Pulse Wave Parameters Changes between Normotensive and Hypertensive Group

정상 혈압군과 고혈압군에서의 맥파 파라미터 분석에 관한 연구

  • Kim, Eun-Geun (Korea Electrotechnology Research Institute) ;
  • Heo, Hyun (Korea Electrotechnology Research Institute) ;
  • Nam, Ki-Chang (Korea Electrotechnology Research Institute) ;
  • Huh, Young (Korea Electrotechnology Research Institute)
  • Published : 2008.07.16

Abstract

In this study, pulse wave parameters changes were verified between normotensive and hypertensive group. To measure pulse wave in radial artery, non-invasive tonometric pulse wave measurement device (SphygmoCor PX, AtCor, Austrailia) was used. 136 subjects participated in this study. Among 20 parameters, 16 parameters changes were analysed(p < 0.05) between normotensive(n=104) and hypertensive group(n=32). As a results, several parameters related with pulse pressure, reflective pulse wave, systolic and diastolic function of heart showed significant difference between normotensive and hypertensive group.