• Title/Summary/Keyword: quality difference

Search Result 7,772, Processing Time 0.038 seconds

The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs (분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가)

  • Hong, soon gi;Son, sang joon;Moon, joon gi;Kim, bo kyum;Lee, je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2016
  • Purpose : To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. Materials and Methods : This study was based on 5 prostate cancer patients who had IMRT(total dose: 70Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by appling the first treatment plan to each image. Over 5 fractions, the total dose for PTV was $V_{36.25}$ Gy $${\geq_-}$$ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured $V_{100%}$, $V_{95%}$, $V_{90%}$ for CTV and $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$ of rectum and bladder. Results : All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$ in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. Conclusion : There was no case that the value from average of five fractions is over the dosimetric limits. However, dosimetric errors of rectum and bladder in each fraction was significant. Therefore, the precise delivery is needed in case of prostate SBRT. The real-time tracking and adaptive plan is necessary to meet the precision delivery.

  • PDF

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF

The Market Segmentation of Coffee Shops and the Difference Analysis of Consumer Behavior: A Case based on Caffe Bene (커피전문점의 시장세분화와 소비자행동 차이 분석 : 카페베네 사례를 중심으로)

  • Yu, Jong-Pil;Yoon, Nam-Soo
    • Journal of Distribution Science
    • /
    • v.9 no.4
    • /
    • pp.5-13
    • /
    • 2011
  • This study provides analysis of the effectiveness of domestic marketing strategies of the Korean coffee shop "Caffe Bene". It bases its evaluation on statistical outputs of 'choice attributes,' "market segmentation," demographic characteristics," and "satisfaction differences." The results are summarized in four points. First, five choice attributes were extracted from factor analysis: price, atmosphere, comfort, taste, and location; these are related to coffee shop selection behavior. Based on these five factors, cluster analysis was conducted, with statistical results classifying customers into three major groups: atmosphere oriented; comfort oriented; and taste oriented. Second, discriminant analysis tested cluster analysis and showed two discriminant functions: location and atmosphere. Third, cross-tabulation analysis based on demographic characteristics showed distinctive demographic characteristics within the three groups. Atmosphere oriented group, early-20s, as women of all ages was found to be 'walking down the street 'and 'through acquaintances' in many cases, as the cognitive path, and mostly found the store through 'outdoor advertising', and 'introduction'. Comfort oriented group was mainly women who are students in their early twenties or professionals, and appeared as a group to be very loyal because of high recommendation to other customers compared to other groups. Taste oriented group, unlike the other group, was mainly late-20s' college graduates, and was confirmed, as low loyalty, with lower recommendation activity. Fourth, to analyze satisfaction differences, one-way ANOVA was conducted. It shows that groups which show high satisfaction in the five main factors also show high menu satisfaction and high overall satisfaction. This results show that segmented marketing strategies are necessary because customers are considering price, atmosphere, comfort, taste, location when they choose coffee shop and demographics show different attributes based on segmented groups. For example, atmosphere oriented group is satisfied with shop interior and comfort while dissatisfied with price because most of the customers in this group are early 20s and do not have great financial capability. Thus, price discounting marketing strategies based on individual situations through CRM system is critical. Comfort oriented group shows high satisfaction level about location and shop comfort. Also, in this group, there are many early 20s female customers, students, and self-employed people. This group customers show high word of mouth tendency, hence providing positive brand image to the customers would be important. In case of taste oriented group, while the scores of taste and location are high, word of mouth score is low. This group is mainly composed of educated and professional many late 20s customers, therefore, menu differentiation, increasing quality of coffee taste and price discrimination is critical to increase customers' satisfaction. However, it is hard to generalize the results of study to other coffee shop brand, because this study have researched only one domestic coffee shop, Caffe Bene. Thus if future study expand the scope of locations, brands, and occupations, the results of the study would provide more generalizable results. Finally, research of customer satisfactions of menu, trust, loyalty, and switching cost would be critical in the future study.

  • PDF

An Intelligence Support System Research on KTX Rolling Stock Failure Using Case-based Reasoning and Text Mining (사례기반추론과 텍스트마이닝 기법을 활용한 KTX 차량고장 지능형 조치지원시스템 연구)

  • Lee, Hyung Il;Kim, Jong Woo
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.1
    • /
    • pp.47-73
    • /
    • 2020
  • KTX rolling stocks are a system consisting of several machines, electrical devices, and components. The maintenance of the rolling stocks requires considerable expertise and experience of maintenance workers. In the event of a rolling stock failure, the knowledge and experience of the maintainer will result in a difference in the quality of the time and work to solve the problem. So, the resulting availability of the vehicle will vary. Although problem solving is generally based on fault manuals, experienced and skilled professionals can quickly diagnose and take actions by applying personal know-how. Since this knowledge exists in a tacit form, it is difficult to pass it on completely to a successor, and there have been studies that have developed a case-based rolling stock expert system to turn it into a data-driven one. Nonetheless, research on the most commonly used KTX rolling stock on the main-line or the development of a system that extracts text meanings and searches for similar cases is still lacking. Therefore, this study proposes an intelligence supporting system that provides an action guide for emerging failures by using the know-how of these rolling stocks maintenance experts as an example of problem solving. For this purpose, the case base was constructed by collecting the rolling stocks failure data generated from 2015 to 2017, and the integrated dictionary was constructed separately through the case base to include the essential terminology and failure codes in consideration of the specialty of the railway rolling stock sector. Based on a deployed case base, a new failure was retrieved from past cases and the top three most similar failure cases were extracted to propose the actual actions of these cases as a diagnostic guide. In this study, various dimensionality reduction measures were applied to calculate similarity by taking into account the meaningful relationship of failure details in order to compensate for the limitations of the method of searching cases by keyword matching in rolling stock failure expert system studies using case-based reasoning in the precedent case-based expert system studies, and their usefulness was verified through experiments. Among the various dimensionality reduction techniques, similar cases were retrieved by applying three algorithms: Non-negative Matrix Factorization(NMF), Latent Semantic Analysis(LSA), and Doc2Vec to extract the characteristics of the failure and measure the cosine distance between the vectors. The precision, recall, and F-measure methods were used to assess the performance of the proposed actions. To compare the performance of dimensionality reduction techniques, the analysis of variance confirmed that the performance differences of the five algorithms were statistically significant, with a comparison between the algorithm that randomly extracts failure cases with identical failure codes and the algorithm that applies cosine similarity directly based on words. In addition, optimal techniques were derived for practical application by verifying differences in performance depending on the number of dimensions for dimensionality reduction. The analysis showed that the performance of the cosine similarity was higher than that of the dimension using Non-negative Matrix Factorization(NMF) and Latent Semantic Analysis(LSA) and the performance of algorithm using Doc2Vec was the highest. Furthermore, in terms of dimensionality reduction techniques, the larger the number of dimensions at the appropriate level, the better the performance was found. Through this study, we confirmed the usefulness of effective methods of extracting characteristics of data and converting unstructured data when applying case-based reasoning based on which most of the attributes are texted in the special field of KTX rolling stock. Text mining is a trend where studies are being conducted for use in many areas, but studies using such text data are still lacking in an environment where there are a number of specialized terms and limited access to data, such as the one we want to use in this study. In this regard, it is significant that the study first presented an intelligent diagnostic system that suggested action by searching for a case by applying text mining techniques to extract the characteristics of the failure to complement keyword-based case searches. It is expected that this will provide implications as basic study for developing diagnostic systems that can be used immediately on the site.

The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.

Factors Affecting Pregnancy Rates on Transfer of Pronuclear Microinjected Embryos in Korean Black Goats (전핵 미세 주입법으로 생산된 한국흑염소 수정란의 이식 조건이 수태율에 미치는 영향)

  • Choi, Y.S.;Shin, H.G.;Jang, S.K.;Yang, H.S.;Lee, O.K.;Lee, D.S.;Cho, J.K.;Shin, S.T.
    • Journal of Embryo Transfer
    • /
    • v.22 no.1
    • /
    • pp.53-61
    • /
    • 2007
  • This study was investigated factors affecting the pregnancy rates after transfer of pronuclear microinjected embryos for the production of transgenic Korean black goats. Embryo transfer was carried out in 343 recipient Korean black goats from September 1999 to June 2000. Estrus was induced by the insertion of intravaginal progesterone devices $CIDR^(R)$ for 2 weeks. A single injection of 400 IU equine chorionic gonadotropin was administered at 48h before $CIDR^(R)$ removal to increase the proportion of does cycling and ovulation rate. Good quality embryos were prepared by microinjection of DNA into the pronuclei of fertilized goat oocyte and cultured in vitro. Pronuclear microinjected $1{\sim}8$ cell stage embryos were surgically transferred into the oviducts of the recipient at day 4 or 5 following $CIDR^(R)$ removal, and morula to blastocyst stage embryos were surgically transferred into uterus at day 9. Pregnancy was diagnosed by transrectal ultrasound scanning at $20{\sim}30d$ and 8 weeks following embryo transfer. The pregnancy rate was affected by several factors, such as estrus induction, the number of previous transfer, transfer site, stage of CL (corpus luteum), the number of recipient CL, stage of embryos and the number of transferred embryo. The pregnancy rate was significantly higher in recipients that came into estrus naturally than recipients that induced to come into estrus with $CIDR^(R)$(59.1% vs. 36.8%; P<0.05). The pregnancy rate was higher when the embryos were transferred into the left oviduct than transferred into the right oviduct (42.9% vs. 35.3%; P<0.05). The pregnancy rate of recipients with $CH_1$ (early) stage corpus hemorrhagicum in ovary was hi틴or than recipient with $CH_3$ (late) stage hemorrhagicum (47.5% vs. 17.9%; P<0.01). Higher pregnancy rates were obtained by transfer of 1-cell stage embryos into oviduct while late blastocysts (51.6% vs. 66.7%; P<0.01) into uterus. The pregnancy rates when 3 embryos were transferred to recipients were significantly higher than when 2 embryos we.e transferred (47.6% vs. 27.0%; P<0.05). Although there were no significant difference among the group, adhesion of reproductive organs, uterine size, ovulation rate of recipients, presence of large follicle and difficulty of transfer affected pregnancy rate of recipient. Higher pregnancy rates were obtained in the recipients with $8{\sim}15m$ diameter uterine horn as compared to the recipients with <5m diameter or >20mm diameter uterine hem (38.9%, 20% vs. 18.2%), in the recipients with large follicle in the ovulated ovary ipsilaterally (53.6% vs. 37.1%) and in the transfer which was carried out easily (39.2% vs. 27.8%, 0%). In conclusion, the high rate of pregnancy was achieved following transfer of pronuclear microinjected embryos when three or four 1-cell stage embryos were transferred into oviduct with $CH_1$ stage corpus hemorrhagicum in the ovary of recipient which came into estrus naturally.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Studies on Raw Silk Test and Classification Comparative Studies on Winding Test and Classification between Korean and Japanese Method (생사검사방법 및 격부법에 관한 연구 재조검사의 비교연구 (1))

  • 김한수
    • Journal of Sericultural and Entomological Science
    • /
    • no.11
    • /
    • pp.81-86
    • /
    • 1970
  • This report was prepared to compare and analyze the testing method and classification of winding test in Korea to that in Japan, and the obtained results, which had been carried out, in Korea, from Sep. to Nov. in 1968 and in Japan through June in 1968, was as followings. 1. In Korean raw silk, (21 D.) the average number of breaks on winding test showed 5.91 by Korean Method but showed 8.6 by Japanese method and the latter increased to 2.7. On the other hand in Japanese raw silk, it showed 3.6 by Korean method but 4.7 by Japanese method and the latter increased to 1.1. (See Table 2,3) 2. It was seemed the tendency that the lot distribution of breaks number in Korean silk was mostly concentrated to the breaks No. 3,4 and 5(48%) by Korean method but in case of Japanese method to the breaks number 5,6 and 7(36%), and the tendency that the concentration depended mostly on the increased number of breaks. In Japanese raw silk, it was seemed the tendency that the lot distribution of breaks number was mostly concentrated to the breaks number 1. 2, and 3 (55%) by Korean Method but in case of Japanese Method to the breaks number, 2,3 and 4(50%) and the tendency that the concentration was as similar as the above. (See Table 2,3) 3. It was found the tendency that the distribution of breaks number during the open winding test was mostly concentrate red to the average number of breaks not only in Korea but in Japan. The rate 0: non-breaks, however, showed 43% of Japan, to 7% of Korea. (See Table 4) 4. Applying Table 1,2 to the Classification of Korea and Japan, the class distribution by Korean table showed 68% of class 1(6), 22% of cl ass 2(10) and 9% of class 3(15) in Korean silk, while that by Japanese table showed 13% of class 1(4), 56% of class 2(10) and 29% of class 3(18). And then the testing result to be class 1 or 2 by Korean table was. degraded from class 1 to class 2 of 55% and from class 2 to class 3 of 20% down. In Japanese silk, however, the class distribution by Korean table showed 85% of class 1 (4), 10% of class 2(10) and 5% of class 3(18) but that by Japanese table showed 60% of class 1(4), 33% of class 2(10) and 7% of class 3(18). And then there was little difference in the rate of class distribution. 5. Through the above investigation, it was seemed that Japanese classification table was only prepared for the r∼w silk of Japan, considering that the width of class 1(4) in winding table was greatly tighter than that of Korea. Because it was generally evaluated that Korean silk in quality especially in the winding test was better (next to Japan) than any other countries. 6. We could venture to estimate that, applying to Japanese method, the testing result of break number in Korean silk would show from about 6 by Korean method to 9. And then it would be found degrading hi the testing result of winding test increased gradually.

  • PDF

The Characteristics of REM Sleep-Dependent Obstructive Sleep Apnea and NREM Sleep-Dependent Obstructive Sleep Apnea (렘수면 의존성 수면무호흡증과 비렘수면 의존성 수면무호흡증의 특징)

  • Seo, Min Cheol;Choi, Jae-Won;Joo, Eun-Jeoung;Lee, Kyu Young;Bhang, Soo-Young;Kim, Eui-Joong
    • Sleep Medicine and Psychophysiology
    • /
    • v.24 no.2
    • /
    • pp.106-117
    • /
    • 2017
  • Objectives: Obstructive sleep apnea (OSA) is a sleep-related breathing disorder that is characterized by repetitive collapse or partial collapse of the upper airway during sleep in spite of ongoing effort to breathe. It is believed that OSA is usually worsened in REM sleep, because muscle tone is suppressed during REM sleep. However, many cases showed a higher apnea-hypopnea index (AHI) during NREM sleep than during REM sleep. We aimed here to determine the characteristics of REM sleep-dependent OSA (REM-OSA) and NREM sleep-dependent OSA (NREM-OSA). Methods: Five hundred sixty polysomnographically confirmed adult OSA subjects were studied retrospectively. All patients were classified into 3 groups based on the ratio between REM-AHI and NREM-AHI. REM-OSA was defined as REM-AHI/NREM-AHI > 2, NREM-OSA as NREM-AHI/REM-AHI > 2, and the rest as sleep stage-independent OSA (IND-OSA). In addition to polysomnography, questionnaires related to subjective sleep quality, daytime sleepiness, and emotion were completed. Chi-square test, ANOVA, and ANCOVA were performed. Results: There was no age difference among subgroups. The REM-OSA group was comprised of large proportions of mild OSA and female OSA patients. These patients experienced poor sleep and more negative emotions than other two groups. The AHI and oxygen desaturation index (ODI) were lowest in REM-OSA. Sleep efficiency and N3 percentage of REM-OSA were higher than in NREM-OSA. The percentage of patients who slept in a supine position was higher in REM-OSA than other subgroups. IND-OSA showed higher BMI and larger neck circumference and abdominal circumference than REM-OSA. The patients with IND-OSA experienced more sleepiness than the other groups. AHI and ODI were highest in IND-OSA. NREM-OSA presented the shortest total sleep time and the lowest sleep efficiency. NREM-OSA showed shorter sleep latency and REM latency and higher percentage of N1 than those of REM-OSA and the highest proportion of those who slept in a lateral position than other subgroups. NREM-OSA revealed the highest composite score on the Horne and ${\ddot{O}}stberg$ questionnaire. With increased AHI severity, the numbers of apnea and hypopnea events during REM sleep decreased, and the numbers of apnea and hypopnea events during NREM sleep increased. The results of ANCOVA after controlling age, sex, BMI, NC, AC, and AHI showed the lowest sleep efficiency, the highest AHI in the supine position, and the highest percentage of waking after sleep onset in NREM-OSA. Conclusion: REM-OSA was associated with the mild form of OSA, female sex, and negative emotions. IND-OSA was associated with the severe form of OSA. NREM-OSA was most closely related to position and showed the lowest sleep efficiency. Sleep stage-dependent characteristics could provide better understanding of OSA.

The Impact of Bladder Volume on Acute Urinary Toxicity during Radiation Therapy for Prostate Cancer (전립선암의 방사선치료시 방광 부피가 비뇨기계 부작용에 미치는 영향)

  • Lee, Ji-Hae;Suh, Hyun-Suk;Lee, Kyung-Ja;Lee, Re-Na;Kim, Myung-Soo
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.237-246
    • /
    • 2008
  • Purpose: Three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) were found to reduce the incidence of acute and late rectal toxicity compared with conventional radiation therapy (RT), although acute and late urinary toxicities were not reduced significantly. Acute urinary toxicity, even at a low-grade, not only has an impact on a patient's quality of life, but also can be used as a predictor for chronic urinary toxicity. With bladder filling, part of the bladder moves away from the radiation field, resulting in a small irradiated bladder volume; hence, urinary toxicity can be decreased. The purpose of this study is to evaluate the impact of bladder volume on acute urinary toxicity during RT in patients with prostate cancer. Materials and Methods: Forty two patients diagnosed with prostate cancer were treated by 3DCRT and of these, 21 patients made up a control group treated without any instruction to control the bladder volume. The remaining 21 patients in the experimental group were treated with a full bladder after drinking 450 mL of water an hour before treatment. We measured the bladder volume by CT and ultrasound at simulation to validate the accuracy of ultrasound. During the treatment period, we measured bladder volume weekly by ultrasound, for the experimental group, to evaluate the variation of the bladder volume. Results: A significant correlation between the bladder volume measured by CT and ultrasound was observed. The bladder volume in the experimental group varied with each patient despite drinking the same amount of water. Although weekly variations of the bladder volume were very high, larger initial CT volumes were associated with larger mean weekly bladder volumes. The mean bladder volume was $299{\pm}155\;mL$ in the experimental group, as opposed to $187{\pm}155\;mL$ in the control group. Patients in experimental group experienced less acute urinary toxicities than in control group, but the difference was not statistically significant. A trend of reduced toxicity was observed with the increase of CT bladder volume. In patients with bladder volumes greater than 150 mL at simulation, toxicity rates of all grades were significantly lower than in patients with bladder volume less than 150 mL. Also, patients with a mean bladder volume larger than 100 mL during treatment showed a slightly reduced Grade 1 urinary toxicity rate compared to patients with a mean bladder volume smaller than 100 mL. Conclusion: Despite the large variability in bladder volume during the treatment period, treating patients with a full bladder reduced acute urinary toxicities in patients with prostate cancer. We recommend that patients with prostate cancer undergo treatment with a full bladder.