• 제목/요약/키워드: radial pulse wave

검색결과 81건 처리시간 0.035초

500명 여성을 대상으로 한 팔강변증에 따른 맥파 특성 연구 (A Study on the Characteristics of Pulse Waves according to Eight Principle Pattern Identification in 500 Women)

  • 이인선;전수형;강창완;김종원
    • 동의생리병리학회지
    • /
    • 제35권6호
    • /
    • pp.274-279
    • /
    • 2021
  • This study was conducted to find objective diagnostic indicators for the Eight Principle Pattern Identification using a pulse wave analyzer. Typology Complexion Pulse and Symptom data from 500 women over the age of 18 were used. Five experts made a diagnosis of Eight Principle Pattern Identification and divided the subjects into 'Yin-Yang', 'Exterior-Interior', 'Cold-Heat', 'Deficiency-Excess' groups. Their pulse waves were measured in the left and right radial arteries, and it was investigated whether there was a significant difference between groups in the pulse wave parameter values. 'Yin' group showed a significantly lower value in the left radial artery for Ener, Emin, EIX, T4T, T4TT parameters and in the Right for T2, T2T, T5. The Vmag, As and Ad parameters were significantly different between the 'Exterior' and 'Interior' groups. 'Heat' group showed a significantly higher value in the right radial artery for RAI/t parameter. 'Deficiency' group showed a significantly higher value in the right radial artery for W, Angl parameters. Through this study, significant pulse wave parameters were found, and they can be used as objective diagnostic indicators for Eight Principle Pattern Identification.

위정격(胃正格) 자침이 정상 성인의 맥파(脈波)에 미치는 영향 (The Effect of Sa-Am Stomach Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects)

  • 최주영;강재희;임윤경;이현
    • Journal of Acupuncture Research
    • /
    • 제29권6호
    • /
    • pp.57-71
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am stomach tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Radial pulse were measured using 3 dimensional pulse imaging system(DMP-3000). 19 parameters that significantly changed were selected after comparing between acupuncture group and control group. Then, 19 parameters were analyzed before, immediately after, 30 minutes after and 60 minutes after acupuncture in acupucture group. Results : 1. Heart rate, pulse period, T/T1, T2/T, T4/T, T5/T, T-T4, (T-T4)/T and T4/(T-T4) significantly changed after acupuncture. 2. H1 Amplitude, H2 Amplitude, H4 Amplitude and H5 Amplitude significantly changed after acupuncture. 3. Area of Pulse Wave, Systolic Pulse Area, Diastolic Pulse Area and Area of W significantly changed after acupuncture. 4. AIx/HR significantly changed after acupuncture. Conclusion : Stomach Tonifying Acupuncture exerts an influence on radial pulse parameters. Further radial pulse change study on various acupuncture treatment is required.

USB Driver 전송시스템 기반의 맥파 측정 시스템에 관한 연구 (A Study on Pulse Wave Measurement System Based on USB Driver Transmission System)

  • 김은근;박미경;한승신;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1914-1915
    • /
    • 2007
  • The period and strength of the pulse on the radial artery are important physiological factors, and they have been used to diagnosis in both Western and Eastern countries for a long time and has been developed as a unique method of diagnosis at each countries. Recently, there are a lot of systems which can give diagnosis information by recording the pulse wave and analyzing the characteristics of the pulse shape. This study describes the Pulse-Wave Measurement System which is able to measure the pulse wave signal using piezoresistive sensor and the pulse wave signal measured by the developed system is transmitted to a computer on the basis of the USB Driver. It has finally shown the the pulse wave signal measured by the sender is appeared to the host PC in real time. The Pulse-Wave Measurement System used the piezoresistive sensor to measure the pulse wave signal and the differential amplifier(AD620) to amplify the pulse wave signal which is small signal. And it used the ADC to convert analog to digital for the measured analog signal and the interface with a computer. It transmitted the measured pulse signal through USB transmission module to the host computer and Labview tool shows it. This Pulse-Wave measurement system will afford comvenience of detecting pulse wave to user related to oriental medicine.

  • PDF

식사에 따른 맥상파 변화 연구 -h1, t, 맥(脈)에너지, RAI를 중심으로- (Waveform Changes of the Radial Pulsation Followed by the Food Intakes in Healthy Subjects)

  • 김경철;이정원;류경호;김이순
    • 한국한의학연구원논문집
    • /
    • 제17권3호
    • /
    • pp.87-96
    • /
    • 2011
  • Objectives : The study on the affected factor of the pulse wave is important in the pulse wave part. The purpose of this study is to secure the objective data of pulse-wave parameter on the food intakes affected the radial pulse-wave. Methods : The study was carried out healthy adult men. We researched the blood circulation index and the changes of the pulse factor according to 'before meal', 'right after meal', '30 minute after meal', '1 hour after meal' and '2 hours after meal'. We analyzed the changes according the time schedule. And analyzed the difference between 'before meal' and 'after meal'on the pulse-wave parameter. Results : The results were as follows. 1. HR, ECO and ECI were showed the highest increase 'after meal' and the significant decrease in '2 hours after meal' with 'before meal' degree. 2. In the pulse energy, 'left hand average pulse energy' was showed the highest increase 'after meal', and 'right hand average pulse energy' and 'right Quan(關)' were showed the highest increase in '30 minute after meal'. 3. h1 of '6 part of left and right hand'(Chon-Quan-Chuk, 寸關尺) was showed the significant difference statistically in 'left Chuk' and 'right Quan'. 4. T was showed the highest 'before meal' and the lowest after meal in '6 part of left and right' (Chon-Quan-Chuk, 寸關尺). 5. RAI was showed the highest 'before meal' in '6 part of left and right'(Chon-Quan-Chuk 寸關尺). Conclusions : From the about results, the food intakes was considered important factor of pulse formation. On the factor affected the pulse, we considered that continuous study needs for the future.

디지털 가변저항과 지수가중 이동평균필터를 통한 요골동맥에서의 PPG 파형과 맥박 측정에 관한 연구 (A Study of PPG Wave and Pulse Measurement on Radial Artery Using Digital Potentiometer and Exponentially Weighted Moving Average Filter)

  • 정인복;김경호
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.962-967
    • /
    • 2014
  • In this paper, through a digital potentiometer and exponentially weighted moving average filter, pulse and PPG waveform measurable device was fabricated in radial artery. If this device is not proper about signal size in analog part, MCU can judge easily by adjusted amplification through digital potentiometer, using exponentially weighted moving average filter is able to filter out more clear value of ADC. I presumed pulse rate as value of measuring time between point of maximum contraction from sensing signal in radial artery of wrist. Therefore, this means can measure stable pulse rate and PPG waveform, finger as well as radial artery, whether signal size of each person is different finger as well as radial artery.

광파이버 트랜스듀서에 의한 맥파의 무침습적 검출 (Noninvasive Detection of Radial Pulse Wave by Fiber-Optic Transducer)

  • 박승환;정동명
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.229-236
    • /
    • 1989
  • This paper describes an idea of design and construction for a radial pulse wave detector, In acquiring arterial pulse signal noninvasively, a new combinational fiber-optic transducer was used which has a detecting part and a sensing part. The mechanism of detecting part is composed of special form of structure that can detect changing pulses in contact with skin, and transmits arterial wall movements to the sensing part. It consists of elastic reflector and optical fibers, which are arranged in a fiber pair. Then, the intensity of the reflected light will be proportional to the displacement changed by inclined reflector. Using this transducer, it expected to make a clinically useful tool for arterial pulse wave diagnosis, especially on the application of "MACK- CHIN" in the field of Korean traditional medicine, since : his transducer has a simple structure and has an easy and clear signal acquisition method.on method.

  • PDF

새로운 맥파 인식 알고리즘을 적용한 자동 맥파 시스템에 관한 연구 (A Study on the Auto-diagnosis Plethysmograph by Novel Algorithm for Radial Pulse Detection)

  • 박승환;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.241-246
    • /
    • 1996
  • This paper describes a new system that detects radial pulse wave and allows the diagnosis of malfunctions of cardiovascular system by analyzing the waveforms with the newly proposed algorithm. The system consists of a sensor part and a data processing part within which a new detection algorithm is incorporated In acquiring radial pulse signal noninvasively, the sensor used in this system is a new combinational fiber-optic sensor which has a detecting Part and a transmitting Part. Also, In order to analyze the characteristics of pulsation quantitatively, the algorithm proposed in this paper is a method that runs in parallel with both the data of ECG and differential pulse simultaneously. these concepts are based upon the idea that thfee Q points of ECG give obious discrimination of one entire period of pulse in any abnormal cases, and newly defined feature lines at the differential counterpart can be used to recogrlize sDme significant points in one period of pulses.

  • PDF

촌관척(寸關尺)부의 검측한 부정맥과 Electrocardiographic 결과의 한의학적 검토 (The Oriental Medical Study about the Arrythmia Detected on the Radial Pulses and the Result of ECG.)

  • 류희영;허은정;김지현;윤정미;전성하
    • 동의신경정신과학회지
    • /
    • 제19권2호
    • /
    • pp.165-193
    • /
    • 2008
  • Objective: The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒)type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. Method & Conclusion: 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using ECG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the ECG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血) had downward aptitude of QRS wave, the wave which had both Cold(寒)) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈)is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). Result : From these results, we will have to study about ECG which using in tests of change of Parkinsons disease.

  • PDF

정상 혈압군과 고혈압군에서의 맥파 파라미터 분석에 관한 연구 (Pulse Wave Parameters Changes between Normotensive and Hypertensive Group)

  • 김은근;허현;남기창;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1999-2000
    • /
    • 2008
  • In this study, pulse wave parameters changes were verified between normotensive and hypertensive group. To measure pulse wave in radial artery, non-invasive tonometric pulse wave measurement device (SphygmoCor PX, AtCor, Austrailia) was used. 136 subjects participated in this study. Among 20 parameters, 16 parameters changes were analysed(p < 0.05) between normotensive(n=104) and hypertensive group(n=32). As a results, several parameters related with pulse pressure, reflective pulse wave, systolic and diastolic function of heart showed significant difference between normotensive and hypertensive group.

  • PDF

측정 자세 및 상완 혈압에 의한 맥파 특성 변화 (Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure)

  • 남기창;김은근;허현;허영
    • 감성과학
    • /
    • 제12권3호
    • /
    • pp.299-306
    • /
    • 2009
  • 본 연구에서는 비침습적으로 압력 맥파를 검출하는 토노메트리 방식의 맥파 측정 장비인 SphygmoCor(AtCor, Australia)를 사용하여 측정자세에 따라 맥파를 측정하였다. 측정 결과를 통해 선 자세, 앉은 자세, 누운 자세에 따른 맥파의 분석 지표들의 변화를 분석하였다. 또한 측정된 데이터를 저혈압군, 정상혈압군, 고혈압군으로 구분하여 혈압군에 따른 맥파의 비교를 수행하였다. 그 결과 자세에 따른 요골동맥의 파형에서 유의차를 보인 분석지표는 맥파의 진폭에 해당되는 압력 보다 주요 피크가 발생되는 시간에서 나타났다. 맥압의 경우 맥파증대계수(AI)나 중심동맥압과 요골동맥압의 비율과 같이 맥압 간의 비율이 자세에 따른 변별력이 있었다. 사후검정에 따라 각 자세별로 상호 간에 모두 유의한 차이를 보인 분석지표는 주파(P_$T_1$)와 반사파(P_$T_2$)의 시간, 심박출지속시간(ED), 심박수(HR)로 나타났다. 혈압군에 대한 비교에서 대부분 맥파의 시간에 해당되는 지표보다 주요 피크의 진폭에 해당되는 맥파의 압력을 나타내는 지표가 혈압군에 따른 유의차를 보였다.

  • PDF