• Title/Summary/Keyword: quality control of analytical result

Search Result 60, Processing Time 0.027 seconds

A Study on the Statistical Method for the Target Component of a Glucose-lowering Functional Material in Extracts of Evening Primerose Seeds (혈당상승억제 기능성 소재인 달맞이꽃종자 추출물의 지표물질 분석법의 통계적 검증에 대한 연구)

  • Park, Sang-Wook;Bang, Joon Seok;Lee, Wonjae
    • Korean Journal of Clinical Pharmacy
    • /
    • v.26 no.1
    • /
    • pp.70-76
    • /
    • 2016
  • Background: The use of the extracts from evening primrose seeds as a health functional food has been gradually increased. Therefore, the monitoring and screening process has been considerably required for its quality control. Objective: This study aimed to estimate the measurement uncertainty associated with determination of penta-o-galloyl ${\beta}$-D-glucose (PGG) in extracts from evening primrose seeds by high-performance liquid chromatography. Methods: The sources of measurement uncertainty was expressed in accordance with mathematical/statistical theories of GUM & EURACHEM Guide. The expanded uncertainty was calculated by using the relative standard uncertainty between analytical result and sources of uncertainty in measurement (sample weight, final volume, extraction volume, standard solution, matrix and instrument etc). Results: In the results of 95% confidence interval, the uncertainty in measurement was $10,253.34{\pm}1,844.50{\mu}g/kg$ (k = 2.0). Conclusion: In this study, it showed that the value of uncertainty in measurement for determination of PGG in extracts from evening primrose seeds by HPLC has about 18.0% influence on PGG contents of the analytical results. The results would be very useful for the monitoring and screening of evening primrose seeds marketed in Korea for its quality control as dietary supplement.

Interpretation of Analytical Data of Ion Components in Precipitation, Seoul (서울 地域 降水中 이온成分 分析資料의 解析)

  • 강공언;이주희;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.323-332
    • /
    • 1996
  • Precipitation samples were collected by the wet-only sampling method at Seoul from September 1993 to June 1995. Sample were analysed for the anions $(NO_3^-, NO_2^-, SO_4^{2-}, Cl^-, and F^-)$ and cations $(Na^+, K^+, Ca^{2+}, Mg^{2+}, and NH_4^+)$ in addition to pH and electric conductivity. In order to establish the chemical analysis data of high quality, the assurance checks for analytical data of precipitation were performed by considering the ion balance and by comparing the measured conductivity with the calculated conductivity. As we applied the various assurance checking methods by the ion balance used until recently to a data set measured in this study, the f value expressed as $\Sigma C/\Sigma A$ was found to be not appropriate for the data screening. Also, the scattering plot between cations and anions in each sample was found to show the general tendency of ion balance but was proved to not quantitate the standard of data screening at a data set of samples of various concentration levels. The h value defined as (A-C)/C for C $\geq$ A and (A-C)/A for C < A was used to check the ion balance. However, the standard of data screening by h value must very in response to total ion concentration of samples. In this study, the quality assurance of chemical analysis data was checked by considering both the ion balance of evaluating by h value and the conductivity balance. Further the quality control was achieved by these quality assurance methods. As the result, 67 samples among total 77 were obtained as valid. As the central tendency value for a statistical summary in the analytical parametr of samples, the volume-weighted mean value was found to represent more the general chemistry of precipitation rather than the arithmetic mean. The volume-weighted mean pH was 5.0 and 25% of samples was less than this mean. The concentrations of sufate and nitrate in precipitation were 90.4 ueq/L and 32.4 ueq/L which made up 59% and 21% of all anions. The raion of $SO_4^{2-}/(NO_3^- + NO_2^-)$ in precipitation was 2.7, which indicates that the contributions of $H_2SO_4$ and $HNO_3$ to the acidity of precipitation are 70% and 30%, respectively.

  • PDF

Estimation of Storage Capacity for CSOs Storage System in Urban Area (도시유역 CSOs 처리를 위한 저류형시스템 설계용량 산정)

  • Jo, Deok Jun;Lee, Jung Ho;Kim, Myoung Su;Kim, Joong Hoon;Park, Moo Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.490-497
    • /
    • 2007
  • A Combined sewer overflows (CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available (which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a continuous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban drainage system used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range $3{\times}DWF$ (dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a decision of storage volume for CSOs reduction and water quality protection.

Storm-Water CSOs for Reservoir System Designs in Urban Area (도시유역 저류형 시스템 설계를 위한 CSOs 산정)

  • Jo, Deok-Jun;Kim, Myoung-Su;Lee, Jung-Ho;Park, Moo-Jong;Kim, Joong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1199-1203
    • /
    • 2005
  • Combined sewer overflows(CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available(which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a contiunous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban dranage system used analytical Probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics or the subject area using analytical Probabilistic model. Runoff characteristics manifasted the unique characteristics of the subject area with the infiltration capacity of soil and recovery of depression storage and was examined appropriately by sensitivity analysis. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range 3xDWF(dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a dicision of storage volume for CSOs reduction and water quality protection.

  • PDF

Determination of Metallic Elements in Urban Particulate Matter (SRM 1648) by ICP-MS and AAS (ICP-MS와 AAS를 이용한 대기 입자상 표준물질 (SRM 1648) 금속성분의 정량에 관한 연구)

  • Yoo Su-Young;Choi Kum-Chan;Kim Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.423-430
    • /
    • 2005
  • This study was investigated with sample digestion techniques and a reliability of the analytical results for a quantitative analysis of a standard reference material ('urban particulate matter', SRM 1648). The metallic elements were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) with closed vessel microwave acid digestion method and atomic absorption spectroscopy (AAS). Quality control of the overall analytical procedures for metallic element determinations of standard reference material were estimated by analysis of a SRM 1648. Three digestion solutions $(type\;1:\;HNO_3,\;type\;2:\;HNO_3\;and\;H2O_2(4'1)\;mixture,\;type\;3:5.55\%\; HNO_3\;and\;16.75\%\;HCI\;mixture)$ were applied to SRM 1648. As a result, three digestion solutions used in this study are completely unable to digest Cr of SRM 1648. Reliability of Cr and As showed some errors in the digestion with digestion solution type (3) due to the influence of chlorides. Type (3) digestion solutions are sufficient to fulfill the digestion of As as well as Se in SRM 1648. ICP-MS results showed the improvement in accurate and precise determination of some trace elements like Cd, V and Pb in SRM 1648. It is important to use the proper digestion solution for each element to qualify analytical precision.

Evaluation of nutritional adequacy after investigating amino acid and mineral content in pet food distributed in South Korea

  • Ju-Hyeon Choi;Eunhee Chang;Hyung-Ju Seo;Yeong Gil Lee;Jihyun Kim;Guk-Tak Han;Seung Hwa Lee;Tae Woong Na
    • Analytical Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.79-86
    • /
    • 2024
  • Among the nutrients in feed, amino acids and minerals are important for the growth and development of pets. In particular, interest in nutritional components related to the health of pets is increasing as pet-raising households and pet food markets have recently grown. Therefore, in this study, 55 pet food products distributed in South Korea were purchased, and the content of 3 essential and conditionally essential amino acids (taurine, lysine, arginine) and 4 minerals (Ca, P, Na, K) was investigated. Among the three amino acids, arginine was found to have the highest content, and the average content was 1.79 and 1.37 % in cat and dog foods, respectively. On the other hand, the taurine content was the lowest, but it was found to be higher than the minimum requirement of 0.10 % for cats set by the American Association for Feed Control (AAFCO) and the European Federation of Pet Food Industries (FEDIAF). As a result of the four-component analysis of minerals, the content of Ca was found to be the highest, and the average content was confirmed to be 1.64 and 1.25 % in cat and dog food, respectively. On the other hand, Na was the lowest, but it was higher than the AAFCO minimum requirement and FEDIAF minimum requirement for young cat and dog food. Among all 55 samples examined, the content of the three amino acids and the four inorganic components was confirmed to be suitable for the recommended minimum intake and maximum allowable intake presented by AAFCO and FEDIAF.

Uncertainty Evaluation of the Analysis of Methamphetamine and Amphetamine in Human Hair by GC/MS (GC/MS를 이용한 모발 중 메스암페타민 및 암페타민 분석의 측정불확도 평가)

  • Kim, Jin-Young;Kim, Jong-Sang;Kim, Min-Kyoung;Lee, Jae-Il;Suh, Yong-Jun;In, Moon-kyo
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.206-213
    • /
    • 2007
  • Recently estimating the uncertainty of an analytical result has become an essential part of quantitative analysis. This study describes the uncertainty of the measurement for the determination of methamphetamine and its major metabolite amphetamine in human hair, The method consists of washing, drying, weighing, incubation and extraction with methanolic HCI solution, clean-up, trifluoroacetyl derivatization, and qualification/quantification of residues by gas chromatography/mass spectrometry (GC/MS). Traceability of measurement was established through traceable standards and calibrated volumetric equipment and measuring instruments. Measurement uncertainty associated with each analyte in real samples was estimated using quality control (QC) data. The main source of combined standard uncertainty comprised two components, which are uncertainties associated with calibration linearity and variations in QC, while those associated with preparation of analytical standards and sample weighing were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method ranged for individual analytes from 4.99 to5.03%.

MAC Protocol for Reliable Multicast over Multi-Hop Wireless Ad Hoc Networks

  • Kim, Sung-Won;Kim, Byung-Seo;Lee, In-Kyu
    • Journal of Communications and Networks
    • /
    • v.14 no.1
    • /
    • pp.63-74
    • /
    • 2012
  • Multicast data communication is an efficient communication scheme, especially inmulti-hop ad hoc networks where the media access control (MAC) layer is based on one-hop broadcast from one source to multiple receivers. Compared to unicast, multicast over a wireless channel should be able to deal with varying channel conditions of multiple users and user mobility to provide good quality to all users. IEEE 802.11 does not support reliable multicast owing to its inability to exchange request-to-send/clear-to-send and acknowledgement packets with multiple recipients. Thus, several MAC layer protocols have been proposed to provide reliable multicast. However, additional overhead is introduced, as a result, which degrades the system performance. In this paper, we propose an efficient wireless multicast MAC protocol with small control overhead required for reliable multicast in multi-hop wireless ad hoc networks. We present analytical formulations of the system throughput and delay associated with the overhead.

Geostatistical Interpretation of Cs-137 and K-40 Result of the Lithosphere in the Vicinity of Youngkwang Nuclear Power Plant (지구통계학적 방법에 의한 영광원전주변 토층내 Cs-137 및 K-40 측정 결과의 해석)

  • 김경웅;이재석;문승현;박철승;고일원;고은정;조병옥;정철영;전수열
    • Economic and Environmental Geology
    • /
    • v.35 no.6
    • /
    • pp.545-552
    • /
    • 2002
  • In order to investigate the influence of nuclear power plant operation on its nearby environment, soil, stream and marine sediment samples were collected in the vicinity of the Youngkwang Nuclear Power Plant in Korea, and analyzed for artificial and natural radionuclide radioactivity. From the analytical result, Cs-137 was detected in most soil samples. but it may have been derived fiom past nuclear weapon tests because Cs-134 having short half-live was not detected. The radioactivities of Cs-137 in the sediment samples were also detected which are within the normal range in the sediments based upon the published literature between 1997 and 1999. For the quality control of radioactivity analysis of environmental samples, sets of marine sediments in the Gamami area were analyzed using two HPGe Gamma-ray Spectroscopes (30% and 45%) according to the geostatistical sampling strategy, and Cs-137 and K-40 results were interpreted by analysis of variance (ANOVA). In the two-way ANOVA, variances derived from the geochemical variation were significant, but errors from sampling and analytical procedures are negligible. In conclusion. all the radioanalytical procedures of this study including sampling are validated to be acceptable.

Development of Quality Control Method for a Novel Herbal Medicine, HPL-1 using UHPLC (UHPLC를 이용한 새로운 한약제제 HPL-1의 품질관리법 개발)

  • Kim, Se-Gun;Lamichhane, Ramakanta;Lee, Kyung-Hee;Jung, Hyun-Ju
    • The Korea Journal of Herbology
    • /
    • v.30 no.3
    • /
    • pp.19-24
    • /
    • 2015
  • Objectives : HPL-1, a novel herbal medicine which is composed of five herbs such as Kalopanacis Cortex, Chaenomelis Fructus, Raphani Semen, Atractylodis Rhizoma and Pulvis Aconiti Tuberis Purificatum, was developed for treatment of osteoarthritis. This study is aimed to develop analytical method for consistent quality control of HPL-1 and validate chromatographic method. Methods : Chromatographic analysis was performed using ultra-high performance liquid chromatography - diode array detector (UHPLC-DAD) equipped with RP-amide column, column oven, and auto sampler. Marker compounds [protocatechuic acid, chlorogenic acid, liriodendrin, 3,5-dicaffeoylquinic acid, ${\beta}$-D-(3-O-sinapoyl)-fructofuranosyl-$\alpha$-D-(6-O-sinapoyl)glucopyranoside and benzoylmesaconine] were separated by step gradient elution of acetonitrile and 0.1% phosphoric acid/water. The method validation was evaluated by quantitative validation parameters of linearity, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ) according to KFDA guideline.Results : An optimized method for six marker compounds in HPL-1 was established by UHPLC-DAD. The correlation coefficient (R2) with each calibration curve was greater than 0.99. The LOD and LOQ were within the range of 0.008-0.090 and $0.023-0.274{\mu}g/mL$, respectively. The relative standard deviation (RSD) of intra- and inter-day variability were less than 4.0%. The result of recovery test was range from 93.3-106.3% with RSD < 4.0%.Conclusions : These results suggest that the quantitative UHPLC method is precise, accurate, effective for quality evaluation of HPL-1. The method may also contribute to improve quality of crude drug preparations used for treatment of various diseases.