• Title/Summary/Keyword: quantitative MR image

Search Result 75, Processing Time 0.03 seconds

Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1610-1615
    • /
    • 2019
  • Positron emission tomography (PET)/magnetic resonance (MR) scanning has the advantage of less additional exposure to radiation than does PET/computed tomography (CT). In particular, MR based attenuation correction (MR AC) can greatly affect the image quality of PET and is frequently obtained using various MR sequences. Thus, the purpose of the current study was to quantitatively compare the image quality between MR non-AC (MR NAC) and MR AC in PET images with three MR sequences. Percent image uniformity (PIU), percent contrast recovery (PCR), and percent background variability (PBV) were estimated to evaluate the quality of PET images with MR AC. Based on the results of PIU, 15.2% increase in the average quality was observed for PET images with MR AC than for PET images with MR NAC. In addition, 28.6% and 71.1% improvement in the average results of PCR and PBV respectively, was observed for PET images with MR AC compared with that with MR NAC. Moreover, no significant difference was observed among the average values using three MR sequences. In conclusion, the current study demonstrated that PET with MR AC improved the image quality and can be help diagnosis in all MR sequence cases.

Quantitative Analysis of Modified Fermi-Direc Filter applied to Clinical MR Image (임상 MR영상에 적용된 변형 Fermi-Direc필터의 정량적 평가)

  • Kim, Ki-Hong;Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.225-230
    • /
    • 2009
  • Filtering has been used to improve the image quality not only in MRI but in most image processing fields. In this paper, modified Fermi-Direc filter was transformed in various shapes, and then the optimum shape was designed. In addition, Newly made filter was applied in real clinic, which showed the obvious improvement in image quality. In conclusion, filtered image was superior to original image in contrast and sharpness. Then, this was proved by the histogram of R, G, B channel used for the quantitative analysis.

MR-based Partial Volume Correction for $^{18}$F-PET Data Using Hoffman Brain Phantom

  • Kim, D. H.;Kim, H. J.;H. K. Jeong;H. K. Son;W. S. Kang;H. Jung;S. I. Hong;M. Yun;Lee, J. D.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.322-323
    • /
    • 2002
  • Partial volume averaging effect of PET data influences on the accuracy of quantitative measurements of regional brain metabolism because spatial resolution of PET is limited. The purpose of this study was to evaluate the accuracy of partial volume correction carried out on $^{18}$ F-PET images using Hoffman brain phantom. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices of the same phantom. All the MR slices of the phantom were then segmented to be binary images. Each of these binary images was convolved in 2 dimensions with the spatial resolution of the PET. The original PET images were then divided by the smoothed binary images in slice-by-slice, voxel-by-voxel basis resulting in larger PET image volume in size. This enlarged partial volume corrected PET image volume was multiplied by original binary image volume to exclude extracortical region. The evaluation of partial volume corrected PET image volume was performed by region of interests (ROI) analysis applying ROIs, which were drawn on cortical regions of the original MR image slices, to corrected and original PET image volume. From the ROI analysis, range of regional mean values increases of partial volume corrected PET images was 4 to 14%, and average increase for all the ROIs was about 10% in this phantom study. Hoffman brain phantom study was useful for the objective evaluation of the partial volume correction method. This MR-based correction method would be applicable to patients in the. quantitative analysis of FDG-PET studies.

  • PDF

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.

Comparison of Pulsed Arterial Spin Labeling with Conventional Perfusion MRI in Moyamoya Disease Patient (모야모야병에서 펄스 동맥 스핀 표지 영상과 고식적인 관류자기공명영상의 비교)

  • Jo, Gwang-Ho;Bae, Sung-Jin
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.427-433
    • /
    • 2007
  • This study was conducted to investigate the usefulness of PASL image technique through visual and quantitative assessment by dividing CBF image, conventional perfusion magnetic resonance image, anterior cerebral artery, middle cerebral artery and posterior cerebral artery into 6 territories both right and left in moyamoya disease. In visual assessment, the scope of decreased perfusion in the PASL CBF image and conventional perfusion MR CBF image agreed with the position of deficiency in the MR image. The quantitative assessment, showed that the scope and position of decreased perfusion accord with both in the PASL CBF image and the existing conventional perfusion MR CBF image but the assessment of measuring the quantity of perfusion according to signal intensity showed a little difference.

  • PDF

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF

Improved Focal Liver Lesion Detection by Increasing Flip Angle During Gadoxetic Acid-Enhancement in MRI (Gadoxetic acid 조영증강 자기공명영상에서 숙임각 변화에 따른 국소 간종양 검출능 비교)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2015
  • To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)'s enhanced MR imaging with a flip angle (FA) of $30^{\circ}$ compared with a $11^{\circ}$. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA $11^{\circ}$ and $30^{\circ}$ images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA $30^{\circ}$ images was found to be superior than FA $11^{\circ}$, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA $30^{\circ}$ image(p<0.05) was better than FA $11^{\circ}$ therefore, the FA $30^{\circ}$ improves the focal liver lesion detection. FA $30^{\circ}$ of MR image can detect liver lesion more sensitively than the existing $FA11^{\circ}$ image after GA contrast enhancement at 15 minute time point.

A COMPARATIVE STUDY ONMAGNETIC RESONANCE IMAGE AND SECTOGRAPH OF HUMAN TNJ (악관절의 자기공명영상과 시상단층 방사선촬영상에 관한 비교연구)

  • Lee, Sung-Bok;Choi, Dae-Gyun;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.249-270
    • /
    • 1993
  • For understanding of anatomy, physiology, and diseases of human TMJ, it is required to evaluate quantitatively the movement of the disc and condyle head of mandible. The histologic section of cadaver TMJ were examined, and the magnification of the MR image and its details of anatomy were evaluated. And then a quantitative analytic method, by comparing the Sectograph and the MR image of vital human TMJ, was proposed. For this study, 15 subjects(Male, 24~35years) were selected from a prosthodontic examination randomly, and each subject’s five interocclusal rubber registration records were made on the ICP, and 5, 10, 15, and 20mmjaw opening positions. All subjects were radiographed with a Denar Quint Sectograph Image System(Denar Corp., USA), and imaged with a MRP-20EX MR Image System(0.2T, Permanent Magnet Type, Hitachi Medical Corp., Japan) using an 100mm diameter bilateral type surface coil. These images were traced on the acetate tracing paper, and analyzed In this study, the findings led to the following conclusions. 1. In comparison of the histologic section of autopsy specimen with the MR image at the same section, the size(dimension) of MR image was 70% of the real one. It was possible to recognize the shape of articular disc, anterior and posterior attachments, and adjacent soft tissues, because of the excellent reproducibility of anatomical structure. 2. When we compared the amount of joint space on MR image with that of joint space on sectograph, the amount of joint space on sectograph was significantly greater than that of joint space on MR image, except at the top of condylar head. 3. The position of minimum joint space on sectograph at intercuspal position didn't coincide with the middle position of articular disc on MR image, and was approximately in the anterior third of posterior band of articular disc. 4. The amount of condylar movement on MR image at opening movement was greater than that of articular disc movement. From Intercuspal position to 5mm jaw-opening movement, the condylar movement showed hinge one, and over the range 5mm jaw-opening it suggested hinge & translatory one. 5. In terms of area variation of articular disc measured on MR image in sagittal plane, the area of posterior band increased with increasing the amount of Jaw opening, but the area of anterior band decreased conversely.

  • PDF

The Value of Three-Dimensional Reconstructions of MRI Imaging using Maximum Intensity Projection Technique (유방 MRI의 최대강도투사 기법에 의한 3차원 재구성 영상의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag;Hong, In-Sik;Kim, Hyun-Joo;Jang, Hyun-Cheol;Park, Cheol-Soo;Park, Tae-Nam
    • Journal of Digital Contents Society
    • /
    • v.12 no.2
    • /
    • pp.157-164
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of 3D reconstruction images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, subtraction images and 3D reconstruction images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The 3D reconstruction images showed higher SNR at the lesion area, ductal area, and fat area that of the subtraction image. In addition, the CNR were not significantly different in the lesion area itself between the subtraction images and 3D reconstruction images.

The quantitative analysis of Diffusion Weighted Imaging in Breast MRI (유방 MRI 검사에서 확산강조영상의 정량적 분석)

  • Cho, Jae-Hwan;Kim, Hyeon-Ju;Hong, Yin-Sik;Lee, Hae-Kag
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.149-154
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of diffusion weighted images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, diffusion weighted images and ADC map images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The diffusion weighted images showed higher SNR and CNR at the lesion area. In addition, the ADC values were lower at the lesion area.