현;류시형;최덕기;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.213-220
    • /
    • 2003
  • By the localization of electro-chemical dissolution region, we succeeded in a few micrometer size hole drilling on stainless steel with the radial machining gap of about 1 ${\mu}{\textrm}{m}$. Tens of nanosecond duration voltage pulses were applied between WC micro-shaft and stainless steel in the 0.1 M $H_2SO_4$ solution. Pt balance electrode was used to drill the high aspect ratio micro-hole without generation of Cr oxide layer on the machined surface. The effects of applied voltage, pulse duration, and pulse period on localization distance were investigated according to machining time. We suggested the taper reduction technique especially brought up on blind-hole machining. High quality micro-holes with 8 ${\mu}m$ diameter with 20 ${\mu}m$ depth and 12 ${\mu}m$ diameter with 100 ${\mu}m$ depth were drilled on 304 stainless steel foil. The various hole shapes were also produced including stepped holes and taper free holes.

A Study on the Auto-diagnosis Plethysmograph by Novel Algorithm for Radial Pulse Detection (새로운 맥파 인식 알고리즘을 적용한 자동 맥파 시스템에 관한 연구)

  • 박승환;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.241-246
    • /
    • 1996
  • This paper describes a new system that detects radial pulse wave and allows the diagnosis of malfunctions of cardiovascular system by analyzing the waveforms with the newly proposed algorithm. The system consists of a sensor part and a data processing part within which a new detection algorithm is incorporated In acquiring radial pulse signal noninvasively, the sensor used in this system is a new combinational fiber-optic sensor which has a detecting Part and a transmitting Part. Also, In order to analyze the characteristics of pulsation quantitatively, the algorithm proposed in this paper is a method that runs in parallel with both the data of ECG and differential pulse simultaneously. these concepts are based upon the idea that thfee Q points of ECG give obious discrimination of one entire period of pulse in any abnormal cases, and newly defined feature lines at the differential counterpart can be used to recogrlize sDme significant points in one period of pulses.

  • PDF

Relations between 10 Primary Pulse Conditions Based on Doctors' Pulse Diagnoses (전문가 진단에 기반한 10대 맥상들 간의 연관성에 대한 연구)

  • Lee, Jae-Chul;Kang, Nam-Sik;Lee, Hae-Jung;Kim, Jong-Yeol;Kim, Jae-Uk
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.6
    • /
    • pp.1077-1081
    • /
    • 2010
  • In this work, we report the diagnostic relations among some primary pulse conditions such as the floating/sunken, deficient/forceful, large/fine, and the long/short pulses. For this purpose, we carried out a clinical test, in which 11 Oriental medical doctors had participated to diagnose the pulses for 1566 healthy subjects. The subjects were divided into 11 subgroups and each subgroup was allocated to an individual doctor. It resulted in that, for 847 subjects (54%), two or more than two pulse conditions were felt simultaneously, for which we counted the frequency of the pairs of the pulse conditions. For the statistical analysis, we used a Chi-square test. As a result, at high frequency, the forceful, large, and the long pulses were diagnosed in pairs or in their triplet, and a similar close relation was found between the deficient, fine, and the short pulses. The pairwise diagnoses of the pulse conditions between the forceful, large, and the long pulses, and between the deficient, fine, and the short pulses imply their close relatedness in clinics. This result is supported by the theory of deficiency/excess syndromes. Moreover, we show that the close relatedness among the pulse conditions can be understood in terms of the geometric features of the radial artery near the prominent bone. This is the first work which reports the relatedness between the primary pulses by an objective clinical test.

Counting Method and Application of Pulse-taking on both Carotid and Wrist Pulses in Suwen·LiuJieCangXiangLun (『소문(素問)·육절장상론(六節藏象論)』의 인영(人迎)·촌구(寸口) 맥진(脈診)의 셈법과 활용에 대한 연구)

  • Jo, Hak-jun
    • Journal of Korean Medical classics
    • /
    • v.30 no.3
    • /
    • pp.77-93
    • /
    • 2017
  • Objectives : Clear and detailed analysis on Pulse-taking on both Carotid and Wrist Pulses is an absolute prerequisite if it is to be applied in real practice or its practical value proven. Methods : The original notes found in Suwen and Lingshu, their translations, and conventional studies regarding Suwen LiuJieCangXiangLun's Pulse-taking are compared and analyzed to find cases within medical texts where this method was used and to get an idea of the direction taken by the conventional study. Results : The ilsung, esung, samsung, and sasung of Carotid (or wrist pulses) refers that the pulse is one-, two-, three-, four-fold in differences. Refrainment should be practiced while comparing carotid and wrist pulses. Rather, they need to be compared with their normal states. Used by Luo Tianyi in Ming Dunasty, this method of pulse-taking was used for (radial artery) when diagnosing and treating the degree of seriousness of food injury. The measurement of maximum blood flow velocity using TCD done recently proved the validity of this pulse-taking, and it's been used for alleviating hypertension or tinnitus through acupuncture, or abating intractable diseases (around carotid). Conclusions : The obscurity of the measuring method of this pulse-taking can be resolved, and the problem which occurs while comparing carotid and wrist pulses can be solved. Even though there are differences in opinion regarding the positions when comparing the two pulses, their practical values are acknowledged since their usages in diagnosis, treatments, experiments, and researches have yielded positive results to a degree. They may not be used that often, but they are nonetheless under utilization.

A Successful Prosthetic Correction of Long Narrow Segment Coarctation of the Aorta: Report of A Case (대동맥축착에 대한 Teflon 인조혈관 이식술 치험예)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.10 no.1
    • /
    • pp.90-97
    • /
    • 1977
  • This is a report of a. case in which a long narrow segment coarctation of the aorta was successfully corrected with Teflon graft. The patient was 30 year old man with hypertensive symptoms that occurred 7 years prior to operation. Blood pressure measured 230/110 mmHg in the arms and 110/80 mmHg in the legs. Pulses were strongly tensive in radial artery, but very weak in femoral artery and even absent in dorsal pedis artery. Final preoperative diagnosis was made by aortography which showed a long narrow segment between aortic arch and descending thoracic aorta and highly developed collateral circulations. A long hypoplastic narrow segment was located proximal to the ligament arteriosus, and diaphragmatic stenosis of the aorta was located just distal to the ligamentum arteriosus. After prosthetic correction of the coarctation of the aorta, blood pressure were measured 130/ 80 mmHg in the arms and 150/100 mmHg in the legs. Peripheral pulses were palpated normally, and the postoperative course was uneventful.

  • PDF

Noninvasive Detection of Radial Pulse Wave by Fiber-Optic Transducer (광파이버 트랜스듀서에 의한 맥파의 무침습적 검출)

  • 박승환;정동명
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.229-236
    • /
    • 1989
  • This paper describes an idea of design and construction for a radial pulse wave detector, In acquiring arterial pulse signal noninvasively, a new combinational fiber-optic transducer was used which has a detecting part and a sensing part. The mechanism of detecting part is composed of special form of structure that can detect changing pulses in contact with skin, and transmits arterial wall movements to the sensing part. It consists of elastic reflector and optical fibers, which are arranged in a fiber pair. Then, the intensity of the reflected light will be proportional to the displacement changed by inclined reflector. Using this transducer, it expected to make a clinically useful tool for arterial pulse wave diagnosis, especially on the application of "MACK- CHIN" in the field of Korean traditional medicine, since : his transducer has a simple structure and has an easy and clear signal acquisition method.on method.

  • PDF