• Title/Summary/Keyword: pure tone audiometry

Search Result 60, Processing Time 0.025 seconds

IoT based Pure Tone Audiometer with Software Platform Compatibility (IoT 기반의 소프트웨어 플랫폼 호환성을 갖는 순음청력 검사기)

  • Kang, Sung Ho;Lee, Jyung Hyun;Kim, Myoung Nam;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.2
    • /
    • pp.261-270
    • /
    • 2018
  • Hearing-impaired people are increasing rapidly due to the global aging trend. Early detection of hearing loss requires an easy-to-use audiometry device for the public. Existing audiometry systems were developed as PC-based, PDA-based, or smartphone apps. These devices were often dependent on specific software platforms and hardware platforms. In this paper, we tried to improve software platform compatibility by using cross platform, and tried to implement IoT-based pure tone audiometry device which does not require sound pressure level correction due to hardware differences. Pure tone audiometry is available in a variety of ways depending on the type of hearing loss and age. Using the IoT-based audiometry device implemented in this paper, it will be possible for an app developer who lacks hardware knowledge to easily develop an app with various scenarios for hearing screening. The results of this study will contribute to overcoming the software and hardware dependency in the development of IoT-based healthcare device.

Remote Patient Monitoring System for Diagnostic Pure-tone Audiometry (순음 청력검사를 위한 원격진단 모니터링 시스템)

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.289-293
    • /
    • 2019
  • This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ${\pm}0.4dB$, an accuracy of ${\pm}0.025%$, and a total harmonic distortion (THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

Effectiveness of Computer-Animated Pure Tone Audiometry for Screening (애니메이션을 이용한 순음청력선별검사 도구의 효용성에 대한 연구)

  • Kim, Young-Min;Lee, Moo-Kyung
    • Phonetics and Speech Sciences
    • /
    • v.2 no.3
    • /
    • pp.151-156
    • /
    • 2010
  • The purpose of this study was to develop a computer-animated pure tone audiometry for screening (CAPTAS) for toddler and to determine its validity and reliability. The CAPTAS utilizes an animated cartoon story producing visual and auditory stimuli. The intensities were 40 dB, 60 dB, 80 dB. The frequencies were 500 Hz, 1000 Hz, 2000 Hz, and 4000 Hz. The subjects were 20 (9 males and 11 females) severely hearing impaired children. As a result, The correlation coefficient between mean hearing threshold of children who were able to perform PTA and average hearing threshold of CAPTAS was performed and it revealed CAPTAS's high validity. And to verify the reliability of the re-test, all children had the CAPTAS and repeated it periodically. The result confirmed the reliability.

  • PDF

The Effect of Workplace Noise on the Hearing Threshold of Dental Technicians

  • Lee, Ju Hee;Lee, Hye Ran;Lee, Og Kyoung
    • Biomedical Science Letters
    • /
    • v.20 no.4
    • /
    • pp.201-208
    • /
    • 2014
  • This study was conducted to investigate hypoacusis due to workplace noise among dental technicians. Pure tone audiometry, impedance audiometry and heart rate variability were measured for 60 dental technicians and office workers in D city from July to November 2013, and a survey on the effects of noise was conducted. SPSS 19.0 was used for statistical analysis. In the result for threshold of pure tone audiometry, the average hearing threshold of left ears in the air conduction (AC) test showed a statistically significant decrease (P=0.019) among dental technicians, who are frequently exposed to workplace noise. The hearing threshold in the AC test for each frequency was significantly different between the two groups at 125 Hz (P=0.012) in right ears and at 1 kHz (P=0.022), 2 kHz (P=0.040), and 8 kHz (P=0.018) in left ears. Dental technicians who had worked for 16 years or longer had a significantly higher incidence of hypoacusis in the right ear (P=0.030) and in the left ear (P=0.010). In impedance audiometry showed a tympanometry result of type A in both the dental technician group and the office worker group.

The Clinical Study of Three Patients Hospitalized Due To Sudden Sensorineural Hearing Loss (돌발성 난청 환자 3례에 대한 임상적 고찰)

  • Kwon, Kang;Choi, Kwan-Ho;Park, Jae-Young;Owi, Jong-Sung;Park, Hee-Soo;Park, Young-Hwan
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.15 no.2
    • /
    • pp.156-168
    • /
    • 2002
  • Backgrounds : sudden sensorineural hearing loss is defined as a disease that has abrupt onset of sensorineural hearing loss without definite cause. In some cases, this disease cause tinnitus, vertigo, headache addition to hearing loss. In traditional oriental medicine, sudden sensorineural hearing loss is could be diagnosed as deficiency of Yang-Gi(陽氣). Objects & Methods : This study is clinical observation about three sudden sensorineural hearing loss cases. For diagnosing in these cases, pure tone audiometry was used. For treatment, acupuncture, herbal-medicine and moxibustion therapy were used. Results & Conclusions : as follows. 1. Generally, in this disease, the shorter the whole period from the time that occurs to the time that starts to treat is, the more the results are better. The research shows that short-term case is more efficient than the other long-term two cases in the aspects of symptoms and pure tone audiometry . 2. In making a diagnosis of sudden sensorineural hearing loss and measuring the effect, subjective symptoms generally correspond to the improvement of pure tone audiometry, but not completely. Therefore, in treating patients, the doctor must consider these both aspects and keep the balance.

  • PDF

Development of Ambulatory Audiometric System by Sound Pressure Level Calibration (음압 보정을 통한 이동형 청력 검사 시스템 구현)

  • Shin, Seung-Won;Kim, Kyeong-Seop;Yoon, Tae-Ho;Lee, Sang-Min;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1157-1164
    • /
    • 2007
  • In this paper, we implement a PDA(Personal Digital Assistant)-based audiometric system in order to estimate hearing threshold by adopting both pure-tone sound and speech audiometric test system. To estimate a subject's hearing threshold in an ambulatory audiometric test environment, an efficient sound calibration scheme between a PDA and a headphone device is proposed by appling polynomial fitting algorithms in 8-banded frequency ranges.

Three Cases of Sudden Sensorineural Hearing Loss with Marked or Complete Recovery (Marked recovery 이상 호전된 돌발성 난청 환자 치험 3례)

  • Yu, Hyun-Jung;Hong, Seung-Ug
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.19 no.2
    • /
    • pp.263-271
    • /
    • 2006
  • Objective : This study describes the cases of sensorineural hearing loss (SSNHL) patients with marked or complete recovery. Methods : Three patients received oriental medical treatments continuously for more than 1 month and measured the hearing recovery. For diagnosis on these cases, pure tone audiometry (GSI 38, Welch allyn company) was used. For treatment, acupuncture, herbal-medicine and moxibustion treatment were applied. Results : All patients of this report had the recovery of hearing. In 2 cases, the pure-tone 5 frequency (0.25, 0.5, 1, 2, 4 KHz) average improved by more than 35 dB (Marked recovery). In 1 case, it was within the normal limits after oriental medical therapy (Complete recovery). In addition, tinnitus and vertigo decreased in all patients. Conclusions : We may expect that the oriental medical therapy improvers the hearing recovery in the patients of SSNHL.

  • PDF

A Comparison of Pure-Tone Thresholds to the Pre and Post Fogging after Refractive Correction in Normal Eyes (굴절교정된 정상안에서 운무 전후에 따른 순음청력역치의 비교)

  • Cho, Soo-Jin;Joo, Seok-Hee;Lee, Koon-Ja;Choi, In-Sil;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.89-93
    • /
    • 2009
  • Purpose: To purpose of this study was the pure-tone audimetry changes to compare pre and post fogging after visual correction in normally hearing adults. Methods: The estimated that no ocular and audiolar disesases, we selected (male: 30, female: 20) in corrected visual acuity over the 1.0 eye. Pre and post fogging were measured using the pure-tone audimetry. Results: To compared fre and post fogging, fre fogging was higher than fre fogging. The take value were just about every kind of Hz but 200 Hz, respectively which were statistically significant (p<.05). Low Hz area in 250 and 500 Hz were 6.8${\pm}$8.4dBHL, 4.3${\pm}$6.6dBHL, there is not all the difference between any other area, 2000 Hz in the middle Hz area was 0.8${\pm}$4.5dBHL. Conclusions: The study presents different results of measurements in within normal limits. we thought that pure-tone thresholds to the pre and post fogging after refractive correction in normal adults and would be used basic data.

  • PDF

Influence of stress and pure tone audiometry on noise-exposed dental laboratory technicians by dental instrument (치과기공 소음 노출이 치기공과 학생의 스트레스와 순음청력에 미치는 영향)

  • Yon, Jung-Min;Lee, Ju-Hee;Kim, Dae-Hyun;Lee, Og-Kyoung
    • Journal of Digital Convergence
    • /
    • v.14 no.4
    • /
    • pp.363-370
    • /
    • 2016
  • Noise is unwanted sound that is the reason of the stress and hearing loss. The current study attempted to estimate whether the noise of dental laboratory affected stress and pure tone audiometry (PTA) of dental laboratory technicians (DLTs) using heart rate variability, air and bone conduction audiometry. The age, heights, and weights of DLTs were resembled control. Standard deviation of normal to normal interval such as stress resistance and normalized HF of DLTs were significantly decreased, but heart rates, normalized LF, and LF/HF ratio of DLTs were significantly increased compared with control. In air conduction audiometry of DLTs, significant increments of thresholds encountered in 125, 250, 500, 1000, 2000, 3000, 4000, and 6000 Hz in the right ears and 125, 250, 500, 1000, and 2000 Hz in the left ears. Thresholds of bone conduction audiometry in both ears were significantly increased in 250, 500, 1000, 2000, and 4000 Hz. The findings in this study provide that stress and hearing loss observed in noise-exposed DLTs at dental laboratory. Therefore, proper safety precautions should be carried out at dental laboratory.

A Case Study of a Taeeumin Patient with Idiopathic Sudden Sensorineural Hearing Loss that accompanied with Tinnitus who was treated with Cheongsimyeonja-tang (청심연자탕으로 관리한 이명을 동반한 돌발성 난청 치험례)

  • Lee, Mi-Suk;Hwang, Mim-Woo;Kim, Yun-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.23 no.3
    • /
    • pp.419-428
    • /
    • 2011
  • 1. Objective: The aim of this study was to report significant improvement of tinnitus and insomnia after treatment with Cheongsimyeonja-tang in a Taeeumin patient with Idiopathic Sudden Sensorineural Hearing Loss(SSHL) that accompanied with Tinnitus. 2. Method: We measured the hearing recovery. For diagnosis on this case, pure tone audiometry was used. The degree of improvement was evaluated by Siegel's Criteria. Visual Analogue Scale(VAS) and Tinnitus Handicap Inventory(THI) were also used to assess tinnitus objectively. 3. Result: There was no improvement in pure tone audiometry by Siegel's Criteria. However, VAS score was decreased from 10 to 1 and THI score was also decreased from 74 to 48. 4. Conclusion: A patient with SSHL, who has little possibility of recovery of hearing loss, was treated with Cheongsimyeonja-tang in a short period and significant improvement in tinnitus and insomnia was observed. We consider that consistent treatment of Cheongsimyeonja-tang can contribute to improve the hearing loss.