Accurate quantitative precipitation estimation plays an important role in hydrological modelling and prediction. Instantaneous quantitative precipitation estimation (QPE) by utilizing the weather radar data is a great applicability for operational hydrology in a catchment. Previously, regression technique performed between reflectivity (Z) and rain intensity (R) is used commonly to obtain radar QPEs. A novel, recent approaching method which might be applied in hydrological area for QPE is Long Short-Term Memory (LSTM) Networks. LSTM networks is a development and evolution of Recurrent Neuron Networks (RNNs) method that overcomes the limited memory capacity of RNNs and allows learning of long-term input-output dependencies. The advantages of LSTM compare to RNN technique is proven by previous works. In this study, LSTM networks is used to estimate the quantitative precipitation from weather radar for an urban catchment in South Korea. Radar information and rain-gauge data are used to evaluate and verify the estimation. The estimation results figure out that LSTM approaching method shows the accuracy and outperformance compared to Z-R relationship method. This study gives us the high potential of LSTM and its applications in urban hydrology.
Recent adoption of the generalized sensor model to IKONOS and Quickbird satellite imagery have promoted various research activities concerning alternative sensor models which can replace conventional physical sensor models. For example, there are the Rational Function Model(RFM), the Direct Linear Transform(DLT) and the polynomial transform. In this paper, the DLT model which uses just a few number of GCPs was suggested. To evaluate the accuracy of the proposed DLT model, the RFM using 35 GCPs and the bias compensation method(Fraser et al., 2003) were compared with it. Quantitative evaluation of 3B positioning results were performed with independent check points and the digital elevation models(DEMs). In result, a 1.9- to 2.2-m positioning accuracy was achieved for modeling and DEM accuracy is similar to the accuracy of the other model methods.
PURPOSE. Comparing the accuracy of casts produced from digital workflow to that of casts produced from conventional techniques. MATERIALS AND METHODS. Whole arch alginate (ALG) and polyvinyl siloxane (PVS) impressions were taken with stock trays and custom trays, respectively. The ALG impressions were poured with type III dental stone, while the PVS impressions were poured with type IV dental stone. For the digital workflow, IOS impressions were taken and physical casts were produced by 3D printing. In addition, 3D printed casts were produced from images obtained from a laboratory scanner (LS). For each technique, a total of 10 casts were produced. The accuracies of the whole arch and separated teeth were virtually quantified. RESULTS. Whole arch cast accuracy was more superior for PVS followed by LS, ALG, and IOS. The PVS and ALG groups were inferior in the areas more susceptible to impression material distortion, such as fossae and undercut regions. The LS casts appeared to have generalized errors of minor magnitude influencing primarily the posterior teeth. The IOS casts were considerably more affected at the posterior region. On the contrary, the IOS and LS casts were more superior for single tooth accuracy followed by PVS and ALG. CONCLUSION. For whole arch accuracy, casts produced from IOS were inferior to those produced from PVS and ALG. The inferior outcome of IOS appears to be related to the span of scanning. For single tooth accuracy, IOS showed superior accuracy compared to conventional impressions.
TXRF는 시료전처리 없이 분말상 시료의 정량분석이 가능하여 토양시료를 효율적으로 분석할 수 있다. 기존의 내부표준법을 이용한 분석법은 매질 효과 및 형광신호의 겹침으로 인한 간섭 효과로 인해 정확도가 떨어진다. 이를 개선하기 위해 외부표준법을 적용하여 용액화한 토양시료와 분말상 토양시료를 분석하였다. 용액화한 토양시료의 경우 개별표준물질로 만든 표준용액으로 작성한 검량선으로 분석하였는데, 내부 및 외부표준법 간 유의미한 차이가 없었다. 반면 분말상 토양시료로 부유용액을 만들어 검량선을 작성한 후 이를 이용하여 분말상 토양시료를 분석한 결과, 전반적으로 외부표준법을 적용한 결과가 내부표준법의 그것에 비해 정확도가 높았다. 두 가지 표준토양시료로 교차검증한 결과, Al, Fe, K, Ca, Ti, Ba, Mn, Sr, Rb, Cu 등 10개의 원소들에 대해 ${\pm}20%$ 내외의 상대오차가 측정되었다.
Che, Hui-Je;Jung, Young-Jin;Lee, Seung-Hwan;Im, Chang-Hwan
대한의용생체공학회:의공학회지
/
제31권1호
/
pp.27-32
/
2010
Noninvasive detection of patients with probable Alzheimer's disease (AD) is of great importance for assisting a medical doctor's decision for early treatment of AD patients. In the present study, we have extracted quantitative electroencephalogram (qEEG) variables, which can be potentially used to diagnose AD, from resting eyes-closed continuous EEGs of 22 AD patients and 27 age-matched normal control (NC) subjects. We have extracted qEEG variables from mean phase coherence (MPC) and EEG coherence, evaluated for all possible combinations of electrode pairs. Preliminary trials to discriminate the two groups with the extracted qEEG variables demonstrated that the use of MPC as a supplementary or alternative measure for the EEG coherence may enhance the accuracy of noninvasive diagnosis of AD.
Forecasting have qualitative and quantitative methods. Quantitative one analyze macro-economic factors such as the rate of exchange, oil price, interest rate and also predict the micro-economic factors such as sales and demands. Applying various statistical methods depends on the type of data. when data has seasonality and trend, Time Series analysis is proper but when it has casual relation, Regression analysis is good for this. Time Series and Regression can be used together. This study investigate artificial neural networks which is predictive technique for casual relation and try to compare the accuracy of forecasting between regression analysis and artificial neural network.
개인에게 맞춤형 서비스를 제공하는 것이 중요해지면서 개인화 추천 시스템 관련 연구들이 끊임없이 이루어지고 있다. 추천 시스템 중 협업 필터링은 학계 및 산업계에서 가장 많이 사용되고 있다. 다만 사용자들의 평점 혹은 사용 여부와 같은 정량적인 정보에 국한하여 추천이 이루어져 정확도가 떨어진다는 문제가 제기되고 있다. 이와 같은 문제를 해결하기 위해 현재까지 많은 연구에서 정량적 정보 외에 다른 정보들을 활용하여 추천 시스템의 성능을 개선하려는 시도가 활발하게 이루어지고 있다. 리뷰를 이용한 감성 분석이 대표적이지만, 기존의 연구에서는 감성 분석의 결과를 추천 시스템에 직접적으로 반영하지 못한다는 한계가 있다. 이에 본 연구는 리뷰에 나타난 감성을 수치화하여 평점에 반영하는 것을 목표로 한다. 즉, 사용자가 직접 작성한 리뷰를 감성 수치화하여 정량적인 정보로 변환해 추천 시스템에 직접 반영할 수 있는 새로운 알고리즘을 제안한다. 이를 위해서는 정성적인 정보인 사용자들의 리뷰를 정량화 시켜야 하므로, 본 연구에서는 텍스트 마이닝의 감성 분석 기법을 통해 감성 수치를 산출하였다. 데이터는 영화 리뷰를 대상으로 하여 도메인 맞춤형 감성 사전을 구축하고, 이를 기반으로 리뷰의 감성점수를 산출한다. 본 논문에서 사용자 리뷰의 감성 수치를 반영한 협업 필터링이 평점만을 고려하는 전통적인 방식의 협업 필터링과 비교하여 우수한 정확도를 나타내는 것을 확인하였다. 이후 제안된 모델이 더 개선된 방식이라고 할 근거를 확보하기 위해 paired t-test 검증을 시도했고, 제안된 모델이 더 우수하다는 결론을 도출하였다. 본 연구에서는 평점만으로 사용자의 감성을 판단한 기존의 선행연구들이 가지는 한계를 극복하고자 리뷰를 수치화하여 기존의 평점 시스템보다 사용자의 의견을 더 정교하게 추천 시스템에 반영시켜 정확도를 향상시켰다. 이를 기반으로 추가적으로 다양한 분석을 시행한다면 추천의 정확도가 더 높아질 것으로 기대된다.
This study was investigated quantitative ultrasound (QUS) usage in Korea for the QUS quality control guidelines. A total of 344 questionnaires collected from July 24th to August 25th 2017 were analyzed. Questionnaires were created through user interviews, expert group advice, literature review and field observation. As a result of the general characteristics of quantitative ultrasound holding amounted to 81.98% of clinic and 6.69% of hospitals. The main user was radio-logical technologists as 31.39%. The contact methods of the gel pad (balloon) were the most used at 56.68% and the scan region was 91.9% of calcaneus. The quantitative ultrasound quality control cycle was 67.37% when the abnormality was found in the equipment, and 63.66% when the accuracy control was implemented according to the manual. The phantoms of QUS were 34.30% of the manufacturer's own phantoms. User of QUS had never received education for quality control of quantitative ultrasound as 62.20%. This study was expected to be useful when creating detailed quality control guidelines in the future, as well as guidelines for the quality control of Korea's standard quantitative ultrasound.
In this study, quantitative analysis for the quality evaluation of Salviae Miltiorrhizae Radix using HPLC/UV was developed. For quantitative analysis, six major bioactive compounds were determined. The separation conditions employed for HPLC/UV were optimized using ODS $C_{18}$ column ($250{\times}4.6\;mm$, $5\;{\mu}m$) with gradient condition of A (1% formic acid in $H_2O$) and B (acetonitrile : methanol : formic acid = 100 : 75 : 1) as the mobile phase at a flow rate of 1.0 mL/min and a detection wavelength of 280 nm. These methods were fully validated with respect to the linearity, accuracy, precision and recovery. The HPLC/UV method was applied successfully to the quantification of six major compounds in the Salviae Miltiorrhizae Radix. The results indicate that the established HPLC/UV method is suitable for the quantitative analysis.
The technical proposal suggested and published by MIC(Ministry of Information and Communication, henceforth MIC) contains too general assessment elements, which causes qualitative and subjective assessment of technical proposals. Thus, in terms of the technical proposal assessment. It lacks In fairness, validity and accuracy. Furthermore, it has a great deal of difficulty in assessment caused by the inconsistency between proposal planning and assessment methods. Also, each company has different writing format, so it is impossible to make use of its maneuvering data for the assessment. To overcome these weaknesses, our research focused on a quantitative evaluation on development organization, which is a part of organizational and administrative part of the technical proposal suggested and published by MIC. In this research, we divided development organization for the technical proposal into organization, teams, and team members, and then studied addition, deletion and merging for the assessment criteria. For the related study, we chose especially CMM(Capability Maturity Model) from a lot of international and national references, which is a model measuring the maturity of organization, and then we focused on Small-CMM which is available in the small-sized organization. We also suggested input form, description method, assessment elements for the quantitative assessment in the chosen developmental organization, and finally we proposed standard referencing criteria for the assessment. Our study concludes that our assessment method are valid and available in comparison with the previous Delphi method through a validity evaluation test.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.