• Title/Summary/Keyword: quality-certificated

Search Result 25, Processing Time 0.025 seconds

A Framework for the IFC Interoperability Test Method to Support BIM (BIM 지원을 위한 IFC모델 호환성 검사 방법에 관한 기초 연구)

  • Kang, Hoon-Sig;Lee, Ghang;Shin, Yun-Ah
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.674-677
    • /
    • 2008
  • The Architecture, engineering, & construction (AEC) industry domains have grown more complex and larger, BIM is a digital representation of a building to facilitate the exchange and development of construction information integration and interoperability. Industry Foundation Classes (IFCs), under development by International Alliance for Interoperability (IAI), represent the part of buildings or elements of a process. IFC has been adopted as a central information repository in order to deliver integrated building information. Other BIM software could open the IFC file, recognize standard objects such as walls, window, and doors as building components. The IFC standard is generally agreed to be of high quality and is widely implemented in software. However, sometimes, information distortion or information toss occurrs during information exchang. The IAI Model Support Group (IAI-MSG) offers the opportunity to certify IFC-compliant applications based on a structuralized approach. However, IFC interoperability error also have occurred by using certificated tools. As project participants exchange BIM information by using BIM software they will need a reliable and efficient exchange of information. In this paper, previous interoperability tests were analyzed, and we propose a new concept in interoperability test.

  • PDF

A Study on the Development of Power-Line EMI Filter for the Prevention of Conduction Noise by Coil Loads. (코일성 부하에 의한 전도 노이즈 방지 목적의 전원용 EMI필터 개발 연구)

  • Kim, Byeong Jun;Joo, Jae-hun;Kim, Jin Ae;Baek, Pan Keun;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.175-179
    • /
    • 2009
  • this paper proposes a filter design that makes to be satisfied EMC spec. in reliability test of analogue switch for electronic equipment and air conditioning load unit. A designed electromagnetic wave filter was applied to minimize an mutual interference and surrounding environment and improve the product's quality being satisfied to EMC standard. By simulation, using a spectrum analyzer at the 30MHz~1GHz band, ISO/JASO standard frequency range, and simplified EMI chamber, energy distribution of a specific frequency band was analyzed and the capacity of the element which composed the filter was determined in order to implement the most suitable electromagnetic wave filter.In fact, it was certificated that noise decrease by filter addition to the analogue switch for electronic equipment and air conditioning load unit in Certification Authority, and confirmed that the unit is carried out a normal action without electromagnetic wave interference.

  • PDF

A Study on Plant Certification Program for Precast Concrete Products (프리캐스트 콘크리트 제품의 공장 인증 제도에 관한 연구)

  • Kim, Hyoung-Do;Lee, Sang-Sup;Park, Keum-Sung;Bae, Kyu-Woong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.131-138
    • /
    • 2014
  • The steel structure fabrication plant certification program was enacted as a part of the construction technology management act, article 24-3, to improve the quality of steel construction after the decay falling accident of Seongsu Bridge in 1994. However, the national certification program for structural precast concrete that is a prefabricated construction products produced by casting concrete in plant is not implemented yet. So, to introduce the proper certification system for precast concrete, the quality certification programs of North America, Europe and Japan are surveyed. In North America, the organizations that manage the plant certification programs are PCI, NPCA, CPCI and so on. Sales of precast concrete elements in Europe are governed by the construction products regulation 305/2011. Therefore, CE marking is mandatory from July 2013 for all construction products including precast concrete. In Japan, precast concrete products used in civil engineering are certificated by JIS mark, product certification system and plants for manufacturing precast concrete building elements are audited by Japan Prefabricated Construction Suppliers and Manufacturers Association. Based on these survey studies, in this paper is described an adaptation of precast concrete plant certification to comport with the certification system in Korea.

The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay (방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가)

  • Noh, Gyeong-Woon;Kim, Tae-Hoon;Kim, Ji-Young;Kim, Hyun-Joo;Lee, Ho-Young;Choi, Joon-Young;Lee, Byoeng-Il;Choe, Jae-Gol;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • Purpose: To establish accurate external quality assurance (EQA) test, cross institutional and modality tests were performed using WHO certificated reference material (CRM) and same pooled patients serum. Materials and Methods: Accuracy and precision were evaluated using CRM and pooled patients' serum for AFP, CEA, PSA, CA 125, CA 19-9, T3, T4, Tg, TSH. To evaluate the accuracy and precision, recover test and coefficient variation were measured. RIA test were performed in major 5 RIA laboratory and EIA (CLIA) test were done in 5 major EIA laboratory. same sample of CRM and pooled serum were delivered to each laboratory. Results: In 2009, mean precision of total tumor marker of RIA was $14.8{\pm}4.2%$ and that of EIA(CLIA) was $19.2{\pm}6.9%$. In 2010, mean precision of 5 tumor marker and T3, T4, Tg, TSH was $13.8{\pm}6.1%$ in RIA and $15.5{\pm}7.7%$ in EIA (CLIA). There was no significant difference between RIA and EIA. In RIA, the coefficient variations (CV) of AFP, CEA, PSA, CA 125, T3, T4, TSH were within 20%. The CV of CA 19-9 was over 20% but there was no significant difference with EIA (CLIA) (p=0.345). In recovery test using CRM, AFP, PSA, T4, TSH showed 92~103% of recovery in RIA. In recovery test using commercial material, CEA, CA 125, CA 19-9 showed relatively lower recovery than CRM but there was no significant difference between RIA and EIA (CLIA). Conclusion: By evaluating the precision and accuracy of each test, EQA test could more accurately measured the quality of each test and performance of laboratory.

  • PDF

A Study on the concern and change of form and matter in medical conversation by writing (의학필담 형식과 내용의 상관성 및 변천에대한 연구 - '~ 록(錄)', '~ 의담(醫談)', '~ 필어(筆語)'를 중심으로 -)

  • Kim, Hyung-Tae
    • (The)Study of the Eastern Classic
    • /
    • no.37
    • /
    • pp.217-248
    • /
    • 2009
  • 'Pil-dam-chang-su-jib'(collection of conversation by writing about poetry or sentences) which was remained in Japan through the dispatching of Tong-sin mission belong to the Joseon dynasty is a valuable historical records directly to verify sincere relationships with Korea and Japan in the past. At the center of the 'Pil-dam-chang-su-jib', a conversation of senators who was technocrat both countries at that time was not a little contained. Because they need to exchange information and opinions which they had been curious at an appointed hour, the most impending medical problems of that period had to be brought out in the senator's 'Pil-dam-chang-su-jib' and the value of material is high as much. If you examine the 'Pil-dam' records which was exchanged from senators to senators of both countries at that time, you can directly confirm the universality and difference of the medical science and medicine tradition of various East Asian countries. The purpose of a paper was in consolidation to a base of translation and investigation hereafter to consider the characters embodied in medical conversation in the first half of $18^{th}$ centuries. '~ Rok(錄)' can be an opportunity to organize the customs history through the studying an illness, medicines and a remedy. The necessity of the investigation about medical related conversation by writing is in this place. '~ Ui-dam(醫談)' is considering with the all factors above, the first half of 18th century's medical conversation materials are certificated remarkably valuable materials to the cultural history around the physician at that time. '~ Pil-ur(筆語)' is to use of questions and answers form gives presence and reality at the conversation by writing. So, conversation was let the readers to gain the feeling of movement. Also, the contents are substantially reflected the long history of Eastern medical and revealed medical science, treatment reality at that time. Not correspondent with normal collection of conversation by writing, the medical conversation by writing shows a special quality at rich material to confirm the technocrat's identity. The first half of $18^{th}$ century medical conversation by writing had been a foundation of the rational description system at the coming medical conversation to change the description system according to the envoy's coming situation.