• 제목/요약/키워드: quasi-static tests

검색결과 192건 처리시간 0.021초

Quasi-static cyclic displacement pattern for seismic evaluation of reinforced concrete columns

  • Yuksel, E.;Surmeli, M.
    • Structural Engineering and Mechanics
    • /
    • 제37권3호
    • /
    • pp.267-283
    • /
    • 2011
  • Although earthquakes generate random cyclic lateral loading on structures, a quasi-static cyclic loading pattern with gradually increasing amplitude has been commonly used in the laboratory tests because of its relatively low cost and simplicity compared with pseudo-dynamic and shake table tests. The number, amplitudes and sequence of cycles must be chosen appropriately as important parameters of a quasi-static cyclic loading pattern in order to account for cumulative damage matter. This paper aims to reach a new cyclic displacement pattern to be used in quasi-static tests of well-confined, flexure-dominated reinforced concrete (RC) columns. The main parameters of the study are sectional dimensions, percentage of longitudinal reinforcement, axial force intensity and earthquake types, namely, far-fault and near-fault.

An evaluation of iced bridge hanger vibrations through wind tunnel testing and quasi-steady theory

  • Gjelstrup, H.;Georgakis, C.T.;Larsen, A.
    • Wind and Structures
    • /
    • 제15권5호
    • /
    • pp.385-407
    • /
    • 2012
  • Bridge hanger vibrations have been reported under icy conditions. In this paper, the results from a series of static and dynamic wind tunnel tests on a circular cylinder representing a bridge hanger with simulated thin ice accretions are presented. The experiments focus on ice accretions produced for wind perpendicular to the cylinder at velocities below 30 m/s and for temperatures between $-5^{\circ}C$ and $-1^{\circ}C$. Aerodynamic drag, lift and moment coefficients are obtained from the static tests, whilst mean and fluctuating responses are obtained from the dynamic tests. The influence of varying surface roughness is also examined. The static force coefficients are used to predict parameter regions where aerodynamic instability of the iced bridge hanger might be expected to occur, through use of an adapted theoretical 3-DOF quasi-steady galloping instability model, which accounts for sectional axial rotation. A comparison between the 3-DOF model and the instabilities found through two degree-of-freedom (2-DOF) dynamic tests is presented. It is shown that, although there is good agreement between the instabilities found through use of the quasi-steady theory and the dynamic tests, discrepancies exist-indicating the possible inability of quasi-steady theory to fully predict these vibrational instabilities.

점용접된 차체구조용 모자형 단면부재의 축방향 압궤특성 (Collapse Characteristics of vehicle Members with Spot Welded Hat-Shaped Section under Axial Compression)

  • 차천석;양인영;전형주;김용우;김정호
    • 한국안전학회지
    • /
    • 제15권4호
    • /
    • pp.20-27
    • /
    • 2000
  • The hat shaped section members, spot welded strength resisting structures are the most energy absorbing ones of automobile components during the front-end collision. Under the static axial collapse load in velocity of 10mm/min and quasi-static collapse load in velocity of 1000mm/min, the collapse characteristics of the hat shaped section and double hat shaped section member have been analyzed by axial collapse tests with respect to the variations of spot weld pitches on the flanges. In addition, the quasi-static collapse simulations have been implemented in the same condition to the experiment's using FEM package, LS-DYNA3D. The simulated results have been verified in comparison with these from the quasi-static axial collapse tests. With the computational approaches the optimal energy absorbing structures can be suggested. Simulations are so helpful that the optimized data be supplied in designing vehicles in advance.

  • PDF

충격시 CFRP 복합재 판의 거동과 충격후 압축강도에 관한 실험적 연구 (Experimental Investigation on the Behaviour of CFRP Laminated Composites under Impact and Compression After Impact (CAI))

  • Lee, J.;Kong, C.;Soutis, C.
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.129-134
    • /
    • 2003
  • The importance of understanding the response of structural composites to impact and CAI cannot be overstated to develop analytical models for impact damage and CAI strength predictions. This paper presents experimental findings observed from quasi-static lateral load tests, low velocity impact tests, CAI strength and open hole compressive strength tests using 3mm thick composite plates ($[45/-45/0/90]_{3s}$ - IM7/8552). The conclusion is drawn that damage areas for both quasi-static lateral load and impact tests are similar and the curves of several drop weight impacts with varying energy levels (between 5.4 J and 18.7 J) fallow the static curve well. In addition, at a given energy the peak force is in good agreement between the static and impact cases. From the CAI strength and open hole compressive strength tests, it is identified that the failure behaviour of the specimens was very similar to that observed in laminated plates with open holes under compression loading. The residual strengths are in good agreement with the measured open hole compressive strengths, considering the impact damage site as an equivalent hole. The experimental findings suggest that simple analytical models for the prediction of impact damage area and CAI strength can be developed on the basis of the failure mechanism observed from the experimental tests.

  • PDF

발포 EPP/EPS의 충격특성에 관한 실험적 연구 (Experimental Study for the Impact Characteristics of Expanded EPP/EPS Foams)

  • 김한국;김병준;정광영;전성식
    • Composites Research
    • /
    • 제26권6호
    • /
    • pp.343-348
    • /
    • 2013
  • 본 연구에서는 발포 폴리프로필렌(Expanded polypropylene)과 발포 폴리스티렌(Expanded polystyrene)의 준정적 시험(Quasi-static test) 및 계장화 충격 시험(Instrumented impact test)을 수행하였다. EPP와 EPS는 4가지의 다른 밀도에 대해 원통형 시편이 준비되었다. 준정적 시험에는 MTS 858을 사용하여 0.001 $s^{-1}$과 0.1 $s^{-1}$ 두 가지 변형률속도 조건으로 진행되어 결과를 분석하였다. 계장화 충격 시험에서는 Instron dynatup 9250HV를 사용하여, 각각 100 J, 200 J, 300 J의 서로 다른 충격에너지를 가했을 때의 응력-변형률 선도 결과를 비교 분석하였다.

강합성교각의 내진성능평가 Part II: 유사동적실험 및 잔류내진성능 평가 (Seismic Performance of Concrete-Filled Steel Piers Part II: Pseudo-Dynamic Test and Residual Seismic Capacity)

  • 조창빈;서진환;장승필
    • 한국지진공학회논문집
    • /
    • 제6권2호
    • /
    • pp.21-28
    • /
    • 2002
  • Ductile behavior and strength of concrete-filled steel(CFS) piers was supported by many quasi-static cyclic loading tests. This test method, however, only estimates the member′s deformation capacity under escalating and repetitive displacement and ignores dynamic and random aspects of an earthquake load. Therefore, to understand complete seismic behavior of the structure against an earthquake, dynamic tests such as shaking table test and pseudo-dynamic tests are required as well as quasi-static tests. In this paper, following "Seismic Performance of Concrete-Filled Steel Piers Part I : Quasi-Static Cyclic Loadint Test", the seismic behavior of CFS and steel piers designed for I-Soo overpass in Seoul in investigated by the pseudo-dynamic test. In addition, the residual strength of both piers after an earthquake is estimated by the quasi-static test. The results show that both piers have satisfactory ductility and strength against well-known EI Centro earthquake although the CFS pier has better strength and energy dissipation than the steel pier.

An Experimental Study on the Axial Collapse Characteristics of Hat and Double Hat Shaped Section Members at Various Velocities

  • Cha, Cheon-Seok;Chung, Jin-Oh;Yang, In-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.924-932
    • /
    • 2004
  • In this study, the axial collapse tests were performed under either static (or quasi-static) or impact loads with several collapse velocities based on the expectation that para-closed sections of the front-end side members (spot welded hat and double hat shaped section members) would show quite different collapse characteristics from those for seamless section. The test results showed that both of the hat and double hat shaped section members failed in the stable sequential collapse mode in the static or quasi-static collapse tests, while the double hat shaped section members underwent the unstable collapse mode especially when the impact velocity is high. The mean collapse loads in the hat shaped section members increase with collapse velocity for all the cases of the static, quasi-static, and impact collapse tests. In the double hat shaped section members, however, the mean collapse loads decrease with increase in collapse velocity in the impact tests.

Laminate composites behavior under quasi-static and high velocity perforation

  • Yeganeh, E. Mehrabani;Liaghat, G.H.;Pol, M.H.
    • Steel and Composite Structures
    • /
    • 제22권4호
    • /
    • pp.777-796
    • /
    • 2016
  • In this paper, the behavior of woven E-glass fabric composite laminate was experimentally investigated under quasi-static indentation and high velocity impact by flat-ended, hemispherical, conical (cone angle of $37^{\circ}$ and $90^{\circ}$) and ogival (CRH of 1.5 and 2.5) cylindrical perforators. Moreover, the results are compared in order to explore the possibility of extending quasi-static indentation test results to high velocity impact test results in different characteristics such as perforation mechanisms, performance of perforators, energy absorption, friction force, etc. The effects of perforator nose shape, nose length and nose-shank connection shapes were investigated. The results showed that the quasi-static indentation test has a great ability to predict the high velocity impact behavior of the composite laminates especially in several characteristics such as perforation mechanisms, perforator performance. In both experiments, the highest performance occurs for 2.5 CRH projectile and the lowest is related to blunt projectiles. The results show that sharp perforators indicate lower values of dynamic enhancement factor and the flat-ended perforator represents the maximum dynamic enhancement factor among other perforators. Moreover, damage propagation far more occurred in high velocity impact tests then quasi-static tests. The highest damage area is mostly observed in ballistic limit of each projectile which projectile deviation strongly increases this area.

Extraction of quasi-static component from vehicle-induced dynamic response using improved variational mode decomposition

  • Zhiwei Chen;Long Zhao;Yigui Zhou;Wen-Yu He;Wei-Xin Ren
    • Smart Structures and Systems
    • /
    • 제31권2호
    • /
    • pp.155-169
    • /
    • 2023
  • The quasi-static component of the moving vehicle-induced dynamic response is promising in damage detection as it is sensitive to bridge damage but insensitive to environmental changes. However, accurate extraction of quasi-static component from the dynamic response is challenging especially when the vehicle velocity is high. This paper proposes an adaptive quasi-static component extraction method based on the modified variational mode decomposition (VMD) algorithm. Firstly the analytical solutions of the frequency components caused by road surface roughness, high-frequency dynamic components controlled by bridge natural frequency and quasi-static components in the vehicle-induced bridge response are derived. Then a modified VMD algorithm based on particle swarm algorithm (PSO) and mutual information entropy (MIE) criterion is proposed to adaptively extract the quasi-static components from the vehicle-induced bridge dynamic response. Numerical simulations and real bridge tests are conducted to demonstrate the feasibility of the proposed extraction method. The results indicate that the improved VMD algorithm could extract the quasi-static component of the vehicle-induced bridge dynamic response with high accuracy in the presence of the road surface roughness and measurement noise.

SRC 합성교각의 준정적 실험 (Quasi-Static Tests on SRC Composite Columns)

  • 심창수;정영수;정인근;민진;한정훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.299-302
    • /
    • 2005
  • This study deals with the quasi-static tests on steel reinforced concrete composite columns with single embedded steel or multiple members. For the design of bridge piers, the composite section needs to have low steel ratio for cost savings because the dimension of the pier section is usually large. There is lack of design guidelines for these composite columns with low steel ratio, but the design provisions for the normal reinforced concrete column can be used for the design because of the low steel ratio. It is necessary to provide the design provisions in terms of the strength limit state and seismic performance by the detail requirements on the longitudinal steel and the transverse steel. The test parameters in this study were determined considering the current design provisions on RC columns. Through the quasi-static tests, the seismic performance of the composite columns were discussed.

  • PDF