• 제목/요약/키워드: radial motion

검색결과 303건 처리시간 0.026초

적외선카메라를 이용한 다트던지기 운동에서의 제한된 손목관절 움직임 분석 (The Motion Analysis of the limited Wrist Joint During Dart-Throwing Motion by Using Infrared Camera)

  • 박찬수;박종일;김광기;장익규;김태윤;이상림;백구현
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.55-62
    • /
    • 2013
  • Wrist joints consist of irregularly shaped carpal bones and other complicated structures. Thus, evaluating the motion of a wrist joint is a challenging task. In this study, we used an infrared camera to perform a kinematic analysis of a dart-throwing motion. We measured the difference between the movement of a normal wrist and constrained wrist (wrist with a wrist glove) in the dart-throwing motion with thirty six healthy participants. We measured the ulna flexion - radial extension motion using the attached passive marker and analyzed it using Polygon software and SPSS. The pitch and yaw motions with a glove was bigger than the ones without a glove by 20 and 15 degrees, respectively. On the other hand, the roll motion without a glove was bigger than the one with a glove by 7 degree. Wilcoxon signed rank test (p<0.05) confirmed that there are significant differences between the motion with and without a glove. It was found that the magnitude of the pitch and yaw motion with a constrained wrist joint toward radial extension in dart-throwing motion is smaller than the one with a normal wrist joint. However, a normal wrist joint showed a bigger movement in the roll direction.

3차원 영상을 이용한 다트 던지기 운동에서의 주상골, 유두골, 월상골의 움직임 분석 (The Motion Analysis of the Scaphoid, Capitate and Lunate During Dart-Throwing Motion Using 3D Images)

  • 박찬수;김광기;김유신;정창부;장익규;이상림;오수찬;유도현;백구현
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권2호
    • /
    • pp.144-150
    • /
    • 2011
  • The primary purpose of this study was to analyze the motion of the scaphoid, capitate, and lunate during dart-throwing motion by three-dimensional modeling. Five series of CT images of five normal right wrists were acquired from five motion steps from radial extension to ulnar flexion in the dart-throwing motion plane. Segmentation and three-dimensional modeling of bones from CT images was performed using Analyze. Distances among centroids of the scaphoid, capitate and lunate and angles between principal axes of three carpal bones were calculated to analyze the motion by using MATLAB. As the wrist motion changed from radial extension to ulnar flexion, the distance between two adjacent bones decreased. The scaphoid and lunate rotated less than the capitates during dart-throwing motion. This study reports the Three-dimensional in vivo measurement of carpal motion using CT images.

스핀들회전오차 종합적성능평가 기술에 관한 연구 (Combined Error Performance of Machine Tool spindle)

  • 신현장;이석원;박희재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.333-337
    • /
    • 1996
  • The spindle directly affects parts accuracy during machining, or work piece in machine tools. In this paper a comprehensive study is performed combined mr performance of machine tool spindle. The developed methology has been practically applied to a spindle of machine tools.

  • PDF

구형 압전 변환기의 점대칭 방사모드 진동 특성 (Vibration Characteristics of the Point-symmetric Mode in a Spherical Piezoelectric Transducer)

  • 전한용;김진오
    • 한국음향학회지
    • /
    • 제21권8호
    • /
    • pp.757-765
    • /
    • 2002
  • 본 논문은 해석과 실험을 통하여 구형 압전 변환기의 점대칭 방사모드 진동 특성을 규명하는 것을 목적으로 한다. 반경 방향 좌표와 시간의 함수인 반경 방향 변위와 전기 퍼텐셜로 표현되는 지배방정식을 구성한다. 역학적 경계조건과 전기적 경계조건을 적용하여 방사 진동의 특성방정식을 유도한다. 이 식을 이용하여 압전 고유진동수를 계산하고, 그 결과를 측정 결과와 비교한다. 수치계산을 통하여 압전 공진과 탄성 공진의 차이, 구형 압전체의 반경 및 두께에 따른 고유진동수 등을 고찰한다. 그 결과 1차 방사모드의 고유진동수 크기는 압전현상으로 인해 작아지며 구형의 곡률 반지름이 커짐에 따라 지수함수적으로 작아지는 것을 알게 되었다.

Comparison of Three, Motion-Resistant MR Sequences on Hepatobiliary Phase for Gadoxetic Acid (Gd-EOB-DTPA)-Enhanced MR Imaging of the Liver

  • Kim, Doo Ri;Kim, Bong Soo;Lee, Jeong Sub;Choi, Guk Myung;Kim, Seung Hyoung;Goh, Myeng Ju;Song, Byung-Cheol;Lee, Mu Sook;Lee, Kyung Ryeol;Ko, Su Yeon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권2호
    • /
    • pp.71-81
    • /
    • 2017
  • Purpose: To compare three, motion-resistant, T1-weighted MR sequences on the hepatobiliary phase for gadoxetic acid-enhanced MR imaging of the liver. Materials and Methods: In this retrospective study, 79 patients underwent gadoxetic acid-enhanced, 3T liver MR imaging. Fifty-nine were examined using a standard protocol, and 20 were examined using a motion-resistant protocol. During the hepatocyte-specific phase, three MR sequences were acquired: 1) gradient recalled echo (GRE) with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA); 2) radial GRE with the interleaved angle-bisection scheme (ILAB); and 3) radial GRE with golden-angle scheme (GA). Two readers independently assessed images with motion artifacts, streaking artifacts, liver-edge sharpness, hepatic vessel clarity, lesion conspicuity, and overall image quality, using a 5-point scale. The images were assessed by measurement of liver signal-to-noise ratio (SNR), and tumor-to-liver contrast-to-noise ratio (CNR). The results were compared, using repeated post-hoc, paired t-tests with Bonferroni correction and the Wilcoxon signed rank test with Bonferroni correction. Results: In the qualitative analysis of cooperative patients, the results for CAIPIRINHA had significantly higher ratings for streak artifacts, liver-edge sharpness, hepatic vessel clarity, and overall image quality as compared to, radial GRE, (P < 0.016). In the imaging of uncooperative patients, higher scores were recorded for ILAB and GA with respect to all of the qualitative assessments, except for streak artifact, compared with CAIPIRINHA (P < 0.016). However, no significant differences were found between ILAB and GA. For quantitative analysis in uncooperative patients, the mean liver SNR and lesion-to-liver CNR with radial GRE were significantly higher than those of CAIPIRINHA (P < 0.016). Conclusion: In uncooperative patients, the use of the radial GRE sequence can improve the image quality compared to GRE imaging with CAIPIRINHA, despite the data acquisition methods used. The GRE imaging with CAIPIRINHA is applicable for patients without breath-holding difficulties.

머시닝 센터에서 원운동정도 측정시스템의 개발 (Developement of Measuring System of Circular Motion Accuracy in Machining Center)

  • 김영석
    • 한국생산제조학회지
    • /
    • 제4권3호
    • /
    • pp.58-66
    • /
    • 1995
  • It is very important to test motion accuracy and performance of NC machine tools as they affect that of all other machines machined by them in industry. In this paper, in has become possible to detect errors of linear displacement of radial direction for circular motion test using newly assembled magnetic type of linear scales so called Magnescale ball bar system, and to calculate time interval getting error motion data and revolution angle of circular motion in machining center using tick pulses come out from computer. And a set of error data gotten from test is expressed to a plot by computer treatment and to numerics of error motion by statistical treatment and results of test are compared with those of Renishaw ball bar system.

  • PDF

진행된 키엔벡 병에서의 방형회내근 유경 요골 피판을 이용한 관절성형술의 중장기 결과 (Mid to Long-term Outcome of Vascularized Pronator Quadratus-wrapped Radial Bone Flap Arthroplasty for Advanced $Kienb{\ddot{o}}ck's$ Disease)

  • 공현식;백구현;이영호;김세훈;조영재;정문상
    • Archives of Reconstructive Microsurgery
    • /
    • 제15권2호
    • /
    • pp.101-106
    • /
    • 2006
  • The purpose of this study was to analyze the mid to long-term clinical and radiological outcome of vascularized pronator quadratus-wrapped radial bone flap arthroplasty for symptomatic advanced $Kienb{\ddot{o}}ck's$ disease. Between 1982 and 2000, 41 cases of advanced $Kienb{\ddot{o}}ck's$ disease were treated with vascularized pronator quadratus wrapped radial bone flap arthroplasty. There were 17 men and 24 women, with a mean age of 39 years at the time of operation. According to Lichtman's classification, there were 13 stage IIIb and 28 stage IV patients. The duration of follow-up averaged 6.1 ($3{\sim}22$) years. We assessed the clinical outcome by subjective pain and active range of motion of the wrist, and evaluated the radiologic outcome by using carpal height ratio and radioscaphoid angle. Postoperatively, all patient reported an improvement in their symptoms. The mean active extension and flexion were improved by $9^{\circ}$ and $6^{\circ}$, respectively (p<0.05). The carpal height ratio was decreased from a mean of 0.52 to 0.48, and the radioscahpoid angle was increased from a mean of $61^{\circ}$ to $66^{\circ}$, but the differences were not significant statistically. Vascularized pronator quadratus-wrapped radial bone flap arthroplasty improves the wrist motion and may prevent serious carpal collapse in advanced $Kienb{\ddot{o}}ck's$ Disease.

  • PDF

압력 평형형 소형 베인펌프에서의 베인 이간 현상 측정 (The Measurement of Detachment of Vane Tip in a Positive Displacement Small Vane Pump)

  • 안형준;양광식;한동철;박민호
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.365-370
    • /
    • 1998
  • This paper reports on the measurement of the vane motion in a positive displacement small vane pump. The capacitive method using ceramic vane is proposed to measure the vane motion. This method enables us to measure only radial motion of the vane regardless of the motions of other directions. With simple experiments and solutions of simultaneous equations, the indirect compensation of measured signal was performed.

  • PDF

원추형 능동 자기베어링계의 모형화 및 제어 (Modeling and Control of Cone-Shaped Active Magnetic Bearing System)

  • 정호섭;김철순;이종원
    • 대한기계학회논문집
    • /
    • 제17권12호
    • /
    • pp.3073-3082
    • /
    • 1993
  • A magnetically suspended robot joint is developed, which is free of dust and oil generation. Two radial bearings consisting of cone-shaped magnet cores control the rotor motion in the axial and radial directions. A linearized dynamic model is developed for active control of the magnetic bearing system. The control algorithm is constructed such that the axial displacement of the joint is controlled by radial control current to the pairs of facing radial bearings. The stability and control performance is tested through numerical simulation based on the nonlinear model. Experiments are also performed to verify the theoretical development.