• Title/Summary/Keyword: quality coefficient

Search Result 2,442, Processing Time 0.032 seconds

Determination of Appropriate Exposure Angles for the Reverse Water's View using a Head Phantom (두부 팬텀을 이용한 Reverse Water's View에 관한 적절한 촬영 각도 분석)

  • Lee, Min-Su;Lee, Keun-Ohk;Choi, Jae-Ho;Jung, Jae-Hong
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.187-195
    • /
    • 2017
  • Early diagnosis for upper facial trauma is difficult by using the standard Water's view (S-Water's) in general radiograph due to overlapping of anatomical structures, the uncertainty of patient positioning, and specific patients with obese, pediatric, old, or high-risk. The purpose of this study was to analyze appropriate exposure angles through a comparison of two different protocols (S-Water's vs. reverse Water's view (R-Water's)) by using a head phantom. A head phantom and general radiograph with 75 kVp, 400 mA, 45 ms 18 mAs, and SID 100 cm. Images of R-Water's were obtained by different angles in the range of $0^{\circ}$ to $50^{\circ}$, which adjusted an angle at 1 degree interval in supine position. Survey elements were developed and three observers were evaluated with four elements including the maxillary sinus, zygomatic arch, petrous ridge, and image distortion. Statistical significant analysis were used the Krippendorff's alpha and Fleiss' kappa. The intra-class correlation (ICC) coefficient for three observers were high with maxillary, 0.957 (0.903, 0.995); zygomatic arch, 0.939 (0.866, 0.987); petrous ridge, 0.972 (0.897, 1.000); and image distortion, 0.949 (0.830, 1.000). The high-quality image (HI) and perfect agreement (PA) for acquired exposure angles were high in range of the maxillary sinus ($36^{\circ}-44^{\circ}C$), zygomatic arch ($33^{\circ}-40^{\circ}$), petrous ridge ($32^{\circ}-50^{\circ}$), and image distortion ($44^{\circ}-50^{\circ}$). Consequently, an appropriate exposure angles for the R-Water's view in the supine position for patients with facial trauma are in the from $36^{\circ}$ to $40^{\circ}$ in this phantom study. The results of this study will be helpful for the rapid diagnosis of facial fractures by simple radiography.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

A Comparative Study regarding Health Condition and Work Stress of Nurses Working in Cancer Ward and General Ward (암병동간호사와 일반병동간호사의 건강상태와 직무스트레스 비교 연구)

  • Kim, Hyun-Sook
    • Asian Oncology Nursing
    • /
    • v.1 no.2
    • /
    • pp.191-203
    • /
    • 2001
  • The health of a nurse is very important because her mental and physical health can influence toward nursing patients directly, Especially, Cancer patients are growing annually. Also, terminal cancer patients' nursing and dead place are increasingly using hospital and the period of nursing for cancer patients are increasing. Nursing for cancer patients are different with acute disease. Therefore, I analysed comparing nurses' health working in cancer and general ward so that nurses working at cancer ward could be developed as a professional nurse, and I wanted to establish the foundation of nursing administration and reasonable manpower management to supply good quality of nursing to patients. In my research, I selected 117 nurses working in cancer ward and 134 nurses working in general word to analyse the stress rate and nurse's health comparing nurses working in general ward and cancer ward. The survey was conducted of nurses working in cancer ward nurses in 2 university hospitals, nurses working in a cancer hospital, and general ward nurses working in 3 public hospital. Also, the data was collected from Sep. 13, 2001 to Sep. 28, 2001. As health measuring tool, I used Cornell Medical Index(CMI) which are developed to fit Koreans by Ko Ungrin and Park Hang-bas (1980) using Cornell Medical Services which were designed by Weiser, Brosman, Mittelman, Wechler, Wolff in Cornell University(1945). As working stress measuring tool, I used Questionaries which were designed by Kim Mae-ja and Ku Mi-ok(1984) and then developed by Bae In-sook(1996). For managing the data, I used frequency, percentage, ${\chi}^2$ verification, t-test, and F-test (ANOVA). And in the case of significant data(p<.05). I did Duncan's test for post verification. The mutual relation between health condition and working stress rate have been conducted using Pearson's Correlation Coefficient. Followings are the results of my research. 1. Two groups showed significant differency at age after testing homogeneous character between two groups (${\chi}^2$ =9.919, p=.007). 2. Comparing two group's health condition, cancer ward(average 19.35${\pm}$18.34) were higher than general ward(14.42${\pm}$10.59) and showed statistical significant differency(p=.009). And, comparing two group's mental condition, cancer ward(9.00${\pm}$9.79) were higher than general ward(7.13${\pm}$6.35) and statistically no differency. 3. After comparing two group's working stress rate, the rate of cancer ward nurse's working stress(3.36${\pm}$.50) is higher than general ward nurse (3.32${\pm}$.48). There are no significant differency. However, in the detailed verification test, there were significant differency at inappropriate compensation (t=3.254, p=.001) and medication issue (t=2.170, p=.031). 4. After comparing health condition at general points, physical health condition showed significant differency at age(p=.020), the number of children (p=.015), religion (p=.015), position(p=.005), career(p=.008), working satisfaction(p=.003), activity after office hour(p=.045); and mental health condition showed significant differency at position(p=.010), career (p=.017), working satisfaction (p=.003). 5. After comparing the working stress rate according to general points, there were significant differency at working satisfaction (F=5.285, p=.006), predicted nursing(F=3.822, p=.023). 6. At the relation of health condition and working stress rate between two groups. physical and mental condition showed significant relation with working stress rate. i.e, if a nurse's health condition is not good, she are feeling much more stress than others. After considering all the factors in my research, I found that the health condition and stress rate of cancer ward nurses is much higher than general ward nurses. Considering that cancer ward nurses is necessary to care for increasing cancer patients with mental and physical nursing, the less stress for cancer ward nurses is very important to develop nursing quality and working efficiency by keeping good health condition, specializing cancer ward nurses. Therefore, we need following studies to find the factors which are effecting to cancer ward nurses' health and specialization. Also, we need to improve managing working condition to decrease working stress by improving working condition.

  • PDF

A Study on the Technology Collaboration between the Main Supplier and Buyer under the Dynamic Environment: The Focus on the Performance of New Product Development (역동적 환경 하에 구매사/주공급사 간의 기술협력은 신제품 개발 프로젝트 성과를 향상시키는가?)

  • Lee, Younsuk;Ham, Minjoo;Moon, Seongwuk
    • Journal of Technology Innovation
    • /
    • v.23 no.3
    • /
    • pp.397-432
    • /
    • 2015
  • This paper investigates the effects of technology collaboration between the main supplier and buyer on buyer's new product development under dynamic environment. Based on 428 Korean manufacturing firms, we conducted regression analysis. The technology collaboration between the main supplier and buyer is adopted as a independent variable and quality, cost and lead time performance of new product development projects are used as dependents variables. Environment dynamic is also used as a moderate variables. We found that the in general, technology collaboration is positively associated with the performance of buyers' new product development, but in the high degree of dynamic environment, technology collaboration is negatively associated with the performance of buyers' new product development unlike our expectation. Thus, we divide our sample into two groups; shipbuilding industry with the low degree of environment dynamic and electronic and IT device industry with the high degree of environment dynamic and conducted a post hoc analysis. As a result, in ship building industry, the technology collaboration is significant to improve NPD projects performance, while in electronic and IT device industry, the technology collaboration with a main supplier is not significant as well as coefficient is negative. In that, under the highly dynamic condition with the fast change of technology and products obsolescence the NPD collaboration with the main supplier does not works unlike a stable environment. This implies that the NPD attributes of buyer are different by their environmental factor and the fit between given environmental feature and the collaboration synergy is critical factor for improving the effect of NPD collaboration between supplier and buyer.

Analysis on Longitudinal Dose according to Change of Field Width (선속 폭(Field Width) 변화에 따른 종축선량 분석)

  • Jung, Won-Seok;Back, Jong-Geal;Shin, Ryung-Mi;Oh, Byung-Cheon;Jo, Jun-Young;Kim, Gi-Chul;Choi, Tae-Gu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • Purpose: To analyze the accuracy of tumor volume dose following field width change, to check the difference of dose change by using self-made moving car, and to evaluate practical delivery tumor dose when tomotherapy in the treatment of organ influenced by breathing. Materials and Methods: By using self-made moving car, the difference of longitudinal movement (0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm) was applied and compared calculated dose with measured dose according to change of field width (1.05 cm, 2.50 cm, 5.02 cm) and apprehended margin of error. Then done comparative analysis in degree of photosensitivity of DQA film measured by using Gafchromic EBT film. Dose profile and Gamma histogram were used to measure degree of photosensitivity of DQA film. Results: When field width were 1.05 cm, 2.50 cm, 5.02 cm, margin of error of dose delivery coefficient was -2.00%, -0.39%, -2.55%. In dose profile of Gafchromic EBT film's analysis, the movement of moving car had greater motion toward longitudinal direction and as field width was narrower, big error increased considerably at high dose part compared to calculated dose. The more field width was narrowed, gamma index had a large considerable influence of moving at gamma histogram. Conclusion: We could check the difference of longitudinal dose of moving organ. In order to small field width and minimize organ moving due to breathing, it is thought to be needed to develop breathing control unit and fixation tool.

  • PDF

Microwave Dielectric Properties of $PbWO_{4}-TiO_{2}-CuO-B_{2}O_{3}$ Ceramics ($PbWO_{4}-TiO_{2}-CuO-B_{2}O_{3}$ 세라믹의 고주파 유전특성)

  • 이경호;최병훈
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.143-148
    • /
    • 2001
  • PbWO$_4$ can be densified at 85$0^{\circ}C$ and it shows fairy good microwave dielectric properties; dielectric constant($\varepsilon$$_{r}$) of 21.5, quality factor(Q $\times$f$_{0}$) of 37,224 GHz, and temperature coefficient of resonant frequency($\tau$/suf f/) of -31ppm/$^{\circ}C$. Due to its low sintering temperature, PbWO$_4$ can be used as a multilayered chip component at microwave frequency with high electrical performance by using high conductive electrode metals such as Ag and Cu. However, in order to use this material for microwave communication devices, the $\tau$$_{f}$ of PbWO$_4$ must be stabilized to near zero with high Q$\times$f$_{0}$. In present study, PbWO$_4$ was modified by adding TiO$_2$, B$_2$O$_3$, and CuO in order to improve the microwave dielectric properties without increasing the sintering temperature. The addition of TiO$_2$ increased the $\tau$$_{f}$ and $\varepsilon$$_{r}$, due to its high rr(200ppm/$^{\circ}C$) and $\varepsilon$$_{r}$(100). However, the addition of TiO$_2$ reduced the Q$\times$f$_{0}$ value. When the mot ratio of PbWO$_4$ and TiO$_2$ was 0.913:7.087, near zero $\tau$$_{f}$(0.2ppm/$^{\circ}C$) was obtaibed with $\varepsilon$$_{r}$=22.3, and Q$\times$f/$_{0}$=21,443GHz. With this composition, various amount of B$_2$O$_3$ and CuO were added in order to improve the quality factor. The addition, of B$_2$O$_3$ decreased the $\varepsilon$$_{r}$. However, increased Q$\times$f$_{0}$ and $\tau$$_{f}$. When 2.5 wt% of B$_2$O$_3$ was added to the 0.913PbWO$_4$-0.087TiO$_2$ ceramic, $\tau$$_{f}$ =8.2, $\varepsilon$$_{r}$=20.3, Q$\times$f$_{0}$=54784 GHz. When CuO added to the 0.913PbWO$_4$-0.087TiO$_2$ ceramic, $\tau$$_{f}$ was continuously decreased. And $\varepsilon$$_{r}$ . and Q$\times$f$_{0}$ were increased up to 1.0 wt% then decreased. At 0.1 wt% of CuO addition, the 0.913PbWO$_4$-7.087Ti0$_2$ Ceramic Showed $\varepsilon$$_{r}$=23.5, $\tau$$_{f}$=4.4ppm/$^{\circ}C$, and Q$\times$f$_{0}$=32,932 GHz.> 0/=32,932 GHz.X>=32,932 GHz.> 0/=32,932 GHz.

  • PDF

Hydrochemistry of Groundwater at Natural Mineral Water Plants in the Okcheon Metamorphic Belt (옥천계변성암 지역의 먹는샘물 지하수의 수리지구화학적 특성)

  • 추창오;성익환;조병욱;이병대;김통권
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.3
    • /
    • pp.93-107
    • /
    • 1998
  • Because of its stable quantity and quality, groundwater has long been a reliable source of drinking water for domestic users. Rapid economic growth and rising standards of living have in recent years put severe demands on drinking water supplies in Korea. Groundwaters that are currently being used for natural mineral water were hydrochemically evaluated and investigated in order to maintain their quality to satisfy strict health standards. There exist 15 natural mineral water plants in the Okcheon metamorphic belt. Characteristics of groundwaters are different from those of other areas in that electrical conductivity, hardness, contents of Ca, Mg and $HCO_3$are relatively high. The content of major cations is in the order of Ca>Mg, Na>K, whereas that of major anions shows the order of $HCO_3$>$SO_4$>Cl>F. The fact that the Ca-Mg-HCO$_3$type is mostly predominant among water types reflects that dissolution of carbonates that are abundantly present in the metamorphic rocks plays an important part in groundwater chemistry. Representative correlation coefficients between chemical species show Mg-$HCO_3$(0.92), Ca-$HCO_3$(0.88), Ca-Mg(0.80), Ca-Cl(0.78), Mg-$SO_4$(0.78), Ca-$SO_4$(0.71), possibly due to the effect by dissolution of carbonates, gypsum or anhydrite. Determinative coefficients between some chemical species represent a good relationship, especially for EC-(K+Na+Ca), Ca-$HCO_3$, Ca-Mg, indiacting that they are similar in chemical behaviors. According to saturation index, most chemical species are undersaturated with respect to major minerals, except for some silica phases. Groundwater is slightly undersaturated with respect to calcite and dolomite, whereas it is still greatly undersaturated with respect to gypsum, anhydrite and fluorite, Based on the Phase equilibrium in the systems $NA_2$O-$Al_2$$O_3$-$SiO_2$-$H_2$O and $K_2$O-$Al_2$$O_3$-$SiO_2$-$H_2$O, it is clear that groundwater is in equilibrium with kaolinite, evolved from the stability area of gibbsite during water-rock interaction. It is expected that chemical evolution of groundwater continue to proceed with increasing pH by reaction of feldspars, with calcite much less reactive.

  • PDF

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Multivariate Analysis of Variation of Growth and Quality Characteristics in Colored Rice Germplasm (유색미 도입 유전자원의 생육 및 품질특성 변이 다변량 분석)

  • Park, Jong-Hyun;Lee, Ji-Yoon;Chun, Jae-Buhm;You, Oh-Jong;Son, Eun-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.63 no.3
    • /
    • pp.175-185
    • /
    • 2018
  • The aim of this study was to evaluate the variation of growth and quality characteristics in colored rice from 178 accessions and to develop useful, basic rice breeding data by classifying these germplasm characteristics via principal component (PC) analysis. The coefficient of variation of the 178colored rice accessions were the highest for panicle length (PL) and protein contents, followed by length-width ratio (LWR), 1000-grain weight (TGW), culm length (CL), and amylose contents, whereas the lowest was for the number of panicles per hill (NP), which is a yield component. The results from the PC analysis exhibited eigenvalues and contributions respective to each PC as follows: PC1, 2.06 and 29.49%; PC2, 1.31 and 18.75%; PC3, 1.21 and 17.36%; PC4, 1.01 and 14.38%. The eigenvalues of four PCs were over 1.0, and their cumulative contributions were 79.98%, which completes the necessary condition for evaluation of the 178 colored rice accessions. Cluster analysis showed cluster I as the largest, which included 79 accessions, while clusters II, III, IV, V, VI, and VII comprised 46, 19, 13, 4, 8, and 9 accessions, respectively. Moreover, dark brown accessions were dispersed in clusters I and II, and many resources of purple seed coat color were found in clusters V, VI, and VII. Particularly, cluster V had resources of only black and purple seed coat colors. Resources of cluster VII were found to have a relatively small average CL, PL, and LWR; notably, cluster V had the smallest average TGW, and cluster IV the lowest NP but the highest TGW. Finally, considering the yield potential, growth characteristics, heading stage, and color during breeding of colored rice, we obtained the following conclusions: cluster VII is suitable for breeding of colored rice; cross breeding among clusters I, II, and VII has a high yield potential; and it is possible to produce a superior color by cross breeding plants from cluster V and VI.

Shoot Growth and Fruit Characteristics According to Bearing Branch Direction and Thickness in 'Kawanakajima Hakuto' Peach Trees (복숭아 '천중도백도'의 결과지 방향 및 굵기에 따른 신초 생장과 과실 특성)

  • Yun, Seok Kyu;Yoon, Ik Koo;Nam, Eun Young;Jun, Ji Hae;Kwon, Jung Hyun;Bae, Haejin;Kim, Ho Cheol;Kim, Tae-Choon
    • Horticultural Science & Technology
    • /
    • v.32 no.4
    • /
    • pp.421-426
    • /
    • 2014
  • To investigate the optimal size of fruit bearing branches (FBBs) of 'Kawanakajima Hakuto' peach (Prunus persica Batsch) for production of high quality fruits, we evaluated shoot growth and fruit characteristics relative to FBB direction and thickness. FBB diameter, shoot length, fruit weight, and soluble solids content (SSC) averaged 6.9 mm, 32.6 cm, 333.6 g, and $11.2^{\circ}Brix$, respectively. Coefficients of variation of FBB diameter and shoot length were high as 35.8% and 75.3%. The highest frequency values revealed that 76.4% of FBBs had a diameter below 9.0 mm, 70.0% of shoot lengths were less than 40 cm, 24.8% of fruits were 310-340 g, and 66.9% of SSCs were $10.5-12.5^{\circ}Brix$. Shoot length and SSC were significantly affected by FBB diameter without direction, and fruit weight was significantly affected by interaction of FBB diameter and direction. There was a negative correlation ($r^2=0.094^*$) of FBB diameter and fruit weight with upward FBB directions, whereas FBB diameter and fruit weight were positively correlated ($r^2=0.246^{**}$) with downward FBB direction. With thick FBB diameter, shoot length, and SSC were significantly increased, but fruit weight was decreased. Therefore, downward FBBs below 9.0 mm in thickness are suitable for producing high-quality fruits of 'Kawanakajima Hakuto' peach.