• Title/Summary/Keyword: quality of pitch

Search Result 330, Processing Time 0.022 seconds

A Study on the Improvement of the Image Quality for UAV Using Drift Compensation (편류보정을 통한 무인항공기 영상품질 향상에 관한 연구)

  • Lee, Mal-Young
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.3
    • /
    • pp.405-412
    • /
    • 2013
  • Purpose: In this paper, the improvement of the image quality is investigated. The image quality is degraded by the drift phenomenon of EO/IR (Electro-Optical/Infrared) device on UAV. The drift phenomenon means that the image of EO/IR equipment on UAV(Unmanned Aerial Vehicle) moves to the unintended direction. This phenomenon should be improved for successful flight mission. Methods: To improve the drift phenomenon, the drift compensation method, the combination algorithm of FMC(Forward Motion Compensation) and AMC(Angular Motion Compensation) method, are introduced to calculate pitch and azimuth angle. Result values of pitch and azimuth angle are used for the improvement of image quality in EO/IR control logic. Results: The image quality is quantitatively improved more than 15 times through field test data of flight. Conclusion: Using the drift compensation technique, the image quality for EO/IR equipment is improved over 15 times than existing methods. This means the user of UAV with EO/IR device can perform a successful mission by keeping the line of sight for the target accurately.

Sound Quality Characteristics of Refrigerator Noise in relation to Autocorrelation Function and Psychoacoustical Parameters (ACF 및 심리음향 파라미터에 의한 냉장고 소음의 Sound qualify 평가)

  • Jeon, Jin-Yong;Sato, Shin-ichi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.661-665
    • /
    • 2006
  • This study investigates objective and subjective evaluations of refrigerator noise. To describe the fluctuations like a click, a rapid increase of sound level, a change of pitch, a transition into the stationary and ending phase, the psychoacoustical and autocorrelation function(ACF) parameters have been employed. First, subjective evaluation of the noisiness of 24 kinds of refrigerators was conducted. Then, the relationship between objective measures of the refrigerator noise on perceived noisiness was examined with multiple regression analyses. Sound Quality Indices using the psychoacoustical and ACF parameters were also developed. The important psychoacoustical parameters for evaluating noisiness are loudness and roughness of stationary phase. The relationship between the noisiness and the ACF parameters shows that sound energy ${\Phi}(0)$ and its fluctuations are important. Also, refrigerator sounds that had a fluctuation of pitch were rated as more annoying. The fluctuation of pitch is expressed by ${\tau}_1\;and\;{\Phi}_1$ defined by the delay time and the amplitude of the first peak of the ACF.

  • PDF

Emotion Recognition Based on Frequency Analysis of Speech Signal

  • Sim, Kwee-Bo;Park, Chang-Hyun;Lee, Dong-Wook;Joo, Young-Hoon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.2 no.2
    • /
    • pp.122-126
    • /
    • 2002
  • In this study, we find features of 3 emotions (Happiness, Angry, Surprise) as the fundamental research of emotion recognition. Speech signal with emotion has several elements. That is, voice quality, pitch, formant, speech speed, etc. Until now, most researchers have used the change of pitch or Short-time average power envelope or Mel based speech power coefficients. Of course, pitch is very efficient and informative feature. Thus we used it in this study. As pitch is very sensitive to a delicate emotion, it changes easily whenever a man is at different emotional state. Therefore, we can find the pitch is changed steeply or changed with gentle slope or not changed. And, this paper extracts formant features from speech signal with emotion. Each vowels show that each formant has similar position without big difference. Based on this fact, in the pleasure case, we extract features of laughter. And, with that, we separate laughing for easy work. Also, we find those far the angry and surprise.

A Study on Improving Voice Quality and Pitch Searching of the VSELP Coder (VSELP 부호화기의 음질 및 주기탐색 개선에 관한 연구)

  • 성기철;문상재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.4
    • /
    • pp.740-749
    • /
    • 1994
  • This paper presents method for improving the performance of the VSELP speech coder. The hybrid method is employed for pitch period searching. Pitch searching time is reduced and pitch detection error, caused by quantization error of excitation signal of encoder in VSELP coder, is reduced by this method. This paper also adopts a pitch period enhancement filter and an adaptive first order filter. In this result, pitch period searching time is reduced to 26%, and MOS of reconstructed speech signal is increased by 3.19 to 4.04.

  • PDF

On a Pitch Alteration Technique by Cepstrum Analysis of Flattened Excitation Spectrum (평탄화된 여기 스펙트럼에서 켑스트럼 피치 변경법에 관한 연구)

  • 조왕래
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.159-162
    • /
    • 1998
  • Speech synthesis coding is classified into three categories: waveform coding, source coding and hybrid coding. To obtain the synthetic speech with high quality, the synthesis by waveform coding is desired. However, it is difficult to apply waveform coding to synthesis by syllable or phoneme unit, because it does not divide the speech into excitation and formant component. Thus it is required to alter the excitation in waveform coding for applying waveform coding to synthesis by rule. In this paper we propose a new pitch alteration method that minimizes the spectrum distortion by using the behavior of cepstrum. This method splits the spectrum of speech signal into excitation spectrum and formant spectrum and transforms the excitation spectrum into cepstrum domain. The pitch of excitation cepstrum is altered by zero insertion or zero deletion and the pitch altered spectrum is reconstructed in spectrum domain. As a result of performance test, the average spectrum distortion was below 2.29%.

  • PDF

On A Pitch Alteration using the Waveform Symmetry with Time - Frequency Conversion (시간 - 주파수 변환에 의한 파형 대칭 피치변경법)

  • 박형빈
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.147-150
    • /
    • 1998
  • In the case of speech synthesis, the waveform coding method with high quality is mainly used to the synthesis by analysis. Because the parameters of this coding method are not classified as both excitation and vocal tract parameters, it is difficult to apply the waveform coding method to the synthesis by rule. Thus, in order to apply the waveform coding method to the synthesis by rule, a pitch alteration is required for the prosody control. In the speech synthesis method by the conventional PSOLA technique, applying symmetric window function to asymmetric speech waveform, it occurs the unbalance phenomenon of energy according to the overlapped degree of pitch interval adjustment. In this paper to overcome the unbalance phenomenon of energy, we proposed a new method that can convert asymmetric waveform to symmetric one by time-frequency conversion. As a result, we can obtain an average spectrum distortion ratio with 6.38% according to the pitch alteration ratio.

  • PDF

A Study on Radiation Dose and Image Quality using Dual Energy Computed Tomography ECG Gating High Pitch Chest Pain Protocol Mode (이중 에너지 전산화 단층촬영 ECG Gating High Pitch Chest Pain Protocol 모드를 이용한 방사선량과 영상 품질에 관한 연구)

  • Kim, Gyeong-Rip;Sung, Soon-Ki;Kim, Chang-Hyeun;Kwak, Jong-Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.7-13
    • /
    • 2022
  • This study compared the aortic root image by using the ECG gating and non-ECG gating methods. We observed the presence or absence of progression of the aortic root image in the images examined by the high pitch (flash) chest pain protocol method and in the patients tested without ECG gating by the conventional method. The AAPM phantom was scanned by using high pitch (flash) chest pain protocol and general chest pain protocol. CTDI values were compared. By ECG gating, the blurring of ascending aorta was significantly reduced compared to the existing non-ECG gating test method, and the image quality of the aortic root was improved. Within the parametar range that did not show differences in noise, uniformity, and high contrast resolution, CTDI values were lower when tested with the high-pitch chest pain protocol. It was found that there is an advantage in dose reduction, and if it is applied and applied to diagnostic fields such as dissection using the dose reduction mode in the cardiac field, it is a very important test for patients who need rapid diagnosis and prompt treatment as well as a dramatic reduction in exposure dose. It is presumed to be a method.

Development of pitch control system for 2WM wind turbine (2MW급 풍력발전용 블레이드 피치 제어 시스템 개발)

  • Choi, Hee-young;Ryu, Ji-su;Lee, Sang-ho
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.285-286
    • /
    • 2011
  • Wind turbine system is converting wind energy into electric energy. In nature, torque of the blade is nonlinear function. To get a high quality electric power, system needs control of blade angle. The control of a blade is divided into a stall regulation type and a pitch control type. Pitch control type is more expensive and complicated, but it can make torque of the blade in accordance with variable wind. This paper shows 2MW pitch control system's hardware and electric part.

  • PDF

A Study on the Pitch Alteration Technique by Subband Scaling in Speech Signal (서브밴드 스케일링에 의한 음성신호의 피치변경법에 관한 연구)

  • Kim, Young-Kyu;Bae, Myung-Jin
    • Speech Sciences
    • /
    • v.10 no.4
    • /
    • pp.137-147
    • /
    • 2003
  • Speech synthesis can classify by synthesis way, that is waveform coding, source coding and mixture coding. Specially, waveform coding is suitable for high quality synthesis. However, it is not desirable by synthesis techniques of syllable or phoneme unit because it do not separate and handles excitation and formant part. Therefore, there is a need for pitch alteration method applied in synthesis by the rule in waveform coding. This study propose about pitch alteration method that use spectrum scaling after do to flatten spectra by subband linear approximation to minimize spectrum distortion. This paper show evaluation whether show excellency of some measure compared with LPC, Cepstrum, lifter function and method that propose. estimation method seeks distribution of each flattened signal and measured degree of flattened spectra Signal flattened is normalized, So that highest point amounts to zero, and distribution of signal ,whose average is zero, is calculated. this show result that measure the spectrum distortion rate to estimate performance of method that propose. The average spectrum distortion rate was kept below the average 2.12%, so the method that propose is superiors than existent method.

  • PDF

On a Performance Evaluation of the Pitch Alteration Techniques of speech waveform coding (피치 변경법의 성능평가)

  • Kim, Hong;Bae, Seong-Gyun;Jo, Wang-Rae;Bae, Myung-Jin
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06c
    • /
    • pp.103-106
    • /
    • 1994
  • Generally we are used to apply waveform coding method obtaining the high quality synthesized speech. But we have to solve the problems, memory capacity and pitch alteration, for applying the waveform coding method to speech synthesis by rule. The former problem is conquered by improving the integrated semiconductor technology, but the latter problem remains. In this paper, we compare the methods that have proposed for pitch alteration in our laboratory until now. These methods are not change properties of vocal tract formants and only altered the pitch halving method, 1.14% for cepstrum analysis method, and 2.36% for hamonics compensated with the phase method.

  • PDF