Axillo-Axillar bypass with Gore-Tex graft for a pulseless disease.

액와동맥간 Bypass Graft 를 이용한 무맥증 수술치험 1례

  • Published : 1985.09.01

Abstract

The patient was 17 years old female who complained of coldness of right arm and occasional dizziness, since 4 months prior to admission. On physical examination, the right radial, brachial and common carotid arterial pulses were not palpable. Aortography revealed narrowing of innominate and right common carotid arteries, and complete obstruction of right subclavian artery. The right axillary artery was faintly visualized on the delayed film. Axillo-axillar bypass was done using Gore-Tex graft of 8 mm I.D.. By bilateral subclavicular incision, both side axillary arteries was exposed. End to side anastomosis was made between graft and right axillary artery and the graft was brought out to the left side, subcutaneously, over the sternum, and the anastomosis was made between graft and left axillary artery. Postoperatively, both radial pulses were equally palpable. On follow-up visiting, there were no subjective symptoms and blood pressure in both arms was equal.

Keywords