• Title/Summary/Keyword: quantitative test

Search Result 2,292, Processing Time 0.031 seconds

Study on the annoyance response of subway station noise using jury evaluation test (청감실험을 통한 도시철도 승강장 소음의 성가심 반응에 대한 연구)

  • Kim, Dong-Jun;Kim, Deuk-Sung;Son, Jin-Hee;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.670-677
    • /
    • 2009
  • The purpose of this study is to reveal the quantitative dose-response relationship between the noise emitted in the platform of subway station and the public response. The noise measured in the platform of subway station was used for a jury test. In order to find the factors which influence annoyance response due to the platform noise, jurors were examined for the difference of the annoying response, interrelation of sound quality parameter and annoyance response. The platform noise level was 77.2$\sim$83.9 dBA and the most of passengers at the platform were highly annoyed. And screen door contributes to annoyance reduction of platform noise. The results from analyzing sound quality parameters shows that loudness and annoyance response have a high correlation coefficient.

  • PDF

The evaluation of friction factor according to materials and lubricants (재료 및 윤활제에 따른 전단 마찰 상수값과 평가)

  • 김동진
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.119-124
    • /
    • 1999
  • Quantitative evaluation of the tribological conditions at the tool-workpiece interface in metal forming is usually accomplished by the ring-compressinon. test This paper describes an experimental investigation into shear friction factor under cold and hot forming conditions according to materials and lubricants using the ring compression test. Six different materials and five different lubricants were applied in the experiments. calibration curves with the friction coefficient were obtained using FEM analysis and verified by the verified by the experimental results. The influence of materials and lubricants level on friction are discussed. In the ring compression test the shear friction factor has a different from steels and aluminum water base graphite lubricants on cold working conditions and hot working conditions.

  • PDF

Effect of surface toughness on the interfacial adhesion energy between glass wafer and UV curable polymer for different surface roughness (표면거칠기에 따른 글래스 웨이퍼와 UV 경화 폴리머사이의 계면접착 에너지 평가)

  • Jang, Eun-Jung;Hyun, Seoung-Min;Choi, Dae-Geun;Lee, Hak-Joo;Park, Young-Bae
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.40-44
    • /
    • 2008
  • The interfacial adhesion energy between resist and a substrate is very important due to resist pull-off problems during separation of mold from a substrate in nanoimprint process. And effect of substrate surface roughness on interfacial adhesion energy is very important. In this paper, we have treated glass wafer surface using $CF_4$ gas for increase surface roughness and it has tested interfacial adhesion properties of UV resin/glass substrate interfaces by 4 point bending test. The interfacial adhesion energies by bare, 30, 60 and 90 sec surface treatments are 0.62, 1.4, 1.36 and 2 $J/m^2$, respectively. The test results showed quantitative comparisons of interfacial fracture energy (G) effect of glass wafer surface roughness.

  • PDF

BAYESIAN HIERARCHICAL MODEL WITH SKEWED ELLIPTICAL DISTRIBUTION

  • Chung, Youn-Shik;Dipak K. Dey;Yang, Tae-Young;Jang, Jung-Hoon
    • Journal of the Korean Statistical Society
    • /
    • v.32 no.4
    • /
    • pp.425-448
    • /
    • 2003
  • Meta-analysis refers to quantitative methods for combining results from independent studies in order to draw overall conclusions. We consider hierarchical models including selection models under a skewed heavy tailed error distribution proposed originally by Chen et al. (1999) and Branco and Dey (2001). These rich classes of models combine the information of independent studies, allowing investigation of variability both between and within studies, and incorporate weight function. Here, the testing for the skewness parameter is discussed. The score test statistic for such a test can be shown to be expressed as the posterior expectations. Also, we consider the detail computational scheme under skewed normal and skewed Student-t distribution using MCMC method. Finally, we introduce one example from Johnson (1993)'s real data and apply our proposed methodology. We investigate sensitivity of our results under different skewed errors and under different prior distributions.

On the Model Tests for POD Propulsion Ships

  • Go Seokcheon;Seo Heungwon;Chang Bong Jun
    • Journal of Ship and Ocean Technology
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2005
  • The procedures of model test and performance prediction for the CRP-POD propulsion ships, are studied. At the CRP-POD system, which are highly applicable to ultra large container carriers, RPM ratio of two propellers is not fixed, unlike conventional CRP system, and hence the power of each propeller must be predicted respectively. In this paper, a CRP-POD system is designed for 10,000 TEU class ultra large container carriers, and the characteristics of the CRP-POD system are experimentally studied. Finally, based on this study, the procedure of powering performance evaluation for CRP-POD propulsion ships is suggested. However, further studies on quantitative correction of the present procedure are required.

Performance Test on 2-Dimensional PIV and 3-Dimensional PIV Using Standard Images (표준영상을 이용한 2차원 PIV와 3차원 PIV 성능시험)

  • Hwang, Tae-Gyu;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1315-1321
    • /
    • 2004
  • Quantitative performance test on the conventional 2D-PIV and the hybrid angular 3D-PIV(Stereoscopic PIV) was carried out. LES Data sets on an impinging jet which are provided on the webpage(http://www.vsj.or.jp/piv) for the PIV Standard Project were used for the generation of virtual images. The generated virtual images were used for the 2D-PIV and 3D-PIV measurements test. It has been shown that the results obtained by 2D-PIV on average values are slightly closer to the LES data than those obtained by 3D-PIV, but the turbulent properties obtained by 2D-PIV are largely underestimated than those obtained by 3D-PIV.

Development of Testing Evaluation System far Analyzing Squeal Noise characteristic of the Brake System (제동장치 스퀼소음의 특성 분석을 위한 시험평가시스템 개발)

  • Park, Ho;Kim, Dong-Kyu;Kim, Heung-Seob
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.21-28
    • /
    • 2001
  • Analysis of squeal noise generated during brake operation is an important task for the improvement of brake noise prob-lem. By the use of measuring instrument and techniques, test and evaluation process are to be developed systematically in quantitative analysis. The cost far test and evaluation 7an be reduced, and the technical power can be raised by the devel- oped system.

  • PDF

The Measurement of Diffusion Coefficient of Fission Gases in Urania with Respect to O/M Ratio (화학당량에 따른 우라니아의 핵분열 기체 확산 계수 측정)

  • 김희문;박광헌;김봉구;주용선;김건식;송근우;홍권표;강영환
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.1
    • /
    • pp.99-107
    • /
    • 2003
  • The diffusion coefficient of Xe-133 was obtained from an annealing test. The specimens were made from a UO$_2$ single crystal powder with natural enrichment. Weight and grain size were 300mg and ($23\mu\textrm{m}$, respectively. Oxygen potentials were obtained from an oxygen sensor. Released fractions were obtained from both results of gamma scans and quantitative analysis with MCNP code, The annealing test was performed at three temperatures at once. Diffusion coefficients of Xe-133 were calculated using slope of Booth theory in each O/M ratios. Activation energy and the pre-exponential factor of the diffusion coefficient were obtained. The activation energy of near stoichiomeric $UO_2$ is 310 kJ/mol. The measured values of near stoichiometric $UO_2$ are very close to other data available. Diffusion coefficients increase with hyper-stoichiometry, due to higher concentration of cation vacancies.

Does Monetary Policy Regime Determine the Nature of the Money Supply?: Evidence from Seven Countries in the Asia-Pacific Region

  • Chai, Hee-Yul;Hahn, Sang B.
    • East Asian Economic Review
    • /
    • v.22 no.2
    • /
    • pp.217-239
    • /
    • 2018
  • This paper tests empirically the causal relationship between bank loans and the monetary base before and after the adoption of inflation targeting in seven Asia-Pacific countries using Toda-Yamamoto Granger non causality test and the bootstrap test for causality. The most striking finding is that the bank loans Granger cause the monetary base during the inflation targeting period in all the countries, except Japan, which was under the influence of the quantitative easing, whereas the causality appeared diverse before the inflation targeting regime. This result implies the need for the policy makers to take the endogenous nature of the money supply into account in the modern economy.

Detection of residual sulfamethazine in serum, urine and muscle of slaughtered pigs (도축돈의 혈청, 뇨 및 근육에서 sulfamethazine 잔류 조사)

  • 추금숙;오언평;최인열;송희종;채효석
    • Korean Journal of Veterinary Service
    • /
    • v.20 no.2
    • /
    • pp.161-168
    • /
    • 1997
  • This study was undertaken to determined the sulfamethazine residues In urine, serum and muscle of slaughtered pigs(n: 230) by the method of TLC, EEC-4-plate and HPLC. 1. Inhibition diameter characteristics of reference bacterial substance by EEC-4-plate method and antibacterial inhibition zone was appeared sulfonamides in BS pH 7.2 2. Residual sulfamethazine was detceted from 7 serum(3.04%) and 10 urine(4.35%) by TLC test and concentration of residues was higher In urine than serum. 3. Residual sulfamethazine was detected from 9 muscle(3.91%) by EEC-4-plate method. 4. Positive samples by TLC test and EEC-4-plate method were exceed 0.1ppm quantitative analysis from 7 muscle(3.04%).

  • PDF